SINGLE PHASE 25.0 AMP BRIDGE RECTIFIERS
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
.375"(9.5mm) Lead Length at Tc=100 C (With heatsink)
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 3.0A D.C.
Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=125 C
GBJ2501 GBJ2502 GBJ2503 GBJ2504 GBJ2505 GBJ2506 GBJ2507 UNITS
50 100 200 400 600 800 1000 V
50 100 200 400 600 800 1000 V
35 70 140 280 420 560 700
350
10
0.6
85
500
-55 +150
-55 +150
V
A
V
mA
mA
GBJ2501 THRU GBJ2507
1.05
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
25.0 Amperes
Dimensions in inches and (millimeters)
Storage Temperature Range, TSTG
Operating Temperature Range, TJ
C
C
C/W
PF
Typical Thermal Resistance RqJC (Note 2)
Typical Junction Capacitance (Note 1)
NOTES:
1. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
2. Thermal Resistance from Junction to Case with device mounted on 300mm x 300mm x 1.6mm Cu Plate Heatsink.
GBJ
.303(7.7)
.287(7.3)
.402(10.2)
.386(9.8)
.303(7.7)
.287(7.3)
.150(3.8)
.134(3.4)
.203(5.2)
.189(4.8)
.800(20.3)
.776(19.7)
.441(11.2)
.425(10.8)
.708(18.0)
.669(17.0)
.165(4.2)
.150(3.8)
.134(3.4)
.122(3.1)
.043(1.1)
.035(0.9)
.094(2.4)
.078(2.0)
1.193(30.3)
1.169(29.7)
+
.189
(4.8)
.114(2.9)
.098(2.5)
.031(0.8)
.023(0.6)
SPACING
~~
Maximum Average Forward (with heatsink Note 2)
4.2
25.0
A
A
FEATURES
* Ideal for printed circuit board
* Low forward voltage
* Mounting position: Any
* Low leakage current
0.1
1.0
.01
10
50
RATING AND CHARACTERISTIC CURVES (GBJ2501 THRU GBJ2507)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
3.0
0.1
1.0
.01
10
50
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V)
Pulse Width 300us
1% Duty Cycle
0 .2 .4 .6 .8 1.0 1.2 1.4
3.0
REVERSE LEAKAGE CURRENT, (mA)
Tj=100 C
Tj=25 C
Tj=25 C
20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
0
FIG.1-TYPICAL FORWARD CURRENT
AVERAGE FORWARD CURRENT,(A)
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
DERATING CURVE
0 20 40 60 80 100 120 140 160
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
200
100
300
500
400
NUMBER OF CYCLES AT 60Hz
1 10
5 50 100
Tj=25 C 8.3ms Single Half
Sine Wave
JEDEC method
25
20
15
10
5
PEAK FORWARD SURGE CURRENT,(A)
0
CASE TEMPERATURE,( C)
WITHOUT HEATSINK