55M0411
Issue 21
4th November 2009
Page 1 of 2
Page 2 is for internal use only
WIRE, MODIFIED FLUOROPOLYMER INSULATED, 450 VOLT, 150°C, LIGHTWEIGHT
The complete requirements for procuring the wire described herein shall consist of this document.
Conductor -
Insulation -
Tin Plated Copper Radiation Crosslinked
Modified ETFE
C6
C7
C8
C9
C11
C16
C17
C18
C19
Part
Description Stranding Max. Resistance Maximum
No./ Diam. @ 20°C Weight
(mm) Min. Max. (ohms/km) Min. Nom. Max. (kg/km)
55M0411-30-* 7/010 0.29 0.31 347.0 0.46 0.51 0.56 0.83
55M0411-28-* 7/0.13 0.36 0.38 220.0 0.54 0.59 0.64 1.17
55M0411-26-* 19/0.10 0.46 0.48 133.0 0.64 0.69 0.74 1.83
55M0411-24-* 19/0.13 0.58 0.61 83.3 0.77 0.82 0.87 2.71
55M0411-22-* 19/0.15 0.72 0.74 55.0 0.90 0.95 1.00 3.84
55M0411-20-* 19/0.20 0.95 0.97 31.1 1.12 1.18 1.26 6.38
COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code designator in
accordance with Mil Std 681.
e.g. 55M0411-24-9 Size 24, White insulation
PERFORMANCE To be tested and released to the issue in effect of Raychem Specification 55A
REQUIREMENTS
ADDITIONAL Minimum wall thickness 0.085mm
REQUIREMENTS Routine Ageing test at 200 °C for 7 hours using weights and mandrels as per
55A0111 SCD.
APPROVAL: Electronic sign off - no signatures will appear.
©2009 Tyco Electronics Corporation. All International Rights Reserved.
Specification Control Drawing
Conductor
Diameter FINISHED WIRE
Diameter
(mm) (mm)