HCA & HCA-RA Series – Hermeti cally Sealed AC LVDT
HCA-RA-Series Rev. 8 www.meas-spec.com 2015-July
1/6
• Hermetically sealed, all welded
• Stainless steel housing
• MS type conn ector, glass sealed
• Axial or radial electrical connection
• IEC IP68 rating to 1,000 PSI [70 bars]
• Stroke ranges from ± 0.05 to ±10 inches
• AC operation from 400Hz to 10kHz
• Double ma g n etic shielding
• Through bore design (HCA-RA version)
DESCRIPTION
The HCA and HCA-RA Series hermetically sealed LVDTs provide premium performance in harsh industrial environments.
Impervious to dirt, water, steam, and corrosive liquids/vapors compatible with its materials, the HCA/HCA-RA all-welded
stainless steel construction withstands external pressures up to 1,000 PSI [70 bars]. Double magnetic shielding offers
excellent protection from external electromagnetic fields.
The HCA/HCA-RA Series can be configured with a number of standard options. A high temperature operation version
(200ºC) is also available (consult factory). The HCA/HCA-RA is compatible with the full line of Measurement Specialties
LVDT signal conditioners.
The HCA-RA version adds the convenience of a radial connector termination. This feature decreases the required
installation space, while also allowing debris to harmles sly pass through the ‘open-ended’ bor e.
Like in most of our LVDTs, the HCA/HCA-RA windings are vacuum impregnated with a specially formulated, high
temperature, flexible resin, and the coil assembly is potted inside its housing with a two-component epoxy. This provides
excellent protection against hostile environments such as high vibration and shock.
Captive core option: The HCA/HCA-RA features an optional captive core design that greatly s implifies installation. The core
rod and bearing assembly includes a Bronze bearing on the front end for self-alignment, while a PTFE sleeve allows low-
friction travel through the stainless steel boreliner (spool tube). The core rod and the bearing assembly are both field
serviceable.
Also see our other hermetic LVDT models with built-in signal conditioning: HCD (DC voltage), HCT (4-20mA, 2-wire loop)
and HC-485 (RS-485 Digital Series), also av aila ble in the –RA versions.
Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners. Data sheets
can be downloaded from our web site at: http://www.meas-spec.com/datasheets.aspx
Measurement Specialties a cq uired Scha ev itz Sensors and the SchaevitzTM trademark in 2000.
FEATURES APPLICATIONS
•
All-welded stainless steel construction
•
Harsh industrial environments
•
Glass sealed, MS type connector (MIL-C-5015)
•
Submersible (with appropriate connector)
•
Shock and vibration tolerant
•
•
Captive core eases installation (optional)
• Corrosive liquid and vapor areas (check
materials)
•
High temperature version available (200ºC)
•
Calibration certificate supplied with each unit
•
•
Right angle (HCA-RA) version available
•