First Edition MARTE RR LCD Module Technical Specification Sep.30, 2008 Wi ta FAR EV 2 EERE Final Revision 487 KRKKKKK TyeN. =- T-5343GD035JU-LW-ADN Customer - OPTREX STANDARD / APRKLYYIR RZSBVAFE Customer's Product No: ---------- OPTREX CORPORATION Yasuo Kawasaki Approved: QUALITY ASSURANCE DIVISION Noboru Wada Checked: Module Design G,. Takashi Yuchi Prepared: Project Management Div. APPROVED By Signature : Date : Please return this specification within two month with your signature. If not returned within two month, specification will be considered as having been accepted. SCfARI CFF EL, 2008 4F 11A 28H ECC, META AE COIRHIX REV, TIRANREBAL, MER HOL UCTHY ARV WEF AA CTRA ET, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 1/33 OPTREX ConfidentialTable of Contents (Hx) 1. Application Gi FR) ccc cccccccescescessessessessessssessessessessessessestssesseasasestessestessessessestestessestes 3 2. General Specifications (HR(LR) oo cceccscescessessessescessessestestessessessessestessestessestestestessentess 3 3. Operating Conditions (FREES) cece ceccecccccecescescescestestestcstestestesteseestestcatestessestestestesseaes 4 4. Dimensinal Outline (SED) occ cccccccesecsesenecsssesecsssesececsesecessesecsssesecesseesesseneessseeeeeees 5 5. Block Diagram (7 7 AA SPD ID) occccccccccecccccsesccessesecesesccssesecsseseessessenssetensseneeees 6 6. WO Terminal (1 / OSS) coicccccccceccccccsssescesccsesesccsesesecsesesecssseseesesesesaseseeescstseasenteeseetees 7 7. Electrical Specifications (AE UAIBRME) occ ccceccccceesccseseseceesescesessecseseaeesasestesssesteaseseeees 9 8. Optical Specifications (ESTEE) ooo ccececccccccccescescescescestessestestessestestestestessestestestestestentes 19 Q. Test GRBR) ec ccccccceccsesecsesenecssseecsesesecscsesecsssesasaesesesseseessssecessesecessssecesseecesseteeesaeees 25 10. Appearance Standards (SMELEUES) oo cccccccecescessessessessessessestessessessestestessessessestessestestess 26 11. Code System of Production Lot (E% 1 yy BA) ccc ccccsccseecsecseeeeetseceenseeeenseestens 29 12. Type Number (82 tne) ccc ecescescescessessestessessessessessesseusessessaseasestessesseatessestesseatestess 29 13. Applying Precautions (38 FUE OYE) occ ccccccccccccescesesesccseeeseceseseeeesesteaseseeseetenseentees 29 14. Precautions Relating Product Handling (cu ERGY. LOPE) eee eeeeeeeeeerees 30 15. Warranty (FRAEARTE) ieee ccccceccescescessessessessescessessessessessessessesseasessessestestestessessessestessestestess 33 Revision History (GtiTE) Rev.(2ci) | Date(czxZH) | Page(~*)| Comment(N) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 2/33 OPTREX Confidential1.Application (iti A ) This specification applies to TFT-LCD module (T-55343GD035JU-LW-ADN),. MiRREL, AT hy 7 ARDS TS TFT-LCD - Y 2 (im : T-55343GD035JU-LW-ADN) (Zi JAS. 2.General Specifications ( fk tt) Screen Size : 3.5 inches (1 -)(8.9cm) Diagonal(xt #4) (ET) Active Area > 70.08(W) x 52.56(H) mm (Ae TA) Display Format > 320(W) x 3[R.G.B] x 240(H) (ial 38 BO) Pixel Size > 0.073 x 3[R.G.B](W) x 0.219(H) mm (HIS 4 A) Pixel Arrangement : RGB-Stripe(RGB 4 k 7-7 7) (i389!) Color Depth : 16M colors (2.20) Display Mode : Normally White? -~ J -& 7 b) (RAE BP) Viewing Direction : 12 O'clock (1 Angle of Least Color Inversion) Give) Surface Treatment : AG Coating (#e LER) Interface : 24-bit Digital RGB interface(8-bit / color) (AvaA-7 aA) (24 Ey he Ye RGBA YF - 7 ae ANB Ey bf) Outline Dimension > 79.0(W) x 65.0(H) x 3.2Max*(D) mm OME TY) *Without FPC and Component Area(FPC & 322# 7 ih &BR< ) Weight (Gi) : 29.5gmax Backlight(f@54(t#8) : LED Backlight/ White (LED 7 777 h/Af) RoHS regulation : To our best knowledge, this product satisfies material (RoHS #172) requirement of RoHS regulation. Our company is doing the best efforts to obtain the equivalent certificate from our suppliers. FEO RAT S BEY (BSC, AAI RoHS HED ERE WTS CWS ba LE THO ET, MALE UTIL, BMT A A FIC HL CRO PRAE ROO KKIROB AITO THIET, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 3/33 OPTREX Confidential3.Operating Conditions (8 be & (# ) Item Conditions Temperature Range Remark (AB) (ALF) (dint. BE 80, E#]) (hii) Operating Temperature Range PNL Surface _ cee -_ -20~70C Note1 (i 1) (Sh Fit HERG A) US-# #8) Storage Temperature Range PNL Surface 30~80C (PTFE a A) SAR) Note1: Operating temperature range defines the operation only and the contrast, response time and other display optical characteristics are set at Ta=+25C. E1: D/P MEO, VFO ARERAET ChE CHO, ALY RIA, WSR, SOMO Zorn ihe, SETA PEREIE Ta=+25C IC CHE LEV. T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 4/33 OPTREX Confidential4.Dimensinal Outline (5% 2) 80/r0/s00% Uo panss| FNOLLOSMIG ONIMGLA ZHi JO LON SHI C30qv avd NAVUC SNOIS TARY BNSS 1 | ev VIAY AV LYON oueg iso es 2OLF gt ol? STONY ARE ORO 3ZzIS 9nd Nosq NAVEL VF [Bor oes asva cveresg-1 [40.0810 Siva] yonqoziy ihys OLISFASLOVAYHO BY IMOT Lad (lr OLYCND TIVL 40 \et [21 | Sy 0F [00ss Dosz (3000)0N 9Mo) ULL | rt qos! -S QUIOMINOD JNV () RIV JH! HII SNOISNNIG HI Teor 6 pF loses be NINO TwNoIsNawia LLINO [3 1v9s] owexo prniusoL SSTON a|o gM | S0F | 20F | S95 Pot fu | p rotate 0 NOMUVGOTIOD XTAMO| youosie a10 2a A SSS HSIN S| : LYA Tl G)IND TIVlaG yaa 2) Vo |i Zila mm O 2 78d Sz ae N91 +2 salen gaalee Zo 68a [ez a oLaale2 = Lad oz a ZLaG|l craayat ee ee praaret eae V/ SLealar og (FOLD Q9Alor] GNOISL 0Z9 LHOIH_INaNOdNOD ae : S5Aleo) SL aalrL (Sagas ge (S3}8S 8609007 XVAS | S0e | (se'6a) GNS se} Zag eh LNO or Va ZNO LNO ods Ze) erealat J - H Lasaulec) 61 Sd[it Nf a aaOL Ws Lovince~ 1B a a os |ve) 1 80le Pa nana ek ay INGNOdNOD rasi) 2eaals Lt (OI eS > ogdlzc| zadi7 LAGILe) JTWNa/9 Zaq TOS) ONASHIS on CaG)6Z) ONASA|Y q r raaec) sLoa|s en l[tio saa s ailz oe ggg}9z ValL ey Im TORWASTON| TOGAISTON acs INSANDISSY Nid y pS t S100 OF2x(AD'NIOZE = J pod Se (oT 6ES CW7VIEO OZ (OF PI (WFAN SL Tos 80.01. YW) ONYS 'S INO 40 INGANOISSY Nid SHL GZ0NVH3 Y vor) 68 "MOLOSNNOD LNO FHL 319a4Y09 (Z] NQISUTANL [SV31_J0 TONY
) Functional Description (#& #E gt A) 1 RL Input to select Source driver Datashift direction (PAB PAN FHA YT BGR) 2 TB Input to select Gate driver Datashift direction (FOR BIAN-AR YU YT b ATER) 3 DOTCLK Clock Signal (Fy h7 2 7 fae) 4 VSYNC Vertical Sync Input (EEL HAfS-s) 5 HSYNC Horizontal Sync Input (7 {IRIE S) 6 ENABLE Input Data Enable Control (4 *7 Vlas) 7 DB23 Data Signal Graphic Display Data Red-data (MSB) 7 fe : RL ALE y b) 8 DB22 Data Signal Graphic Display Data Red-data (87 4 fa 5) 9 DB21 Data Signal Graphic Display Data Red-data (87 4 fa 5) 10 DB20 Data Signal Graphic Display Data Red-data (ak 4 {2 5) 11 DB19 Data Signal Graphic Display Data Red-data (ak 4 {2 5) 12 DB18 Data Signal Graphic Display Data Red-data (ak 4 {2 5) 13 DB17 Data Signal Graphic Display Data Red-data (ak 4 {2 5) 14 DB16 Data Signal Graphic Display Data Red-data (LSB) 7 # fR Ss 2 PALE y b) 15 GND Power Supply (OV, GND) (#82 (OV, GND)) 16 DB15 Data Signal Graphic Display Data Green-data (MSB) RET FBS: Fe LAL Ey b) 17 DB14 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 18 DB13 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 19 DB12 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 20 DB11 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 21 DB10 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 22 DB9 Data Signal Graphic Display Data Green-data (#7 7 [2 5) 23 DB8 Data Signal Graphic Display Data Green-data (LSB) RET FBS: Be PALE y b) 24 GND Power Supply (OV, GND) (#82 (OV, GND)) 25 DB7 Data Signal Graphic Display Data Blue-data (MSB) (B7 fas : REALE Y b) 26 DB6 Data Signal Graphic Display Data Blue-data (@7 7 (25>) 27 DB5 Data Signal Graphic Display Data Blue-data (@7 7 (25>) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 7/33 OPTREX Confidential28 DB4 Data Signal Graphic Display Data Blue-data (@7 7 (25>) 29 DB3 Data Signal Graphic Display Data Blue-data (@7 7 (25>) 30 DB2 Data Signal Graphic Display Data Blue-data (@7 7 (25>) 31 DB1 Data Signal Graphic Display Data Blue-data (@7 7 (25>) 32 DBO Data Signal Graphic Display Data Blue-data (LSB) (87 -Afas sik PLE y b) 33 SDI Serial Interface Data (VU 7 VF- 7 AN) 34 SCL Serial Interface Clock (YU 7 V7RY7AN) 35 cs Serial Interface Chip Select L:Active(>hy 7eULZ fas L: BR) 36 RESET System RESET L:Reset(!) &y Mas L: Ue hb) 37 SDO Serial Interface Data (VU 7 VF - FH) 38 GND Power Supply (OV, GND) (#82 (OV, GND)) 39 Vcc Power Supply forSystem (1 A7 AREER) 40 Vcc Power Supply forSystem (1 A7 AREER) 6.2.CN2 Pin Assignment (CN2 E 824ll) Used FPC (44 FPC) : PO.5mm, 3pin,T=0.2mm Corresponding Connector GHG 2% #) : 6298 Series (ELCO) No. | Symbol(#25>) Functional Description (#& #E gt A) 1 LEDA LED Anode Terminal (LED 7 7 Pita) 2 Nc Non Connection (Act sii) LED K LED Cathode Terminal (LED 7 Y bit) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 8/33 OPTREX Confidential7.Electrical Specifications (3B Su BY Fe PE) 7.1.Absolute Maximum Ratings (##xtmR AE) Ta=-20~70C, GND=0V Parameter Symbol Conditions Min. Max. Units (AB) (io) (Aff) (Biz) Supply Voltage VCC - -0.3 4.0 V (FAVA ABE) Input Voltage VIN GND-0.3 4.0 V (ATI FREE) 7.2.DC Characteristics(D C #t#) Ta=-20~70C, GND=0V Parameter Symbol Conditions Min. Typ. Max. Units CHA) (io) (Aff) (Biz) Supply Voltage vec - 3.0 3.3 3.6 V for System (LAF AAR) "High" Level Input Voltage ViH - 0.svcc - VCC Vv ("High" b-S7V AA BIE) "Low" Level Input Voltage Vit - 0 - 0.2vCC Vv ("Low" b-S7L ATi #4) High Level Output Voltage VoH - 0.9VCC - vec V ("High" SL HABE) Low Level Output Voltage VoL - 0 - 0.1VCC V ("Low" b UV HA BE) Opeating mode Current ICC VCC-GND=3.3V - 11.0 16.5 mA (FU TTC) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 9/33 OPTREX Confidential7.3.AC Characteristics(A C ##14) 7.3.1.Serial Interface Timing Characteristics (YU VIL VA-Dr-ABA BVA) Ta=-20~70C, GND=0V Parameter Symbol Min. Typ. Max. Units CHE) (at) (BAZ) Serial Clock Cycle Time tclk 50 - - ns (VU NVIAYIHA ZIV) Clock Low Width tsl 25 - - ns (LUFT VIA YZ LAVA) Clock High Width tsh 25 - - ns (LUT UIA YT HAVA) Clock Rising Time trs - - 30 ns (VUF NZ By 7b EDS 0 SA) Clock falling Time tfl - - 30 ns (LUT V7 Ay 7 AEF YO Rd) Chip Select Setup Time tcss 0 - - ns (Fv StU bey hY vy TREE) Chip Select Hold Time tcsh 10 - - ns (Fv TeveZ bAV PRA) Chip Select High Delay Time tcsd 20 - - ns (Fv Pt b HveRER TA) Data Setup Time (7-7 & vy bY WRF) tds 5 - - ns Data Hold Time (7 7 #V BASIN) tdh 10 - - ns tess tesh cs /| csd telk is tsh tts gig SCL [| 2 Q00C/ tds tdh T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 10/33 OPTREX Confidential(FLAVMRGBA YAOI er AAT 7.3.2.Digital RGB Interface Timing Characteristics Rv TREE) Ta=-30~85C, GND=0V Parameter Symbo Min. Typ. Max. Units GA A) (i) (H fiz) DOTCLK Frequency (7 2 7 JARO footeik - 6.5 10 MHz DOTCLK Cycle Time (7 By 7-4 7 LI) | tooterk 100 154 - ns Vertical Sync Setup Time tvsys 20 - - ns (VSYNC 2 y BY y RFID) Vertical Sync Hold Time tvsyH 20 - - ns (VSYNC 7 ESTED) Horizontal Sync Setup Time tusys 20 - - ns (HSYNC yy bY FERFTAD) Horizontal Sync Hold Time tusyH 20 - - ns (HSYNC xh7- RIERA) Phase difference of Sync Signal Falling Edge tuv 1 - 240 | tootcik (SYNC {3 75Az F 9 ict #2) DOTCLK Low Width (7 2 7 L7\yv Allis) text 50 - - ns DOTCLK High Width (7 2 7 Ls Alf) tox 50 - - ns Data Setup Time (7-4 & y bY y WR) tos 12 - - ns Data Hold Time (7 # WV BIRFFAD) tox 12 - - ns . tvsys VSYNC Na _ tHSYS HSYNC L tHV 5f = tboTCLK Sy tHSYH f +> yl DOTCLK /) Kt ~ tCKL tCKH DBO~DB23 x {Ds | {DH T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 11/33 OPTREX Confidential7.3.3.Data Transaction Timing in Parallel RGB Interface (SYNC Mode) (NFUVRGBF#MEY 4 SY) (SYNC *E F) Heycle = 408 tHBP = 68 toisp = 320 tHFP = 20 sos F{ALPLT AULT FULL -SIUNINL HSYNC i | 317(318|319 a) Horizontal Data Transaction Timing Veycle = 262Lines tvap = 18 > I r VSYNC Voisp = 240Lines | tvpP=4 ~~ TN Wr Line 0 Line 239 4 yy a v b) Vertical Data Transaction Timing 7.3.4.Data Transaction Timing inParallel RGB Interface (ENABLE Mode) (ANF UVRGBF FMLA 4 327) (ENABLE F) 1period (1Frame) Dummy Enable 240H (3H) > 2H pig it core TU DBO~DB23 1Horizontal Period 320 dotclk 31~80 dotclk DOTCLK ENABLE DBO~DB23 =|D0}D1 | D2 Valid Data Transfer Area T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 12/33 OPTREX Confidential7.3.5.Reset Timing Characteristics (Jy KAAS EY) Ta=-20~70C, GND=0V Parameter Symbol Min. Typ. Max. Units (AB) (iy) (HAZ) Reset "L Pulse Width() @ RL?7S/v Zl) trw 10 - - Ls RESET Vi \ VIL IL tRES 7.4.Power ON Sequence (JR ON Y7 YR) 7.4.1.Data Transfer of SPI (SPI 74 #R34) Trancfer starts Trancfer Ends oc [\ JT 123 465 6 7 8 1011 12 13 14 15 16 17 18 19 20 21 22 23 24 pERBEBEBOREREERREE Device ID 7.4.2.Power ON Procedure (Recommended Sequence) VCC Power ON (VCC 33380 N) (FEE ON IIR: HELE 7 X) | Wait 10usec~ (10sec LA_Ef #3) ue S/ 210us 1 RESET Release RESET (J ty b #EBR) TE ets | SPI : SPI Accessing x Input Control Signal SPI Command sequence (Refer to 7.4.3.) (HIZB AT) DOTCLK (DOTCLK/HSYNC/VSYNC) ) HSYNC Execute SPI Command Setting Suc ss ene VA A vee 1ST | 4TH aa Input Black data Deos | Black Pattern Normal Pattern (B- A AF) J LCD Display ON after 11 frames (VSYNC 11 7 b- A%% LCD FRET) > Display ON T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 13/33 OPTREX Confidential7.4.3.Command List for Power ON (Recommended Setting) (BRON ROIVL FR: HEY TY -Z) Setting Item | Index | Value Driver Output 0001 h 6300 h LCD Driver AC Control 0002 h 0200 h Power Control (1) 0003 h 6064 h Data and Color Filter Control 0004 h 0447 h Function Control 0005 h B084 h Contrast/ Brightness Control QO0A h 4008 h Frame Cycle Control OQOOB h D400 h Power Control (2) O0O00D h 423D h Power Control (3) OOOE h 3140 h Gate Scan Starting Position OOOF h 0000 h Horizontal Porch 0016 h 9F80 h Virtical Porch 0017 h 2212h Power Control (4) 001E h OODB h Gamma Control 1 0030 h 0000 h Gamma Control 2 0031 h 0607 h Gamma Control 3 0032 h 0006 h Gamma Control 4 0033 h 0307 h Gamma Control 5 0034 h 0107 h Gamma Control 6 0035 h 0001 h Gamma Control 7 0036 h 0707 h Gamma Control 8 0037 h 0703 h Gamma Control 9 003A h 0CO00 h Gamma Control 10 003B h 0006 h T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 14/33 OPTREX ConfidentialD 7.4.4.Color Data Assignment (H3F4 AER) 8-bit / color COLOR R DATA G DATA B DATA INPUT _|msB(DB23) LSB(DB16) MSB(DB15) LSB(DB8) MSB(DB7) LSB(DBO) DB : DB? DB: DB DATA 23 | 22 $21 | 20 DB 19 DB DB DB DB : DB: DB 15 14 13 DB DB DB 10 DB DB DB: DB : DB 7: 6:5 DB: DB: DB: DB DB BASIC COLOR BLACK 0:0:0:0 RED (255) |}1.1:15 1 GREEN (255) Oo Oo Oo Oo = = = = = = Oo Oo Oo Oo Oo Oo Oo Oo BLUE (255) CYAN MAGENTA YELLOW WHITE RED RED (0) RED (1) O:;0:0/7:2A:7:0:0 OrOo:riO;AiArirA:ioio O:;rO:O;/7F: A: iA io:io O:;0:;0/7:272:7A:0:0 RED (2) OPO: rO;/AirArirAioio O:;0:;0/7:272:7A:0:0 Oi: fr: O;mianeir: o:o OPO rO;AiAioirAio O:;rO:O;/7F: A: O:-:o Oro rioO;AiA:ioiAio O:;rO:O;/7F: A: O:-:o O:;0:0;/7:7:0:3>:0 O:;0:0;/7:7:0:3>:0 Oro rioO;AiA:ioiAio O:;rO:O;/7F: A: O:-:o CPi al/saioisaiaia CPi al/saioisaiaia CDi a/saio:isaiaia C:Dia/saio:isaiaia RED (254 ) RED (255) GREEN GREEN (0) GREEN (1) O:0:0] 7: Oro:o|-Ai- O:;O0:0;] 7: + O:0:0/], 7: - GREEN (2) O:;o:o|;]-i- O:0:0/], 7: - O:;o:o|;]-i- O:0:0;/ 7:0 Oro:o|o:o O:0O:0;,/0:0 O:ro:o|;O0:0 O:0O:0;,/0:0 O:0:0/,/0:0 O:0:0/,/0:0 =F1O:O|;]0O0:0 OO: j>:O;/0:0 Oro:o|o:o O:O:O0;,0:0 Oro:o|o:o O:0O:0;,/0:0 O:0O:0;,/0:0 Oro:o|o:o O:0:0/,0:0 O:0:0/,/0:0 GREEN (254) GREEN (255) BLUE BLUE (0) BLUE (1) BLUE (2) BLUE (254) BLUE (255) 2) Data [Note] (i) 1) Definition of gray scale (faa 8s Color (n) --- n indicates gray scale level. (ni _ D(820,1) D(1,1)_ => D(320,1) a wee a Lo a ? D(1,240) _<""_, D(820,240) D(1,240) <5 D(620,240) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 17/33 OPTREX Confidential7.7.Lighting Specifications (FAA LL) 7.7.1.Absolute Maximum Ratings (#&xtig Aes) Ta=25C Parameter(54 4) Symbol(#25) | Conditions(=) | Min. Typ. | Max. | Units(#ifz) Forward Current (IBS. i7i) lF Note 2 - - 35 mA Allowable Reverse Current IR - - - 50 uA CHET) LED Power Dissipation Pp - - - 0.77 WwW (GTFAGBA) Note 1 : This value is for each 1 line. GEL: (WHEY Oe RLET, ) Note 2: Refer to the forward current derating curve. (E22: 7 4L-F4vVTA-Tk Fiat, ) {Forword Current Derating Curve (Ewieiittett) ) {LED Circuit (LED [18%)) IF (mA) LEDA O+ 35 2 z ox 3 15 z z z -30 25 70 Ta(C) LEDK QO 7.7.2.Operating Characteristics (BI/F2E#%) Ta=25C Parameter(J8 A) Symbol(#25) | Conditions(A) | Min. Typ. | Max. | Units(#ifz) Forwrad Current (IS. ii6) lF Note1 - - 20 mA Forward Voltage (IBS) Ve lF=20mA / 1 line - 19.2 - V Power (#277) PL 0.39 Ww 2S EE ACEME & ToT Te Note1: Current of LED par chip must be lower than 15mA at 70 degC. The current of LED must be tuned to satisfy as Forword Current Derating Curve mentioned relationship E1 : LED JIRASiIL, 70C, 15mMA LYIK< FOVEM OES, (< LED DBC TET OM ERD th OES, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 18/33 OPTREX Confidential8.Optical Specifications (+ Att tk) 8.1.Optical Characteristic (73414) Item Symbol |Conditions(&()| Standard Value(#its{ED | Unit Vesna Remark easure (CAB) Gis) | 0 d | C | Min. Typ. | Max. | (HEIZ) | gaygeysy| Cis) (1)Brightness(# 2) B o | O - 400 Cd/m? Note1 Optimum vas Viewing Angle (2)Contrast(2/ bh 74h) CR Sas 400 700 - - CO Rx o | O 0.58 0.63 0.68 - Red Ry o | O 0.31 0.36 0.41 - Fig.1 Gx | o | o 030 | 035 | o40 | - | *'9? (3)Color Green Gy o | O 0.55 0.60 0.65 - Coordinates Bx o | O 0.10 0.15 0.20 - (25) Blue By o | O 0.05 0.10 0.15 - Wx o | O 0.28 0.33 0.38 - White Wy o | O 0.30 0.35 0.40 - (4)Brightness Uniformity) = - o | O 70 - - % _ (Fig.2) (HERE AZ) (5)Vertical Up Qu - | 0 | 55 - 80 - |Degree Viewing Angle (EECHLEF HA) Down] 8p - 0 25 - 80 - Degree . (Fig.3) (6)Horizontal Let | o | oo] - | os] - 80 - |Degree Viewing Angle Ck EARLEF 8) Right or 0 - 25 - 80 - Degree (7)Response Rise w o | O - 8 - ms ; (Fig.4) Time(s SEF) |Decay|} td o | 0 - 15 - ms Note1:Under the condition of maximum brightness. (7 1:3 AUHEER HE FP) @ Conditions for Measuring Environment: Dark room with no light or close to no light. 12 O'Clock Temperature: 25+5C Humidity: 40~70%RH @ WERT Pic is 9 WEEE > WSS E TOILET SE OPE: 25+5C WEE: 40~70%RH @ Optimal viewing angle (The angle of Least Color Inversion) @ EMA (BAS belis LIC < VYATAD) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 19/33 OPTREX Confidential@ Method of Brightness Measurement (HREEVUZEYE) (Fig.1) (1) Measuring Device (if 22218) TOPCON BN-5, Measuring Field: 1 (2) Measuring Point (i i2.8) Center of Display 9=0, =0 On condition 9: A vertical angle from measuring direction to perpendicular. : Ahorizontal angle from measuring direction to perpendicular. mPa 8 =0 , @=0 Te L, 0 + TERR CRT 4 Ay HEEL HAT [A] D FH FE > TERRORS S BLS ID 7h 7 Ta] D $4 RE (3) Method of Measuring (ill 77%) Apply signal voltage (displayed in white) to maximize brightness and measure brightness B (cd/m*). The distance between BNM-5s front lens to surface panel is 500mm. Measured after backlight has been lit for more than 30 minutes. WERE DRAL ROSIE (AHR) SAIL, WEEB (cd /m*) WETS. WEHERELBMS bY Anim kONRVRMECSOOmmE UTHETS, SNYTDFA BRK 3 O47 EL EPRICE SS Center (Pixel) (X, Y)=(120,160) LCD Module Wee YI IL Distance: 500mm ipa TOPCON BM-5 T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 20/33 OPTREX Confidential@ Method of Contrast Measurement (= 2 7 X% bikie HE) (Fig.1) (1) Measuring Device (jf 2218) TOPCON BN-5, Measuring Field: 1 (2) Measuring Point (iiz.5) Center of display: same as Method of Brightness Measurement Wy Ps PRE Ee & Pala (3) Method of Measuring (i207 Hs) * Set LCD module to 0=0, o=0. (mE VY ave d=O0 . 6 =0 Key hTS, ) + Change signal voltage to measure maximum brightness Y1 and minimum brightness Y2. (Ss BEALE SH, RATHEY 1. BeIVRELY 2 ewe TS, ) > Contrast is derived from CR=Y1/Y2. (CRH=Y1/Y2e2Yh7ARETS, ) @ Definition of Brightness Uniformity GREET: 5 OTR) (Fig.2) Definition is calculated from the 5 points (SO-S4) on the diagram below. FRicaeta (SO~S4) OW EAC, FiORPRAlc CHET S, S0~S4 MIN Ge MED Standard value of Brightness Uniformity[%] = x 100 CHEBE Te > OO BLEED S0~S4 MAX GREK {IED) (15mm) (15mm) , (10mm) - S1 S4 So0 PN Active Area | + (10mm) Fig. 2 T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 21/33 OPTREX Confidential@ Method of Viewing Angle Measurement (22/2727) (Fig.3) (1) Measuring Device (i232) ELDIM EZ : CONTRAST (2) Measuring Point (lz2.4) Center of display: Same as Method of Brightness Measurement Wy Ps PRE Ee & Pala (3) Angle of Measuring (i724 EE) 8: An angle vertical to perpendicular line from the viewing direction. 6: TERPS TS HL 44 i EET TF] DD 44 FE : An angle horizontal to perpendicular from the viewing direction. D2 ERROR SB BSG A OAT [i] D FB BE (4) Method of Measuring (i772) Set the module on the rotation table and measure a vertical axis direction in the state that fixed =0 degrees horizontal axis direction to @ =90degrees. (Viewing angle is measured automatically by EZ CONTRAST). EV ave ln Ay Vicky bl, HEAT 6 = 0 . ZKEHHOT TA 2 6 = 9 0 (, RRHAER Fig. 3 T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 22/33 OPTREX Confidential@ Measuring Response Time (is iRFE] OYE) (Fig.4) (1) Measuring Device (i221) TOPCON BM-5 , Measuring Field: 1 Tektronix Digital Oscilloscope FIbA=aT ALR FYE AYAAA-T (2) Measuring Point (lz2.4) Center of display, same as Method of Brightness Measurement Wy Ps PRE Ee & Pala (3) Method of Measuring (ia 772%) Set LCD panel to0=0, and $=0. Mink Input white+blackwhite to display by switching signal voltage. APRCACRETS LICKS RELY BA CHUIITS, If the luminance is 0% and 100% immediately before the change of signal voltage, then tr is optical response time during the change from 90% to 10% immediately after rise of signal voltage, and td is optical response time during the change from 10%to 90% immediately after decay of signal voltage. fas BE OR AEA OMEeSNENOM, 1LO0O%ETSE, RAS USE DR, THAISEA 9 O%DP6 1 OWICAEF SOIC PMPSKe cr & LY RAMA BIL FRO R, HEISE 10% 9 OWE CHET SMA cd ETS, White Black White be > \<_______ 100% 90% Brightness 10% 0% _ wr < td < Fig. 4 T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 23/33 OPTREX Confidential8.2.Definition of Viewing Angle and Optimum Viewing Area (4 & Ut MBH) *Point e shows the point where contrast ratio is measured. : 0= 0, b= - IYVRPAIBIER : 0=0, 6= +++ OFA U5 *Driving condition: Ff=60Hz (BABI) 90 8 goe 480 (> = 0) o 180 p | 0 270 270 *Area [| shows typ. CR>30 CR230 2 Yt ET SBME LA B+ T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 24/33 OPTREX Confidential9.Test (it E) No abnormal function and appearance are found after the following tests. Pat Oper & Sith LIRR, RBROMECRRBRS &, Conditions: Unless otherwise specified, tests will be conducted under the following condition. Temperature: 20+5C Humidity : 65+5%RH tests will be not conducted under functioning state. See: RCSA OME ORO. YARE 2045C, WEEE 654+5%, EMAAR CTT. No. Parameter( B ) ConditionsGAsRAN ZA) Notes(/# ac) 1 | High Temperature Operating | 70C+2C, 96hrs (operation state) Gia) (rin B/E AER) 2 | Low Temperature Operating | -20C+2C, 96hrs (operation state) (iH 7) 1 (AEG Yi B/E) 3 | High Temperature Storage 80C+2C, 96hrs 2 (Trilin PR TF AER) 4 | Low Temperature Storage -30C+2C, 96hrs 1,2 {Eth PR TF ER) 5 | Damp Proof Test 40C+2C,90~95%RH, 96hrs 1,2 (iE ABR) 6 | Vibration Test Total fixed amplitude(@ 4%) : 1.5mm 3 (fee ER) Vibration Frequency (tie Jal }Z BO : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes (1 EE 1 DH XLY.Z3 HA & 15 4A) 7 | Shock Test To be measured after dropping from 60cm high on (EAR) the concrete surface in packing state. CERLORA CUA RBIS T 60cm DR S25 FRO BAAS avy VbhARAE RP) Dropping method corner dropping( #54 F) | F Acorner : once(1 [Bl) E g D Edge dropping (#3 TF) a 3 | 4 B,C,D edge : once(1 I) Face dropping(Hi3# F) [econ E,F,G face : once(1 [l) Concrete Surface( 7 J KR) Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container. TEL: RRR LARWOE, TE2: GRA, HUMIC 4 PE LER, WETS. TE3 : Rare Vd Ya CIT 9. T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 25/33 OPTREX Confidential10.Appearance Standards (4+ #e#h# ) 10.1.Inspection conditions(*+}#R7#@ A 4) try Pov & OPE 30cm LAE CA RIC EORAATT I. 10.2.Definition of applicable Zones(U + F/LOiWA YY VOPR) | Bezel Frame ooo as A Zone B Zone C Zone A Zone : Active display area C Zone : Rest parts A Zone + B Zone = Validity viewing area AY-y: Fy bi BY-Y: By KE RV BeICRENE MD CY-Y . EO OMD AY-Vt+BY-Y=49i POA The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line. tu Ve ART STMUL, BRIO LCHIREA 45 ORAL TS, B Zone : Area from outside of "A Zone" to validity viewing area T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 26/33 OPTREX Confidential10.3.Standards(#it8) No. Parameter({4 8) Criteria(Hl 2 28%) 1 G Line (G74 VY) Nothing(@#& = &. ) 2 S Line (S 7-7 Y) Nothing(@#& = &. ) 3 Leak () 7) Nothing(@#& = &. ) 4 Bright and Dark dot Zone( fis) Acceptable Number(#? A (20 CHEAR + HR) A Bright Dot (42.8) 0 Dark Dot (#772) 2 B Bright Dot (#2) 2 Dark Dot (#772) 4 Cc Disregard(# th) Definition of Bright dot (HEA ER Anything that can be seen through 10% trancmission ND filter when black Signal is inputted. GEE LOMO BIE 4 VA IP LICMRS FL ZTRVY b DILL TS ) Adjacent Dot :Horizontal and Vertical Continuous Bright dots. (BERE Bey booKOER OEE 7 EOE) Nothing(#@ = &. ) 5 Contrast Variation Not to be conspicuous defects. (AV RFARAD)| HLWaAVRFARAPREZIE, ) T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 27/33 OPTREX ConfidentialNo. Parameter({4 8) Criteria(Hl 2 28%) 6 Black and White (1) Round Shape(FK@ } ) Spots, Foreign Zone( fink) Acceptable Number(# 4 (4120 Material in Polarizer Dimension(X & &) (mm) A B C and LR/AR Coat DS05 Disregard(# th) Bright point 0.15 2. 0 _ 0 CEE) _ W>0. 03 0 X:Length GeS) Y: Width (i) Total defects shall not exceed 2. (QAR OFFERS 2 EPS, ) 7 Color Variation Not to be conspicuous defects. (ft?) (BLWRAROREIE, ) 8 Air Bubbles (between glass Zone( fia) Acceptable Number(#F 7 (2120) & polarizer) Dimension(X & &) (mm) A B C (CAR A) D <0. 10 Disregard(# th) 0.10 < D <0. 15 1 Disregard 0.15 < D <0. 20 1 (Ef) < D <0. 20 0 The polarizer edge has not floated. (Ha DAVY CWA ES) 9 Polarizer Scratches | Not to be conspicuous defects. (Hin HER AE A) CGELWRROREIE, ) 10 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is (Ain TEARTE AV) defective. (HICKS RNS EOMEMETS, ) T-55343GD035JU-LW-ADN OPTREX CORPORATION Page 28/33 OPTREX Confidential11.Code System of Production Lot (##oOow k}Be) The production lot of module is specified as follows. eV a VOR y hel, KROL IICH CTS, OOOoOoOoOoO-oOdo | Leet Control Number(3 22 5 )(0~99) _ of the week(icil# H) (A~G) Factory Number (47 4%) (0~9) Factory Code(4# it 5 )(Alphabet) Production Week (#174) (1~5) Production Month (#2: 5) (1~9, X, Y, Z) Production Year (&3#4) (Lower 2 digits / PHRF F 2 #1) 12.Type Number (#3 # xt) The type number of module is specified as follows. IDEV a NOMA, ROE DICRRTS, 355343AD 13.Applying Precautions (@ AE OB) Please contact us when questions and/or new problems not specified in this Specifications arise. AUTRE IC BES 6 Be88, Ec A DOD EE Lice. a thats MUBETOIEETS, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 29/33 OPTREX Confidential14.Precautions Relating Product Handling (3) RMMU EOS) The Following precautions will guide you in handling our product correctly. Aig ih 2 EL < CREATAS Alc, ROBAIC CER PSY, 1) Liquid crystal display devices 1. The liquid crystal display panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. 2. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 1) FARR SAF ILOWYT DRA ARE Y a VICE CW SB RRA IL, WD A CHEEIVTWE TO CHRY R BATE eS ATRUY OCR EW, BleuABELEBAIL, FEI CTD 5b IR YO MUNCIE TIE mFS, Q MARR OR MICHA Y AUT TC d OM ICARIL, MRD DUMTEP OCR COSA, BROTR A . WEDIZCL TFA, { 2) Care of the liquid crystal display module against static electricity discharge. 1. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats (made of rubber), to protect worktables against the hazards of electrical shock. 2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. 3. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 2) WAR ACE V 2 VOW UIC OUN CO GEE) D AK, SERA BICEP TAR LTREW, EL, RRA OMRY ay 7 BOM MO hOA, HRV y hk (PN) eKIBOLET, Q) PES HET CARDS AL STU EOE a IBD LET, \o saae LETOC, WARP ORET 1 VAIL < OD EHDBULTFAW, / 3) When the LCD module must be stored for long periods of time: 1.Protect the modules from high temperature and humidity. Conditions: Temperature: 0C~40C Humidity : Less than 60%RH No dew condensation to be observed. 2.Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3.Protect the modules from excessive external forces. 4.After a long period storage of the product (or LCD) under the low temperature and the dark, it might take a longer time to turn on the CCFL than normal. 3) WAAR a ee BS CER LRU IUER RUBE ITOWYT DO lik, uO AT CRB LARAUY CR EU, KR EAE: OC~40C 6O%RH LAT RE OREZES IL, @ HAAS. & SUITED ERS Fe DRWE DIC UT FSU, @ IMBAPbRTTRADIID SRV E AIC LTR SY D (EROTIC SIVOW SGA, TAIT E CICA DPS IO EDBAVET, 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 4) YR Ya VICI, RRB Ao CBO EEAOC, AOA MHA. UE Int Pade [ALES Nee OD FE Oe SEB E&Y, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 30/33 OPTREX Confidential5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 5) WHA Y 2 RRL i CRI) Db LCE RBA. HICANRWEDIEL TRS), PRD FECAIRR CIC LEBEITIZ, EDDIC AIT ACHE LT FEU, 6) Conductivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 6) AP VARVE BAT SPRABIC BUY T,X BARB & EIS LCR ERR D Bolt, Bile ETA, MES e PSNABSI, DheoOMR PSY, 7) For models which use CFL: 1. High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. 2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. 3. The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. 4. After storing the product (or LCD) under low temperature and/or in dark atmosphere for a long period of time, CCFL may take longer time to reach its specified brightness. 7) CF L@HAS ORMIC OWT OCFLI-7FVOAAKY SBI, LOVE LORBESAIIMAN COEF, RAIA 6 EKGORAERDETOC, RORMVICCEB PSY. QCFLY-TVA, EP heh URE BR LRU E DIC CIEE FEU, Q@ CF LIX, (kil CHE H LEwe. AMOI OM CHL HC ROE, (Kit & OMS ATIC ERE SAV CW SUA, ITE CILIA PPS UO EDBAVET, 8) For models which use touch panels: 1.Do not stack up modules since they can be damaged by components on neighboring modules. 2.Do not place heavy objects on top of the product. This could cause glass breakage. 8) Fy FARMER S BRIT OUT O BOBS e LACKEY, Dy VY CREE BOSIEBHVET, Q Lice Wer iBaaevyo FAV. 9) For models which use COG,TAB,or COF: 1.The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. 2.Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. 9) COG, TAB, COF SENT SMRICOVYT O LCF yFRHBCORERH LCOS &, PAAR AMR < ROTO ED, BRUCE T th LCF y PRC AAAI Dd bRWLIFGERLT PAY. Q 1CFyARHMBCOLERHLCHOOS, BRMMGRM Ibe UCL CH y PRI BRE ARDEA T HS LD RA ILUEIT CR SU, Eve, WICK ORB SILL, BRE HERS 57D, ED Seb RSE Le LT FSU, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 31/33 OPTREX Confidential10)Models which use flexible cable, heat seal, or TAB: 1.In order to maintain reliability, do not touch or hold by the connector area. 2.Avoid any bending, pulling, or other excessive force, which can result in broken connections. 10) PU, EP hY OV, TABATA RBIC OY D (ARERR OA, ARTZ Ya VERO TRUYC FAV), @ WO ATHBPEDS BA, PEPE ZED O HIT Oe, Slog SORA eMARVYC FAV, 11)In case of buffer material such as cushion / gasket is assembled into LCD module, it may have an adverse effect on connecting parts (LCD panel-TCP / HEAT SEAL / FPC / etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT SEAL-FPC, etc.,) depending on its materials. Please check and evaluate these materials carefully before use. Ll) PREV ao y va Vie OBR, Jy vari GOMAIC LO. Waa EY a Bact (LCD NRE TCP/E bi / FRC, PCB & TCP/E BY / FRC. TCP/E hi / EPC HOPE OBES) [CRE RIES AT AEPED & OE TOC HAC +a elie LCR SU, 12)In case of acrylic plate is attached to front side of LCD panel, cloudiness (very small cracks) can occur on acrylic plate, being influenced by some components generated from polarizer film. Please check and evaluate those acrylic materials carefully before use. 12) Wel ORNCY 7 VRE RIT Owe, TIT UV VOMEIC EO, tAOEAR > FEE TOMA ORE CT 7 UNIT AP GOMR I Py 7) DIBAT SA RTTEPED HO ETO C, SERS +4) Reith 2 Ze hi LCR SU, T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 32/33 OPTREX Confidential15.Warranty (4 dik & # ) This product has been manufactured to your companys specifications as a part for use in your companys general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 4x ill, LOR eae AO & OC, ether Chalice MIS SNES OCt> 0. SRA ATER EER EER IC ERLT SEOCH, B. Saxe EADS A TEL Ene A tric id S eas, J TERS. UZ Rs, BTR ALE OH Ce Maa Phe BOR SNS RICH SNOB, MEE LCL WHORES AWERL, il, PPO RIMEASNSRA, RMR ECA SROs, BRI LIAS LO BRR CLEVE. 1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. WMI brie. Oy: AEe at) (KB SRARGICOSELTI, CORE RAW EAL, = 2. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 2. MAD MDPoKILICLVIBETSRRSICOS ELIZ, COREZ AWE, 3. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your companys acceptance inspection procedures. 3. EE TRAC CAR LY HR SIR, TERESA SI CBEFT SFR GICOEE LULL, COREPAWERH, 4. When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. 4. CFL&(EAT ARAMICBIYC, CF LOAN CHET, (HAT S14 YAN #8 OPETE? J 7ECRELETF., RATER COMBE, (ARERR ORRGICOS ELL, COREA Wk, 5. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 5. Sie LEC eich RATS CMA O MAIC OUVCIL, Six OIC MIRC S bOWMCORELTIXZ, CORFZAWVETA, 6. Optrex will not be held responsible for any quality issue(s) after two years and beyond from its production date indicated on the lot number (please refer to Code System of Production Lot indicated earlier in this specification). Mehl HATS tHE SNCF G OE eaEM COS EL CI, Meee hY 2eL SE THSEET, GRA ICO CILILI OURO Meo y hs] SBE, ) @ T-55343GD035JU-LW-ADN (AD) OPTREX CORPORATION Page 33/33 OPTREX Confidential