System pro M compact Technical data System Navigate pro MDocument compact (R) Miniature circuit-breakers S 200/S 200 M Residual-current-operated circuit-breakers F 200 Cross wiring/accessories 1 System pro M compact (R) Miniature circuit-breaker S 201 Standard Terms for Delivery and Sale For domestic business, the Standard Terms for Delivery of Products and Services of the Electrical Industry (ABB Form 2292) shall apply in connection with the Standard Sales Terms (ABB Form 2327) in their then applicable version. For foreign business, the Standard Terms for Delivery of Products and Services of the Electrical Industry (ABB Form 2293 GermanEnglish, or ABB Form 2294 German- French) shall apply in connection with the Standard Sales Terms (ABB-Form 2381 English) in their then applicable version. Warranty We assume warranty in accordance with the standard sales and delivery terms. Complaints shall be made in writing within eight days following receipt of the goods. Technical information and illustrations are not binding and subject to change without notice. 2 System pro M compact (R) Miniature circuit-breakers Residual-current-operated circuit breaker Busbars Contents page The technology of S 200 Notes for use, special features ............................................................................ The offer at a glance ............................................................................................. Overview of technical data ................................................................................... Internal resistance and power loss ...................................................................... Max. permissible impedances of fault loops ....................................................... Tripping charakteristics ........................................................................................ Short circuit capacity ........................................................................................... Short circuit selectivity ....................................................................................... Tripping diagrams ................................................................................................ Let-through value diagrams ................................................................................. Current-carrying capacity, thermal influence ...................................................... Applications S 200 ............................................................................................... Installation and operation instructions S 200 ...................................................... Supplementary devices ........................................................................................ Dimensions ........................................................................................................... Dimension drawings accessories ........................................................................ 4 6 7 8 8 9 9 10 11 13 14 15 16 17 25 26 The technology of F 200 Supplementary devices ........................................................................................ Description, Application examples ...................................................................... Technical data ...................................................................................................... Installation and operation instructions F 200 ...................................................... Use in different types of circuit ............................................................................ Dimension drawings ............................................................................................. Dimension drawings accessories ........................................................................ 17 20 21 22 23 26 27 The technology of busbars Description ........................................................................................................... 24 Technical data ...................................................................................................... 24 Dimensions ........................................................................................................... 27 The program Prior to connection of aluminium conductors ( 4 mm2) ensure that their contact points are cleaned, brushed and coated with grease. Selection table S 200-B ....................................................................................... 29 Selection table S 200-C ....................................................................................... 31 Selection table S 200-D ....................................................................................... 33 Selection table S 200-K ....................................................................................... 35 Selection table S 200-Z ....................................................................................... 37 Selection table S 200-K H .................................................................................... 39 Selection table S 200 M-B ................................................................................... 41 Selection table S 200 M-C ................................................................................... 43 Supplementary devices .......................................................................................... 44 Selection table F 200 ........................................................................................... 45 Selection table busbars, rail connectors ............................................................. 47 Selection table accessories ................................................................................. 49 3 Outstanding features Applications System pro M compact (R) SK 0048 B 99 SK 0049 B 99 All round protection against contact with live parts in acordance with DIN VDE 106 part 100. B A Due to new design: Upper and lower shoulders reduced. More working space between component rows. Outgoing and incoming connection points easily accessible. New, failsafe, bi-directional cylinder lift terminal, ensuring a faster, totally error-free connection. As you tighten the screw, the terminal draws together to simultaneously close the front and rear wiring inputs. This creates a strong, contactassured connection between the wires and the device, in a single operation. Busbar is installed at the back terminals (A). Connection of conductors on the front terminals (B). Result: a clear view on all connection points. Never fumble for the right connection point again. Substantially improved cross-wiring safety. Tangible time-savings. SK 0053 B 99 Connection possible for single, multi and finely stranded conductors of 0.75 to 25 mm2. It is also possible to connect conductors with different cross section at the same time. SK 0052 B 99 SK 0051 B 99 4 New cross wiring busbars. Standard length sizes or meter length cutable. Outstanding features Applications SK 0050 B 99 System pro M compact (R) New quick-fastening technique for easy disconnection of the device from the assembly. No time-consuming extra work: Cross-wiring remains with the assembly. To remove the device, just loosen the screw, lift the device and pull it out. If neccessary, all devices of the series connected to the new pro M compact cross-wiring rails may be exchanged easily and quickly, e.g. to implement the adaptation to the VDE standard 0100 part 410. Easy to add on MCB for extensions. SK 0047 B 99 SK 010 B 01 New, integrated auxiliary contact, factory fitted, reduces space by 50 %. Cross wiring to customary compact busbar possible. Self-adhesive identification labels are provided for all devices, ensuring clear and accurate identification. Every detail of System pro M compact has now been optimised to meet the user's requirements. Fuirthermore, System pro M compact offers you many different ways to label the switchgear cabinet and built-in consumer unit in a professional manner. Individual, effecient labeling of devices. Pad lock prevents unauthorized switching to ON or OFF. Complete range of tripping characteristics in B, C, D, K, Z. SK 0045 B 99 High rated switching capacity of 6 000 A (S 200) or 10 000 A (S 200 M). Current limitation is below the values prescribed by the VDE, therefore higher selectivity rating than energy limitation class 3. Disconnector abilities according to DIN VDE 0660 part 107, surge withstand capability 6 kV (1.2/50). 5 System pro M compact (R) Miniature circuit-breakers The offer at a glance Oscillogram of rupturing process Description Trip charcteristics The MCBs of the S 200/S 200 M series have a current-limiting effect. They have two different trip releases acting on the contact mechanism B They offer: high short-circuit capacity high selectivity for back-up fuse In case of short-circuit, low stress on the cable in the point of fault due to the high limitation of the let-through i2dt (current heating value). Task C SK 0128 Z 00 To protect against excessive temperature rises of electric items in the case of overcurrents caused by overload, short circuit of earth-fault current if assigned according to DIN VDE 0100 Part 430. Protection against electric shock in the case of excessive touch voltage caused by insulation fault if assigned according to DIN VDE 0100 Part 410. SK 0130 Z 98 SK 0126 Z 00 1. the delayed thermal release providing overload protection 2. the electromagnetic instantaneous release with "hammer trip" solenoid providing fault current protection. IK * 2 = peak value of prospective short circuit current iD = max. let-through current of device S 200/S 200 M Un = system voltage UB = arc voltage of MCB tK = breaking time of MCB Trip charcteristics and rated current Independent of the type of characteristic, national codes of practice provide what highest rated current and/or performance characteristic can be assigned to the conductor cross section to be protected (e.g. DIN VDE 0100 Part 430). The following assignment rules apply: Ib In Iz; I2 1,45 * Iz Ib = operating current of the circuit to be expected In = rated current of the MCB of characteristics type B, C, D, K and Z Iz = permissible current loading of lines I2 = conventional tripping current K SK 0142 Z 00 B-, C- and D-type trip characteristics for line protection Tripping behaviour according to DIN VDE 0641 Part 11. Rated current 6 ... 63 A, (C 0,5 ... 63 A). The introduction of these trip characteristics enables direct assignments of MCBs to the permissible load of lines I z according to DIN VDE 0298 Part 4/11.98, as the second condition is already fulfilled (I2 = 1.45 * In). K-type trip characteristics Tripping behaviour according to DIN VDE 0660 Part 101 and IEC 947-2, rated current 0.5 ... 63 A, for circuits where current-consuming appartus cause functional current peaks and for the overcurrent protection of lines. Z 6 SK 0146 Z 00 Z-type trip characteristics Tripping behaviour according to DIN VDE 0660 Part 101 and IEC 947-2 Rated current 0.5 ... 63 A in 17 grades. For the protection of semiconductors and measuring circuits with transformers. System pro M compact (R) Miniature circuit-breakers S 200/S 200 M series Technical data Specifications: DIN VDE 0641 Part 11, IEC 60898, EN 60898, IEC 60947-2, UL 1077 No. of poles: 1, 2, 3, 4, 1 + NA, 3 + NA tripping charcteristics: B, C, D, K, Z rated current In: B 6 ... 63 A , C, D, K and Z 0,5 ... 63 A rated voltage Un: 1-pole multipole max. operating voltage UBmax: AC Un + 10 % DC 1-pole 2-pole min. operating voltage UBmin : 12 V~, 12 V- energy limitation class: S3 short circuit rupturing capacity: see page 9 frequency: 50 ...60 Hz insulation coordination: - overvoltage category: according to DIN VDE 0110 Part 1 and 2 2 - surge voltage: 5 kV (1.2/50 s) - impulse alternating voltage: 60 V ... 125 V ... III - pollution degree: housing: 7035 230 V 400 V 3 kV (50/60 Hz) Insulating material rating I (CTI 600) according to DIN IEC 112/VDE 0303 Part 1, RAL operating lever: Insulating material rating II (400 CTI 600) black, sealable degree of protection acc. to DIN VDE 0100: IP 20, in the consumer unit IP 40 dimensions: according to DIN 43880, size code 1 depth of device: 68 mm overall dimensions: see page 25 mounting position: optional fixing: snap-on to DIN rails EN 60 715, 35 mm or screw fixing by means of mounting plate (see accessories) connection: to failsave bi-directional cylinder-lift terminal at top and bottom, shock-protected according DIN VDE 0106 Part 100. Suitable for connection of single, multi or finely stranded conductors up to 25 mm2 (if also connected to rails) tightening torque: 2.8 Nm mechanical service life: 20,000 operations service life at rated load In 32 A: In 32 A: 20,000 operations 10,000 operations climatic resistance acc. to DIN IEC 68 Part 2-30: constant climate 23/83, 40/93, 55/20 [C/RH] alternating climate 25/95 - 40/93 [C/RH] storage temperature: T max +70 C/158 F, Tmin -40 C/-13 F ambient temperature: T max +55 C/158 F, Tmin -25 C/-13 F shock resistance: 30 g, at least 2 impacts shock duration 13 ms resistance to vibration acc. to DIN IEC 68-2-6: 5 g, 20 frequency cycles 5 ... 150 ... 5 Hz at 0.8 In weight: see selection tables Technical data of the integrated auxiliary contact contact: 1NO (1 make contact) 1NC (1 normally closed contact) contact load: AC 14 230 V 2 A DC 12 identical DC 13 DC 13 50 V 1 A min. operating voltage: 12 VAC/DC at 0.1 VA short-circuit withstand capacity: 230 V 1,000 A electrical service life: 4,000 operations safe disconnection of auxiliary circuit and main circuit according to VDE 0106 Part 101 connection capacity: 0.75 to 2.5 mm2 (finely-stranded conductors to be fitted with a connector sleeve) 7 Miniature circuit-breakers S 200/S 200 M series System pro M compact (R) Internal resistance and power loss of the miniature circuit-breakers Internal resistance per pole in m, power loss per pole in W type rated current In A S 200 and S 200 M 0.5 1 1.6 2 3 4 device series B, C, D m W K m W Z m W 5500 1440 630 1.4 1.4 1.6 6340 1550 695 1.6 1.6 1.8 10100 2270 1100 2.5 2.3 2.8 460 150 110 1.8 1.3 1.8 460 165 120 1.9 1.5 2.0 619 202 149 2.5 1.8 2.4 104 53.9 17.5 3.7 3.45 1.7 10.9 6.0 - 2.8 2.4 6 8 10 55 15 13.3 2.0 1.0 1.3 52 38 12.6 1.9 2.5 1.26 13 16 20 13.3 7.0 6.25 2.3 1.8 2.5 12.6 7.7 6.7 1. 26 2.0 2.7 25 32 40 5.0 3.6 3.0 3.2 3.7 4.8 4.6 3.5 2.8 2.9 3.6 4.5 4.1 2.8 2.5 2.6 2.9 4.1 50 63 1.3 1.2 3.25 4.8 1.25 0.7 2.9 5.2 1.8 1.3 4.4 5.2 - Current intensities 0.5 - 4 apply exclusively to C-type trip characteristics. Maximum permissible fault loop impedance ZS at U0 = 230 V to ensure compliance with the rupturing conditions prescribed in DIN VDE 0100 Part 410. The internal resistance of MCB is included. Note: Attention should be paid to the maximum voltage drop S 200 and S 200 M B C D K Z max. ZS max. ZS max. ZS max. ZS max. ZS 0,5 46.0 33.0 38.3 153.3 1 23.0 16.5 19.2 76.7 1.6 14.4 10.3 12.0 47.9 2 11.5 8.2 9.6 38.3 3 7.7 5.5 6.4 25.6 4 5.8 4.1 4.8 19.2 7.7 3.8 2.7 3.2 12.8 Bemessungsstrom In A 6 8 - 2.8 2.1 2.4 9.5 10 4.6 2.3 1.6 1.9 7.7 13 3.5 1.7 1.2 - - 16 2.9 1.4 1.0 1.2 4.8 20 2.3 1.2 0.8 1.0 3.8 25 1.8 0.9 0.7 0.8 3.1 32 1.4 0.7 0.5 0.6 2.4 40 1.2 0.6 0.4 0.5 1.9 50 0.9 0.5 0.3 0.4 1.5 63 0.7 0.4 0.3 0.3 1.2 U0 = rated voltage against earthed conductor; for U0 = 240 V : ZS * 1.04; for U0 = 127 V ZS * 0.55 The max. permissible lenght of cable at different voltage and cross sections on request. 8 Miniature circuit-breakers S 200/S 200 M series System pro M compact (R) Tripping characteristics acc. to tripping characteristic and rated current thermal release current: conventional conventional non-triping c. tripping c. DIN VDE 0641/T 11 B 6 to 63 A 1.13 * In C 0.5 to 63 A D 0.5 to 63 A K 0.5 to 63 A DIN VDE 0660/9.82 Z DIN VDE 0660/9.82 0.5 to 63 A DIN VDE 0660 8/69 Part 1 >1h <1h 3 * In >1h <1h 5 * In 1.45 * In >1h <1h 10 * In 1.45 * In 1.2 * In >1h <1h 1.2 * In 1.5 * In 6.0 * In >2h <2h < 2 min. > 2 s (T1) 1.2 * In >1h <1h 1.2 * In 1.5 * In 6.0 * In >2h <2h < 2 min. > 2 s (T1) 1.13 * In 1.13 * In 1.05 * In 1.05 * In 1.05 * In factor ca. 200 Hz 400 Hz 1.1 1.2 1.5 1.5 A S 200-B S 200 M-B S 200-C S 200 M-C S 200-D S 200-K S 200-Z 6 10 ... 20 25 ... 32 40 50 ... 63 0.5 ... 2 3 ... 4 6 8 10 ... 20 25 ... 32 40 50 ... 63 0.5 ... 2 3 4 6 ... 10 16 ... 20 25 ... 32 40 50 ... 63 0.5 ... 2 3 ... 4 6 8 10 ... 16 20 ... 25 32 ... 40 50 ... 63 alternating current 2/3phase 230 V 230 V kA/cos 10/0.5 kA/cos 6/0.7 400 V 133/230 V kA/cos 10/0.5 6/0.7 12 * In > 0.2 s < 0.2 s 3 * In > 0.2 s < 0.2 s 2 * In 1pole 60 V ... 230/400 V kA/cos 6/0.7 direct current Max. back-up kA/T ms fuse gL 10/4.0 10/0.5 6/0.7 10/4.0 10/0.5 (S 200 M-C) 10/0.5 6/0.7 10/4.0 6/0.7 10/4.0 unlimited 10/0.5 > 0.1 s < 0.1 s not applicable unlimited 6/0.7 20 * In 8 * In 10/0.5 (S 200 M-B) 10/0.5 ( S 200 M-C) 10/0.5 > 0.1 s < 0.1 s not applicable unlimited 6/0.7 10 * In operating sequence: B and C according to DIN VDE 0641, DIN VDE 0660 Part 101 ICS K and Z according to IEC 947 10/0.5 (S 200 M-B) 10/0.5 > 0.1 s < 0.1 s The standard DIN VDE 0660/9.69 has expired in 1986, but is still referred to due to its complete statement of the tripping characteristics. The thermal release operates independently of voltagest. series trip characteristic 1phase rated current 133 V 5 * In as from operating temperature (after I1 > 1 h or, as applicable, 2 h). direct current Short circuit rupturing capacity and back-up tripping time The thermal releases are calibrated to a nominal reference ambient temperature; for Z and K, the value is 20 C, for B and C = 30 C. In the case of higher ambient temperatures, the current values fall by ca. 6% for each 10 K temperature rise. The indicated tripping values of electromagnetic tripping devices apply to a frequency range of 16 2/3 ... 60 Hz. In the case of diverging frequencies or direct current, the values change by the factor indicated below alternating current 100 Hz electromagnetic release currents: hold trip current surges at least at 1.45 * In 1.05 * In DIN VDE 0660 8/69 Part 1 tripping time 10/0.5 main circuit-br. S 700 63 A 100 A 100 A 100 A 100 A 100 A 125 A 100 A 160 A 100 A not required 20 A - 40 A 100 A 63 A 100 A 100 A 100 A 100 A 100 A 125 A 100 A 160 A 100 A not required 20 A - 25 A - 63 A 100 A 80 A 100 A 100 A 100 A 125 A 100 A 160 A 100 A not required 20 A - 35 A 100 A 40 A 100 A 63 A 100 A 80 A 100 A 100 A 100 A 125 A 100 A In symmetrically earthed direct current circuits, 2-pole devices (two poles connected in series) can be used up to 110 VDC. Any connection is possible, polarity does not need to be taken into account. Back-up protection is necessary only if the solid short-circuit current to be expected at the place of installation may exceed the switching capacity indicated. 9 Miniature circuit-breakers S 200/S 200 M series System pro M compact (R) Short circuit selectivity: In the case of a short circuit, selectivity exists up to the values indicated. MCBs short circuit discrimination in kA SK 0112 Z 99 SK 0113 Z 99 to fuse gL/gG to main circuit breaker S 700 (DIN VDE 0636; IEC 269/3) series S 200-B, C, D Current values smaller than 6 A and 8 A, apply only to C and D characteristics. In A 16 2 15 20 25 35 40 25 35 50 63 80 15 15 15 15 100 125 160 15 15 15 1 1.2 4 10 10 10 10 8 8 0.3 0.7 1.2 4.6 6 6 6 6 6 4 10 10 10 10 10 10 10 8 8 0.3 0.6 0.9 2.8 6 6 6 6 6 6 6 10 10 10 10 10 10 10 8 8 0.2 0.5 0.8 2 3.3 5.5 6 6 6 6 8 10 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.7 2.8 4.5 6 6 6 6 10 10 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.5 2.5 3.5 5 6 6 6 0.7 1.5 2.5 3.5 5 6 6 6 1.3 2 2.9 4.1 6 6 6 10 10 10 10 10 10 10 8 8 16 10 10 10 10 10 10 10 8 8 10 10 10 10 10 10 8 8 1.8 2.6 3.5 5 6 6 10 10 10 10 10 8 8 1.8 2.6 3.5 5 6 6 6 10 ** 2 15 10 10 10 8 8 2.2 3 4 6 10 10 10 8 8 2.5 4 6 6 6 10 10 8 8 3,5 5 6 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 1 1.2 4 3 15 15 15 15 15 15 15 10 10 0.3 0.7 1.2 4.6 6 6 6 6 6 4 15 15 15 15 15 15 15 10 10 0.3 0.6 0.9 2.8 6 6 6 6 6 6 6 15 15 15 15 15 15 15 10 10 0.2 0.5 0.8 2 3.3 5.5 6 6 6 6 8 15 15 15 15 15 15 15 10 10 0.2 0.4 0.7 1.7 2.8 4.5 6 6 6 6 10 15 15 15 15 15 15 15 10 10 0.2 0.4 0.7 1.5 2.5 3.5 5 6 6 6 0.7 1.5 2.5 3.5 5 6 6 6 1.3 2 2.9 4.1 6 6 6 6 13 15 15 15 15 15 15 15 10 10 16 15 15 15 15 15 15 15 10 10 15 15 15 15 15 15 10 10 1.8 2.6 3.5 5 6 6 15 15 15 15 15 10 10 1.8 2.6 3.5 5 6 6 3 4 6 6 2.5 4 6 6 3.5 5 6 25 32 15 40 ** 15 15 15 10 10 15 15 15 10 10 15 15 10 10 50/63 2 15 15 15 15 15 15 15 15 15 2.2 15 15 15 15 15 15 15 0.3 1.2 4 3 10 10 10 10 10 10 10 10 10 0.3 0.7 1.2 4.6 6 6 6 6 6 6 4 10 10 10 10 10 10 10 10 10 0.3 0.6 0.9 2.8 6 6 6 6 6 6 6 10 10 10 10 10 10 10 10 10 0.7 1.7 3 5.9 6 6 6 6 8 10 10 10 10 10 10 10 10 10 1.3 2.2 3.6 6 6 6 6 10 10 10 10 10 10 10 10 10 10 1.7 2.5 4 6 6 6 16 10 2.2 20 10 10 10 10 10 10 10 10 3.1 4.6 6 6 10 10 10 10 10 10 10 10 3.1 4.6 6 6 10 10 10 15 10 10 10 2.6 3.5 6 6 10 10 10 10 10 10 3.5 6 6 10 10 10 10 10 10 10 10 10 25 32 40 ** 50/63 2 15 15 15 15 15 15 15 15 15 5.5 6 6 15 15 15 15 15 15 15 15 0.5 2 3 10 10 10 10 10 10 10 10 10 0.3 0.7 1.2 6 6 6 6 6 6 4 10 10 10 10 10 10 10 10 10 0.3 0.6 1.3 7 6 6 6 6 6 6 6 10 10 10 10 10 10 10 10 10 0.2 0.5 0.9 2.7 6 6 6 6 6 6 0.2 0.5 0.6 1.7 3.8 6 6 6 6 6 0.4 0.6 1.3 2.4 4 6 6 6 6 0.5 1.1 1.7 3 4.5 6 6 6 0.9 1.5 2.3 3.5 5.2 6 6 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 20 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 25 10 32 40 50/63 ** 6 10 10 15 10 10 10 1.4 2 3 4 6 6 10 10 10 10 10 10 1.4 2 3 4 6 6 10 10 10 10 10 10 10 10 10 2 3 4 6 6 2.2 3.5 5.8 6 ** Limited or no selectivity at all possible in the overload range (thermal tripping) 10 6 13 20 Selectivity values apply to Icu according to IEC 947-2. 20 10 50/63 S 200 Z 16 10 40 Selectivity values apply to Icu according to IEC 947-2. 100 15 15 15 15 15 15 15 15 32 S 200-K 80 10 25 Current values smaller than 6 A and 8 A, apply only to C characteristics. 63 3 20 S 200 M-B, C 50 The above values require that, in the case of multi-phase installations, that the last cb be feed from above. System pro M compact (R) Miniature circuit-breakers S 200/S 200 M series Tripping diagrams Reading example for tripping characteristic of the B-type trip characteristics (in connection with the table tripping characteristics on page 9, line B) a Thermal tripping characteristic: SK 0038 Z 01 Electromagnetic trip characteristic AC: The MCB maintains current rushes of the 3-fold of the rated current for more than 0.1 sec. (in this example up to ca. 4 sec.). The MCB switches off within less than 0.1 sec when the 5-times of the rated current is reached. trip characteristic: D In = 0.5 ... 63 A S 200 MCBs trip characteristic: C In = 0.5 ... 63 A S 200/S 200 M MCBs Deviating ambient temperature values and interdependencies need to be taken into account SK 0142 Z 00 trip characteristic: K In = 0.5 ... 63 A S 200 MCBs SK 0146 Z 00 Note: trip characteristic: B In = 6 ... 63 A S 200/S 200 M MCBs 2CDC 022 377 F0203 b SK 0128 Z 00 Conventional non-tripping current I1 = selected non-tripping current The MCB maintains the 1.13 times of the rated current for at least 60 minutes. Conventional tripping current I2 = selected tripping current. The MCB switches off within 60 minutes when the 1.45 times of the rated current is reached. trip characteristic: Z In = 0.5 ... 63 A S 200 MCBs 11 System pro M compact (R) Miniature circuit-breakers S 200/S 200 M series 2CDC 022 131 F0203 Pulse tripping of the MCBs S 200/S 200 M made by ABB-STOTZ-KONTAKT Example: S 201-B16 non-tripping current (electromagnetic release) Ihold = K x non-tripping current Ihold = 4.2 x 3 x 16 Ihold = 201.6 A B-type characteristic = 3 x In C-type characteristic = 5 x In D-type characteristic = 10 x In K-type characteristic = 10 x In Z-type characteristic = 2 x In In the case of an impulse of 600 , S 201-B16 maintains up to a current of 201.6 A. 12 System pro M compact (R) Miniature circuit-breakers S 200/S 200 M series Diagrams of let-through values I2 t at 230/400 VAC Miniature circuit-breakers S 200 K 2CDC 022 132 F0203 2CDC 022 157 F0203 Miniature circuit-breakers S 200 B/C, D on request min. pre-arcing I2t, e.g. In = 80 A gL max. let-through I2t MCB e.g. B20 A Fuse-MCB, selectivity with respect to the upstream fuse to the point of intersection of both curves e.g. S 200-B20 to fuse 80 A: selectivity up to 3.5 kA min. Let-through value I 2 t reduced: 127 V by factor 2.5 110 V by factor 3 and . Miniature circuit-breakers S 200 M B/C 2CDC 022 159 F0203 Miniature circuit-breakers S 200 Z 2CDC 022 152 F0203 13 Miniature circuit-breakers S 200/S 200 M series System pro M compact (R) The influence of ambient temperature and interdependencies in the case of even loads on the load capability of MCBs Practical Note: This practical deduction, that is applicable for all types of characteristics, can be recommended for standard environments. Selection criteria for rated current of circuit-breakers according to EN 60898 and EN 60947-2. Choose the circuit-breaker that is appropriate for the lower of the rated value of the device or the permissible current loading. Now, the major factors having an influence on the circuit-breaker, must be taken into account: 1. ambient temperature with IB 0.9 x In at 40 C ambient temperature 2. mutual influence with IB 0.75 x In in the case of more than one circuit-breaker being loaded evenly in parallel. The ensuing rated current of the circuit breaker is thus: In = 1.5 x rated current Example: operating currect 4 A, then the rated current of the circuit-breaker is: In = 1.5 x 4 A = 6 A The above takes into account all relevant factors and the circuit is protected at the lowest possible level. This practical note is based on the following: 1. Deviating ambient temperature: The thermal releases are adapted to a given reference ambient temperature. For the K- and Z-type characteristics, it is 20 C, for B-, C- and D-type, it is 30 C. For all other ambient temperatures, the current values indicated vary by ca. 6 % per 10 K temperature de/increase. For more precise calculations and very high/low ambient temperatures, the following tables apply: Max. operating current depending on the ambient temperature circuit-breaker in load circuit of characteristics type B, C and D Ambient temperature T (C) B, C and D In (A) - 40 - 30 - 20 - 10 0 10 20 30 40 50 60 70 0.5 1.0 0.67 1.33 0.65 1.29 0.62 1.25 0.60 1.20 0.58 1.15 0.55 1.11 0.53 1.05 0.50 1.00 0.47 0.94 0.44 0.88 0.41 0.82 0.37 0.75 1,6 2,0 2.13 2.67 2.07 2.58 2.00 2.49 1.92 2.40 1,85 2.31 1.77 2.21 1.69 2.11 1.60 2.00 1.51 1.89 1.41 1.76 1.31 1.63 1.19 1.49 3,0 4,0 4.0 5.3 3.9 5.2 3.7 5.0 3.6 4.8 3.5 4.6 3.3 4.4 3.2 4.2 3.0 4.0 2.8 3.8 2.6 3.5 2.4 3.3 2.2 3.0 6,0 8,0 8.0 10.7 7.7 10.3 7.5 10.0 7.2 9.6 6.9 9.2 6.6 8.8 6.3 8.4 6.0 8.0 5.7 7.5 5.3 7.1 4.9 6.5 4.5 6.0 10,0 13,0 13.3 17.3 12.9 16.8 12.5 16.2 12.0 15.6 11.5 15.0 11.1 14.4 10.5 13.7 10.0 13.0 9.4 12.3 8.8 11.5 8.2 10.6 7.5 9.7 16,0 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1 11.9 20,0 25,0 26.7 33.3 25.8 32.3 24.9 31.2 24.0 30.0 23.1 28.9 22.1 27.6 21.1 26.4 20.0 25.0 18.9 23.6 17.6 22.0 16.3 20.4 14.9 18.6 32,0 40,0 42.7 53.3 41.3 51.6 39.9 49.9 38.5 48.1 37.0 46.2 35.4 44.2 33.7 42.2 32.0 40.0 30.2 37.7 28.2 35.3 26.1 32.7 23.9 29.8 50,0 66.7 64.5 62.4 60.1 57.7 55.3 52.7 50.0 47.1 44.1 40.8 37.3 63,0 84.0 81.3 78.6 75.7 72.7 69.6 66.4 63.0 59.4 55.6 51.4 47.0 Max. operating current depending on the ambient temperature circuit-breaker in load circuit of characteristics type K and Z Ambient temperature T (C) K and Z 2. Interdependencies in the case of even loads In (A) - 40 - 30 - 20 - 10 0 10 20 30 40 50 60 70 0.5 0.66 0.64 0.61 0.59 0.56 0.53 0.50 0.47 0.43 0.40 0.35 0.31 1.0 1.6 1.32 2.12 1.27 2.04 1.22 1.96 1.17 1.88 1.12 1.79 1.06 1.70 1.00 1.60 0.94 1.50 0.87 1.39 0.79 1.26 0.71 1.13 0.61 0.98 2.0 3.0 2.65 4.0 2.55 3.8 2.45 3.7 2.35 3.5 2.24 3.4 2.12 3.2 2.00 3.0 1.87 2.8 1.73 2.6 1.58 2.4 1.41 2.1 1.22 1.8 4.0 6.0 5.3 7.9 5.1 7.6 4.9 7.3 4.7 7.0 4.5 6.7 4.2 6.4 4.0 6.0 3.7 5.6 3.5 5.2 3.2 4.7 2.8 4.2 2.4 3.7 2 and 3 circuit-breakers with factor 0.9 8.0 10.0 10.8 13.2 10.2 12.7 9.8 12.2 9.4 11.7 8.9 11.2 8.5 10.6 8.0 10.0 7.5 9.4 6.9 8.7 6.3 7.9 5.7 7.1 4.9 6.1 4 and 5 circuit-breakers with factor 0.8 13.0 16.0 17.2 21.2 16.6 20.4 15.9 19.6 15.2 18.8 14.5 17.9 13.8 17.0 13.0 16.0 12.2 15.0 11.3 13.9 10.3 12.6 9.2 11.3 8.0 9.8 6 and more circuit-breakers with factor 0.75 20.0 25.0 26.5 33.1 25.5 31.9 24.5 30.6 23.5 29.3 22.4 28.0 21.2 26.5 20.0 25.0 18.7 23.4 17.3 21.7 15.8 19.8 14.1 17.7 12.2 15.3 32.0 42.3 40.8 39.2 37.5 35.8 33.9 32.0 29.9 27.7 25.3 22.6 19.6 40.0 50.0 52.9 66.1 51.0 63.7 49.0 61.2 46.9 58.6 44.7 55.9 42.4 53.0 40.0 50.0 37.4 46.8 34.6 43.3 31.6 39.5 28.3 35.4 24.5 30.6 63.0 83.3 80.3 77.2 73.9 70.4 66.8 63.0 58.9 54.6 49.8 44.5 38.6 The interdependency becomes irrelevant if FST ... spacers or packing blocks (9mm width) are used. 14 A correction factor must be taken into account in the case butt-mounted devices and an evenly applied, high load: Miniature circuit-breakers S 200/S 200 M series System pro M compact (R) Use of S 200/S 200 M miniature circuit-breakers in direct current circuits 60 VDC/125 VDC In DC systems up to 60 VDC or, as the case may be, series connection up to 125 VDC, customary S 200/S 200 M series MCBs can be used. Polarity does not need to be taken into consideration, the outgoing circuit may be implemented from above or below the device. For higher direct voltage up to 440 VDC devices of the S 280 UC series must be used. SK 0173 Z 99 Example for max. permissible voltages between conductors depending on the number of poles and type of connection. SK 0174 Z 99 Examples for different voltages between a conductor and earth where voltages between conductors are identical: Fusing of lighting currents 1. Filament lamps and fluorescent lamps The following table indicates the maximum number of fluorescent lamps that can be protected with a single-pole miniature circuit-breaker. In the case of multipole MCBs, the value is reduced by 20 %. Tripping charcteristic type C allows for light currents up to the rated current of the MCB, for fusing of: filament lamps fluorescent lamps a) non-compensated b) shunt compensated (cos = 0.95) c) electronic load Characteristic/ rated current non-compensated conventional ballast shunt compensated conventional ballast electronic ballast 18/20 W 36/40 W 58/65 W 18/20 W 36/40 W 58/65 W 18/20 W 36/40 W 58/65 W 10 27 23 15 32 32 20 18 18 8 16 43 37 24 51 51 33 26 26 12 20 53 46 30 64 64 41 33 33 15 25 66 58 37 82 82 53 42 42 19 electronic ballast: twin-lamp style, jointly switched number of lamps 2. High-pressure discharge lamps Starting current: ca. 1.7 x lamp current Recovery time: ca. 3 ... 5 min. According to the type of lamp, line impedance and start-stop torque, the so-called rectifier effect may occur which superimposes the starting current of the lamp for some half-waves. In the most unfavorable circumstances, inrush currents of 15 times of the lamp nominal current may ensue. To avoid nuisance tripping, MCBs with K-type characteristic should not carry loads higher than 0.6-fold of the lamp current. The load factor indicated refers to the least favorable case (proximity to transformer, low line impedances). 15 System pro M compact (R) Miniature circuit-breakers S 200/S 200 M series Installation and operation instructions Installation Can be installed in any mounting position due to snap-on fixing to DIN rails EN 60 715, 35 mm width. A If MCB S 200/S 200 M is installed without cross wiring, hinge the upper part into the DIN rail and push to let the lower part of the device snap into place (1). The device is released in the reverse order, after the quick fastener has been removed with a screw driver (2). B To release S 200 /S 200 M that are cross-wired with System pro M compact busbars, first remove the clamping screws Then, pull the lower part of the S 200/S 200 M forwards (1) and lift it straight up (1a) , then, the quick fastener (1b) will recede. C The busbar is deallocated and the S 200/S 200 M can be pulled out by lifting the device forwards (2). D The cross-wiring is re-inserted in the reverse order. First, open the clamping screws and pull out the quick fastener until it locks into place for the first time (3) . Then, take the S 200 /S 200 M and insert it with rear terminal side onto the pins of the System pro M compact busbar (4) , turn it into the direction of the DIN rail (4a) and shift it vertically downwards (4b) ,this way, the quick fasterner snaps back into place (4c). Attention: Do not forget to re-tighten the clamping screws. snap on release pro M compact busbar SK 0269 Z 98 pro M compact busbar SK 0268 Z 98 pin SK 0167 Z 99 D Insertion when pro M compact cross wiring remains in place C Removal when pro M compact cross wiring remains in place quick fastener B Detaching when pro M compact cross wiring remains in place SK 0267 Z 98 SK 0266 Z 98 A Assembly, disassembly without pro M compact cross wiring pin pro M compact busbar Operation MCBs are switched on by switching the operating lever into the upper position (with resepct to the text block of the nameplate). If an MCB, after it has triggered, cannot be switched on again off-handedly, the triggering is probably caused by overload. If the MCB trips again immediately when trying to reclose (let a short period of time elapse), a complete short-circuit, or as the case may be, earth connection can be assumed. Do not try and continuously re-close an existing short circuit or earth fault. The MCB even trips under overload, or short-circuit or earth fault conditions, even if the operating lever is maintained in the ON position by force (trip-free mechanism). Cleaning the device MCBs soiled by installation work should be cleaned with a dry, or, if necessary, a damp and soapy cloth. Never use caustic agents or dissolvents. Maintenance STOTZ MCBs are maintenance-free. Connection: For connection cross sections, see page 7. Feeder optional, top or bottom, terminal designation according to EN 50 005. For wiring diagrams, see picture to the right. 16 2CDC 022 153 F0003 Opening the device will lead to a loss of warranty. System pro M compact (R) Supplementary devices Additional devices Mounting additional devices Additional devices are always fitted from the right hand side: - signal contact/auxiliary switch S2C-S/H6R for MCBs and RCCBS - auxiliary switch S2C-H6R for MCBs - shunt release S2C-A for MCB only to MCBs to shunt releases 2CDC 092 154 F0003 to MCBs and RCCBs S function signal contact H function auxiliary switch 1. Signal contact and auxiliary switches Retrofittable to the right side of circuit-breakers or shunt releases without extra installation devices. 1.1 Universal signal contact/ auxiliary switch type S2C-S/H6R Description S2 - serial code: S 2 C - S/H 6 R R = right side-mounted 6 = change over H = auxiliary switch S = signal contact C = compatible to pro M compact S2C-S/H6R is a universal device complementing the range of pro M compact, which is supplied to offer signal contact functionality, or the auxiliary switch can be activated, all you need is a screwdriver. The universal switch can be with MCBs and RCCBs. Up to three S2C-H6R can be mounted (one signal contact max. fitted to MCB or RCCB). Both the switchgear and the S2C-S/H6R must be in the ON end position to ensure that the coupling is correct. Function of the signal contact S Signal is transmitted only if caused by fault-tripping of the circuit-breaker, but not if the switch has been switched on or off manually. Press the orange reset button to acknowledge the has-tripped signal. Function of the auxiliary switch H The switch always indicates the switching position of the MCB, irrespective of whether the switching position is attributable to manual operation or fault tripping. SK 0170 Z 02 Functionality selection To select either the signal contact function S or the auxiliary switch H, use a screwdriver and adjust to position S, or as the case may be, H at the side of the device. 17 System pro M compact (R) Supplementary devices Installation: 1. Mounting one S2C-S/H6R RCCB or MCB must be in the ON position remove coupling cover on the right side of the MCB/RCCB signal contact/auxiliary switch in ON position if fitted to MCB, remove bottom (RCD), if fitted to RCCB middle (MCB) coupling pin plug devices together. SK 0287 Z 02 SK 0288 Z 02 2. Mounting more than one S2C-S/H6R Up to three S2C-H6R can be mounted. Note: one signal contact max. fitted at first to MCB or RCCB If fitted to an MCB, remove the bottom coupling pin (RCD), if fitted to an RCCB, remove the middle coupling pin (MCB), switch all signal contact/ auxiliary switches to the end position ON, plug them together and carry through a function control test. SK 0285 Z 02 Function control test: After all signal contacts/auxiliary switches or auxiliary switches have been mounted, use the upper coupling pin to switch on the devices (ON position). If the lower (for RCD) or, as the case may be, the middle (for MCB) coupling pin is operated, all devices must trip. Now combination with MCB/RCCB: RCCB or MCB must be in the ON position remove coupling cover on the right side of the MCB/RCCB signal contact/auxiliary switch in ON position if fitted to MCB, remove bottom (RCD), if fitted to RCCB middle (MCB) coupling pin plug devices together. in ON and OFF position after hand operation in ON position 18 SK 0243 Z 02 in OFF position SK 0242 Z 02 in ON position after tripping SK 0241 Z 02 Test functions of the auxiliary switch SK 0240 Z 02 Test functions of the signal contact Supplementary devices System pro M compact (R) Technical Data Signal contact/auxiliary switch S2C-S/H6R and auxiliary switch S2C - H6R according to EN 62019 AC 14 Ue 400 V 230 V Ie DC 12 DC 13 1A Ue 2A 220 V 110 V Ie 1A 1.5 A Ue 60 V Ue 1.5 A rated current Ith: 10 A min. rated voltage UBmin: 24 V ~, 24 V ... min. rated operational current: 5 VA short-circuit withstand capacity: 230 V~ 1000 A with S 201 K 4 insulation coordination: according to DIN VDE 0110 Parts 1 and 2 - overvoltage category: III 24 V - surge voltage: 4 kV (1.2/50 s) 4A - pollution degree: 2 connection cross section: 0.75 ... 2.5 mm2 (up to 2 x 1.5 mm2) tightening torque: 1.2 Nm max. contact stability in vibration test according to DIN IEC 68-2-6-: mech. service life: 5 g, 20 sweep cycles 5 ... 150 ... 5 Hz at 24 VAC/DC, 5 mA automatic reclosing < 10 ms 10 000 operations The minimum rated operational current value applies in the case of operation and environmental conditions according to EN 60 204-1/1998 and EN 60 439-1/2000 if installed indoors and in clean ambient air: 24 VAC/DC, 5 mA (AC-12, DC-12) 1.2 Auxiliary switch type S2C-H6R Description The simple auxiliary switch without test functionality is appropriate for applications where it is only necessary to indicate the contact position of the circuit-breaker. Up to three S2C-H6R can be butt-mounted, including combinations with the signal contact/auxiliary switch SC2-S/H6R. Installation and technical data the same as for signal contact/auxiliary switch SC2-S/H6R, see preceding page and above. Installation and technical data the same as for signal contact/auxiliary switch SC2-S/H6R, see preceding page and above. 2. Shunt trip S2C-A Description For distance tripping of the MCB. The shunt release has a relay coil with an integrated contact which disconnects the coil and the coil voltage if the MCB trips, this prevents the flow of current in the case of sustained coil voltage. Technical data type: S2C - A1 S2C - A2 service voltage: 12 ... 60 V 110 ... 415 VAC and 110 ... 250 VDC STOTZ-Shunt trip with automatic disconnecting within 10 milliseconds UB = Un + 10 - 30 % S2C-A1 UB IBmax 12 VDC 2.2 A 12 VAC 2.5 A 24 VDC 4.5 A 220 VDC 1.1 A 24 VAC 5A 230 VAC 1.0 A 60 VDC 14 A 415 VAC 2.7 A 60 VAC 8.8 A UB = operating voltage UB S2C-A2 IBmax 110 VDC 0.35 A 110 VAC 0.5 A IBmax = operating current 19 Residual-current-operated circuit breaker F 200 series System pro M compact (R) Description Residual-current protective devices have a balance or, as the case may be, differential current transformer as measuring device that is connected with permanent magnet trip via the secondary winding. Residual-current protective devices cover a.c. fault current and pulsating d.c. fault current and are insensitive to current rushes up to 250 A, selective and short-time delayed tripping types up to 3,000 A). Pulse shape 8/20 according to DIN VDE 0432 Part 2. STOTZ residual-current protective devices are surge-proof and thus insensitive to transient leakage current to earth, as may occur e.g. when switching fluorescent lamps, X-ray apparatus, IT systems and also thyristor control. (The value of the surge strength is indicated in the technical data information regarding the switching variants). Protection through RCD of types AC, A and B according to IEC 755 correct functioning of RCD form of residual current sinusoidal a.c. suddenly applied pulsating d.c. slowly rising suddenly applied with/without superimosed smooth slowly rising d.c. of 6 mA a.c.- sensitive type AC pulsating current-sensitive type A d.c.-sensitive type B F 200 AC F 200 smooth d.c. Selective RCCB F 200S Is installed centrally and operates on a time-selective basis with respect to more sensitive downstream residual-current devices. The result is a high degree of service security, as in the case of a fault, only the circuit affected will be switched off. Due to their surge strength of up to 5,000 A/3,000 A, nuisance tripping of STOTZ main RCCBs caused by remote strike is ruled out. They are therefore the perfect choice for the connection of freezers and agricultural applications (e.g. fans in intensive livestock husbandry) according to DIN VDE 0100 Part 705. Short-time delayed RCCBs F 200 R are RCCBs with high surge strength needed where apparatus causes high leakage currents when switched on or off (e.g. lighting circuits with ballast, long lines). Application To obtain a better level of security in all wiring systems, as well as in supply areas with respect to which codes of practice recommend or require the use of residual-current protective devices. Tasks Protection against electric shock Measures for the protection against electric shock as provided for in DIN VDE 0100 Part 410. These measures are: Protection from indirect touch - as fault protection through disconnection of circuit in the case of excessive touch voltage caused by short circuit to exposed conductive part. Protection from direct touch - as additional protection through disconnection when conductive parts are touched. Dangerous leakage current is switched off within the shortest possible time if the rated residual current of the circuit-breakers is In 30 mA, in the case of people protector FS 201 In 10 mA. Protection against fire - protection against fire ignited by electricity if the nominal residual current of the circuit-breaker is In 300 mA. 20 System pro M compact (R) Residual-current-operated circuit-breakers F 200 series/FS 201 Technical data F 200 F 200 F 200 R F 204 S short time delayed selective AC specifications: DIN VDE 0664 Part 11, EN 61008-2-1 No. of poles: 2-pole 4-pole 2-pole 4-pole 2-pole 4-pole tripping characteristics: FS 201 RCBO DIN VDE 0664 Part 21 and EN 61009/IEC 61009 4-pole - B and C acc. to DIN VDE 0641 and EN 60898; K acc. to DIN VDE 0660 and EN 60947 rated current In: 16, 25, 40, 63 A 25, 40, 63 A 25, 40, 63 A 40 A, 63 A rated residual current I n: 10, 30, 300 30, 100 30 mA and 500 mA and 300 mA 300 mA 10 mA, 30 mA, 300 mA 300 ms 300 ms 120 ... 300 ms 50 ... 150 ms 40 ms 40 ms 20 ... 40 ms - 300 ms 300 ms 40 ms 40 ms - 150 ... 500 ms 60 ... 200 ms 40 ... 150 ms 40 ... 150 ms 300 ms 300 ms 50 ... 150 ms 300 ms 40 ms - - 6 kA, 0,7 5000 A 250 A tripping range at at tripping time at at at at tripping time 0.50 ... 1.0 * I 0.11 ... 1.4 * I 1 * I n: 2 * I n: 5 * I n: 500 A: at 1 * 1,4 I n: at 5 * 1,4 I n: rated switching capacity: surge strength (impulse waveshape 8/20): 250 A n n 3000 A short-circuit withstand capacity: 10.000 A, in connection with an upstream 10.000 A, in connection fuse gL 100 A or the STOTZ selective with an upstream fuse main circuit-breaker S 700-E 100 A gL 100 A or the selective main circuit-breaker S 700-E 100 A rated voltage Un: 2-pole: 230 V ~ 4-pole: 230/400 V ~ 230/400 V ~ max. operating voltage UBmax: operative range of test equipment UT: housing: operating lever/test button: degree of protection: dimensions: connection cross section: service life: climatic resistance according to DIN IEC 68 Part 2-30: (RH = rel. humidity) 40 ms 2-pole: 230 V ~ Un + 10 % 100 V ~ to 264 V ~ 100 V ~ to 264 V ~ 100 V ~ to 264 V ~ insulation coordination according to DIN VDE 0110 Part 1 and 2 - overvoltage category: - pollution degree: - surge voltage Uimp (1,2/50): - power-frequency withstand voltage (50/60 Hz): frequency: 6 to 32 (40) A III, disconnector abilities 2 4 kV 2.5 kV 50/60 Hz 50/60 Hz moulding grey moulding grey blue black/blue IP 20; in the distribution board IP 40; in moulded-plastic casing IP 55 (see accessories) see dimension drawings 1 to 16 mm2 for finely-stranded to massive conductors for In to 40 A, 1 to 25 mm2 for In 63 A 1 to 16 mm2 > 5.000 switches damp heat: 28 cycl. 55/95 ... 100 (/RH) damp heat, cyclic (55 C/28 cycles) alterning climate: 25/95 - 40/93 (C/RH) constant climate: 23/83, 40/93, 55/95 ... 100 (C/RH) ambient temperature: vibration resistance according to: terminals: Tmax. + 55 C Tmin. - 25 C DIN VDE 0664 Part 1/10.85 and EN 61008 bi-directional cylinder-lift terminal trip-free mechanism: connection: supplementary devices: DIN VDE 0664 Part 2/10.85 and EN 61009 yes individually or collectively via a busbar type S2C-S/HR s. pagee 17 in preparation 21 System pro M compact (R) Residual-current-operated circuit-breakers F 200 series/FS 201 Installation and operation instructions Installation Can be installed in any mounting position due to snap-on fixing to DIN rails EN 50 022, 35 mm width. A If RCD F 200/FS 201 is installed without cross-wiring , hinge the upper part into the DIN rail and push to let the lower part of the device snap into place (1). The device is released in the reverse order, after the quick fastener has been removed with a screw driver (2). B To release RCD F 200/FS 201 that are cross-wired with System pro M compact busbars, first remove the clamping screws. Then, pull the lower part of the F 200/FS 201 forwards (1) and lift it straight up (1a), then, the quick fastener will recede (1b). C The busbar is deallocated and the RCD F 200/FS 201 can be pulled out by lifting the device forwards (2). D The cross-wiring is re-inserted in the reverse order. First, open the clamping screws and pull out the quick fastener until it locks into place for the first time (3). Then, take the RCD F 200/FS 201 and insert it with the rear terminal side onto the pins of the System pro M compact busbar (4), turn it into the direction of the DIN rail (4a) and shift it vertically downwards (4b), to let the quick fastener snap back into place (4c). Attention: Do not forget to re-tighten the clamping screws. snap on release pro M compact busbar Operation F 200/FS 201 is switched ON or OFF with the blue operating lever. SK 0269 Z 98 SK 0012 Z 96 pro M compact busbar 2CDC 032 138 F0203 Connection Feeder optional, top or bottom. Ensure that conductors are connected correctly and firmly. If the 4-pole RCCB is operated as a 2-pole RCCB, use terminals 5 and 7 or, as the case may be, 6 and 8 to make sure that the test button function of the RCCB is working. In the case of a three-phase system with Un = 127/230 V (without neutral N), terminals 4 and 8 must be bridged. pin SK 0272 Z 98 pro M compact busbar SK 0268 Z 98 pin SK 0167 Z 99 D Insertion when pro M compact cross wiring remains in place C Removal when pro M compact cross wiring remains in place quick fastener B Detaching when pro M compact cross wiring remains in place SK 0267 Z 98 SK 0266 Z 98 A Assembly, disassembly without pro M compact cross wiring Operating test To test proper functioning, press the blue test button when the device is switched ON, the RCCB must trip immediately (the knob jumps into the 0" switching position). It is necessary to test the RCD halfyearly, if no other regional or user specified additional test are required. 22 System pro M compact (R) Residual-current-operated circuit-breakers F 200 series/FS 201 Test of protective measure Except for the operating test, the effectiveness of the protection provided within the installation must be tested according to the applicable codes of practice. For RCD protection, the maximum permissible earthing resistance values are as follows: max. touch voltage UL max. earthing resistance at nominal residual current 10 mA 30 mA 100 mA 300 mA 500 mA 25 V 50 V 2500 5000 833 1666 250 500 83 166 50 100 Malfunctioning The high-quality STOTZ residual-current-operated circuit-breakers are thorougly adjusted and tested in our works. Where damage occurs (caused e.g. by transport, storage, etc.) no repair work must be undertaken. If the device responds immediately after putting the RCCB into operation, check the downstream active circuit and any connected currentconsuming apparatus for earth fault current. Remove insulation faults or connections between the neutral conductor and the protective conductor existing in load circuit. Where the RCCB does not trip in the first operating test after pressing the test button, check first whether the test circuit is connected correctly. Where none of the above causes apply, or should the operating test be completed unsuccessfully, the RCCB must be replaced. Opening the device will lead to a loss of warranty. SK 0038 Z 94 SK 0005 Z 97 Examples for the protection against electric shock TN-S system (protective multiple earthing) separate neutral and protective conductors throughout the network TN-C-S system neutral and protective conductor (PEN) combined in one part of the network. SK 0040 Z 94 SK 0017 Z 95 only indicated by line isolation monitor TT system IT system The residual-current-operated circuit-breaker trips if a double fault occurs, as e.g. is indicated as fault 1 and fault 2 above. Explanation of type codes L1, L2, L3 line" phase conductor I insulation" PE protection earth" C combined" PE and N (PEN) N neutral" S separated" PE and N PEN PE and N combined T terre" direct bond to earth ..." terms used in international IEC standard 23 Busbars for series S 200, S 200 M, F 200, FS 201 System pro M compact (R) Description The newly developed pro M compact cross wiring busbar system includes everything that is needed for secure and economic connections of distribution build-in devices of the series S 200 and F 200. The optimised quick fastener of the S 200 series, F 200 , when used together with the System pro M compact cross wiring busbars, makes removing and inserting devices a quick and easy job, and the cross wiring of other devices remains in place, at that. Busbars are supplied ready-to-use and in standard lengths, time-consuming cutting to length or end caps are no longer required. MCBs and RCCBs of the customary System pro M technology can also be easily cross-wired with the new System pro M compact busbars. Technical data specifications: VDE 0660 Part 500, DIN EN 60439-1: 1994 test surge voltage: (1,2/50) 6,2 kV busbar material: SF-Cu F 24 short-circuit withstand capacity: 25 kA insulating profile material: plastic, temperature resistant 90 C flame-retardant, self-extinguishing dioxine- and halogene-free climatic resistance: constant climate L23/83; 40/92 55/20 according to DIN 50 015 humid heat, 28 cycles ( IEC 68 Part 2 - 30) busbar cross section: 10 mm2 insulation coordination: April 1997 (IEC 664) acc. to VDE 0110 Part 1 max. operating voltage: 440 V - overvoltage category: III rated surge voltage: 4 kV - pollution degree: 2 Load capability depending on the feed point bar cross section 10 mm2 16 mm2 max. busbar current IS/phase 63 A 80 A max. current in branch IE/phase 100 A 130 A* * If the device is fed via the device terminal, ensure that - irrespective of the current carrying capacity (IS) of the busbar the following values are not exceeded: For devices up to and including 40 A In max. 110 A and for 50/63 A In max. 140 A. SK 0063 Z 91 incoming supply within the busbar or centre-fed SK 0062 Z 91 incoming supply at the beginning of the busbar If the device is centre-fed (see picture to the right), ensure that the combined outgoing currents a1 ...an per branch do not exceed the max. busbar current IS/phase referred to above. 24 System pro M compact (R) Miniature circuit-breakers S 200/S 200 M Residual-current-operated circuit breakers F 200/FS 201 Dimensions measurements in mm SK 0136 Z 01 Dimensions 1-pole 2-pole 1 + NA 3-pole 4-pole 3 + NA 2-pole SK 0046 Z 02 SK 0111 Z 99 S 201, S 202, S 203, S 204 Supplementary devices 4-pole S2C-S/H 6 R S2C-H 6 R S2C-A... S2C-UA... SK 0047 Z 02 F 202, F 204, F 204 S SK 0058 Z 01 FS 201 1-pole 2-pole 3-pole 4-pole S 201 H, S 202 H, S 203 H, S 204 H 25 System pro M compact (R) Accessories Dimensions Terminal covers PCD 2 N SK 0136 Z 96 measurements in mm PCD 4 N PCD 6 N SK 0137 Z 96 PCD 8 N SK 0138 Z 96 SK 0078 Z98 SK 0079 Z98 Enclosure of moulded-plastic QES 4/3 N QES 6/3 N SK 0131 Z 94 Flush frame type S 500 - ME 1 S 500 - ME 2 S 500 - ME 3 dim. L max. No. of modules (1 module = 17.5 mm) 38 mm 88 mm 184 mm for 2 Module for 5 Module for 10 Module Mounting rails SK 0150 Z 93 In the case of DSW 1, the drill holes are vertical 26 name A A1 DSW DSW DSW DSW DSW 17.5 35 52.5 70 105 15 20 37.5 55 90 2 3 4 6 auxiliary contact bridge HKB 2CDC 062 149 F0203 2CDC 062 263 F0203 PS 1/6 2CDC 062 255 F0203 2CDC 062 146 F0203 PS 1/2 PS 1/9 PS 1/12 2CDC 062 148 F0203 2CDC 062 142 F0203 2CDC 062 141 F0203 2CDC 062 140 F0203 2CDC 062 145 F0203 2CDC 062 139 F0203 System pro M compact (R) Busbars Dimensions Dimensions measurements in mm PS 3/6 PS 3/9 PS 3/12 PS 3/12 FI PS 3/60 27 PS 2/48 PS 3/39 H PS 3/48 H 28 2CDC 062 267 F0203 2CDC 062 260 F0203 2CDC 062 269 F0203 2CDC 062 252 F0203 PS 2/58 2CDC 062 143 F0203 2CDC 062 261 F0203 2CDC 062 265 F0203 2CDC 062 253 F0203 PS 2/12 2CDC 062 148 F0203 2CDC 062 251 F0203 System pro M compact (R) Busbars Dimensions Dimensions measurements in mm PS 3/12 FI H PS 4/12 PS 4/60 PS 4/58 N PS 3/12 E 463 System pro M compact (R) Miniature circuit-breakers S 200 series S 200-D Selection table D 6000 No. of poles rated current In A order details type code order code bbn 40 16779 EAN 1 0.5 1 1.6 S 201-D 0.5 S 201-D 1 S 201-D 1.6 2CDS 251 001 R0981 2CDS 251 001 R0011 2CDS 251 001 R0971 52993 8 52994 5 52995 2 2 3 4 S 201-D 2 S 201-D 3 S 201-D 4 2CDS 251 001 R0021 2CDS 251 001 R0031 2CDS 251 001 R0041 52996 9 52997 6 52998 3 6 8 10 S 201-D 6 S 201-D 8 S 201-D 10 2CDS 251 001 R0061 2CDS 251 001 R0081 2CDS 251 001 R0101 52999 0 53000 2 53001 9 13 16 20 S 201-D 13 S 201-D 16 S 201-D 20 2CDS 251 001 R0131 2CDS 251 001 R0161 2CDS 251 001 R0201 53002 6 53003 3 53004 0 25 32 40 S 201-D 25 S 201-D 32 S 201-D 40 2CDS 251 001 R0251 2CDS 251 001 R0321 2CDS 251 001 R0401 53005 7 53006 4 53007 1 50 63 S 201-D 50 S 201-D 63 2CDS 251 001 R0501 2CDS 251 001 R0631 55199 1 55200 4 0.5 1 1.6 S 202-D 0.5 S 202-D 1 S 202-D 1.6 2CDS 252 001 R0981 2CDS 252 001 R0011 2CDS 252 001 R0971 53048 4 53049 1 53050 7 2 3 4 S 202-D 2 S 202-D 3 S 202-D 4 2CDS 252 001 R0021 2CDS 252 001 R0031 2CDS 252 001 R0041 53051 4 53052 1 53053 8 6 8 10 S 202-D 6 S 202-D 8 S 202-D 10 2CDS 252 001 R0061 2CDS 252 001 R0081 2CDS 252 001 R0101 53054 5 53055 2 53058 3 13 16 20 S 202-D 13 S 202-D 16 S 202-D 20 2CDS 252 001 R0131 2CDS 252 001 R0161 2CDS 252 001 R0201 53060 6 53061 3 53063 7 25 32 40 S 202-D 25 S 202-D 32 S 202-D 40 2CDS 252 001 R0251 2CDS 252 001 R0321 2CDS 252 001 R0401 53064 4 53065 1 53066 8 50 63 S 202-D 50 S 202-D 63 2CDS 252 001 R0501 2CDS 252 001 R0631 55203 5 55204 2 0.5 1 1.6 S 203-D 0.5 S 203-D 1 S 203-D 1.6 2CDS 253 001 R0981 2CDS 253 001 R0011 2CDS 253 001 R0971 53081 1 53082 8 53083 5 2 3 4 S 203-D 2 S 203-D 3 S 203-D 4 2CDS 253 001 R0021 2CDS 253 001 R0031 2CDS 253 001 R0041 53084 2 53085 9 53086 6 6 8 10 S 203-D 6 S 203-D 8 S 203-D 10 2CDS 253 001 R0061 2CDS 253 001 R0081 2CDS 253 001 R0101 53088 0 53089 7 53090 3 13 16 20 S 203-D 13 S 203-D 16 S 203-D 20 2CDS 253 001 R0131 2CDS 253 001 R0161 2CDS 253 001 R0201 53091 0 53092 7 53093 4 25 32 40 S 203-D 25 S 203-D 32 S 203-D 40 2CDS 253 001 R0251 2CDS 253 001 R0321 2CDS 253 001 R0401 53094 1 53095 8 53096 5 50 63 S 203-D 50 S 203-D 63 2CDS 253 001 R0501 2CDS 253 001 R0631 55205 9 55206 6 0.5 1 1.6 S 204-D 0.5 S 204-D 1 S 204-D 1.6 2CDS 254 001 R0981 2CDS 254 001 R0011 2CDS 254 001 R0971 53112 2 53113 9 53114 6 2 3 4 S 204-D 2 S 204-D 3 S 204-D 4 2CDS 254 001 R0021 2CDS 254 001 R0031 2CDS 254 001 R0041 53115 3 53116 0 53117 7 6 8 10 S 204-D 6 S 204-D 8 S 204-D 10 2CDS 254 001 R0061 2CDS 254 001 R0081 2CDS 254 001 R0101 53118 4 53119 1 53120 7 13 16 20 S 204-D 13 S 204-D 16 S 204-D 20 2CDS 254 001 R0131 2CDS 254 001 R0161 2CDS 254 001 R0201 53121 4 53122 1 53123 8 25 32 40 S 204-D 25 S 204-D 32 S 204-D 40 2CDS 254 001 R0251 2CDS 254 001 R0321 2CDS 254 001 R0401 53129 0 53130 6 53131 3 50 63 S 204-D 50 S 204-D 63 2CDS 254 001 R0501 2CDS 254 001 R0631 55209 7 55210 3 SK 018 B 01 3 UBmax 440 V 60 V ... SK 019 B 01 2 UBmax 440 V 125 V ... SK 020 B 019 3 UBmax 440 V SK 030 B 01 4 UBmax 440 V 125 V ... price 1 piece price group suitable for flow-type heaters 12 kW suitable for flow-type heaters 21, 24 and 27 kW suitable for flow-type heaters 18 kW UBmax 125 V ... with 2 poles connected in series w'ght 1 pc. kg pack. unit pc. 0.125 10/40 0.250 5/20 0.375 3/12 0.500 2 33 System pro M compact (R) Miniature circuit-breakers S 200 series M S 200 M-B Selection table B No. of poles 1 10000 3 UBmax 440 V 60 V ... SK 032 B 02 2 UBmax 440 V 125 V ... 3 UBmax 440 V 4 UBmax 440 V 125 V ... rated current In A order details type code order code bbn 40 16779 EAN 6 10 13 S 201 M-B 6 S 201 M-B 10 S 201 M-B 13 2CDS 271 001 R0065 2CDS 271 001 R0105 2CDS 271 001 R0135 54942 4 54943 1 54944 8 16 20 25 S 201 M-B 16 S 201 M-B 20 S 201 M-B 25 2CDS 271 001 R0165 2CDS 271 001 R0205 2CDS 271 001 R0255 54945 5 54946 2 54947 9 32 40 50 S 201 M-B 32 S 201 M-B 40 S 201 M-B 50 2CDS 271 001 R0325 2CDS 271 001 R0405 2CDS 271 001 R0505 54948 6 54949 3 54381 1 63 S 201 M-B 63 2CDS 271 001 R0635 54382 8 6 10 13 S 202 M-B 6 S 202 M-B 10 S 202 M-B 13 2CDS 272 001 R0065 2CDS 272 001 R0105 2CDS 272 001 R0135 54958 5 54959 2 54960 8 16 20 25 S 202 M-B 16 S 202 M-B 20 S 202 M-B 25 2CDS 272 001 R0165 2CDS 272 001 R0205 2CDS 272 001 R0255 54961 5 54962 2 54963 9 32 40 50 S 202 M-B 32 S 202 M-B 40 S 202 M-B 50 2CDS 272 001 R0325 2CDS 272 001 R0405 2CDS 272 001 R0505 54964 6 54965 3 54385 9 63 S 202 M-B 63 2CDS 272 001 R0635 54386 6 6 10 13 S 203 M-B 6 S 203 M-B 10 S 203 M-B 13 2CDS 273 001 R0065 2CDS 273 001 R0105 2CDS 273 001 R0135 54966 0 54967 7 54968 4 16 20 25 S 203 M-B 16 S 203 M-B 20 S 203 M-B 25 2CDS 273 001 R0165 2CDS 273 001 R0205 2CDS 273 001 R0255 54969 1 54970 7 54971 4 32 40 50 S 203 M-B 32 S 203 M-B 40 S 203 M-B 50 2CDS 273 001 R0325 2CDS 273 001 R0405 2CDS 273 001 R0505 54972 1 54973 8 54387 3 63 S 203 M-B 63 2CDS 273 001 R0635 54388 0 6 10 13 S 204 M-B 6 S 204 M-B 10 S 204 M-B 13 2CDS 274 001 R0065 2CDS 274 001 R0105 2CDS 274 001 R0135 54982 0 54983 7 54984 4 16 20 25 S 204 M-B 16 S 204 M-B 20 S 204 M-B 25 2CDS 274 001 R0165 2CDS 274 001 R0205 2CDS 274 001 R0255 54985 1 54986 8 54987 5 32 40 50 S 204 M-B 32 S 204 M-B 40 S 204 M-B 50 2CDS 274 001 R0325 2CDS 274 001 R0405 2CDS 274 001 R0505 54988 2 54989 9 54391 0 63 S 204 M-B 63 2CDS 274 001 R0635 54392 7 price 1 piece price group suitable for flow-type heaters 12 kW suitable for flow-type heaters 21, 24 and 27 kW suitable for flow-type heaters 18 kW UBmax 125 V ... with 2 poles connected in series w'ght 1 pc. kg pack. unit pc. 0.125 10/40 0.250 5/20 0.375 3/12 0.500 2 41 System pro M compact (R) Miniature circuit-breakers S 200 series M S 200 M-B Selection table B No. of poles 10000 rated current In A order details type code price 1 piece price group w'ght 1 pc. kg pack. unit pc. 0.250 50/40 0.500 2/20 With disconnecting neutral NA 3 SK 032 B 02 1 + NA UBmax 440 V 60 V ... 3 + NA UBmax 440 V 6 10 13 S 201 M-B 6 NA S 201 M-B 10 NA S 201 M-B 13 NA 2CDS 271 103 R0065 2CDS 271 103 R0105 2CDS 271 103 R0135 54950 9 54951 6 54952 3 16 20 25 S 201 M-B 16 NA S 201 M-B 20 NA S 201 M-B 25 NA 2CDS 271 103 R0165 2CDS 271 103 R0205 2CDS 271 103 R0255 54953 0 54954 7 54955 4 32 40 50 S 201 M-B 32 NA S 201 M-B 40 NA S 201 M-B 50 NA 2CDS 271 103 R0325 2CDS 271 103 R0405 2CDS 271 103 R0505 54956 1 54957 8 54383 5 63 S 201 M-B 63 NA 2CDS 271 103 R0635 54384 2 6 10 13 S 203 M-B 6 NA S 203 M-B 10 NA S 203 M-B 13 NA 2CDS 273 103 R0065 2CDS 273 103 R0105 2CDS 273 103 R0135 54974 5 54975 2 54976 9 16 20 25 S 203 M-B 16 NA S 203 M-B 20 NA S 203 M-B 25 NA 2CDS 273 103 R0165 2CDS 273 103 R0205 2CDS 273 103 R0255 54977 6 54978 3 54979 0 32 40 50 S 203 M-B 32 NA S 203 M-B 40 NA S 203 M-B 50 NA 2CDS 273 103 R0325 2CDS 273 103 R0405 2CDS 273 103 R0505 54980 6 54981 3 54389 7 63 S 203 M-B 63 NA 2CDS 273 103 R0635 54390 3 suitable for flow-type heaters 12 kW suitable for flow-type heaters 18 kW 42 order code bbn 40 16779 EAN suitable for flow-type heaters 21, 24 and 27 kW 0.580 System pro M compact (R) Miniature circuit-breakers S 200 series M S 200 M-C Selection table C No. of poles 1 10000 SK 044 B 02 3 UBmax 440 V 60 V ... SK 045 B 02 2 UBmax 440 V 125 V ... SK 046 B 02 3 UBmax 440 V 4 UBmax 440 V 125 V ... rated current In A order details type code order code bbn 40 16779 EAN 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 S 201 M-C 0.5 S 201 M-C 1 S 201 M-C 1.6 S 201 M-C 2 S 201 M-C 3 S 201 M-C 4 S 201 M-C 6 S 201 M-C 8 S 201 M-C 10 S 201 M-C 13 S 201 M-C 16 S 201 M-C 20 S 201 M-C 25 S 201 M-C 32 S 201 M-C 40 S 201 M-C 50 S 201 M-C 63 2CDS 271 001 R0984 2CDS 271 001 R0014 2CDS 271 001 R0974 2CDS 271 001 R0024 2CDS 271 001 R0034 2CDS 271 001 R0044 2CDS 271 001 R0064 2CDS 271 001 R0084 2CDS 271 001 R0104 2CDS 271 001 R0134 2CDS 271 001 R0164 2CDS 271 001 R0204 2CDS 271 001 R0254 2CDS 271 001 R0324 2CDS 271 001 R0404 2CDS 271 001 R0504 2CDS 271 001 R0634 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 S 202 M-C 0.5 S 202 M-C 1 S 202 M-C 1.6 S 202 M-C 2 S 202 M-C 3 S 202 M-C 4 S 202 M-C 6 S 202 M-C 8 S 202 M-C 10 S 202 M-C 13 S 202 M-C 16 S 202 M-C 20 S 202 M-C 25 S 202 M-C 32 S 202 M-C 40 S 202 M-C 50 S 202 M-C 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 price 1 piece price group w'ght 1 pc. kg pack. unit pc. 54990 5 54992 9 54991 2 54993 6 54994 3 54995 0 54996 7 54997 4 54998 1 54999 8 55000 0 55001 7 55002 4 55003 1 55004 8 54393 4 54394 1 0.125 10/40 2CDS 272 001 R0984 2CDS 272 001 R0014 2CDS 272 001 R0974 2CDS 272 001 R0024 2CDS 272 001 R0034 2CDS 272 001 R0044 2CDS 272 001 R0064 2CDS 272 001 R0084 2CDS 272 001 R0104 2CDS 272 001 R0134 2CDS 272 001 R0164 2CDS 272 001 R0204 2CDS 272 001 R0254 2CDS 272 001 R0324 2CDS 272 001 R0404 2CDS 272 001 R0504 2CDS 272 001 R0634 55020 8 55022 2 55021 5 55023 9 55024 6 55025 3 55026 0 55027 7 55028 4 55029 1 55030 7 55031 4 55032 1 55033 8 55034 5 54397 2 54398 9 0.250 5/20 S 203 M-C 0.5 S 203 M-C 1 S 203 M-C 1.6 S 203 M-C 2 S 203 M-C 3 S 203 M-C 4 S 203 M-C 6 S 203 M-C 8 S 203 M-C 10 S 203 M-C 13 S 203 M-C 16 S 203 M-C 20 S 203 M-C 25 S 203 M-C 32 S 203 M-C 40 S 203 M-C 50 S 203 M-C 63 2CDS 273 001 R0984 2CDS 273 001 R0014 2CDS 273 001 R0974 2CDS 273 001 R0024 2CDS 273 001 R0034 2CDS 273 001 R0044 2CDS 273 001 R0064 2CDS 273 001 R0084 2CDS 273 001 R0104 2CDS 273 001 R0134 2CDS 273 001 R0164 2CDS 273 001 R0204 2CDS 273 001 R0254 2CDS 273 001 R0324 2CDS 273 001 R0404 2CDS 273 001 R0504 2CDS 273 001 R0634 55035 2 55037 6 55036 9 55038 3 55039 0 55040 6 55041 3 55042 0 55043 7 55044 4 55045 1 55046 8 55047 5 55048 2 55049 9 54399 6 54400 9 0.375 3/12 S 204 M-C 0.5 S 204 M-C 1 S 204 M-C 1.6 S 204 M-C 2 S 204 M-C 3 S 204 M-C 4 S 204 M-C 6 S 204 M-C 8 S 204 M-C 10 S 204 M-C 13 S 204 M-C 16 S 204 M-C 20 S 204 M-C 25 S 204 M-C 32 S 204 M-C 40 S 204 M-C 50 S 204 M-C 63 2CDS 274 001 R0984 2CDS 274 001 R0014 2CDS 274 001 R0974 2CDS 274 001 R0024 2CDS 274 001 R0034 2CDS 274 001 R0044 2CDS 274 001 R0064 2CDS 274 001 R0084 2CDS 274 001 R0104 2CDS 274 001 R0134 2CDS 274 001 R0164 2CDS 274 001 R0204 2CDS 274 001 R0254 2CDS 274 001 R0324 2CDS 274 001 R0404 2CDS 274 001 R0504 2CDS 274 001 R0634 55065 9 55067 3 55066 6 55068 0 55069 7 55070 3 55071 0 55072 7 55073 4 55074 1 55075 8 55076 5 55077 2 55078 9 55079 6 54403 0 54404 7 0.500 2 suitable for flow-type heaters 12 kW suitable for flow-type heaters 21, 24 and 27 kW suitable for flow-type heaters 18 kW UBmax 125 V ... with 2 poles connected in series 43 System pro M compact (R) Miniature circuit-breakers S 200 series M S 200 M-C Selection table C No. of poles 10000 rated current In A order details type code order code bbn 40 16779 EAN price 1 piece price group w'ght 1 pc. kg pack. unit pc. 0.250 5 With disconnecting neutral NA 3 SK 032 B 02 1 + NA UBmax 440 V 60 V ... 3 + NA Attention: S 200 M, B and C with integrated auxiliary contact on request. UBmax 440 V 0.5 1 1.6 S 201 M-C 0.5 NA S 201 M-C 1 NA S 201 M-C 1.6 NA 2CDS 271 103 R0984 2CDS 271 103 R0014 2CDS 271 103 R0974 55005 5 55007 9 55006 2 2 3 4 S 201 M-C 2 NA S 201 M-C 3 NA S 201 M-C 4 NA 2CDS 271 103 R0024 2CDS 271 103 R0034 2CDS 271 103 R0044 55008 6 55009 3 55010 9 6 8 10 S 201 M-C 6 NA S 201 M-C 8 NA S 201 M-C 10 NA 2CDS 271 103 R0064 2CDS 271 103 R0084 2CDS 271 103 R0104 55011 6 55012 3 55013 0 13 16 20 S 201 M-C 13 NA S 201 M-C 16 NA S 201 M-C 20 NA 2CDS 271 103 R0134 2CDS 271 103 R0164 2CDS 271 103 R0204 55014 7 55015 4 55016 1 25 32 40 S 201 M-C 25 NA S 201 M-C 32 NA S 201 M-C 40 NA 2CDS 271 103 R0254 2CDS 271 103 R0324 2CDS 271 103 R0404 55017 8 55018 5 55019 2 50 63 S 201 M-C 50 NA S 201 M-C 63 NA 2CDS 271 103 R0504 2CDS 271 103 R0634 54395 8 54396 5 0.290 0.5 1 1.6 S 203 M-C 0.5 NA S 203 M-C 1 NA S 203 M-C 1.6 NA 2CDS 273 103 R0984 2CDS 273 103 R0014 2CDS 273 103 R0974 55051 2 55052 9 55050 5 0.500 2 3 4 S 203 M-C 2 NA S 203 M-C 3 NA S 203 M-C 4 NA 2CDS 273 103 R0024 2CDS 273 103 R0034 2CDS 273 103 R0044 55053 6 55054 3 55055 0 6 8 10 S 203 M-C 6 NA S 203 M-C 8 NA S 203 M-C 10 NA 2CDS 273 103 R0064 2CDS 273 103 R0084 2CDS 273 103 R0104 55056 7 55057 4 55058 1 13 16 20 S 203 M-C 13 NA S 203 M-C 16 NA S 203 M-C 20 NA 2CDS 273 103 R0134 2CDS 273 103 R0164 2CDS 273 103 R0204 55059 8 55060 4 55061 1 25 32 40 S 203 M-C 25 NA S 203 M-C 32 NA S 203 M-C 40 NA 2CDS 273 103 R0254 2CDS 273 103 R0324 2CDS 273 103 R0404 55062 8 55063 5 55064 2 50 63 S 203 M-C 50 NA S 203 M-C 63 NA 2CDS 273 103 R0504 2CDS 273 103 R0634 54401 6 54402 3 suitable for flow-type heaters 12 kW 2 0.580 suitable for flow-type heaters 21, 24 and 27 kW suitable for flow-type heaters 18 kW System pro M compact (R) Supplementary devices MCB's Range S 200/S 200 M Description order details SK 011 B 02 type code SK 209 B 02 SC-S/H6R S 2C-A 44 order code bbn 40 16779 EAN price 1 piece price group w'ght 1 pc. kg pack. unit pc. Signalcontact/Auxiliary switch (universal) Retrofittable to the right side of MCB's, RCB's and Shunt trip's 1 change over S 2C-S/H6R 2CDS 200 922 R0001 56381 9 0.04 1 Auxiliary contact Retrofittable to the right side of MCB's 1 change over S 2C-H6R 2CDS 200 912 R0001 56382 6 0.04 1 S 2C-A1 2CDS 200 909 R0001 57099 2 0.15 1 S 2C-A2 2CDS 200 909 R0002 57100 5 2CDS 200 911 R0001 2CDS 200 911 R0002 2CDS 200 911 R0003 2CDS 200 911 R0004 2CDS 200 911 R0005 2CDS 200 911 R0006 57101 2 57102 9 57103 6 57104 3 57105 0 57106 7 0.09 1 Shunt trip AC/DC 12 ... 60 V AC 110 ... 415 V und DC 110 ... 250 V Undervoltage release (in preparation) DC 12 V S 2C-UA 12 AC/DC 24 V S 2C-UA 24 AC/DC 48 V S 2C-UA 48 AC/DC 110 V S 2C-UA 110 AC/DC 220 V S 2C-UA 220 AC 380 V S 2C-UA 380 System pro M compact (R) RCCBs and RCBOs and their fields of applications Areas of application DIN VDE... Required sensitivity InmA F 200 F 660 F 670 F 200 F 690 F 172 FS 200 F220 F 804 S In apartments 32 A Socket-outlets up to 20 A Outdoor lightning installations Fire protection in high-risk or high-danger areas Rooms with bath tub or shower Swimming pools Construction sites Socket-outlet circuits up to 32 A and other socket-outlet circuits 0100 - 739 10...30 0100 - 470 10...30 0100 - 714 10...30 F 200 F 660 F 670 F 200 F 660 F 670 0100 - 482 10 u. 30 0100 - 701 10...30 0100 - 702 10...30 F 200 F 660 F 670 0100 - 704 BG F&E 10...30 300...500 F 200 F 660 F 670 F 172 FS 200 F 200 F 690 F 172 FS 200 F 172 FS 200 F 200 F 690 F 172 FS 200 F 220 F 804 Type B Agricultural and horticultural properties, General socket-outlet circuits 300...500 0100 - 705 F 200 F 660 F 670 F 200 F 690 10...30 Feed points for caravans Camp sites 0100 - 708 Berths Socket-outlets 0100 - 721 Temporary buildings, carny carriages and caravans, Feed points 0100 - 722 Medical rooms Group 1 Group 2 a Group 2 b 0100 - 710 Equipment of power installations with electronic items I b type A, test for type B 0160 DIN EN 50 178 10...30 10...30 30 and 300 at In 32 A 10...30 10...30 300 4kVA 10...30 > 4kVA 300 F 200 F 660 F 670 F 172 FS 200 F 200 F 660 F 670 F 172 FS 200 F 200 F 660 F 670 F 200 F 690 F 172 FS 200 F 200 F 660 F 670 F 200 F 690 F 172 FS 200 F 220 F 804 Type B F 200 F 660 F 670 F 200 F 690 Photovoltaics 0100 - 712 E EnBW F 172 FS 200 F 270 P 270 30 F 172 FS 200 F 220 F 804 Type B F 220 F 802 Type B Operating areas subject to fire hazards... VdS 2033: 2002 - 02 300 mA 51 Approvals and certifications by classification societies System pro M compact (R) MCB's and RCB's Type Approvals Ship classification associatons Sign of comformity BD 6 Code SEV Valid for CH DEMKO NEMKO SEMKO DK N S EL. CSA Inspect. SF CDN USA KEMA OVE CEBEC UTE VDE BV GL LRS DNV NL A B F D F D GB N 277/480 V~ S 200, B, C 1 - 4 pole S 200 M 1 - 4 pole F 200 - 16/25/ 40 - 0.01/ 0.03/0.1/ 0.3/0.5 F 200 A, AC, S 2/4 pole 16...63 A 0.01...0.5 A FS 201 B 6...40/0,03 A C 16/0,03 approved submitted for aproval/planed to be submitted Approved variants on request Approval not required Back-up protection usually required. For details contact your importer and/or inspector. Pub. No. 2CDC 002 001 D0203 ABB STOTZ-KONTAKT GmbH P.O. Box 10 16 80, 69006 Heidelberg, Germany Eppelheimer Strae 82, 69123 Heidelberg, Germany Telephone: +49 (0) 62 21 701- 0 Fax: +49 (0) 62 21 701-723 www.abb.de/stotz-kontakt 52