PRCP-RX/72 Series - Polymer Resettable Circuit Protectors
Electrical Characteristics
Features
72 V rated
Radial leaded devices
Cured, flame retardant epoxy polymer
insulating material meets
UL 94V-0 requirements
RoHS compliant*
Agency recognition:
Applications
Almost anywhere there is a low voltage
power supply, up to 72 V and a load to be
protected, including:
Security and fire alarm systems
Loudspeakers
Power transformers
1 Hour (R1)Max. Time Tripped
Ihold Itrip Initial Post-Trip To Trip Power
Resistance noitapissiDecnatsiseR
Model Amperes Ohms Ohms Amperes Seconds Watts
V max. I max.
at 23 oCat23
oCat23
oCat23
oCat23
oCat23
oC
Volts Amps
.pyT.xaM.xaM.niMpirTdloH
PRCP-RX020/72 72 40 0.20 0.40 1.50 2.84 4.40 1.0 2.2 0.40
PRCP-RX025/72 72 40 0.25 0.50 1.00 1.95 3.00 1.25 2.5 0.45
PRCP-RX030/72 72 40 0.30 0.60 0.76 1.36 2.10 1.5 3.0 0.50
PRCP-RX040/72 72 40 0.40 0.80 0.52 0.86 1.29 2.0 3.9 0.55
PRCP-RX050/72 72 40 0.50 1.00 0.41 0.77 1.17 2.5 4.0 0.75
PRCP-RX065/72 72 40 0.65 1.30 0.27 0.48 0.72 3.25 5.3 0.90
PRCP-RX075/72 72 40 0.75 1.50 0.18 0.40 0.60 3.75 6.3 0.90
PRCP-RX090/72 72 40 0.90 1.80 0.14 0.31 0.47 4.5 7.2 1.00
PRCP-RX110/72 72 40 1.10 2.20 0.15 0.25 0.38 5.5 8.2 1.50
PRCP-RX135/72 72 40 1.35 2.70 0.12 0.19 0.30 6.75 9.6 1.70
PRCP-RX160/72 72 40 1.60 3.20 0.09 0.14 0.22 8.0 11.4 1.90
PRCP-RX185/72 72 40 1.85 3.70 0.08 0.12 0.19 9.25 12.6 2.10
PRCP-RX250/72 72 40 2.50 5.00 0.05 0.08 0.13 12.5 15.6 2.50
PRCP-RX300/72 72 40 3.00 6.00 0.04 0.06 0.10 15.0 19.8 2.80
PRCP-RX375/72 72 40 3.75 7.50 0.03 0.05 0.08 18.75 24.0 3.20
Operating/Storage Temperature ........................-40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................125 °C
Passive Aging......................................................+85 °C, 1000 hours ....................................±5 % typical resistance change
Humidity Aging....................................................+85 °C, 85 % R.H. 1000 hours ..................±5 % typical resistance change
Thermal Shock ....................................................+85 °C to -55 °C, 10 times ........................±10 % typical resistance change
Solvent Resistance ............................................MIL-STD-202, Method 215 ........................No change
Vibration ..............................................................MIL-STD-883C, Method 2007.1, ................No change
Condition A
Environmental Characteristics
airetirCtcejeR/tpeccAsnoitidnoCtseTtseT
Visual/Mech. ......................................................Verify dimensions and materials ................Per PRCP physical description
Resistance ..........................................................In still air @ 23 °C........................................Rmin bRbRmax
Time to Trip ........................................................5 times Ihold, Vmax, 23 °C ........................T bmax. time to trip (seconds)
Hold Current ......................................................30 min. at Ihold ..........................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
Test Procedures And Requirements For Model PRCP-RX/72 Series
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
COPAL ELECTRONICS
8
UL File Number ..................................................E300792
TÜV Certificate Number...........................................R 50075506
CSA File Number ....................................................CA1730526