M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 1Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Wet Tantalum Capacitors, Military Established Reliability,
MIL-PRF-39006/09/21 Qualified Styles CLR65, CLR69
FEATURES
Hermetically sealed
Metal cased
Axial lead
•Tubular
STYLE, MILITARY SPECIFICATION
CLR65, M39006/09 MIL-PRF-39006/09
CLR69, M39006/21 MIL-PRF-39006/21
PERFORMANCE CHARACTERISTICS
Operating Temperature: -55 °C to +125 °C
(above 85 °C, voltage derating is required)
Capacitance Range: M39006/09 - 1.7 μF to 1200 μF;
M39006/21 - 6.8 μF to 2200 μF
Capacitance Tolerance: ± 5 %, ± 10 %, ± 20 %
Voltage Rating: 6 VDC to 125 VDC
Established Reliability Tantalum Capacitors to Military
Specification MIL-PRF-39006: in accordance with the
military specification MIL-PRF-39006 all capacitors are
marked with the military part number (M39006/xx-xxxx)
rather than the older style designation (CLR65, CLR69) and
should be ordered as such.
For information on the performance characteristics of these
capacitors, please refer to the latest issue of the military
specification.
Each order for military style capacitors requiring
government inspection must state whether inspection is to
be at the destination or at the Vishay plant. Orders requiring
source inspection cannot be shipped until this has been
accomplished.
ORDERING INFORMATION
M39006 /09 -8005
BASIC DOCUMENT NUMBER SLASH SHEET DASH NUMBER
Indicates the basic specification;
in this case MIL-PRF-39006
Indicates the specification sheet
of the basic military specification
Taken from
Standard/Extended Ratings tables
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 2Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
(1) For reference only
DIMENSIONS in inches [millimeters]
CASE CODE
BARE CASE WITH INSULATING SLEEVE E
LEAD LENGTH
WEIGHT
(oz./g)
(MAX.)
D L D (MAX.) L
(1)
T1 0.188 ± 0.016
[4.78 ± 0.41]
0.453 + 0.031/- 0.016
[11.51 + 0.79/- 0.41]
0.219
[5.56]
0.515
[13.08]
1.500 ± 0.250
[38.10 ± 6.35]
0.07
[2.0]
T2 0.281 ± 0.016
[7.14 ± 0.41]
0.641 + 0.031/- 0.016
[16.28 + 0.79/- 0.41]
0.312
[7.92]
0.704
[17.88]
2.250 ± 0.250
[57.15 ± 6.35]
0.18
[5.1]
T3 0.375 ± 0.016
[9.53 ± 0.41]
0.766 + 0.031/- 0.016
[19.46 + 0.79/- 0.41]
0.406
[10.31]
0.828
[21.03]
2.250 ± 0.250
[57.15 ± 6.35]
0.36
[10.2]
T4 0.375 ± 0.016
[9.53 ± 0.41]
1.062 + 0.031/- 0.016
[26.97 + 0.79/- 0.41]
0.406
[10.31]
1.126
[28.60]
2.250 ± 0.250
[57.15 ± 6.35]
0.49
[13.9]
RATINGS AND CASE CODES - M39006/09
μF 6 8 10 15 25 30 50 60 75 100 125
1.7 T1
2.5 T1
3.5 T1
3.6 T1
4.0 T1
4.7 T1
5.0 T1
6.8 T1
8.0 T1
8.2 T1
9.0 T2
10 T1 T1
11 T2
15 T1 T1 T2
20 T1 T2
22 T1 T2
25 T1 T2 T3
30 T1 T3
33 T1 T2
39 T2
40 T2 T3
43 T3
47 T1 T2
50 T3
56 T1 T3 T4
60 T3
68 T1 T2 T3
70 T2
82 T3
86 T4
100 T2 T2 T3
-+
ELE
Terminal
welded
to case
External
weld
Tantalum feed-through
0.078 [1.98] max. dia.
Insulating sleeve
Term. loc. within
0.031 [0.79] R
of true position
0.250 [6.35]
max.
D dia.
0.025 ± 0.002
[0.64 ± 0.05]
Glass
Circuit diagram
0.094 [2.38]
max.
Style CLR65
Style CLR69
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 3Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
110 T4
120 T2
140 T2 T4
150 T3
160 T4
170 T3
180 T2 T3
220 T2
250 T3
270 T2 T3
300 T4
330 T3
350 T4
390 T3
430 T3
540 T4
560 T3
750 T4
850 T4
1200 T4
RATINGS AND CASE CODES - M39006/21
μF 6 8 10 15 25 30 50 60 75 100 125
6.8 T1
10 T1
22 T1
27 T1 T2
33 T1
39 T2
47 T3
56 T1
68 T1 T3
82 T2 T4
100 T1 T2
120 T2 T4
150 T1
180 T1 T3
220 T1 T2 T3 T4
270 T2 T3 T4
330 T4
390 T2
470 T3
560 T2 T3 T4
680 T2 T4
820 T2 T3
1000 T4
1200 T3
1500T3T3T4
1800 T4
2200 T4
RATINGS AND CASE CODES - M39006/09
μF 6 8 10 15 25 30 50 60 75 100 125
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 4Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
STANDARD RATINGS/EXTENDED RATINGS: CLR65 (1), M39006/09-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
6 VDC AT +85 °C; 4 VDC AT +125 °C
30 T1 20 8001 8206 1 2 9.1 100 -40 +10.5 +12
30 T1 10 8002 8207 1 2 9.1 100 -40 +10.5 +12
30 T1 5 8003 8208 1 2 9.1 100 -40 +10.5 +12
68 T1 20 8004 8209 1 2 20.4 60 -40 +14 +16
68 T1 10 8005 8210 1 2 20.4 60 -40 +14 +16
68 T1 5 8006 8211 1 2 20.4 60 -40 +14 +16
140 T2 20 8007 8212 1 3 21.3 40 -40 +14 +16
140 T2 10 8008 8213 1 3 21.3 40 -40 +14 +16
140 T2 5 8009 8214 1 3 21.3 40 -40 +14 +16
270 T2 20 8010 8215 1 6.5 81.8 25 -44 +17.5 +20
270 T2 10 8011 8216 1 6.5 81.8 25 -44 +17.5 +20
270 T2 5 8012 8217 1 6.5 81.8 25 -44 +17.5 +20
330 T3 20 8013 8218 2 7.9 49.6 20 -44 +14 +16
330 T3 10 8014 8219 2 7.9 49.6 20 -44 +14 +16
330 T3 5 8015 8220 2 7.9 49.6 20 -44 +14 +16
560 T3 20 8016 8221 2 13 128 25 -64 +17.5 +20
560 T3 10 8017 8222 2 13 128 25 -64 +17.5 +20
560 T3 5 8018 8223 2 13 128 25 -64 +17.5 +20
1200 T4 20 8019 8224 3 14 144.4 20 -80 +25 +25
1200 T4 10 8020 8225 3 14 144.4 20 -80 +25 +25
8 VDC AT +85 °C; 5 VDC AT +125 °C
25 T1 20 8021 8226 1 2 7.6 100 -40 +10.5 +12
25 T1 10 8022 8227 1 2 7.6 100 -40 +10.5 +12
25 T1 5 8023 8228 1 2 7.6 100 -40 +10.5 +12
56 T1 20 8024 8229 1 2 17 59 -40 +14 +16
56 T1 10 8025 8230 1 2 17 59 -40 +14 +16
56 T1 5 8026 8231 1 2 17 59 -40 +14 +16
220 T2 20 8027 8232 1 7 66.4 30 -44 +17.5 +20
220 T2 10 8028 8233 1 7 66.4 30 -44 +17.5 +20
220 T2 5 8029 8234 1 7 66.4 30 -44 +17.5 +20
430 T3 20 8030 8235 2 14 91.5 25 -64 +17.5 +20
430 T3 10 8031 8236 2 14 91.5 25 -64 +17.5 +20
430 T3 5 8032 8237 2 14 91.5 25 -64 +17.5 +20
850 T4 20 8033 8238 4 16 65.8 22 -80 +25 +25
850 T4 10 8034 8239 4 16 65.8 22 -80 +25 +25
10 VDC AT +85 °C; 7 VDC AT +125 °C
20 T1 20 8035 8240 1 2 6.1 175 -32 +10.5 +12
20 T1 10 8036 8241 1 2 6.1 175 -32 +10.5 +12
20 T1 5 8037 8242 1 2 6.1 175 -32 +10.5 +12
47 T1 20 8038 8243 1 2 18.1 100 -36 +14 +16
47 T1 10 8039 8244 1 2 18.1 100 -36 +14 +16
47 T1 5 8040 8245 1 2 18.1 100 -36 +14 +16
100 T2 20 8041 8246 1 4 15.2 60 -36 +14 +16
100 T2 10 8042 8247 1 4 15.2 60 -36 +14 +16
100 T2 5 8043 8248 1 4 15.2 60 -36 +14 +16
180 T2 20 8044 8249 1 7 54.4 40 -36 +14 +16
180 T2 10 8045 8250 1 7 54.4 40 -36 +14 +16
180 T2 5 8046 8251 1 7 54.4 40 -36 +14 +16
250 T3 20 8047 8252 2 10 37.8 30 -40 +14 +16
250 T3 10 8048 8253 2 10 37.8 30 -40 +14 +16
250 T3 5 8049 8254 2 10 37.8 30 -40 +14 +16
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 5Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
10 VDC AT +85 °C; 7 VDC AT +125 °C
390 T3 20 8050 8255 2 16 87.6 25 -64 +17.5 +20
390 T3 10 8051 8256 2 16 87.6 25 -64 +17.5 +20
390 T3 5 8052 8257 2 16 87.6 25 -64 +17.5 +20
750 T4 20 8053 8258 4 16 56.5 23 -80 +25 +25
750 T4 10 8054 8259 4 16 56.5 23 -80 +25 +25
15 VDC AT +85 °C; 10 VDC AT +125 °C
15 T1 20 8055 8260 1 2 5.7 155 -24 +10.5 +12
15 T1 10 8056 8261 1 2 5.7 155 -24 +10.5 +12
15 T1 5 8057 8262 1 2 5.7 155 -24 +10.5 +12
33 T1 20 8058 8263 1 2 12.5 90 -28 +14 +16
33 T1 10 8059 8264 1 2 12.5 90 -28 +14 +16
33 T1 5 8060 8265 1 2 12.5 90 -28 +14 +16
70 T2 20 8061 8266 1 4 13.1 75 -28 +14 +16
70 T2 10 8062 8267 1 4 13.1 75 -28 +14 +16
70 T2 5 8063 8268 1 4 13.1 75 -28 +14 +16
120 T2 20 8064 8269 1 7 36.8 50 -28 +17.5 +20
120 T2 10 8065 8270 1 7 36.8 50 -28 +17.5 +20
120 T2 5 8066 8271 1 7 36.8 50 -28 +17.5 +20
170 T3 20 8067 8272 2 10 25.4 35 -32 +14 +16
170 T3 10 8068 8273 2 10 25.4 35 -32 +14 +16
170 T3 5 8069 8274 2 10 25.4 35 -32 +14 +16
270 T3 20 8070 8275 2 16 60.9 30 -56 +17.5 +20
270 T3 10 8071 8276 2 16 60.9 30 -56 +17.5 +20
270 T3 5 8072 8277 2 16 60.9 30 -56 +17.5 +20
540 T4 20 8073 8278 6 24 49 23 -80 +25 +25
540 T4 10 8074 8279 6 24 49 23 -80 +25 +25
25 VDC AT +85 °C; 15 VDC AT +125 °C
10 T1 20 8075 8280 1 2 4.6 220 -16 +8 +9
10 T1 10 8076 8281 1 2 4.6 220 -16 +8 +9
10 T1 5 8077 8282 1 2 4.6 220 -16 +8 +9
22 T1 20 8078 8283 1 2 8.3 140 -20 +10.5 +12
22 T1 10 8079 8284 1 2 8.3 140 -20 +10.5 +12
22 T1 5 8080 8285 1 2 8.3 140 -20 +10.5 +12
100 T2 20 8081 8286 1 10 31.4 50 -28 +13 +15
100 T2 10 8082 8287 1 10 31.4 50 -28 +13 +15
100 T2 5 8083 8288 1 10 31.4 50 -28 +13 +15
180 T3 20 8084 8289 2 18 54.3 32 -48 +13 +15
180 T3 10 8085 8290 2 18 54.3 32 -48 +13 +15
180 T3 5 8086 8291 2 18 54.3 32 -48 +13 +15
350 T4 20 8087 8292 7 28 35 24 -70 +25 +25
350 T4 10 8088 8293 7 28 35 24 -70 +25 +25
30 VDC AT +85 °C; 20 VDC AT +125 °C
8.0 T1 20 8089 8294 1 2 4.5 275 -16 +8 +12
8.0 T1 10 8090 8295 1 2 4.5 275 -16 +8 +12
8.0 T1 5 8091 8296 1 2 4.5 275 -16 +8 +12
15 T1 20 8092 8297 1 2 9.1 175 -20 +10.5 +12
15 T1 10 8093 8298 1 2 9.1 175 -20 +10.5 +12
15 T1 5 8094 8299 1 2 9.1 175 -20 +10.5 +12
40 T2 20 8095 8300 1 5 12.2 65 -24 +10.5 +12
40 T2 10 8096 8301 1 5 12.2 65 -24 +10.5 +12
40 T2 5 8097 8302 1 5 12.2 65 -24 +10.5 +12
STANDARD RATINGS/EXTENDED RATINGS: CLR65 (1), M39006/09-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 6Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
30 VDC AT +85 °C; 20 VDC AT +125 °C
68 T2 20 8098 8303 1 8 31 60 -24 +13 +15
68 T2 10 8099 8304 1 8 31 60 -24 +13 +15
68 T2 5 8100 8305 1 8 31 60 -24 +13 +15
100 T3 20 8101 8306 2 12 19 40 -28 +10.5 +12
100 T3 10 8102 8307 2 12 19 40 -28 +10.5 +12
100 T3 5 8103 8308 2 12 19 40 -28 +10.5 +12
150 T3 20 8104 8309 2 18 46 35 -48 +13 +15
150 T3 10 8105 8310 2 18 46 35 -48 +13 +15
150 T3 5 8106 8311 2 18 46 35 -48 +13 +15
300 T4 20 8107 8312 8 32 35 25 -60 +25 +25
300 T4 10 8108 8313 8 32 35 25 -60 +25 +25
50 VDC AT +85 °C; 30 VDC AT +125 °C
5.0 T1 20 8109 8314 1 2 3.4 400 -16 +5 +6
5.0 T1 10 8110 8315 1 2 3.4 400 -16 +5 +6
5.0 T1 5 8111 8316 1 2 3.4 400 -16 +5 +6
10 T1 20 8112 8317 1 2 6 250 -24 +8 +9
10 T1 10 8113 8318 1 2 6 250 -24 +8 +9
10 T1 5 8114 8319 1 2 6 250 -24 +8 +9
25 T2 20 8115 8320 1 5 11.2 95 -20 +10.5 +12
25 T2 10 8116 8321 1 5 11.2 95 -20 +10.5 +12
25 T2 5 8117 8322 1 5 11.2 95 -20 +10.5 +12
47 T2 20 8118 8323 1 9 21.4 70 -28 +13 +15
47 T2 10 8119 8324 1 9 21.4 70 -28 +13 +15
47 T2 5 8120 8325 1 9 21.4 70 -28 +13 +15
60 T3 20 8121 8326 2 12 13.6 45 -16 +10.5 +12
60 T3 10 8122 8327 2 12 13.6 45 -16 +10.5 +12
60 T3 5 8123 8328 2 12 13.6 45 -16 +10.5 +12
82 T3 20 8124 8329 2 16 24.9 45 -32 +13 +15
82 T3 10 8125 8330 2 16 24.9 45 -32 +13 +15
82 T3 5 8126 8331 2 16 24.9 45 -32 +13 +15
160 T4 20 8127 8332 8 32 25.7 27 -50 +25 +25
160 T4 10 8128 8333 8 32 25.7 27 -50 +25 +25
60 VDC AT +85 °C; 40 VDC AT +125 °C
4.0 T1 20 8129 8334 1 2 3 550 -16 +5 +6
4.0 T1 10 8130 8335 1 2 3 550 -16 +5 +6
4.0 T1 5 8131 8336 1 2 3 550 -16 +5 +6
8.2 T1 20 8132 8337 1 2 5 275 -24 +8 +9
8.2 T1 10 8133 8338 1 2 5 275 -24 +8 +9
8.2 T1 5 8134 8339 1 2 5 275 -24 +8 +9
20 T2 20 8135 8340 1 5 7.6 105 -16 +10.5 +12
20 T2 10 8136 8341 1 5 7.6 105 -16 +10.5 +12
20 T2 5 8137 8342 1 5 7.6 105 -16 +10.5 +12
39 T2 20 8138 8343 1 9 20.7 90 -28 +10.5 +12
39 T2 10 8139 8344 1 9 20.7 90 -28 +10.5 +12
39 T2 5 8140 8345 1 9 20.7 90 -28 +10.5 +12
50 T3 20 8141 8346 2 12 15.3 50 -16 +10.5 +12
50 T3 10 8142 8347 2 12 15.3 50 -16 +10.5 +12
50 T3 5 8143 8348 2 12 15.3 50 -16 +10.5 +12
68 T3 20 8144 8349 2 16 30.7 50 -32 +10.5 +12
68 T3 10 8145 8350 2 16 30.7 50 -32 +10.5 +12
68 T3 5 8146 8351 2 16 30.7 50 -32 +10.5 +12
140 T4 20 8147 8352 8 32 25.7 28 -40 +20 +20
140 T4 10 8148 8353 8 32 25.7 28 -40 +20 +20
STANDARD RATINGS/EXTENDED RATINGS: CLR65 (1), M39006/09-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 7Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
75 VDC AT +85 °C; 50 VDC AT +125 °C
3.5 T1 20 8149 8354 1 2 2.5 650 -16 +5 +6
3.5 T1 10 8150 8355 1 2 2.5 650 -16 +5 +6
3.5 T1 5 8151 8356 1 2 2.5 650 -16 +5 +6
6.8 T1 20 8152 8357 1 2 4.1 300 -20 +8 +9
6.8 T1 10 8153 8358 1 2 4.1 300 -20 +8 +9
6.8 T1 5 8154 8359 1 2 4.1 300 -20 +8 +9
15 T2 20 8155 8360 1 5 7.5 150 -16 +8 +9
15 T2 10 8156 8361 1 5 7.5 150 -16 +8 +9
15 T2 5 8157 8362 1 5 7.4 150 -16 +8 +9
33 T2 20 8158 8363 1 10 17.5 90 -24 +10.5 +15
33 T2 10 8159 8364 1 10 17.5 90 -24 +10.5 +15
33 T2 5 8160 8365 1 10 17.5 90 -24 +10.5 +15
40 T3 20 8161 8366 2 12 15.2 60 -16 +10.5 +12
40 T3 10 8162 8367 2 12 15.2 60 -16 +10.5 +12
40 T3 5 8163 8368 2 12 15.2 60 -16 +10.5 +12
56 T3 20 8164 8369 2 17 26 60 -28 +10.5 +15
56 T3 10 8165 8370 2 17 26 60 -28 +10.5 +15
56 T3 5 8166 8371 2 17 26 60 -28 +10.5 +15
110 T4 20 8167 8372 9 36 25.7 29 -35 +20 +20
110 T4 10 8168 8373 9 36 25.7 29 -35 +20 +20
100 VDC AT +85 °C; 65 VDC AT +125 °C
2.5 T1 20 8169 8374 1 2 5 950 -16 +7 +8
2.5 T1 10 8170 8375 1 2 5 950 -16 +7 +8
2.5 T1 5 8171 8376 1 2 5 950 -16 +7 +8
4.7 T1 20 8172 8377 1 2 3.6 500 -16 +7 +8
4.7 T1 10 8173 8378 1 2 3.6 500 -16 +7 +8
4.7 T1 5 8174 8379 1 2 3.6 500 -16 +7 +8
11 T2 20 8175 8380 1 4 5 200 -16 +7 +8
11 T2 10 8176 8381 1 4 5 200 -16 +7 +8
11 T2 5 8177 8382 1 4 5 200 -16 +7 +8
22 T2 20 8178 8383 1 9 11.8 100 -16 +7 +8
22 T2 10 8179 8384 1 9 11.8 100 -16 +7 +8
22 T2 5 8180 8385 1 9 11.8 100 -16 +7 +8
30 T3 20 8181 8386 2 12 9.1 80 -16 +7 +8
30 T3 10 8182 8387 2 12 9.1 80 -16 +7 +8
30 T3 5 8183 8388 2 12 9.1 80 -16 +7 +8
43 T3 20 8184 8389 2 17 19.7 70 -20 +7 +8
43 T3 10 8185 8390 2 17 19.7 70 -20 +7 +8
43 T3 5 8186 8391 2 17 19.7 70 -20 +7 +8
86 T4 20 8187 8392 9 36 20.7 30 -25 +15 +15
86 T4 10 8188 8393 9 36 20.7 30 -25 +15 +15
STANDARD RATINGS/EXTENDED RATINGS: CLR65 (1), M39006/09-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 8Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
125 VDC AT +85 °C; 85 VDC AT +125 °C
1.7 T1 20 8189 8394 1 2 7 1250 -16 +7 +8
1.7 T1 10 8190 8395 1 2 7 1250 -16 +7 +8
1.7 T1 5 8191 8396 1 2 7 1250 -16 +7 +8
3.6 T1 20 8192 8397 1 2 4.1 600 -16 +7 +8
3.6 T1 10 8193 8398 1 2 4.1 600 -16 +7 +8
3.6 T1 5 8194 8399 1 2 4.1 600 -16 +7 +8
9.0 T2 20 8195 8400 1 5 10.2 240 -16 +7 +8
9.0 T2 10 8196 8401 1 5 10.2 240 -16 +7 +8
9.0 T2 5 8197 8402 1 5 10.2 240 -16 +7 +8
25 T3 20 8204 8409 2 13 19 93 -16 +7 +8
25 T3 10 8205 8410 2 13 19 93 -16 +7 +8
25 T3 5 9026 9029 2 13 19 93 -16 +7 +8
56 T4 20 9027 9030 10 40 17.5 32 -25 +15 +15
56 T4 10 9028 9031 10 40 17.5 32 -25 +15 +15
STANDARD RATINGS / EXTENDED RATINGS: CLR69 (1), M39006/21-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
6 VDC AT +85 °C; 4 VDC AT +125 °C
220 T1 20 0001 0089 2 9 50 36 -64 +13 +16
220 T1 10 0002 0090 2 9 50 36 -64 +13 +16
820 T2 20 0003 0091 3 14 155 18 -88 +16 +20
820 T2 10 0004 0092 3 14 155 18 -88 +16 +20
1500 T3 20 0005 0093 5 20 172 18 -90 +20 +25
1500 T3 10 0006 0094 5 20 172 18 -90 +20 +25
2200 T4 20 0007 0095 6 24 170 13 -90 +25 +30
2200 T4 10 0008 0096 6 24 170 13 -90 +25 +30
8 VDC AT +85 °C; 5 VDC AT +125 °C
180 T1 20 0009 0097 2 9 41 45 -60 +13 +16
180 T1 10 0010 0098 2 9 41 45 -60 +13 +16
680 T2 20 0011 0099 3 14 130 22 -83 +16 +20
680 T2 10 0012 0100 3 14 130 22 -83 +16 +20
1500 T3 20 0013 0101 5 20 170 18 -90 +20 +25
1500 T3 10 0014 0102 5 20 170 18 -90 +20 +25
1800 T4 20 0015 0103 7 25 138 14 -90 +25 +30
1800 T4 10 0016 0104 7 25 138 14 -90 +25 +30
Note
(1) Style CLR69 is inactive for new military design. For new design use style CLR81
STANDARD RATINGS/EXTENDED RATINGS: CLR65 (1), M39006/09-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 9Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
10 VDC AT +85 °C; 7 VDC AT +125 °C
150 T1 20 0017 0105 2 9 34 54 -55 +13 +16
150 T1 10 0018 0106 2 9 34 54 -55 +13 +16
560 T2 20 0019 0107 3 16 106 27 -77 +16 +20
560 T2 10 0020 0108 3 16 106 27 -77 +16 +20
1200 T3 20 0021 0109 5 20 137 18 -88 +20 +25
1200 T3 10 0022 0110 5 20 137 18 -88 +20 +25
1500 T4 20 0023 0111 7 25 114 15 -88 +25 +30
1500 T4 10 0024 0112 7 25 114 15 -88 +25 +30
15 VDC AT +85 °C; 10 VDC AT +125 °C
100 T1 20 0025 0113 2 9 30 72 -44 +13 ++16
100 T1 10 0026 0114 2 9 30 72 -44 +13 +16
390 T2 20 0027 0115 3 16 74 31 -66 +16 +20
390 T2 10 0028 0116 3 16 74 31 -66 +16 +20
820 T3 20 0029 0117 6 24 111 22 -77 +20 +25
820 T3 10 0030 0118 6 24 111 22 -77 +20 +25
1000 T4 20 0031 0119 8 32 92 17 -77 +25 +30
1000 T4 10 0032 0120 8 32 92 17 -77 +25 +30
25 VDC AT +85 °C; 15 VDC AT +125 °C
68 T1 20 0033 0121 2 9 22 90 -40 +12 +15
68 T1 10 0034 0122 2 9 22 90 -40 +12 +15
270 T2 20 0035 0123 3 16 55 33 -62 +13 +16
270 T2 10 0036 0124 3 16 55 33 -62 +13 +16
560 T3 20 0037 0125 7 28 76 24 -72 +20 +25
560 T3 10 0038 0126 7 28 76 24 -72 +20 +25
680 T4 20 0039 0127 8 32 63 19 -72 +25 +30
680 T4 10 0040 0128 8 32 63 19 -72 +25 +30
30 VDC AT +85 °C; 20 VDC AT +125 °C
56 T1 20 0041 0129 2 9 22 100 -38 +12 +15
56 T1 10 0042 0130 2 9 22 100 -38 +12 +15
220 T2 20 0043 0131 3 16 42 36 -60 +13 +16
220 T2 10 0044 0132 3 16 42 36 -60 +13 +16
470 T3 20 0045 0133 8 32 64 25 -65 +20 +25
470 T3 10 0046 0134 8 32 64 25 -65 +20 +25
560 T4 20 0047 0135 9 36 55 20 -65 +25 +30
560 T4 10 0048 0136 9 36 55 20 -65 +25 +30
50 VDC AT +85 °C; 30 VDC AT +125 °C
33 T1 20 0049 0137 2 9 12.3 135 -29 +10 +12
33 T1 10 0050 0138 2 9 12.3 135 -29 +10 +12
120 T2 20 0051 0139 4 24 22.5 49 -42 +12 +15
120 T2 10 0052 0140 4 24 22.5 49 -42 +12 +15
270 T3 20 0053 0141 8 32 37 29 -46 +20 +25
270 T3 10 0054 0142 8 32 37 29 -46 +20 +25
330 T4 20 0055 0143 9 36 38 22 -46 +25 +30
330 T4 10 0056 0144 9 36 38 22 -46 +25 +30
60 VDC AT +85 °C; 40 VDC AT +125 °C
27 T1 20 0057 0145 3 12 10.2 144 -24 +10 +12
27 T1 10 0058 0146 3 12 10.2 144 -24 +10 +12
100 T2 20 0059 0147 4 20 19 54 -36 +12 +15
100 T2 10 0060 0148 4 20 19 54 -36 +12 +15
220 T3 20 0061 0149 8 32 30 29 -40 +16 +20
220 T3 10 0062 0150 8 32 30 29 -40 +16 +20
270 T4 20 0063 0151 9 36 27 23 -45 +20 +25
270 T4 10 0064 0152 9 36 27 23 -45 +20 +25
STANDARD RATINGS / EXTENDED RATINGS: CLR69 (1), M39006/21-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR69 is inactive for new military design. For new design use style CLR81
M39006/09, M39006/21
www.vishay.com Vishay
Revison: 28-Aug-17 10 Document Number: 40159
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
75 VDC AT +85 °C; 50 VDC AT +125 °C
22 T1 20 0065 0153 3 12 8.5 157 -19 +10 +12
22 T1 10 0066 0154 3 12 8.5 157 -19 +10 +12
82 T2 20 0067 0155 4 24 15.2 63 -30 +12 +15
82 T2 10 0068 0156 4 24 15.2 63 -30 +12 +15
180 T3 20 0069 0157 9 36 24.4 30 -35 +16 +20
180 T3 10 0070 0158 9 36 24.4 30 -35 +16 +20
220 T4 20 0071 0159 10 40 37 24 -40 +20 +25
220 T4 10 0072 0160 10 40 37 24 -40 +20 +25
100 VDC AT +85 °C; 65 VDC AT +125 °C
10 T1 20 0073 0161 3 12 4.5 200 -17 +10 +12
10 T1 10 0074 0162 3 12 4.5 200 -17 +10 +12
39 T2 20 0075 0163 5 24 10.4 80 -20 +12 +15
39 T2 10 0076 0164 5 24 10.4 80 -20 +12 +15
68 T3 20 0077 0165 10 40 11.3 40 -30 +14 +16
68 T3 10 0078 0166 10 40 11.3 40 -30 +14 +16
120 T4 20 0079 0167 12 48 25 30 -35 +15 +17
120 T4 10 0080 0168 12 48 25 30 -35 +15 +17
125 VDC AT +85 °C; 85 VDC AT +125 °C
6.8 T1 20 0081 0169 3 12 6 300 -14 +10 +12
6.8 T1 10 0082 0170 3 12 6 300 -14 +10 +12
27 T2 20 0083 0171 5 24 7.2 90 -18 +12 +15
27 T2 10 0084 0172 5 24 7.2 90 -18 +12 +15
47 T3 20 0085 0173 10 40 7.9 50 -26 +14 +16
47 T3 10 0086 0174 10 40 7.9 50 -26 +14 +16
82 T4 20 0087 0175 12 48 17.4 32 -30 +15 +17
82 T4 10 0088 0176 12 48 17.4 32 -30 +15 +17
VOLTAGE DERATING WITH TEMPERATURE
STANDARD RATINGS / EXTENDED RATINGS: CLR69 (1), M39006/21-XXXX
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21-
FAILURE RATE
LEVEL (%/1000 h)
MAX. DCL (μA)
AT MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
L
2.0
M
1.0 +25 °C +85 °C
+125 °C -55 °C +85 °C +125 °C
Note
(1) Style CLR69 is inactive for new military design. For new design use style CLR81
100
80
60
40
20
0
- 55 - 35 - 5 25 45 65 85 105 125
PERCENT OF RATED VOLTAGE
TEMPERATURE IN °C
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 08-Feb-17 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED