55M0411 Issue 21 4th November 2009 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only WIRE, MODIFIED FLUOROPOLYMER INSULATED, 450 VOLT, 150C, LIGHTWEIGHT The complete requirements for procuring the wire described herein shall consist of this document. Conductor Tin Plated Copper C6 Insulation Radiation Crosslinked Modified ETFE C7 Part Description C8 C9 C11 Conductor C16 C17 C18 C19 FINISHED WIRE Stranding Diameter Max. Resistance Diameter No./ Diam. (mm) @ 20C (mm) Maximum Weight (mm) Min. Max. (ohms/km) Min. Nom. Max. (kg/km) 55M0411-30-* 7/010 0.29 0.31 347.0 0.46 0.51 0.56 0.83 55M0411-28-* 7/0.13 0.36 0.38 220.0 0.54 0.59 0.64 1.17 55M0411-26-* 19/0.10 0.46 0.48 133.0 0.64 0.69 0.74 1.83 55M0411-24-* 19/0.13 0.58 0.61 83.3 0.77 0.82 0.87 2.71 55M0411-22-* 55M0411-20-* 19/0.15 19/0.20 0.72 0.95 0.74 0.97 55.0 31.1 0.90 1.12 0.95 1.18 1.00 1.26 3.84 6.38 COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code designator in accordance with Mil Std 681. e.g. 55M0411-24-9 Size 24, White insulation PERFORMANCE REQUIREMENTS To be tested and released to the issue in effect of Raychem Specification 55A ADDITIONAL REQUIREMENTS Minimum wall thickness 0.085mm Routine Ageing test at 200 C for 7 hours using weights and mandrels as per 55A0111 SCD. APPROVAL: Electronic sign off - no signatures will appear. (c)2009 Tyco Electronics Corporation. All International Rights Reserved.