DPS-24HB
Input
Voltage Range 90~264Vac Auto Range
Frequency 47~63Hz
Efficiency The average efficiency at 25%, 50%, 75% and
100% load 86.21%
Input Current 100Vac /12V/2A load 2A
240Vac / 12V/2A load 1A
Output 12V 0A ~ 2A
Protection
Over-current Auto Recovery
Over-temperature Auto Recovery
Short Auto Recovery
Over-voltage Auto Recovery
Environment
Operating Temp. 0 to 40
(Refer the Power de-rating curve)
The PSU should turn on at -30
Storage Temp. -20 to 70
Operating Humidity 20% - 85%
Storage Humidity 5% - 95%
FEATURES
Total Power 24W,peak 38.4W for 4Sec.
90-264Vac Auto Range Input
EfficiencyMeet DoE level
High Reliability:>100,000 Hours @ 25
,100Vac/80% maximum load
ProtectionShort / Over-current / Over-voltage
/Over-temperature
SafetyCCC/CB/FCC/UL/BSMI
EMICLASS B
39.6 (W) x 38.7 (H) x 85.5 (L) mm
The de-rating curve of ambient temperature shown as Fig.1.
Fig.1 Power de-rating curve of Ambient temperature
Size(L x W x H) 85.5*39.6*38.7mm
AC Input Connector China integrated plug
DC Output Connector TUNING FORK PLUG(2.1*5.5)