EC 40 www.recom-international.comAugust 2002
Selection Guide
ECONOLINE - DC/DC-Converter
RX and RY Series, 1 Watt, DIP14/SIP7, Regulated (Dual Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Part Part Input Output Output Efficiency
Number Number Voltage Voltage Current
DIP14 SiP7 (VDC) (VDC) (mA) (%)
RX-XX05D RY-XX05D 5, 9, 12, 15, 24 ±5 V ±100 54
RX-XX09D RY-XX09D 5, 9, 12, 15, 24 ±9 V ±55 58
RX-XX12D RY-XX12D 5, 9, 12, 15, 24 ±12 V ±42 62
RX-XX15D RY-XX15D 5, 9, 12, 15, 24 ±15 V ±33 65
RX-XX24D RY-XX24D 5, 9, 12, 15, 24 ±24 V ±21 65
Input Voltage ±5%
Input Filter Capacitor Type
Output Voltage Accuracy ±0.5%
Line Voltage Regulation ±0.05% / ±1.0%
Load Voltage Regulation (20% to 100% full load) ±0.5% / ±1.0%
Ripple and Noise (20MHz limited) 100mVp-p max.
Efficiency at Full Load 50% min.
Isolation Voltage 1.000VDC min.
Isolation Resistance (Viso = 500VDC) 10 GΩmin.
Isolation Capacitance 40pF min./72pF max.
Short Circuit Protection 1 Second
Switching Frequency at Full Load 30kHz min. / 88kHz max.
Operating Temperature -40°C to +71°C (see Graph)
Storage Temperature -55°C to +125°C
Package Weight RX types 2.7g
RY types 2.8g
●Controllable Output
●1kVDC Isolation
●UL94V-0 Package Material
●No Heatsink Required
●Fully Encapsulated
●No External Components
●Toroidal Magnetics
Features
Typical Applications