22 Series - Modular contactors 25 - 40 - 63 A Features 22.32.0.xxx.1xx0 22 SERIES 22.32.0.xxx.4xx0 25 A modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break * Continuous duty for the coil and contacts * AC/DC silent coil (with varistor protection) * Protective separation (reinforced insulation) between coil and contacts * Mechanical and LED indicators as standard * Auto-On-Off selector version available * AgNi and AgSnO2 contact versions available * Compliant with EN 61095: 2009 * Auxiliary contact module available, quick-assembly with the main contactor (1 NO + 1 NC and 2 NO versions) * 35 mm rail (EN 60715) mount * * * AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads * AgSnO2 contacts, specifically intended for lamp loads and for high inrush current loads 22.32...1xx0 / 22.32...4xx0 Screw terminal 2 NO (x3x0) For outline drawings see page 8 1 NO + 1 NC (x5x0) 2 NC (x4x0) Contact specification Contact configuration 2 NO, 3 mm * (or 1 NO + 1 NC or 2 NC) Rated current/Maximum peak current A Rated voltage V AC Rated load AC1 / AC-7a (per pole @ 250 V) VA Rated current AC3 / AC-7b A 25 / 80 25 / 120 250 / 440 250 / 440 6,250 6,250 10 10 1,800 1,800 Rated load AC15 (per pole @ 230 V) VA Single-phase motor rating (230 V AC) kW 1 1 Rated load AC5a (per pole @ 250 V) A 15 15 Rated current AC-7c A -- 10 230V incandescent/halogen W 800 2,000 * Contact gap 3 mm for NO contacts only; NC contacts 1.5 mm Nominal lamp rating: fluorescent tubes with electronic ballast W 300 800 fluorescent tubes with electromechanical ballast W 200 500 CFL W 100 200 230V LED W 100 200 LV halogen or LED with electronic ballast W 100 200 LV halogen or LED with electromechanical ballast W 300 800 25/5/1 25/5/1 1,000 (10/10) 1,000 (10/10) AgNi AgSnO2 12 - 24 - 48 - 60 - 120 - 230 12 - 24 - 48 - 60 - 120 - 230 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Contact material Coil specification Nominal voltage (UN) V DC/AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 2 /2.2 2 / 2.2 DC/AC (50/60 Hz) (0.8...1.1) UN (0.8...1.1) UN Holding voltage DC/AC (50/60 Hz) 0.4 UN 0.4 UN Must drop-out voltage DC/AC (50/60 Hz) 0.1 UN 0.1 UN Mechanical life AC/DC cycles 2 * 106 2 * 106 Electrical life at rated load AC-7a Operating range L IV-2015, www.findernet.com Technical data Operate/release time cycles 70 * 10 3 30 * 103 ms 30 / 20 30 / 20 6 6 -20...+50 -20...+50 IP20 IP20 Insulation between coil and contacts (1.2/50 s) kV Ambient temperature range Protection category C Approvals (according to type) 1 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Features 22.34.0.xxx.1xx0 22.34.0.xxx.4xx0 25 A modular contactor - 4 pole 35 mm wide NO contact gap 3 mm, double break * Continuous duty for the coil and contacts * AC/DC silent coil (with varistor protection) * Protective separation (reinforced insulation) between coil and contacts * Mechanical and LED indicators as standard * Auto-On-Off selector version available * AgNi and AgSnO2 contact versions available * Compliant with EN 61095: 2009 * Auxiliary contact module available, quick-assembly with the main contactor (1 NO + 1 NC and 2 NO versions) * 35 mm rail (EN 60715) mount * * * AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads * AgSnO2 contacts, specifically intended for lamp loads and for high inrush current loads 22.34...1xx0 / 22.34...4xx0 Screw terminal 4 NO (x3x0) For outline drawings see page 8 3 NO + 1 NC (x7x0) 2 NO + 2 NC (x6x0) Contact specification Contact configuration 4 NO, 3 mm * (or 3NO + 1NC or 2NO + 2NC) Rated current/Maximum peak current A Rated voltage V AC Rated load AC1 / AC-7a (per pole @ 250 V) VA Rated current AC3 / AC-7b A Rated load AC15 (per pole @ 230 V) VA Three-phase motor rating (400 - 440 V AC) kW 25 / 80 25 / 120 250 / 440 250 / 440 6,250 6,250 10 10 1,800 1,800 4 4 Rated load AC5a (per pole @ 250 V) A 15 15 Rated current AC-7c A -- 10 230V incandescent/halogen W 800 2,000 * Contact gap 3 mm for NO contacts only; NC contacts 1.5 mm Nominal lamp rating: fluorescent tubes with electronic ballast W 300 800 fluorescent tubes with electromechanical ballast W 200 500 CFL W 100 200 230V LED W 100 200 LV halogen or LED with electronic ballast W 100 200 LV halogen or LED with electromechanical ballast W 300 800 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Contact material 25/5/1 25/5/1 1,000 (10/10) 1,000 (10/10) AgNi AgSnO2 12 - 24 - 48 - 60 - 120 - 230 12 - 24 - 48 - 60 - 120 - 230 Coil specification Nominal voltage (UN) V DC/AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 2 / 2.2 2 / 2.2 DC/AC (50/60 Hz) (0.8...1.1) UN (0.8...1.1) UN Holding voltage DC/AC (50/60 Hz) 0.4 UN 0.4 UN Must drop-out voltage DC/AC (50/60 Hz) 0.1 UN 0.1 UN Mechanical life AC/DC cycles 2 * 106 Electrical life at rated load AC-7a cycles 150 * 10 ms 18 / 40 18 / 40 6 6 -20...+50 -20...+50 IP20 IP20 Operating range Technical data Operate/release time Insulation between coil and contacts (1.2/50 s) kV Ambient temperature range Protection category Approvals (according to type) 2 C 2 * 106 3 30 * 103 IV-2015, www.findernet.com L 22 Series - Modular contactors 25 - 40 - 63 A Features 22.44.0.xxx.4xx0 22 SERIES 22.64.0.xxx.4xx0 40 - 63 A modular contactor - 4 pole NO and NC contact gap 3 mm, double break Continuous duty for the coil and contacts * AC/DC silent coil (with varistor protection) * Protective separation (reinforced insulation) between coil and contacts * Mechanical indicator as standard * AgSnO2 contacts * Compliant with EN 61095: 2009 and with EN 60947-4-1: 2009 * 35 mm rail (EN 60715) mount * * For high inrush current loads 176 A * Contact material AgSnO2 * 22.44.../22.64... Screw terminal 4 NO (4310) For outline drawings see page 8 Specifically intended: for high inrush current loads 240 A * Contact material AgSnO2 * 3 NO + 1 NC (4710) 2 NO + 2 NC (4610) Contact specification Contact configuration 4 NO, (or 3NO + 1NC or 2NO + 2NC) 3 mm Rated current/Maximum peak current A Rated voltage V AC Rated load AC1 / AC-7a (per pole @ 400 V) VA Rated current AC3 / AC-7b (400 V) 40 / 176 63 / 240 400 / 440 400 / 440 16,000 24,000 A 22 30 VA -- -- Three-phase motor rating (400 - 440 V AC) kW 11 15 Rated load AC5a (per pole @ 250 V) A 20 32 Rated current AC-7c A -- -- 230V incandescent/halogen W 4,000 5,000 Rated load AC15 (per pole @ 230 V) Nominal lamp rating: fluorescent tubes with electronic ballast W 1,500 2,000 fluorescent tubes with electromechanical ballast W 1,500 2,000 CFL W 1,000 1,500 230V LED W 1,000 1,500 LV halogen or LED with electronic ballast W 1,000 1,500 LV halogen or LED with electromechanical ballast W 1,500 2,000 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Contact material 40/4/1.2 63/4/1.2 1,000 (17/50) 1,000 (17/50) AgSnO2 AgSnO2 Coil specification Nominal voltage (UN) V DC/AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 12 - 24 - 110...120 (110 V DC) - 230...240 (220 V DC) 5 5 DC/AC (50/60 Hz) (0.85...1.1) UN (0.85...1.1) UN Holding voltage DC/AC (50/60 Hz) 0.85 UN 0.85 UN Must drop-out voltage DC/AC (50/60 Hz) 0.2 UN 0.2 UN Mechanical life AC/DC cycles 3 * 106 Electrical life at rated load AC-7a cycles 100 * 10 100 * 103 ms 20 / 45 20 / 45 6 6 -5...+55 -5...+55 IP20 IP20 Operating range L IV-2015, www.findernet.com Technical data Operate/release time Insulation between coil and contacts (1.2/50 s) kV Ambient temperature range Protection category C 3 * 106 3 Approvals (according to type) 3 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Ordering information Exemple: 22 series, modular contactor 25 A, 4 NO contacts, coil 230 V AC/DC, AgSnO2 contacts, Auto-On-Off selector + mechanical indicator + LED. 2 2 . 3 A B C D 4 . 0 . 2 3 0 . 4 3 4 0 D: Special versions 0 = Standard Series Type 3 = 25 A modular contactor range 4 = 40 A modular contactor range 6 = 63 A modular contactor range C: Options 1 = Mechanical indicator 2 = Mechanical indicator + LED 4 = Auto-On-Off selector + mechanical indicator + LED Number of contacts 2 = 2 pole 4 = 4 pole B: Contact circuit 3 = All NO contacts 4 = All NC contacts (22.32 only) 5 = 1 NO + 1 NC 6 = 2 NO + 2 NC 7 = 3 NO + 1 NC Coil version 0 = AC (50/60 Hz)/DC Coil rated voltage See coil specifications A: Contact material 1 = AgNi 4 = AgSnO2 Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B 22.32 22.34 22.44 22.64 AC/DC AC/DC AC/DC AC/DC 1-4 1-4 4 4 3 3 3 3 - 4 6 6 6 - 5 7 7 7 C D 2-4 2-4 1 1 0 0 0 0 Options Auto-On-Off selector + mechanical indicator + LED (xx40 option) Type 22.32 / 22.34 Options 1 1 Selector The three-position manual selector has the following functions: * ON position - the contacts are latched in the operated state (NO contacts - closed and NC contacts - open), the mechanical indicator is visible in its window, the LED is not illuminated. * AUTO position - the state of contacts, mechanical indicator and LED follow the coil supply voltage. 3 2 * OFF position - even if terminals A1 - A2 are supplied with rated voltage, the coil is not energized, and so the contacts remain in the non-operated state, the mechanical indicator is not visible and the LED is not illuminated. 2 LED 3 Mechanical indicator Type 22.44 / 22.64 Options 1 Mechanical indicator 1 4 IV-2015, www.findernet.com L 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Technical data Insulation 22.32 / 22.34 Rated insulation voltage V AC Pollution degree 22.44 / 22.64 250 440 440 3* 2 3 Insulation between coil and contact set Type of insulation Reinforced Reinforced Overvoltage category III III 6 4 4,000 2,000 Type of insulation Basic Basic Overvoltage category III III 4 4 Rated impulse voltage kV (1.2/50 s) Dielectric strength V AC Insulation between adjacent contacts Rated impulse voltage kV (1.2/50 s) Dielectric strength V AC Insulation between open contacts Contact gap mm Overvoltage category Rated impulse voltage Dielectric strength kV (1.2/50 s) V AC/kV (1.2/50 s) 2,500 2,000 NO contact NC contact NO/NC contacts 3 1.5 3 III II III 4 2.5 4 2,500/4 2,000/3 2,000/3 * Only for versions without Auto-On-Off selector. For versions with Auto-On-Off selector pollution degree 2 applies. Conducted disturbance immunity Reference standard Fast transients (burst 5/50 ns, 5 kHz) at coil terminals EN 61000-4-4 Level 4 (4 kV) Level 2 (2 kV) Voltage pulses (surge 1.2/50 s) at supply terminals (differential mode) EN 61000-4-5 Level 4 (4 kV) Level 2 (2 kV) Short circuit protection 22.32 / 22.34 22.44 22.64 3 3 3 32 (gL/gG type) 63 80 Rated conditional short circuit current kA Back-up fuse A Terminals Solid and stranded cable mm2 Max. wire size - contact terminals AWG mm2 Max. wire size - coil terminals AWG mm2 Min. wire size - contact and coil terminals AWG Screw torque Wire strip length Shock resistance Power lost to the environment 22.44 / 22.64 1x6/2x4 1x25 (solid) - 1x16 (stranded) 1 x 10 / 2 x 12 1x4 (solid) - 1x6 (stranded) 1 x 4 / 2 x 2.5 1x2.5 1 x 12 / 2 x 14 1x14 1 x 0.2 1x1 (coil) - 1x1.5 (contacts) 1 x 24 1x18 (coil) - 1x16 (contacts) Nm 0.8 1.2 (coil terminals) - 3.5 (contact terminals) mm 9 10 Other data Vibration resistance (10...150)Hz 22.32 / 22.34 22.32 22.34 22.44 22.64 g 4 4 3 3 g 10 10 15 15 without contact current W 2 2 5 5 with rated current 4.8 6.3 17 37 W NOTE 22.32/22.34: It is suggested an air gap of 9 mm between adjacent relays for installations and working conditions close to the limit (that is, ambient temperature > 40 C, coil operated for a prolonged period of time, all contacts loaded with current > 20 A). IV-2015, www.findernet.com 22.44/22.64: The maximum ambient temperature with 3 adjacent contactors is + 40 C; when more than 3 contactors are installed, it is necessary an air gap of 9 mm. With 2 adjacent contactors the maximum ambient temperature is + 55 C; when more than 2 contactors are installed, it is necessary an air gap of 9 mm. 5 L 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Contact specification Ratings and utilization categories according to EN 61095: 2009 Type AC-7a Rated current Rated electrical (A) life (Cycles) 70*103 (NO) 22.32....1xx0 (AgNi contacts) 25 30*103 (NC) 22.32....4xx0 (AgSnO2 contacts) 25 30*103 150*103 (NO) 22.34....1xx0 (AgNi contacts) 25 100*103 (NC) 22.34....4xx0 (AgSnO2 contacts) 25 30*103 22.44....4xx0 40 100*103 22.64....4xx0 63 100*103 Utilization category AC-7b Rated current Rated electrical (A) life (Cycles) AC-7c Rated current Rated electrical (A) life (Cycles) 10 30*103 -- -- 10 30*103 10 30*103 10 30*103 -- -- 10 22 30 3 10 -- -- 30*103 -- -- 30*10 150*103 150*103 Utilization category: AC-7a = Slightly inductive loads (cos=0.8) AC-7b = Motor loads; (cos=0.45, Imaking= 6xIbreaking) AC-7c = Compensated electric discharge lamps (cos=0.9, C= 10 mF/A) H 22 - Maximum DC1 breaking capacity - Type 22.44 / 22.64 DC breaking current (A) DC breaking current (A) H 22 - Maximum DC1 breaking capacity - Type 22.32 / 22.34 type 22.64 type 22.44 DC voltage (V) DC voltage (V) * When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100*103 can be expected. * In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. Coil specifications AC/DC version data (type 22.32) Coil code 0.012 0.024 0.048 0.060 0.120 AC/DC version data (type 22.34) Operating range Umin V 9.6 19.2 38.4 48 88 Umax V 13.2 26.4 52.8 66 138 Rated coil consumption IN at UN (AC) mA 165 83 42 33 16.5 (110...125) 0.230 (220 DC) 184 (AC) 264 (AC) L 0.012 0.024 0.048 0.060 0.120 176 (DC) 242 (DC) 230 8.7 Coil code Operating range 0.012 0.024 0.120 Umin V 10.2 20.4 102 0.230 196 Umax V 13.2 26.4 138 (230...240 AC) (220 DC) AC/DC version data (type 22.44 / 22.64) Nominal voltage UN V 12 24 120 Coil code Operating range Umin V 9.6 19.2 38.4 48 88 Umax V 13.2 26.4 52.8 66 138 Rated coil consumption IN at UN (AC) mA 165 83 42 33 16.5 (110...125) 230 (230...240 AC) Nominal voltage UN V 12 24 48 60 120 0.230 184 (AC) 264 (AC) 176 (DC) 242 (DC) 8.7 R 22 - Coil operating range v ambient temperature Rated coil consumption IN at UN (AC) mA 417 208 41 (110...125) 230 (230...240 AC) (220 DC) 6 264 (AC) 21 242 (DC) 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. IV-2015, www.findernet.com Nominal voltage UN V 12 24 48 60 120 22 Series - Modular contactors 25 - 40 - 63 A 22 SERIES Wiring diagrams Type 22.32 Line and neutral switched Line only switched Type 22.34 Type 22.34 Line and neutral switched Line only switched Type 22.44 / 22.64 Type 22.44 / 22.64 IV-2015, www.findernet.com L 7 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Outline drawings Type 22.32 Screw terminal Type 22.32 + 022.33 / 022.35 Screw terminal Type 22.34 Screw terminal Type 22.34 + 022.33 / 022.35 Screw terminal Type 22.44 / 22.64 Screw terminal Type 22.44 / 22.64 + 022.63 / 022.65 Screw terminal Type 022.33 / 022.35 Screw terminal Type 022.63 / 022.65 Screw terminal IV-2015, www.findernet.com L 8 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Auxiliary modules 022.33 022.35 022.63 022.65 Mechanically linked contacts according to Annex L of EN 60947-5-1 Type of contactor Type 22.32 Type 22.44 Type 22.34 Type 22.64 Contact specification Contact configuration 2 NO 1 NO + 1 NC 2 NO Conventional free air thermal current Ith A 6 6 Rated power AC15 (230 V) 700 Electrical life at rated load Minimum switching load VA 700 cycles 30 x 103 30 x 103 mW (V/mA) 1,000 (10/10) Contact material 1 NO + 1 NC AgNi 1,000 (10/10) AgNi Short circuit protection Rated conditional short circuit current Back-up fuse kA 1 Terminals Max. wire size Min. wire size 1 A 6 (gL/gG type) Solid and stranded cable Screw torque Solid and stranded cable mm2 1 x 4 / 2 x 2.5 1 x 2.5 AWG 1 x 12 / 2 x 14 1 x 14 mm 2 1 x 0.2 1x1 AWG 1 x 24 Wire strip length 6 (gL/gG type) 1 x 18 Nm 0.8 0.6 mm 9 9 Power lost to the environment without contact current W -- -- with rated current W 0.5 0.5 Approvals (according to type) IV-2015, www.findernet.com NOTE: it is not possible to assembly the auxiliary module on 22.32.0.xxx.x4x0 (2 NC versions). 22.32 + 022.33/ 022.35 22.44 + 022.63/ 022.65 22.34 + 022.33/ 022.35 22.64 + 022.63/ 022.65 L 9 22 SERIES 22 Series - Modular contactors 25 - 40 - 63 A Accessories Adaptor for panel mounting (for 22.32 type), plastic, 17.5 mm wide 020.01 Adaptor for panel mounting (for 22.34 type), plastic, 35 mm wide 011.01 Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 Identification tag, plastic, 1 tag, 17x25.5 mm 019.01 Separator for rail mounting, plastic, 9 mm wide 022.09 8-way jumper link for type 22.32, 17.5 mm wide 022.18 (blue) Rated values 10 A - 250 V 6-way jumper link for type 22.34, 35 mm wide 022.26 (blue) Rated values 10 A - 250 V 020.01 011.01 060.72 019.01 P A PEAN N T E O O T EUR EUR 022.09 PEAN P A PEAN N T E PEAN 022.26 10 T EUR EUR O O L IV-2015, www.findernet.com 022.18