Telecom Fuses The FT600 fuse series is designed to assist telecommunications equipment manufacturers in complying with North American overcurrent protection requirements, including Telcordia GR1089, TIA-968-A (formerly FCC Part 68), and UL60950 3rd edition. The low profile and small footprint of the FT600 fuse provide a reliable, non-resettable overcurrent protection solution. The device offers low temperature-rise performance under sneak current fault events to prevent damage to circuit traces or multilayer boards. When used in conjunction with SiBarTM thyristor devices, it provides designers with a complete overcurrent/overvoltage protection solution to help them comply with regulatory standards. This fuse offering complements the telecom resettable PolySwitch device series for use in applications where intervention is desired after an overcurrent fault. Benefits Features * High density placement in multi-port system designs * Low profile and small footprint * Improved temperature rise performance over other * The lightning robust surface-mount fuse offers similar SMT fuse devices under sneak-current testing * The FT600 in conjunction with a SiBar overvoltage overcurrent protection in case of power fault events * Enables the design of equipment complying with protection device, assists designers in meeting applicable telecom specifications including UL60950, regulatory standards with no additional series TIA-968-A (formerly FCC Part 68), and Telcordia components GR-1089 * Low resistance 12 Applications * ADSL, ADSL2, ADSL2plus, SHDSL, VDSL linecards and modems * T1/E1 systems * Twisted-pair telecom ports requiring Telcordia GR-1089, UL60950 and FCC Part TIA-968-A (formerly FCC Part 68) compliance 85 To use this guide, follow the steps below: 1. Select your equipment type from the guide below. 2. Use the Key Device Selection Criteria (time-to-open, surface temperature) to determine best suitability for your application. 3. Use Agency Specification / Selection Guide on the next page to select a specific part number for each application based on the agency requirements. Application Customer premises equipment, IT equipment Analog modems, V.90 modems, ISDN modems, xDSL modems, ADSL splitters, phone sets, fax machines, answering machines, caller ID, internet appliances, PBX systems, POS terminals, wall plugs Access network equipment Remote terminals, line repeaters, multiplexers, cross-connects, WAN equipment Central office switching equipment Analog/POTS linecards, ISDN linecards, xDSL modems, ADSL/VDSL splitters, T1/E1 linecards, multiplexers, CSU/DSU, servers Key Device Selection Citeria Faster Cooler Surface Time-To-Open Temperature FT600-0500 FT600-2000 FT600-1250 SiBar Thyristor Surge Protectors* TVBxxxSC-L Telcordia GR-1089 TIA-968-A FT600-1250 FT600-2000 TVBxxxSC-L Telcordia GR-1089 TIA-968-A FT600-1250 FT600-2000 TVBxxxSC-L Specification UL 60950 TIA-968-A Telecom Fuses Protection Application Guide for Telecommunications and Networking Devices Notes: This list is not exhaustive. Raychem Circuit Protection welcomes our customers' input for additional application ideas for overcurrent protection of telecom applications. * For more information on Raychem Circuit Protection SiBar thyristor surge protectors. Agency Specification/Selection Guide for FT600 Devices Use the guide below to select FT600 devices appropriate for use in your application. The following pages contain specifications for part numbers recommended below. FT600 devices enable telecommunication equipment to meet the applicable protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics. Users should independently evaluate the suitability of, and test each product for their application. Family Product Lightning Power Cross FT600 FT600-0500 TIA-968-A (formerly FCC Part 68) - Type A & B UL60950, 3rd Ed. - 600VAC, 40A FT600-1250 FT600-2000 Telcordia GR-1089 - Level 1 and 2 TIA-968-A Telcordia GR-1089 - 600 VAC, 40A UL60950 Note: FT600-1250 and FT600-2000 are designed to assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended. The FT600-0500, FT600-1250 and FT600-2000 are designed to meet the UL60950 Power Cross and FCC TIA-968-A 68 lightning surge requirements. Note that Type A tests allow for an overcurrent protection component to fuse open during the surge. Interrupt Voltage and Current Ratings for FT600 Devices Part Typical I2t (A2S)* Ampere Rating (A) Voltage Rating (V) Typical Resistance () FT600-0500 0.50 250 0.5 1 FT600-1250 1.25 250 0.1 16 FT600-2000 2.00 250 0.05 18 Number The FT600-xxxx devices are designed to carry 100% of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 120 seconds maximum. Resistance measured at 10% of rated current. *I2t is calculated at 10 ms or less. 12 Figure FT1 - Thermal Derating Curve (Normalized) for FT600 Devices 130 % of Current Rating 120 110 100 90 80 70 -70 -50 -30 -10 10 30 50 70 90 110 130 Ambient Temperature C 86 Figure FT2 - Dimension Figures for FT600 Devices Figure FT2 - Product Dimensions A C B Table FT1 - Dimensions for FT600 Devices in Millimeters (Inches) Part Number Dimension A Min. FT600-0500 -- FT600-1250 -- FT600-2000 -- B C Max. Min. Max. Min. Max. Figure 10.5 (0.413) 10.5 (0.413) 10.5 (0.413) -- 3.4 (0.133) 3.4 (0.133) 3.4 (0.133) -- 3.4 (0.133) 3.4 (0.133) 3.4 (0.133) FT2 -- -- -- -- FT2 FT2 Figure FT3 - Typical Time-to-open Characteristics (at 20C) for FT600 Devices FT600 Figure FT3 A B 2A 100 1.25A B = FT600-1250 .500A A = FT600-0500 C = FT600-2000 12 TIME IN SECONDS 10 C 1 0.1 0.01 0.001 0.1 1 10 CURRENT IN AMPERES 87 100 1000 FT600 Physical Characteristics Terminal material Silver-plated brass* Body material Ceramic Termination solderability Per IEC-60127-4 *FT600 devices use high Pb content solder for internal construction. They are RoHS compliant. Telecom Fuses Table FT2 - Physical Characteristics and Environmental Specifications for FT600 Devices* Environmental Specifications Test Conditions Solder heat withstand Per MIL-STD-202, Method 210, Test Condition J Solvent resistance Per MIL-STD-202F, Method 215J Storage temperature -40/+85C Storage humidity Per MIL-STD-202F, Method 106F * FT600 devices use high Pb content solder for internal construction. They are RoHS compliant. Table FT3 - Packaging and Marking Information for FT600 Devices Part Number Bag Quantity Tape & Reel Quantity Standard Package Part Marking Agency Recognition FT600-0500-2 FT600-1250-2 FT600-2000-2 -- -- -- 2,500 2,500 2,500 10,000 10,000 10,000 500 1250 2000 UL, CSA UL, CSA UL, CSA Notes: The -2 designates tape and reel, the package style for this product. Table FT4 - Recommended Pad Layouts for FT600 Devices in millimeters (inches) Nominal Device A B C D FT600-0500 12.6 4.0 3.7 5.2 (0.496) (0.157) (0.145) 0.204 FT600-1250 12.6 4.0 3.7 5.2 (0.496) (0.157) (0.145) 0.204 12.6 4.0 3.7 5.2 (0.496) (0.157) (0.145) 0.204 FT600-2000 Figures for Dimensions Figure FT4 4 D C 4 B 4 A Solder Reflow and Rework Recommendations for FT600 Devices Solder Reflow: Figure FT5 * Recommended reflow methods: IR, vapor phase oven, hot air oven * Devices can be cleaned using standard industry methods and solvents * If a device is removed from the board, it should be discarded and replaced by a new device Preheating Soldering Cooling 250 Temperature (C) Rework: 300 200 12 150 100 50 0 120 30 to 90 10 to 20 Time(s) 88 Part Numbering System for FT600 Devices FT 600 -1250 -2 Packaging -2 :Tape & reel Current in Amperes 1250=1.25 0500=0.500 2000=2.00 Voltage Rating Product Family WARNING: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics' only obligations are those in the Company's Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make changes without notification to Buyer--to materials or processing that do not affect compliance with any applicable specification. 12 89