Digital Storage Oscilloscopes TBS1000B Series Datasheet Multiple-language user interface Small footprint and lightweight - Only 4.9 in. (124 mm) deep and 4.4 lb. (2 kg) Connectivity USB 2.0 host port on the front panel for quick and easy data storage USB 2.0 device port on rear panel for easy connection to a PC Seeing signal details The TBS1000B Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features - including USB connectivity, 34 automated measurements, limit testing, data logging, frequency counter, TrendPlotTM and a contextsensitive help menu - the TBS1000B Series oscilloscopes helps you get more done, in less time. To properly analyze signals you need to make sure that you can see them in enough detail. The TBS1000B comes standard with a 7-inch high resolution TFT display for a clear view of all of your signals and critical on screen information. The instrument is further enhanced by a user interface inspired by the award winning Tektronix MSO/DPO series of instruments. The interface is easy to use, provides quick access to all of the oscilloscope functions and includes a high resolution "Pan & Zoom" feature enabling you to see even more signal details of up to 10 times normal resolution. Key performance specifications 200MHz, 150 MHz, 100 MHz, 70 MHz and 50 MHz bandwidth models 2-channel models Up to 2 GS/s sample rate on all channels 2.5k point record length on all channels Advanced triggers including pulse and line-selectable video triggers Key features 7 inch WVGA (800X480) Active TFT Color Display 34 automated measurements The zoom function shows details in an event of up to 10X the normal view. Dual window FFT, simultaneously monitors both the time and frequency domains Built-in waveform limit and TrendPlotTM testing Dual channel frequency counter Zoom Function Automated, extended data logging feature Autoset and auto-ranging functions Built-in context-sensitive help www.tektronix.com 1 Datasheet Digital precision for accurate measurements With up to 200 MHz bandwidth, 2 GS/s maximum sample rate and 3% vertical measurement accuracy the TBS1000B allows you to see the details of your signals. With the Tektronix proprietary sampling technology there are no compromises, you will get the stated real-time sampling rate on all channels, all the time with at least of 10X oversampling. The sampling performance is not reduced when changing horizontal settings or when using multiple channels, enabling you to see the true characteristics of your signals. Quickly analyze signals with the standard 34 automated measurements. A dedicated front panel button provides quick access to the FFT function that is capable of showing both frequency and time domain waveforms simultaneously, which provides a convenient way to see the relationship between signals and the FFT results. See all the details other oscilloscopes might miss with Tektronix proprietary digital realtime sampling. Critical tools for troubleshooting your device The TBS1000B oscilloscope comes standard with a variety of advanced triggers used to debug today's complex circuitry. Flexible options for utilizing rising or falling edges, pulse widths and video trigger set-ups enable users to quickly isolate their signals of interest. Quickly perform an FFT with a dedicated front panel button. For accurate frequency measurements the TBS1000B also comes with built-in dual channel frequency counters. Independent control of each counter's trigger level provides an easy way to monitor two different signal frequencies simultaneously. The pulse trigger function can easily capture critical events. Once signals are captured, the TBS1000B offers advanced math and measurement capabilities making it easy to evaluate signal quality . Users can add, subtract and multiply waveforms or use any one of 34 automated measurements to quickly and reliably calculate important signal characteristics such as frequency, rise time or overshoot. Dual channel - 6 digit frequency counters come standard with all TBS1000 models. 2 www.tektronix.com TBS1000B Digital Storage Oscilloscopes Extensive monitoring and analysis tools Flexible data transfer Intermittent faults can be hard to evaluate, simply because they do not repeat often making them difficult to capture. The TrendPlotTM function helps find those faults by plotting measurement values over long periods of time. Select the measurement to capture on either or both channels and then set-up the oscilloscope to continuously monitor those measurements, plot the data on the display and simultaneously save the information to a USB thumb drive. Depending on the oscilloscope setting, you'll be able to capture data for minutes, hours or even days; the only limitation is the size of the thumb drive. The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data onto a USB memory device. This port also supports the built-in Data Logging feature which enables you to set up the oscilloscope to save user- specified triggered waveforms to a USB device for up to 24 hours. You can also select the "Infinite" option for continuous waveform monitoring. In the infinite mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full. The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms. To find intermittent faults the TrendPlot TM function can monitor measurements for long periods of time. Data logging enables automatic saving of triggered waveforms. Often, only Pass/Fail data is needed to determine if a signal is good. This can be accomplished easily with the TBS1000B Limit Test feature. The oscilloscope can be set-up to automatically monitor a source signals and output Pass or Fail results by evaluating whether the acquired waveform falls within predefined boundaries. The TBS1000B Limit Test feature allows users to create templates based on one or two independent reference waveforms, providing more flexibility when creating masks for complex signals. If a failure is detected, a series of specific actions can be triggered which include; stopping waveform acquisition, halting Limit Test functions, saving a screen image of the failed waveform, or any combination of the above. Designed to make your work easy The TBS1000B series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix. Intuitive operation The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency. The Limit Test feature provides a quick Pass/Fail comparison between any triggered input signal and a user- defined template. www.tektronix.com 3 Datasheet Help when you need it, where you need it Performance you can count on The built-in Help menu provides you with important information about your oscilloscope's features and functions. Help is provided in the same languages as the user interface. In addition to industry-leading service and support, every TBS1000B series oscilloscope comes backed with a 5-year warranty as standard. The context-sensitive help system provides important information specific to the task you are working on. 4 www.tektronix.com TBS1000B Digital Storage Oscilloscopes Specifications All specifications apply to all models unless noted otherwise. Model overview TBS1052B TBS1072B TBS1102B TBS1152B TBS1202B Bandwidth 1 50 MHz 70 MHz 100 MHz 150 MHz 200 MHz Channels 2 2 2 2 2 Sample rate on each channel 1.0 GS/s 1.0 GS/s 2 .0 GS/s 2 .0 GS/s 2 .0 GS/s Record length 2.5k points at all-time bases Vertical system - Analog channels Vertical resolution 8 bits Input sensitivity range 2 mV to 5 V/div on all models with calibrated fine adjustment DC gain accuracy 3%, from 10 mV/div to 5 V/div Maximum input voltage 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above Offset range 2 mV to 200 mV/div: 1.8 V >200 mV to 5 V/div: 45 V Bandwidth limit 20 MHz Input coupling AC, DC, GND Input impedance 1 M in parallel with 20 pF Vertical zoom Vertically expand or compress a live or stopped waveform Horizontal system -- Analog channels 1 Time base range 2.5 ns to 50 s/div Time base accuracy 50 ppm Horizontal zoom Horizontally expand or compress a live or stopped waveform Bandwidth is 20 MHz at 2 mV/div www.tektronix.com 5 Datasheet Input/Output ports USB interface USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge(R)-compatible printers GPIB interface Optional Data storage Nonvolatile storage Reference waveform display 2.5K point reference waveforms Waveform storage without USB flash drive 2.5K point Maximum USB flash drive size 64 GB Waveform storage with USB flash drive 96 or more reference waveforms per 8 MB Setups without USB flash drive 10 front-panel setups Setups with USB flash drive 4000 or more front-panel setups per 8 MB Screen images with USB flash 128 or more screen images per 8 MB (the number of images depends on file format selected) drive Save All with USB flash drive 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) Acquisition system Acquisition modes Peak Detect High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 s/div to 50 s/div Sample Sample data only Average Waveform averaged, selectable: 4, 16, 64, 128 Single Sequence Use the Single Sequence button to capture a single triggered acquisition sequence Roll At acquisition time base settings of >100 ms/div Trigger system External trigger input Included on all models Trigger modes Auto, Normal, Single Sequence Trigger types Edge (Rising/Falling) Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) Pulse Width (or Glitch) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s Trigger source Two channel models: CH1, CH2, Ext, Ext/5, AC Line Trigger view Displays trigger signal while Trigger View button is depressed. Trigger signal frequency readout Provides a frequency readout of the trigger source. 6 www.tektronix.com TBS1000B Digital Storage Oscilloscopes Waveform measurements Cursors Types Amplitude, Time Measurements T, 1/T, V Automatic measurements Period, Frequency, Pos Width, Neg Width, Rise Time, Fall Time, Maximum , Minimum , Peak-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Phase, Pos Pulse Cnt, Neg Pulse Cnt, Rise Edge Cn, Fall Edge Cn, Pos Duty, Neg Duty, Amplitude, Cycle Mean, Cursor Mean, Burst Width, Pos Overshoot, Neg Overshoot, Area, Cycle Area, High, Low, Delay RR, Delay RF, Delay FR, Delay FF Waveform math Arithmetic Add, Subtract, Multiply Math functions FFT FFT Windows: Hanning, Flat Top, Rectangular 2048 sample points Sources Two channel models: CH1 - CH2, CH2 - CH1, CH1 + CH2, CH1 x CH2 Autoset Autoset menu Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset Square wave Single Cycle, Multicycle, Rising or Falling Edge Sine wave Single Cycle, Multicycle, FFT Spectrum Video (NTSC, PAL, SECAM) Field: All, Odd, or Even Line: All or Selectable Line Number Autorange Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes. Frequency counter Resolution 6 digits Accuracy (typical) + 51 parts per million including all frequency reference errors and +1 count errors Frequency range AC coupled, 10 Hz minimum to rated bandwidth Frequency counter signal source Pulse width or edge selected trigger source Frequency counter measures selected trigger source at all times in pulse width and edge mode, including when the oscilloscope acquisition is halted due to changes in run status, or acquisition of a single shot event has completed. The frequency counter does not measure pulses that do not qualify as legitimate trigger events. Pulse Width mode: Counts pulses of enough magnitude inside the 250 ms measurement window that qualify as triggerable events (e.g. all narrow pulses in a PWM pulse train if set to "<" mode and the limit is set to a relatively small number). Edge Trigger mode: Counts all pulses of enough magnitude. Channels 2 channel www.tektronix.com 7 Datasheet Display system Interpolation Sin (x)/x Waveform styles Dots, vectors Persistence Off, 1 s, 2 s, 5 s, infinite Format YT and XY Physical characteristics Dimensions mm in. Height 158.0 6.22 Width 326.3 12.85 Depth 124.2 4.89 mm in. Height 266.7 10.5 Width 476.2 18.75 Depth 228.6 9.0 Shipping dimensions Weight kg lb. Instrument only 2.0 4.3 ...with accessories 2.2 4.9 mm in Width 482.6 19.0 Height 177.8 7.0 Depth 108.0 4.25 RM2000B rackmount Environmental Temperature Operating 0 to +50 C Nonoperating -40 to +71 C Humidity Operating and nonoperating Up to 85% RH at or below +40 C Up to 45% RH up to +50 C Altitude Operating and nonoperating Up to 3,000 m (9,843 ft.) Regulatory Electromagnetic compatibility Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework Safety UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001 8 www.tektronix.com TBS1000B Digital Storage Oscilloscopes Ordering information Models TBS1052B 50 MHz, 2 Ch, 1 GS/s, TFT DSO TBS1072B 70 MHz, 2 Ch, 1 GS/s, TFT DSO TBS1102B 100 MHz, 2 Ch, 2 GS/s, TFT DSO TBS1152B 150 MHz, 2 Ch, 2 GS/s, TFT DSO TBS1202B 200 MHz, 2 Ch, 2 GS/s, TFT DSO Language options Opt. L1 French overlay Opt. L2 Italian overlay Opt. L3 German overlay Opt. L4 Spanish overlay Opt. L5 Japanese overlay Opt. L6 Portuguese overlay Opt. L7 Simplified Chinese overlay Opt. L8 Traditional Chinese overlay Opt. L9 Korean overlay Opt. L10 Russian overlay Power plug options Opt. A0 North America power plug (115 V, 60 Hz) Opt. A1 Universal Euro power plug (220 V, 50 Hz) Opt. A2 United Kingdom power plug (240 V, 50 Hz) Opt. A3 Australia power plug (240 V, 50 Hz) Opt. A5 Switzerland power plug (220 V, 50 Hz) Opt. A6 Japan power plug (100 V, 110/120 V, 60 Hz) Opt. A10 China power plug (50 Hz) Opt. A11 India power plug (50 Hz) Opt. A12 Brazil power plug (60 Hz) Opt. A99 No power cord Service options Opt. D1 Calibration Data Report Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms. www.tektronix.com 9 Datasheet Probe option TBS1XX2B P2220 Replaces standard probes with P2220 probes (200 MHz passive voltage probes with 1x/ 10x attenuation) Standard accessories Accessory Description Passive probes, one per channel TPP0051: 50MHz passive probe for: TBS1052B TPP0101: 100 MHz passive probe for: TBS1072B, TBS1102B TPP0201: 200 MHz passive probe for: TBS1152B, TBS1202B Power cord (Please specify plug option) NIM/NIST Traceable certificate of calibration Printed documentation Installation and safety manual (English, Japanese, and Simplified Chinese) CD with customer documentation Customer documentation including detailed user manuals (English, French, German, Italian, Japanese, Korean, Portuguese, Russian, Simplified Chinese, Spanish, Traditional Chinese) 5-year warranty Covers labor and parts for defects in materials and workmanship for 5 years, excluding probes and accessories (probes and accessories are not covered by the oscilloscope warranty and service offerings. refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms) Recommended accessories Accessory Description TEK-USB-488 GPIB-to-USB converter AC2100 Soft carrying case for instrument HCTEK4321 Hard plastic carrying case for instrument (requires AC2100) RM2000B Rackmount kit 077-0444-xx Programmer manual - English only 077-0772-xx Service manual - English only 174-4401-xx USB host to device cable, 3 ft. long Recommended probes Probe Description TPP0051 10X passive probe, 50 MHz bandwidth TPP0101 10X passive probe, 100 MHz bandwidth TPP0201 10X passive probe, 200 MHz bandwidth P2220 1X/10X passive probe, 200 MHz bandwidth P6101B 1X passive probe (15 MHz, 300 V RMS CAT II rating) P6015A 1000X high-voltage passive probe (75 MHz) P5100A 100X high-voltage passive probe (500 MHz) P5200A 50 MHz, 50X/500X high-voltage differential probe P6021A 15 A, 60 MHz AC current probe P6022 6 A, 120 MHz AC current probe A621 2000 A, 5 to 50 kHz AC current probe A622 100 A, 100 kHz AC/DC current probe/BNC TCP303/TCPA300 150 A, 15 MHz AC/DC current probe/amplifier TCP305A/TCPA300 50 A, 50 MHz AC/DC current probe/amplifier 10 www.tektronix.com TBS1000B Digital Storage Oscilloscopes Probe Description TCP312A/TCPA300 30 A, 100 MHz AC/DC current probe/amplifier TCP404XL/TCPA400 500 A, 2 MHz AC/DC current probe/amplifier Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. www.tektronix.com 11 Datasheet ASEAN / Australasia (65) 6356 3900 Belgium 00800 2255 4835* Central East Europe and the Baltics +41 52 675 3777 Finland +41 52 675 3777 Hong Kong 400 820 5835 Japan 81 (3) 6714 3010 Middle East, Asia, and North Africa +41 52 675 3777 People's Republic of China 400 820 5835 Republic of Korea 001 800 8255 2835 Spain 00800 2255 4835* Taiwan 886 (2) 2722 9622 * European toll-free number. If not accessible, call: +41 52 675 3777 Austria 00800 2255 4835* Brazil +55 (11) 3759 7627 Central Europe & Greece +41 52 675 3777 France 00800 2255 4835* India 000 800 650 1835 Luxembourg +41 52 675 3777 The Netherlands 00800 2255 4835* Poland +41 52 675 3777 Russia & CIS +7 (495) 6647564 Sweden 00800 2255 4835* United Kingdom & Ireland 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Canada 1 800 833 9200 Denmark +45 80 88 1401 Germany 00800 2255 4835* Italy 00800 2255 4835* Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Norway 800 16098 Portugal 80 08 12370 South Africa +41 52 675 3777 Switzerland 00800 2255 4835* USA 1 800 833 9200 Updated 10 April 2013 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com. Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 10 Mar 2014 www.tektronix.com 3GW-30004-1 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Tektronix: TBS1072B TBS1052B-EDU TBS1072B-EDU TBS1202B-EDU TBS1152B-EDU TBS1102B-EDU TBS1202B TBS1102B TBS1052B TBS1152B