TRON(R) In-Line Fuse Holders HEB Series Single-Pole Breakaway & Non-Breakway for 1332 x 1 12 Fuses Specification Data - Non-Breakaway & Loadside Breakaway Conductor Terminals Stranded Agency Information: (1)UL Recognized, Guide IZLT2, File E14853 (2)CSA Certified, Class 6225-01, File 47235 (3)CE Coupling Nut Torque: 10-20lb-in. Part Number Explanation Example: HEB-AK * HEB = Holder series * A = Loadside terminal (copper crimp for #12 solid copper wire) * K = Lineside terminal (copper setscrew for two #6 solid copper wires) Part Number Selection From the table on page three, select the combination of desired loadside and lineside terminals for the application (define terminal type, wire size, number of wires per terminal and whether the terminal accepts solid and/or stranded conductors). Then in the right hand two columns, select either the non-breakaway or breakaway holder part number to order. Available Part Numbers HEB-AA(1) (2) (3), HEB-AB(2), HEB-AC(2), HEB-AD(2), HEB-AE(2), HEB-AJ, HEB-AK, HEB-AL, HEB-AR, HEB-AY, HEB-BA(2), HEB-BB(2), HEB-BC(2), HEB-BD(2), HEB-CC(2), HEB-DD(2), HEB-JJ, HEB-JK, HEB-JL, HEB-JY, HEB-LL, HEB-NN, HEB-PP(2), HEB-QQ(2), HEB-RR(2), HEB-SS, HEB-TT(2), HEB-ZA. Copper Crimp #12 to #8 #12 #10 #6 #8 #4 #6 #2 #4 #20 to #18 1 2 2 1 2 1 2 1 2 1 * * * * * -- * -- * * * * * * * * * * * * #12 to #3 1 * * J #12 to #3 2 * * K #8 to #12 1 * -- #10 to #4 1 -- * #8 #6 #6 #4 #3, #4 #2 #1, #2 #1/0 1 1 1 1 1 1 1 1 -- * -- * -- * -- -- * -- * -- * -- * * #12 to #2 1 * * L #12 to #2 2 * * Y B C D E Z Solid Copper Terminal for Aluminum Wire Connector S Aluminum Crimp N P Q R T Aluminum Setscrew *Amp rating limited by conductor size. BU-SB08489 A Copper Setscrew Insulating Boots For insulating boots, see page 2. Insulating boots are not included with non-breakaway holders and must be ordered separately. They come standard with the breakaway holders. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. 0908 Catalog Symbol Load & Line (2) & (3) Solid Non-Breakaway Fuse Holders See page 2 for breakaway holders Catalog Symbol: HEB Description: Water resistant, single-pole non-breakaway in-line fuse holders for 1332 x 1 12 midget fuses. Typical fuse types: BAF, DCM, FNM, FNQ and KTK. Ratings: Volts: 600V (or less) Amps: Up to 30A* Conductor Data Size No. Per Terminal Terminal Type Page 1 of 3 Data Sheet 2127 Agency Information: (1)UL Recognized, Guide IZLT2, File E14853 (2)CSA Certified, Class 6225-01, File 47235 (3)CE Coupling Nut Torque: 10-20lb-in. Part Number Explanation Example: HEB-AW-RYC * HEB = Holder series * AW = Loadside terminal (copper crimp for #12 solid copper wire) * RYC = Lineside terminal (copper setscrew for two #6 solid copper wires) Part Number Selection From the table on page three, select the combination of desired loadside and lineside terminals for the application (define terminal type, wire size, number of wires per terminal and whether the terminal accepts solid and/or stranded conductors). Then in the right hand two columns, select either the non-breakaway or breakaway holder part number to order. Available Part Numbers Breakaway Units: (Includes fuse holder, breakaway part and insulating boots): HEB-AW-RLA, HEB-AW-RLC-A(1) (2) (3), HEB-AW-RLC-B, HEB-AW-RLC-C, HEB-AW-RLC-J, HEB-AW-RYA, HEB-AW-RYC, HEB-BW-RLC-A, HEB-BW-RLC-B, HEB-BW-RYC, HEB-JW-RLC-J, HEB-JW-RYC, HEB-KW-RLC-J, HEB-KW-RYC, HEB-LW-RLA, HEB-LW-RLC-J, HEB-LW-RYA Fuse Holder Only: HEB-AW(2), HEB-BW(2), HEB-DW(2), HEB-JW, HEB-LW Breakaway Part: RLC-A, RLC-B, RLC-C, RLC-J, RYC, RLA, RYA Specification Data - Lineside Breakaway Copper Crimp Conductor Data Size BU-SB08489 Catalog Symbol #12 to #8 1 * * -RLC-A #6 1 * * -RLC-B #4 1 * * -RLC-C #12 to #2 1 * * -RLC-J #12 to #2 2 * * -RYC #12 to #2 1 * * -RLA #12 to #2 2 * * -RYA Copper Setscrew Aluminum Setscrew Solid Breakaway (Required with Breakaway Receptacle) W Insulating Boots Part Numbers Type 2A0660 Single conductor 2A0661 Two conductor Two insulating boots come standard with the breakaway holders (example: HEB-AW-RLC-A). The insulating boots are not included with the non-breakaway holders (example: HEB-AA) or the individual pieces of the breakaway holders (example: HEB-AW, RCL-A). Two insulating boots must be ordered for each holder when ordering them separately. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. *Amp rating limited by conductor size. 0908 Solid Terminal Type Stranded Breakaway Receptacles No. Per Terminal Breakaway Fuse Holders Catalog Symbol: HEB Description: Single-pole breakaway in-line fuse holders for 1332 x 1 12 midget fuses. Typical fuse types: BAF, DCM, FNM, FNQ AND KTK. Ratings: Volts: 600V (or less) Amps: Up to 30A* Page 2 of 3 Data Sheet 2127 For HEB Holders Only Directions:To select complete holder P/N, work from left to right starting with loadside terminal options and then lineside terminal options. Then determine breakaway or non-breakaway style. Lineside Terminal Loadside Terminal Terminal Type Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp No. of Terminal Wire Size Wires per Solid Stranded Wire Wire Type Terminal #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #6 #10 #6 #10 #6 #10 #6 #10 #4 #8 #2 #6 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y #20, #18 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #2 1 Y Y #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N #1, #2 1 N Y 1/0 1 N Y 1 Y N 1 N Y SolidTerminal #8 to #12 for aluminum connector #10 to #14 (1)UL Recognized, Guide IZLT2, File E14853 (2)CSA Certified, Class 6225-01, File 47235 (3)CE (4)HEB-AW-RLC-C is for (1) #4 stranded wire only. Copper Crimp Copper Crimp Copper Crimp (4) Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Available P/N's No. of Wire Size Wires per Solid Stranded Wire Terminal Wire #12 to #8 #12 #6 #10 #4 #8 #2 #6 2/0 #3 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N N Y Y Y Y Y Y Y Y Y Y #12 to #3 1 Y #12 to #3 2 #12 to #2 Non-Breakaway P/N (Boots not included) Breakaway P/N (Boots included) HEB-AA(1)(2) (3) HEB-AW-RLC-A(1)(2) (3) HEB-AB(2) HEB-AW-RLC-B HEB-AC(2) HEB-AW-RLC-C(4) HEB-AD(2) N/A HEB-AE(2) N/A Y HEB-AJ HEB-AW-RLC-J Y Y HEB-AK HEB-AW-RYC 1 Y Y HEB-AL HEB-AW-RLA #12 to #2 2 Y Y HEB-AY HEB-AW-RYA #1, #2 1 N Y HEB-AR N/A #12 to #8 #12 #6 #10 #4 #8 #2 #6 #4 #8 #2 #6 #12 to #8 #12 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y HEB-BA(2) HEB-BW-RLC-A HEB-BB(2) HEB-BW-RLC-B HEB-BC(2) N/A HEB-BD(2) N/A HEB-CC(2) N/A HEB-DD(2) N/A HEB-ZA N/A #12 to #3 1 Y Y HEB-JJ HEB-JW-RLC-J #12 to #3 2 Y Y HEB-JK HEB-JW-RYC #12 to #2 1 Y Y HEB-JL N/A #12 to #2 2 Y Y HEB-JY N/A #12 to #2 1 Y Y HEB-LL HEB-LW-RLA #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N HEB-NN N/A HEB-PP(2) N/A HEB-QQ(2) N/A #1, #2 1 N Y HEB-RR(2) N/A 1/0 1 N Y HEB-TT(2) N/A 1 Y N 1 N Y HEB-SS N/A SolidTerminal #8 to #12 for aluminum connector #10 to #14 Contact your local Cooper Bussmann representative for other possible terminations not listed. The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. (c) 2008 Cooper Bussmann St. Louis, MO 63178 636-394-2877 w w w. c o o p e r b u s s m a n n . c o m 0908 BU-SB08489 Page 3 of 3 Data Sheet 2127