Cell Type CR-P2 Specifications W Nominal Capacity*1 Nominal Voltage Standard Discharge Current Continuous *2 Max. Discharge Current Pulse*3 Temperature Range Weight L 1400mAh 6V 10mA 1500mA 3500mA -4060 37g 34.8mm 19.5mm 35.8mm L W H H Dimensions *1 Nominal capacity is determined to an end voltage of 4.0V when the battery is allowed to discharge at a standard current level at 23oC. *2 Current value is determined to be the level at which 50% of the nominal capacity is obtained with an end voltage of 4.0V at 23 oC. *3 Current value for obtaining 2.0V cell voltage when pulse is applied for 15seconds at 50% discharge depth at 23 oC. Typical Characteristics Pulse Discharge Characteristics of CR-P2 Pulse Discharge Characteristics of CR-P2 7.0 7.0 Pu lse : 1 .2 A*3 s o n /7 s o ff In itia l Pu lse : 0 .9A*3s o n /2 7 s o ff Initia l 6.0 5.0 Cell Voltage(V) Cell Voltage(V) 6.0 o 23 C 4.0 o -2 0 C 3.0 2.0 0 600 400 200 100 0 800 1200 140 0 1600 180 0 Number of Cycles 2 3o C 5.0 4.0 o -2 0 C 3.0 2.0 0 200 400 600 800 1000 1200 Number of Cycles 1400 1600 1800 2000 Discharge Characteristics of CR-P2 7 .0 Load: 400ohm T e m p .: 2 3 oC In itia l Cell Voltage(V) 6 .0 5 .0 4 .0 3 .0 2 .0 0 10 20 30 40 50 60 70 Duration(hour) 80 90 100 110 120 130 140 Just measured data, not guaranteed.