Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.)
OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 1
The TE logo, Tyco Electronics and Raychem are trademarks. Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2006-2009 Tyco Electronics Corporation. All rights reserved.
INSULATION FLAWS:
Impulse Dielectric Test, 8.0 kV (peak)
PART NUMBER:
The "*" in the part numbers above shall be replaced by color code designators with
a slash separating the component wire colors.
1/ Example: AWG 22, black and brown component wires: 100A0121-22-0/1
COMPONENT WIRES - 100A0111
SPECIFICATION CONTROL DRAWING 100A0121
TWO CONDUCTOR CABLE, HALOGEN FREE, UNSHIELDED, UNJACKETED, 600 VOLT AC, 125°C 2-9-09 F
This specication sheet forms a part of the latest issue of Raychem Specication WCD 2015.
TITLE Date Revision
CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
DIAMETER MAXIMUM
WEIGHT
LOWER SPEC
LIMIT
TARGET
VALUE
UPPER SPEC
LIMIT
inches mm inches mm inches mm lbs/kft kg/km
100A0121-24-* 24 .086 2.19 .090 2.29 .094 2.39 4.96 7.39
100A0121-22-* 22 .099 2.51 .102 2.59 .105 2.66 6.88 10.25
100A0121-20-* 20 .115 2.93 .118 3.01 .121 3.08 10.26 15.29
100A0121-18-* 18 .133 3.38 .137 3.49 .141 3.59 15.06 22.44
100A0121-16-* 16 .145 3.68 .149 3.78 .153 3.88 18.94 28.22
100A0121-14-* 14 .179 4.54 .183 4.66 .188 4.78 29.77 44.35
100A0121-12-* 12 .213 5.41 .219 5.56 .225 5.72 43.32 64.54
100A0121-10-* 10 .262 6.66 .269 6.84 .276 7.02 68.54 102.13
CABLE RATINGS AND ADDITIONAL REQUIREMENTS