DocID15354 Rev 12 9/23
2N3700HR Radiation hardness assurance
23
3 Radiation hardness assurance
The products guaranteed in radiation within the JANS system fully comply with the MIL-
PRF-19500/255 specification.
The products guaranteed in radiation within the ESCC system fully comply with the ESCC
5201/004 and ESCC 22900 specifications.
JANS radiation assurance
ST JANS parts guaranteed at 100 krad (Si), tested, in full compliancy with the MIL-PRF-
19500 specification, specifically the Group D, subgroup 2 inspection, between 50 and 300
rad/s. On top of the standard JANSR high dose rate by wafer lot guarantee, ST 2N3700HR
series include an additional wafer by wafer 100 krad Low dose rate guarantee at 0.1 rad/s,
identical to the ESCC 100 krad guarantee. It is supported with the same Radiation
Verification Test report provided with each shipment. A brief summary of the standard High
Dose Rate by wafer lot JANSR guarantee is provided below:
•All test are performed in accordance to MIL-PRF-19500 and test method 1019 of MIL-
STD-750 for total Ionizing dose.
•The table below provides for each monitored parameters of the test conditions and the
acceptance criteria.
Table 6. MIL-PRF-19500 (test method 1019) post radiation electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
CBO
Collector cut-off
current (I
E
= 0) V
CB
= 140 V - 20 µA
I
CES
Collector-emitter cut-
off current V
CE
= 90 V - 20 nA
I
EBO
Emitter cut-off current
(I
C
= 0) V
EB
= 5 V
V
EB
= 7 V -20
20 nA
µA
V
(BR)CEO
Collector-emitter
breakdown voltage
(I
B
= 0) I
C
= 30 mA - 80 V
V
CE(sat)
Collector-emitter
saturati on vol t age I
C
= 150 mA I
B
= 15 mA
I
C
= 500 mA I
B
= 50 mA -0.23
0.58 V
V
V
BE(sat)
Base-emitter
saturati on vol t age I
C
= 150 mA I
B
= 15 mA - 1.1 V
[h
FE
]
Post irradiat ion gain
calculation
I
C
= 150 mA V
CE
= 10 V [50]
(1)
1. See method 1019 of MIL-STD-750 for how to determine [h
FE
] by first calculating the delta (1/h
FE
) from the
pre- and post-radiation h
FE
. Notice the [h
FE
] is not the same as h
FE
and cannot be measured directly. The
[h
FE
] value can never exceed the pre-radiation minimum h
FE
that it is based upon.
-300
I
C
= 0.1 mA V
CE
= 10 V [25 ]
(1)
-200
I
C
= 10 mA V
CE
= 10 V [45 ]
(1)
-
I
C
= 500 mA V
CE
= 10 V [25]
(1)
-200
I
C
= 1.0 A V
CE
= 10 V [7.5]
(1)
-