http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEN 20WIR Series 20 Watt
Input Specifications
Input current (no load) 24 Vin models: 6 mA typ.
48 Vin models: 4 mA typ.
110 Vin models: 3 mA typ.
Start-up voltage 24 Vin models: 9.0 VDC (or lower)
48 Vin models: 18 VDC (or lower)
110 Vin models: 43 VDC (or lower)
Under voltage shut down (lock-out circuit) 24 Vin models: 8.0 VDC typ.
48 Vin models: 16 VDC typ.
110 Vin models: 40 VDC typ.
Surge voltage (1 sec.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
110 Vin models: 170 V max.
Reflected ripple current 30 mAp-p typ.
Conducted noise 24 & 48 Vin models: EN 55032 class B without external components
110 Vin models: EN 55032 class A without external components
EMC immunity EN 50121-3-2
– ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
– Radiated immunity EN 61000-4-3, 20 V/m, perf. criteria A
– Fast transient / surge (with external input capacitor) EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV perf. criteria A
24 & 48 Vin models:
Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
110 Vin models:
Rubycon BXF series, 100 µF / 250 V
– Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1 %
Voltage adjustment range ±10 % (single output models only)
Regulation – Input variation Vmin - Vmax single output models: 0.2 % max.
dual output models: 0.5 % max.
– Load variation 0 – 100 % single output models: 0.2 % max.
dual output models: 1 % max. (balanced load)
5 % max. (load cross variation 25 % / 100 %)
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz bandwidth, 3.3 & 5.0 VDC models: 75 mVp-p typ.
measured with 1 µF/ 50 V MLCC) other models: 100 mVp-p typ.
Start up time – Power On 30 ms typ.
(constant resistive load) – Remote On 30 ms typ.
Transient response (25% load step change) 250 µs typ.
Short circuit protection indefinite (automatic recovery)
Over load protection 150 % of Iout max. typ.
Over voltage protection (only single output models) 3.3 VDC models: 3.7 – 5.4 V
5 VDC models: 5.6 – 7.0 V
12 VDC models: 13.5 – 19.6 V
15 VDC models: 16.8 – 20.5 V