Extractor Tool for CMX Receptacle Connector Extractor Tool Application Tooling Specification Sheet Order No. 63824-0100 FEATURES This Extractor Tool is for opening the Secondary Lock from CMX Receptacle 53 Way, 198009 Series. This Tool will also assist in closing the secondary lock. SCOPE Products: CMX Receptacle Connector Assembly, 53 Way, Right and Left Slide Orientation. Housing Series No 198009 Housing Order No. 198009-1001 198009-1002 198009-1003 198009-1004 198009-2001 198009-2002 198009-2003 198009-2004 OPERATION: Opening the (TPA) Secondary Lock On a CMX receptacle assembly follow the steps below: 1. Insert the extractor tool into the (2) side slots of the (TPA) secondary lock on each sides until it stops. See Figure 1. 2. While keeping the extractor tool in this position pull down on the sides of the (TPA) secondary lock without touching the latches. The locking latches should be visible. See Figure 2. 3. Remove the extractor tool and check the position of the TPA. TPA SECONDARY LOCK CLOSED TPA SECONDARY LOCK OPEN SLOTS TPA SECONDARY LOCKING LATCHES (BOTH SIDES) SLOTS EXTRACTOR TOOL Doc No: ATS-638240100 Revision: E LOCKING LATCHES OPEN (BOTH SIDES) Figure 1 EXTRACTOR TOOL Release Date: 07-14-10 Revision Date: 06-06-12 Figure 2 UNCONTROLLED COPY Page 1 of 2 Extractor Tool for CMX Receptacle Connector Closing the (TPA) secondary lock On a CMX receptacle assembly, follow the steps below: Secondary lock can be closed manually or during the final connector check. This procedure is done after the insertion of all female terminals. 1. Insert the extractor tool into the (2) side slots of the (TPA) secondary lock on each sides. See Figure 3. 2. Push up on the extract tool until the TPA contacts with the edge of the seal and the locking latches click in place. 3. Make sure there is no space between the TPA and the seal. See Figure 4. 4. Remove the extractor tool. Note: One of the functions of the secondary lock (TPA) is to detect if any of the terminals are not fully seated in the cavities. If the secondary lock does not close, reopen the TPA. Push on the terminals one at a time to make sure they are locked in place. Close the secondary lock see step 2 and 3. Check visually the locking latches are in the correct position. SEAL PROTECTED BY A MOVEABLE SKIRT LOCKING LATCHES OPEN (BOTH SIDES) LOCKING LATCHES CLOSED (BOTH SIDES) THE TOOL FINGERS BOTTOM STOP SHOULD BE IN CONTACT WITH THE TPA BEFORE PUSHING ON THE TPA Figure 4 TPA SECONDARY LOCK OPEN TPA SECONDARY LOCK CLOSED Figure 3 EXTRACTOR TOOL THERE SHOULD BE A SMALL GAP BETWEEN THE BOTTOM STOP OF THE TOOL FINGERS AND THE TPA Molex does not offer repair parts for Extractor Tools due to the inexpensive nature of these tools. CAUTION: Molex specifications are valid only when used with Molex terminals and tooling. http://www.molex.com Doc No: ATS-638240100 Revision: E Release Date: 07-14-10 Revision Date: 06-06-12 UNCONTROLLED COPY Page 2 of 2