www.tracopower.com Page 1 of 4
DC/DC Converters
THN 30WI Series, 30 Watt
Features
Highest power density 30W converter!
Ultra compact size: 1.0” x 1.0” x 0.4
Shielded metal case with isolated
baseplate
Ultrawide 4:1 input voltage range
Very high efficiency across full load range
up to 92%
No minimum load required
Remote On/Off control
Operating temp. range –40°C to +80°C
and up to 85 °C with heat-sink
Over temperature protection
Output voltage adjustable
I/O isolation voltage 1500 VDC
RoHS 2011/65/EU compliant
3-year product warranty
The THN 30WI series is the latest generation of high performance DC/DC converter
modules with highest power density. The product achieves 30W output power while
it comes in a metal case with dimensions of only 1.0x 1.0x 0.4”.
All models have an ultra wide 4:1 input voltage range and precisely regulated
output voltages, even under no load conditions. Highest efficiency across full load
range makes this product very reliable and applicable in temperature ranges of up
to 85°C. With a low input current at minimal load and remote On/Off control these
converters are the ideal solution for battery-operated systems. Typical applications
are in mobile equipments, instrumentation, distributed power architectures in com-
munication and industrial electronics and everywhere where space on the PCB is
critical.
Order code Input voltage range Output voltage Output current max. Efficiency typ.
THN 30-2410WI 3.3 VDC 7000 mA 86 %
THN 30-2411WI 5.0 VDC 6000 mA 89 %
THN 30-2411WI-A1 5.0 VDC *16000 mA 89 %
THN 30-2412WI 12 VDC 2500 mA 89 %
THN 30-2413WI 9 – 36 VDC 15 VDC 2000 mA 89 %
THN 30-2415WI (24 VDC nominal) 24 VDC 1250 mA 89 %
THN 30-2425WI *2 48 VDC 625 mA 91 %
THN 30-2422WI ±12 VDC ±1250 mA 89 %
THN 30-2423WI ±15 VDC ±1000 mA 91 %
THN 30-2425WI ±24 VDC ±625 mA 91 %
THN 30-4810WI 3.3 VDC 7000 mA 87 %
THN 30-4811WI 5.0 VDC 6000 mA 90 %
THN 30-4811WI-A1 5.0 VDC *16000 mA 90 %
THN 30-4812WI 12 VDC 2500 mA 90 %
THN 30-4813WI 18 – 75 VDC 15 VDC 2000 mA 91 %
THN 30-4815WI (48 VDC nominal) 24 VDC 1250 mA 91 %
THN 30-4825WI *2 48 VDC 625 mA 91 %
THN 30-4822WI ±12 VDC ±1250 mA 91 %
THN 30-4823WI ±15 VDC ±1000 mA 92 %
THN 30-4825WI ±24 VDC ±625 mA 92 %
Models
CB
Scheme
UL 60950-1UL 60950-1
*1 Adjustable output up to 6 VDC
*2 This dual ±24 VDC converter can be used as single 48 VDC converter (open common contact)
www.tracopower.com Page 2 of 4
DC/DC Converters
THN 30WI Series 30 Watt
Input Specifications
Input current at no load (at nominal input voltage) 24 Vin models: 10 mA typ.
48 Vin models: 8 mA typ.
Start-up voltage 24 Vin models: < 9.0 VDC
48 Vin models: < 18 VDC
Under voltage shut down (lock-out circuit) 24 Vin models: 8.0 VDC typ.
48 Vin models: 16 VDC typ.
Surge voltage (1 sec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 30 mAp-p typ.
Conducted noise (input) EN 55032 class A and B (with external components)
– Filter proposal for compling to class A/B www.tracopower.com/overview/thn30wi
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV perf. criteria A
With external input capacitor e.g. Nippon
chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Recommended input fuse (slow blow) 24 Vin models: 6300 mA
48 Vin models: 3150 mA
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment range 5.0 Vout A1 models: 10 % to +20%
15 & 24 Vout models: 10 % to +20%
other single output models: ±10 %
– For further information see application note www.tracopower.com/overview/thn30wi
Regulation – Input variation (Vmin – Vmax) single output models: 0.2 % max.
dual output models: 0.5 % max.
– Load variation (0 – 100 %) single output models: 0.2 % max.
dual output models balanced load: 1.0 % max.
dual output models unbalanced load (25% /100%): 5.0 % max.
Minimum load not required
Ripple and noise (measured with output capacitor) 3.3 & 5.0 Vout models: 75 mVp-p with (22µF/25V X7R 1812 MLCC)
(20 MHz bandwidth) 12 & 15 Vout models: 75 mVp-p with (2x 22µF/25V X7R 1812 MLCC)
24 Vout models: 75 mVp-p with (2x 6.F/50V X7R 1812 MLCC)
dual output models: 60 mVp-p with (1F/50V X7R 1812 MLCC)
Temperature coefficient ±0.02 %/K
Output current limitation at 170 % of Iout max.
Short circuit protection hiccup, automatic recovery
Over voltage protection 3.3 Vout models: 3.7 – 5.4 VDC
5.0 Vout models: 5.6 – 7.0 VDC
5.0 Vout A1 models: 6.3 – 7.4 VDC
12 Vout models: 13.5 – 19.6 VDC
15 Vout models: 18.3 – 22.0 VDC
24 Vout models: 29.1 – 32.5 VDC
Start up time (nominal Vin and constant resistive load) 30 ms max. (for power on and remote on)
Transient response setting time 250 µs typ. (25% load step change)
www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THN 30WI Series 30 Watt
General Specifications
Temperature ranges – Operating without heat sink –40°C to +80°C (with derating)
– Operating with heat sink –40°C to +85°C (with derating)
– Case temperature +105°C max.
– Storage –55°C to +125°C
Power derating – Operating without heat sink 2.2 %/K above +55°C
– Operating with heat sink 2.5 %/K above +60°C
Thermal impedance – Natural convection 15.0°C/W
– Natural convection with heat sink 13.8°C/W
Thermal protection shutdown at 115°C
Humidity (non condensing) 5 % to 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +70°C, ground benign) 1.2 Mio. h
Isolation voltage (60sec.) – Input/Output 1500 VDC
– Input, Output/Case 1000 VDC
Isolation capacitance – Input/Output 1500 pF max.
Isolation resistance – Input/Output (500 VDC) >1 GOhm
Remote On/Off – On: 3.0 to 15 VDC or open circuit
– Off: 0 to 1.2 VDC or short circuit pin 6 and pin 2
– Off idle current: 2.0 mA
Switching frequency (fixed, pulse width modulation) 3.3 & 5.0 Vout models: 275 kHz ±10%
other models: 330 kHz ±10%
Vibration and thermal shock MIL-STD-810F
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
Safety approvals – Online certification for UL/cUL 60950-1 www.ul.com -> certifications -> File e188913
copy: QQGQ2 (USA) QQGQ8 (Canada)
– Certification documents www.tracopower.com/overview/thn30wi
Physical Specifications
Casing material copper
Baseplate non conductive FR4
Potting material silicone (UL 94V-0 rated)
Weight 16.5 g (0.58oz)
Soldering temperature max. 265°C / 10sec.
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Application note: www.tracopower.com/overview/thn30wi
Output Specifications (continued)
Max. capacitive load 3.3 Vout models: 10’000 µF
5 Vout models: 7’200 µF
12 Vout models: 1’200 µF
15 Vout models: 1000 µF
24 Vout models: 375 µF
±12 Vout models: 750 µF (each output)
±15 Vout models: 500 µF (each output)
±24 Vout models: 180 µF (each output)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Page 4 of 4
DC/DC Converters
THN 30WI Series 30 Watt
Outline Dimensions
Dimensions in [mm], () = Inch
Pin diameter ø 1.0 (0.04)
Pin pitch tolerances: ±0.25 (±0.01)
Tolerances: ±0.5 (±0.02)
Rev. March 27. 2018
Pin Single Dual
1+Vin (Vcc) +Vin (Vcc)
2–Vin (GND) –Vin (GND)
3+Vout +Vout
4Trim Common
5–Vout –Vout
6Remote On/Off
Pin-Out
Note:
The product label on converter has to be re-
moved before mounting the heat-sink.
For volume orders converters will be sup-
plied with heat-sink already mounted. Please
contact factory for quotation.
Separate heat-sinks are only available for
prototypes and small quantity orders.
Order code: THN-HS1
(cont.: heat-sink, thermal pad, 2 clamps)
Material: Aluminum
Finish: Anodic treatment (black)
Weight: 8 g (0.28oz) without converter
Thermal impedance after assembling: 13.8 K/W
Heat-Sink (Option)
31.0 (1.22) max.
14.5 (0.57)
16.5 (0.65)
max.
Converter
Heat-sink
Thermal pad
Clamp
25.4
25.4
Bottom view
20.32
7.62
5.6
(0.3)
(0.22)
(0.8)
(1.0)
(1.0)
5.08
(0.2)
9.9
(0.39)
1
2
3
6
5
2.5
(0.1)
4
10.16
(0.4)
2.5
(0.1)
10.16
(0.4)