KBU4A thru KBU4M Vishay General Semiconductor Single-Phase Bridge Rectifier FEATURES * UL recognition file number E54214 * Ideal for printed circuit boards e4 * High surge current capability * High case dielectric strength of 1500 VRMS ~ * Solder dip 260 C, 40 s ~ ~ ~ * Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC Case Style KBU TYPICAL APPLICATIONS General purpose use in ac-to-dc bridge full wave rectification for monitor, TV, printer, SMPS, adapter, audio equipment, and home appliances applications. PRIMARY CHARACTERISTICS MECHANICAL DATA Case: KBU IF(AV) 4A VRRM 50 V to 1000 V IFSM 200 A Epoxy meets UL 94V-0 flammability rating IR 5 A VF 1.0 V TJ max. 150 C Terminals: Silver plated leads, solderable per J-STD-002 and JESD22-B102 E4 suffix for consumer grade Polarity: As marked on body Mounting Torque: 10 cm-kg (8.8 inches-lbs) max. Recommended Torque: 5.7 cm-kg (5 inches-lbs) MAXIMUM RATINGS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL KBU4A KBU4B KBU4D KBU4G KBU4J KBU4K KBU4M UNIT Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS voltage VRMS 35 70 140 280 420 560 700 V VDC 50 100 200 400 600 800 1000 V Maximum DC blocking voltage Maximum average forward rectified output current at TC = 100 C (1) TA = 30 C (2) Peak forward surge current single sine-wave superimposed on rated load Operating junction and storage temperature range IF(AV) 4.0 4.0 A IFSM 200 A TJ, TSTG - 50 to + 150 C Notes: (1) Units mounted on a 2.0 x 1.6 x 0.3" thick (5 x 4 x 0.8 cm.) aluminum plate (2) Units mounted on P.C.B. with 0.5 x 0.5" (12 x 12 mm) copper pads and 0.375" (9.5 mm) lead length Document Number: 88656 Revision: 15-Apr-08 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com www.vishay.com 1 KBU4A thru KBU4M Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL KBU4A KBU4B KBU4D KBU4G KBU4J KBU4K KBU4M UNIT Maximum instantaneous forward drop per diode 4.0 A VF 1.0 V Maximum DC reverse current at rated DC blocking voltage per diode TA = 25 C TA = 125 C IR 5.0 1.0 A mA THERMAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL KBU4A KBU4B KBU4D KBU4G Typical thermal resistance KBU4J KBU4K KBU4M 19 (2) 4.0 (1) RJA RJL UNIT C/W Notes: (1) Units mounted on a 2.0 x 1.6 x 0.3" thick (5 x 4 x 0.8 cm.) aluminum plate (2) Units mounted on P.C.B. with 0.5 x 0.5" (12 x 12 mm) copper pads and 0.375" (9.5 mm) lead length (3) Recommended mounting position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE 8.0 51 250 Anti-static PVC tray KBU4J-E4/51 RATINGS AND CHARACTERISTICS CURVES (TA = 25 C unless otherwise noted) 200 60 Hz Resistive or Inductive Load 3 Heatsink Mounting, TC, 2.0 x 1.6 x 3.0" (5.0 x 4.0 x 0.8 cm) Al. Plate 2 1 TA, P.C.B. Mounting 0.47" x 0.47" (12 x 12 mm) Copper Pads 0 Peak Forward Surge Current (A) Average Forward Current (A) 4 TJ = 150 C Single Sine-Wave 175 150 125 100 75 50 25 0 50 100 150 1 100 10 Temperature (C) Number of Cycles at 60 Hz Figure 1. Derating Curve Output Rectified Current Figure 2. Maximum Non-Repetitive Peak Forward Surge Current Per Diode www.vishay.com 2 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com Document Number: 88656 Revision: 15-Apr-08 KBU4A thru KBU4M Vishay General Semiconductor 150 Junction Capacitance (pF) Instantaneous Forward Current (A) 100 10 TJ = 25 C Pulse Width = 300 s 1 % Duty Cycle 1 0.1 0.6 TJ = 25 C f = 1.0 MHz Vsig = 50 mVp-p 100 75 50 25 0 0.8 0.7 0.9 1.0 1.1 1.2 1 0.1 1.3 10 100 Instantaneous Forward Voltage (V) Reverse Voltage (V) Figure 3. Typical Forward Characteristics Per Diode Figure 5. Typical Junction Capacitance Per Diode Instantaneous Reverse Current (A) 50 10 TJ = 100 C 1 0.1 TJ = 25 C 0.01 0 20 40 60 80 100 Percent of Rated Peak Reverse Voltage (%) Figure 4. Typical Reverse Leakage Characteristics Per Diode PACKAGE OUTLINE DIMENSIONS in inches (millimeters) Case Style KBU 0.935 (23.7) 0.895 (22.7) 0.160 (4.1) 0.140 (3.6) 0.760 (19.3) MAX. 0.185 (4.7) 0.165 (4.2) 45 0.085 (2.2) 0.065 (1.7) 0.700 (17.8) 0.660 (16.8) 0.455 (11.3) 0.405 (10.3) 0.075 (1.9) R TYP. (2 Places) 1.0 (25.4) MIN. 0.052 (1.3) 0.048 (1.2) DIA. 0.220 (5.6) 0.180 (4.6) 0.240 (6.09) 0.200 (5.08) 0.205 (5.2) 0.185 (4.7) Document Number: 88656 Revision: 15-Apr-08 0.280 (7.1) 0.260 (6.6) For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com www.vishay.com 3 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000