Receiver for Digital Signals Types G 3430 1149, G 3430 2249, G 3430 4443 Du line (R) Fieldbus Installationbus * 1-, 2- or 4-channel receiver * Galvanically separated SPDT or SPST relay outputs * Load: 1 x 10 A/250 VAC 2 x 10 A/250 VAC 4 x 5 A/250 VAC * H4-housing * For mounting on DIN-rail (EN 50022) * LED-indications for supply, outputs and Dupline(R) carrier * AC or DC power supply * Channel coding by GAP 1605 (see the data sheet on GAP 1605 for details) Ordering Key Product Description G 3430 4443 024 VAC/10 A or SPST relay outputs for control of 4 loads of up to 250 VAC/5 A. Type: Dupline H4-housing Receiver No. of channels Output type Power supply Supply Ordering no. 1 channel 10 A/250 VAC Ordering no. 2 channels 10 A/250 VAC Ordering no. 4 channels 5 A/250 VAC 24 VAC 115 VAC 230 VAC G 3430 1149 024 G 3430 1149 115 G 3430 1149 230 G 3430 2249 024 G 3430 2249 115 G 3430 2249 230 G 3430 4443 024 G 3430 4443 115 G 3430 4443 230 10 to 30 VDC 15 to 30 VDC G 3430 1149 800 G 3430 2249 824 G 3430 4443 824 (R) Dupline receiver. SPDT relay outputs for control of 1or 2 loads of up to 250 (R) Type Selection Output Specifications Outputs Isolated in groups of Contact ratings (AgCdO) Resistive loads AC 1 DC 1 or Inductive loads AC 15 DC 13 Mechanical lifetime Electrical lifetime (at max load) AC 1 Operating frequency Dielectric voltage Outputs - Dupline(R) Response time G 3430 1149 ... (1 channel) 1 SPDT relay 1x1 (micro gap) 10 A/250 VAC (2500 VA) 1 A/250 VDC (250 W) 10 A/25 VDC (250 W) 2.5 A/230 VAC 5 A/24 VDC 30 x 106 operations G 3430 2249 ... (2 channels) 2 SPDT relays 2x1 (micro gap) 10 A/250 VAC (2500 VA) 1 A/250 VDC (250 W) 10 A/25 VDC (250 W) 2.5 A/230 VAC 5 A/24 VDC 30 x 106 operations G 3430 4443 ... (4 channels) 4 SPST relays 4x1 (micro gap) 5 A/250 VAC (1250 VA) 0.25 A/250 VDC (62 W) 5 A/25 VDC (125 W) 2.5 A/230 VAC 5 A/24 VDC 30 x 106 operations 2.5 x 105 operations 7200 operations/h 2.5 x 105 operations 7200 operations/h 2.0 x 106 operations 7200 operations/h 4 kVAC (rms) 1 pulse train 4 kVAC (rms) 1 pulse train 4 kVAC (rms) 1 pulse train Specifications are subject to change without notice (28.09.99) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 1 Du line G 3430 1149, G 3430 2249, G 3430 4443 (R) Fieldbus Installationbus Supply Specifications Power supply Overvoltage cat. III (IEC 60664) Rated operational voltage through term. 21 & 22 230 230 VAC 15% (IEC 60038) 115 115 VAC 15% (IEC 60038) 024 24 VAC 15% Frequency 45 to 65 Hz Voltage interruption 40 ms Rated operational power G 3430 1149 024/115/230 Typ. 3.5 VA G 3430 2249 024/115/230 Typ. 4.5 VA G 3430 4443 024/115/230 Typ. 3.5 VA Power dissipation G 3430 1149 024/115/230 6.5 W G 3430 2249 024/115/230 8W G 3430 4443 024/115/230 8W Rated impulse withstand voltage 230 4 kV 115 2.5 kV 024 800 V Dielectric voltage Supply - Dupline(R) 4 kVAC (rms) Supply - Outputs 4 kVAC (rms) Power supply DC types Operational voltage through term. 21 & 22 800 824 Ripple Reverse-polarity protection Rated operational current G 3430 1149 800 G 3430 2249 824 G 3430 4443 824 Power dissipation G 3430 1149 800 G 3430 2249 824 G 3430 4443 824 Inrush current Rated impulse withstand voltage Dielectric voltage Supply - Dupline Supply - Outputs General Specifications Mode of Operation Output OFF delay Upon loss of Dupline carrier Power ON delay Power OFF delay Indication for Supply ON Output ON Dupline(R) carrier Environment Degree of protection Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Material (see Technical informations) Weight G 3430 1149, G 3430 2249 G 3430 4443 1-channel receiver with change-over contact output 20 ms Typ. 2 s 1s The output is coded by means of the code programmer GAP 1605. LED, green LED, red (one per output) LED, yellow IP 20 3 (IEC 60664) -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 20 to 80% 15 G (11 ms) 2 G (6 to 55 Hz) The output is normally OFF. When a transmitter coded to the selected channel is activated, the output turns on and remains on until the respective channel becomes deactivated. The default setting is such that upon loss of Dupline(R) carrier the output goes off. 2-channel receiver with two change-over contact outputs Overvoltage cat. III (IEC 60664) 10 to 30 VDC (ripple included) 15 to 30 VDC (ripple included) 3V Yes 150 mA 150 mA 100 mA 5.5 W 5.5 W 6W 1A 800 V 200 VAC (rms) 4 kVAC (rms) When a transmitter coded to the selected channel is activated, the output turns on and remains on until the respective channel becomes deactivated. The default setting of the module is such that upon loss of Dupline(R) carrier all outputs go off. 4-channel receiver with four normally open contact outputs Each output may be coded individually by means of the code programmer GAP 1605. The default setting of the module is such that upon loss of Dupline(R) carrier all outputs go off. H4-housing 250 g 300 g Each output may be coded individually by means of the code programmer GAP 1605. The outputs are normally off. For changing the default setting, please refer to the datasheet on GAP 1605. Operation Diagram Power supply Dupline(R) carrier Transmission on channel 1 Output 1 Transmission on channel 2 Output 2 2 Specifications are subject to change without notice (30.04.03) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group Du line G 3430 1149, G 3430 2249, G 3430 4443 (R) Fieldbus Installationbus Wiring Diagrams 1 channel G 3430 1149 AC (DC) supply S: Signal wire 2 channels G 3430 2249 AC (DC) supply (+) (-) Output Power supply S: Signal wire (+) (-) OutPower put 1 supply Output 2 Accessories 4 channels G 3430 4443 AC (DC) supply DIN-rail FMD 411 For further information, see "Accessories". Out Out 3 4 Out Out 1 2 S: Signal wire (+) (-) Power supply Specifications are subject to change without notice (28.09.99) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 3