1
CSM_E3S_DS_E_7_1
Photoelectric Sensor with Built-in Amplifier
E3S
General-purpose Photoelectric
Sensor for High Quality and Reliable
Detection
Be sure to read Safety Precautions
on page 8.
Ordering Information
General-purpose Sensors
Note: Sensors with open collectors and different frequencies are available.
*1. Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver.
Orders for individual Emitters and Receivers are accepted.
*2. The difference between the E3S-
@@
(
@@@
) 41 and E3S-
@@
(
@@@
) 42 is in the lens direction when the Sensor is mounted.
For details, refer to the dimensions that are provided on page 10 for the E3S-5E41, page 11 for the E3S-DS30E41, and page 12 for the E3S-5E42 and E3S-DS30E42.
Sensing method Appearance Sensing distance Operation mode Model
Through-beam *1
Light-ON/Dark-ON
(selectable)
E3S-2E4
Emitter E3S-2LE4
Receiver E3S-2DE4
E3S-5E4
Emitter E3S-5LE4
Receiver E3S-5DE4
Retro-reflective E3S-R2E4
Diffuse-reflective
E3S-DS10E4
E3S-DS30E4
Through-beam *1
E3S-2E41
Emitter E3S-2LE41
Receiver E3S-2DE41
E3S-5E41 (42) *2
Emitter E3S-5LE41 (42)
Receiver E3S-5DE41 (42)
Retro-reflective E3S-R2E41
Diffuse-reflective
E3S-DS10E41
E3S-DS30E41 (42) *2
Convergent-reflective
(narrow vision field) E3S-LS10XE4
Convergent-reflective
(wide vision field) E3S-LS20XE4
2 m
5 m
0.1 to 2 m
100 mm
300 mm
2 m
5 m
0.1 to 2 m
100 mm
300 mm
30 to 100 mm (variable)
50 to 250 mm (variable)
E3S
2
Ratings and Specifications
* The ambient operating illumination is the illumination that changes the output ±20% at 200 lx. It is not the operational limit.
Sensing method Through-beam Retro-re-
flective Diffuse-reflective Convergent-reflective
Item
Model E3S-2E4
E3S-2E41
E3S-5E4
E3S-5E41
(42)
E3S-R2E4
E3S-
R2E41
E3S-
DS10E4
E3S-
DS10E41
E3S-
DS30E41
(42)
E3S-
DS30E4S
E3S-
LS10XE4
E3S-
LS20XE4
Sensing distance 2 m 5 m 0.1 to 2 m
100 mm
(white paper
50 x 50 mm)
300 mm
(white paper 100 x 100)
30 to 100 mm
Continuously
variable
(10 x 10 mm)
50 to 250 mm
Continuously
variable
(50 x 75 mm)
Standard sensing
object
Opaque: 7-
mm dia. min.
Opaque: 11-
mm dia. min.
Opaque: 30-
mm dia. min. Transparent, opaque
Differential travel --- 20% max. of setting distance
0.5 mm max.
at 30 mm 5% max. at 50
to 250 mm
3 mm max. at
100 mm
Directional angle Both emitter and receiver:
3° to 10°3° to 10°---
Light source
(wavelength)
Infrared LED
(950 nm)
RED LED
(660 nm)
Infrared LED
(950 nm)
Power supply
voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Current
consumption
50 mA max.
(Emitter: 25 mA max.,
Receiver: 25 mA max.)
40 mA max.
Control output
(solid-state out-
put)
Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) Refer to page 4.
Response time Operate or reset: 3 ms max. Operate or reset: 1 ms max.
Sensitivity
adjustment With an indicator
Ambient
illumination
(Receiver side) *
Incandescent lamp: 3,000 lx max.
Sunlight: 10,000 lx max.
Ambient
temperature Operating: 25 to 55°C, Storage: 40 to 70°C (with no icing or condensation)
Ambient humidity Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation
resistance 20 MΩ min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration
resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction) 500 m/s2 3 times each in X, Y, and Z directions
Degree of
protection IEC IP65 IEC IP67 IEC IP65 IEC IP67
Connection
method Pre-wired cable (standard length: 2 m)
Indicators Light indicator (red), Stability indicator (green)
Material
Case
Polybuty-
lene tereph-
thalate
Zinc die-cast
Polybuty-
lene tereph-
thalate
Zinc die-cast
Lens *Polycarbonate
Mount-
ing
Bracket
Iron
E3S
3
Engineering Data (Typical)
Parallel Operating Range
E3S-2E4 (41) E3S-5E4 (41) (42)
Operating Range
E3S-DS10E4 (41) E3S-DS30E4 (41) (42)
E3S-LS10XE4 E3S-LS20XE4
100
90
80
70
60
50
40
30
20
10
00.5 1 1.5 2 2.5 3
E3S-2E41
E3S-2E4
Distance X
Parallel movement
distance Y
Distance X (m)
Parallel movement distance Y (mm)
240
220
200
180
160
140
120
100
80
60
40
20
01 2 3 4 65 7
Distance X
Parallel movement
distance Y
Distance X (m)
Parallel movement distance Y (mm)
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
100 140 16040 60 8020 120
(Y)
(Y)
Optical axis
Operating position Y (mm)
Operating
distance
X (mm)
Operating
distance (X) Standard sensing object
(50 x 50 mm)
Operating
position
10
8
6
4
2
0
2
4
6
8
10
100 140 160
40 60 80
20 120
(Y)
(Y)
Optical axis
Operating position Y (mm)
Operating
distance (X) Standard sensing object
(100 x 100 mm)
Operating
position
Operating
distance
X (mm)
3
2
1
0
1
2
3
120100 140 16040 60 8020
Adjust the
distance: 30 mm Adjust the
distance: 100 mm
(Y)
(Y)
Optical axis
Operating position Y (mm)
Operating
distance (X) Standard sensing object
(10 x 10 mm)
Operating
position
Operating
distance
X (mm)
20
15
10
5
0
5
10
15
20
250 300 350100 150 20050
3
2
1
0
1
2
3
Max. distance set
(Y)
(Y)
Optical axis
Operating position Y (mm)
Standard sensing object
(50 x 75 mm)
Operating
position
Operating
distance (X)
Operating
distance
X (mm)
Min. distance set
(Range at minimum setting)
E3S
4
Sensing Distance vs. Size of Sensing Object Parallel Operating Range
E3S-DS30E4 (41) (42) E3S-R2E4 (41) (42)
E3S-DS10E4 (41) E3S-LS20XE4
Excess Gain vs. Set Distance Load Residual Voltage Characteristics
E3S-LS10XE4 E3S-LS3RC4
E3S-DS30E4 (1) (2)
600
500
400
300
200
100
0100 15050
E3S-DS10E4 (1)
The larger the sensing object,
the longer the operating distance.
d
d
White
paper
Side length (one side) of sensing object d (mm)
Operating distance (mm)
Sensing
object
500
400
300
200
100
0100 15050
Short edge of sensing object (mm)
Short edge
Short: Long ratio = 2:3
White
paper
Operating distance (mm)
Sensing object
Long
edge
100
80
60
40
20
02.82.421.61.2 3.20.80.4
Distance X
Parallel movement
distance Y
Distance X (m)
Parallel movement distance Y (mm)
10,000
5,000
3,000
1,000
500
300
100
50
30
0140 1606040 80 100 12020
Received light output peak:
100 mm
Received light
output peak:
30 mm
Sensitivity adjuster at
maximum setting
The characteristics are for
when the distance where the
received light output reaches
its peak is set to 30, 50, and
100 mm using the distance
adjuster.
Received light
output peak:
50 mm
Distance (mm)
Operating
level
Receiver output (mV)
100
50
30
10
5
3
1
0.5
0.3
044 5220 28 36
Setting
distance
Set distance (mm)
Excess Gain Ratio (times)
Operating voltage
Standard sensing object
(white paper)
Standard sensing
object
(black carbon)
2.0
1.5
1.0
0.5
0100 150 20050 8020
Load current (mA)
Residual voltage (V)
E3S
5
I/O Circuit Diagrams
Item Opera-
tion
mode
Output circuit Timing charts
Model
Wire
color
Power
polarity
E3S
Brown +
Light-ON
Blue 0 V
Brown 0 V
Dark-ON
Blue +
Brown *1 12 to 24 VDC
*2
0 V
Load 1
(relay)
Load 2
Black
Blue *1
1.5 to
4 mA
Z
Photo-
electric
Sensor
main
circuit
Stability
indicator
(green)
Light
indicator
(red)
Z: Zener diode (Vz = 30 V)
*1: Reverse the polarity of the power supply to switch the
operating mode.
*2: Voltage output (when connecting transistor circuit)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
H
L
Light
indicator
(red)
Output
transistor
Load 1
(e.g., relay)
Load 2
(Between brown and black)
(Between blue and black)
Brown *1
12 to 24 VDC
*2
0 V
Load 1
(relay)
Load 2
Black
Blue *1
1.5 to
4 mA
Z
Photo-
electric
Sensor
main
circuit
Stability
indicator
(green)
Light
indicator
(red)
Z: Zener diode (Vz = 30 V)
*1: Reverse the polarity of the power supply to switch the
operating mode.
*2: Voltage output (when connecting transistor circuit)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
H
L
Light
indicator
(red)
Output
transistor
Load 1
(e.g., relay)
Load 2
(Between brown and black)
(Between blue and black)
E3S
6
Connection
With Relay Load
Through-beam Sensors
Light Interrupted and Load Operating for E3S-2E4 (41)
and -5E4 (41) (42)
Note: The indicator will function as a light indication if the Emitter's pink wire is
connected to the Receiver's black wire as indicated by the dotted line. The
indicator will function as a power indicator if the Emitter's pink wire is
connected to the Emitter's blue wire.
Retro-reflective Sensors
Light Interrupted and Load Operating for E3S-R2E4 (41)
(42), -DS10E4(41), and -DS30E4 (41) (42)
Connection with S3D2 Sensor Controller
Reverse operation is possible using the signal input switch on the S3D2.
Load
Pink
Blue Blue
Brown Brown
Black
Receiver
80 mA max.
12 to
24 V
0 V0 V
12 to
24 V
Emitter Load
Blue
Output
Brown
Black
80 mA max.
12 to 24 V
0 V
Sensing
method Through-beam Reflective
Connection
method
123
654
10 11 12
987
Blue Blue
Brown
Brown
Black
Receiver
0 V
12 V
Emitter
IN1
S3D2 123
654
10 11 12
987
Blue
Brown
Black
0 V
12 V
IN
1
S3D2
E3S
7
Adjustment Methods
Adjusting the E3S-LS10XE4 Convergent-reflective
Sensor
1. Attach the distance adjustment scale as shown in the figure
and set it where the * mark is equal to the sensing distance.
2. Turn the distance adjuster until the red spot is at point
(center of the distance adjustment scale).
3. Remove the distance adjustment scale once the distance
has been adjusted. Put a sensing object in place, and then
adjust the sensitivity.
Adjusting the E3S-LS20XE4 Convergent-reflective
Sensor
Adjustment Method 1
Use this method if the sensing object is more reflective than
the background.
1. Set the sensitivity adjuster to the center as shown in the
figure.
2. Turn the distance adjuster counterclockwise until it is fully
turned (L to S).
3. Position the sensing object.
4. Slowly turn the distance adjuster clockwise (S to L).
5. Eventually the LIGHT (red) indicator will light. Turning the
adjuster further will light the STABILITY (green) indicator.
Leave the distance adjuster at this level.
6. Adjust the sensitivity in this state.
Adjustment Method 2
Use this method if the background is more reflective than the
sensing object.
1. Set the sensitivity adjuster to the center as shown in the
figure.
2. Turn the distance adjuster clockwise until it is fully turned (S
to L).
3. Remove the sensing object.
4. Slowly turn the distance adjuster counterclockwise (L to S).
5. Eventually the LIGHT (red) indicator will light. Turning the
adjuster further will light the STABILITY (green) indicator.
6. Adjust the sensitivity in this state.
Distance adjustment scale
Align the distance adjustment scale
with the groove on the Sensor.
E3S-LS10XE4
A
Distance adjuster
Sensitivity adjustment
*
A
Distance adjuster Sensing object
Center
Background
object
Distance adjuster Sensing object
Center
Background
object
E3S
8
Safety Precautions
This product is not designed or rated for
ensuring safety of persons.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that
exceed product ratings.
If the sensing object has a metallic or shiny surface, the E3S-
R may not detect it properly. To avoid this situation, place the
sensing object so that it is not at right angles to the
Photoelectric Sensor.
Attaching the E39-S Slit
The Slit can be fitted vertically or horizontally as indicated
by the dotted line. Make sure that Slits for the Emitter and
the Receiver are fitted in the same orientation.
Place the packing in the supporter and hook the claws on
the indentations in the Sensor head.
If the supporter is contacting the mounting surface, insert a
spacer to separate it. (Refer to Slit Dimensions.)
An operating position accuracy of 0.1 mm max. can be
achieved for a Through-beam Sensor without Slits.
Sensor with Slits
Sensors with Open-collector Outputs
Sensors with Open-collector Outputs
The model numbers are as follows:
Example:
E3S-DS10E4 (E type)
E3S-DS1C4 (C type)
E3S-DS1B4 (B type)
C4 (C41, C42) Sensors
C4 (B41, B42) Sensors
Note 1. Only C42 models with die-cast cases are available.
2. The Emitter for a Through-beam C4-type Sensor is the same as the
Emitter for an E4-type Sensor. (E.g., E3S-5LE4)
3. When a C- or B- type Sensor experiences a load short-circuit or overload,
the output transistor will be turned OFF. Check the load conditions before
turning the power back ON.
WARNING
Precautions for Correct Use
Applicable
Photoelectric
Sensor
E3S-5E4, -5E41 (42) E3S-2E4, -2E41
Model E39-S1 E39-S2
Item Slit
width 0.5 mm 1 mm 2 mm 4 mm 0.5 mm 1 mm 2 mm
Sensing
distance 230 mm 580 mm 1200 mm 2500 mm 170 mm 420 mm 820 mm
Sensing object 0.5 mm 1 mm 2 mm 4 mm 0.5 mm 1 mm 2 mm
Degree of
protection IP60
Create an angle.
Glossy surface Sensing object
10° to 20°
Reflector
Supporter
Cut-out section Claws
Slit
Sensor head
Indentation
Protrusion
Packing B
Packing A
Type Output
type
Output
transistor
Rated
current
output
Switching
current
Output
protection
circuit
E
Voltage or
current
output
NPN 1.5 to
4mA
80 mA max.
(sinking)
Provided against
an increase in the
residual output
voltage
C
Open-
collector
output
NPN ---
100 mA
max.
(sinking)
Provided:
Output transistor
cutoff
B
Open-
collector
output
PNP ---
100 mA
max.
(sourcing)
Provided:
Output transistor
cutoff
Brown *
0 V
Load
(relay)
Black (output)
Blue *
Photo-
electric
Sensor
main
circuit
+V
Z
2.2 Ω
Brown *
0 V
Load
(relay)
Black (output)
Blue *
Photo-
electric
Sensor
main
circuit
+V
Z
2.2 Ω
Z: Zener diode (Vz = 30 V)
* The operation mode depends on the wiring of the
brown and blue lines.
E3S
9
Sensors with Different Orientations
The E3S-5, E3S-DS30, and E3S-R2 that sense in different
directions can be made.
Sensing
method Sensing direction
Through-
beam
E3S-5E43
E3S-5E44
Retro-
reflective
Diffuse-
reflective
E3S-DS30E43
E3S-R2E43
Emitter
Receiver
Emitter
Receiver
E3S
10
(Unit: mm)
Dimensions Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
General-purpose Sensors
Note: Models numbers for Through-beam Sensors (E3S-@E4, E3S-@E41) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "L" to the set model number (example: E3S-2LE4), the model number of the Receiver, by adding "D"
(example: E3S-2DE4.) Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
15.4
43.2
16 916.7
16.7
9
16.2
25.1
1.2 2.7
18.8
Indicator
9.9
40
(50)
16 9
43.2
5.5 20
30
5
11.4
Two, M3
a*1
Lens: 7 dia.
E39-L3
6 dia.
12.8 dia.
Sensitivity adjuster*2
4-dia. vinyl-insulated round cable with 2/3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Emitter and Receiver, 80 g each
*1 The mounting bracket can also be used on side a.
*2 Receiver only.
E3S-2E4
15.4
43.2
16 916.7
16.7
9
25.1
1.2
18.8
32.3
40
(50)
8.3 9
43.2
5.5 20
30
5
11.4
Indicator
Two, M3
a*1
Lens: 7 dia. 6 dia.
12.8 dia.
Sensitivity adjuster*2
*1 The mounting bracket can also be used on side a.
*2 Receiver only.
4-dia. vinyl-insulated round cable with 2/3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Emitter and Receiver, 80 g each
E3S-2E41
20
5
4.2 5
1.9
6.5
4.2
20
22.2
20.4
12
22
(32)
1.6
23
20
2.1R
39
25.4
55
(67)
11 13 7
2.1R
Indicator
E39-L6
a*
1
Lens: 11 dia.
13 dia.
Sensitivity adjuster*
2
4-dia. vinyl-insulated round cable with 2/3 conductors
(Conductor cross section: 0.2 mm
2
,
Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Emitter and Receiver, 155 g each
Two, M4
slotted hexagonal bolts
*
1
The mounting bracket can also be used on side a.
*
2
Receiver only.
E3S-5E4
20
5
4.2 5
1.9
6.5
4.2
20
22.2
20.4
12
(32)
1.6
23
20
2.1R 2.1R
39
18.6
25.4
63
(75)
11 13 7
Indicator
a*1
Lens: 11 dia.
13 dia.
Sensitivity adjuster*2
4-dia. vinyl-insulated round cable with 2/3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Emitter and Receiver, 165 g each
Two, M4
slotted hexagonal bolts
*1 The mounting bracket can also be used on side a.
*2 Receiver only.
E3S-5E41
E3S
11
15.4
43.2
16 916.7
21
10.5 40
(50)
16 9
4
3.2
5.5 20
30
5
11.4
16.7
9
16.8
27.3
1.2
Indicator
Two, M3
a*
Lens: 7 x 13
6 dia. 12.8 dia.
Sensitivity adjuster
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 80 g
Emitter
Receiver
* The mounting bracket can also be used on side a.
E3S-DS10E4
21
115
15.4
43.2
16 916.7
40
29.5
(50)
5.5
4
3.2
5.5 20
30
5
16.7
9
27.3
1.2
Indicator
Two, M3
Lens: 7 x 13
Sensitivity
adjuster
Emitter
Receiver
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 80 g
6 dia.
12.8 dia.
a*
* The mounting bracket can also be used on side a.
E3S-DS10E41
20.4
(32)
6.5 4.2
2.1R
2.1R
4.2
5
25.4
39 1.9
55
(67)
13 7
11
20
23
7.1
22.2
20
5
20
12
22
24.9
1.6
Indicator
Two, M4
slotted hexagonal bolts
Lens: 10 x 15
13 dia.
Sensitivity adjuster
Emitter
Receiver
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 155 g
a*
* The mounting bracket can also be used on side a.
E3S-R2E4
E3S-DS30E4
18.6
(32)
23
20
22.2
6.5
4.2
2.1R
2.1R
4.2
5
25.4
39
63
(75)
13 7
11
20
5
20
12
1.6
20.4
1.9
Indicator
Two, M4
slotted hexagonal bolts
Lens: 10 x 15
13 dia.
Sensitivity adjuster
Emitter Receiver
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 165 g
a*
* The mounting bracket can also be used on side a.
E3S-R2E41
E3S-DS30E41
E3S
12
Note: Models numbers for Through-beam Sensors (E3S-5E42) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "L" to the set model number (example: E3S-5LE42), the model number of the Receiver, by adding "D"
(example: E3S-5DE42.) Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
5
5
1311
(32)
23
20
12
1.6
(32)
23
20
22.2
12
1.6
22.2
6.5 4.2
2.1R
2.1R
4.2
5
25.4
39 1.9
63
(75)
24 7
20
20
13 dia.
6.5 4.2
2.1R
2.1R
4.2
5
25.4
39
18.6
18.6
1.9
63
(75)
7
20
20
20.4
20.4
10.2
10.2
Indicator
Two, M4
slotted hexagonal bolts
Lens: 11 dia.
13 dia.
Sensitivity adjuster
Emitter
Receiver
4-dia. vinyl-insulated round cable with 2/3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 165 g
Two, M4
slotted hexagonal bolts
Lens: 11 dia.
Indicator
a*
* The mounting bracket can also be used on side a.
E3S-5E42
20
5
4.2 5
1.9
6.5
4.2
20
13 dia.
22.2
10.2
20.4
12
(32)
1.6
7.1
23
20
21.5
18.6
2.1R
39
25.4
63
(75)
11 13 7
2.1R
Indicator
Two, M 4
slotted hexagonal bolts
Sensitivity adjuster
Emitter
Receiver
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 165 g
Lens:
10 x 15
E3S-R2E42
E3S-DS30E42
20 6
45
45
55
5
4.9
50
16
2.1R
34
20
26 11
634.2
17
24 4.2
5
11
70
1.6
Indicator
Two, M4
slotted hexagonal bolts
Sensitivity adjuster
Emitter
Receiver
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m
Weight: Approx. 225 g
Lens:
14 x 47
Distance adjuster
Optical axis
Two,
4.4 dia.
8 dia.
a*
* The mounting bracket can also be used on side a.
E3S-LS10XE4
E3S-LS20XE4
Two, M3
20
Mounting Hole Dimensions
E3S-2E4
E3S-2E41
E3S-DS10E4
E3S-DS10E41
E3S-LS10XE4
E3S-LS20XE4
Two, M 4
25.4
E3S-5E4
E3S-5E41
E3S-R2E4
E3S-R2E41 (42)
E3S-DS30E4
E3S-DS30E41 (42)
E3S
13
Accessories (Order Separately)
5
25
5
4.2
10.2
20.2
25.4
5.6
41
2.1R
4.2
25.4
92.1
82.1
9 29.1
25.4
Two, M4 slotted
hexagonal bolts
Two, M4
Mounting Holes
Applicable models:
E3S-5E41
E3S-R2E41
E3S-DS30E41
Special Mounting Bracket
E39-L2
3.2
15.70
4
5
20
33
4
20
3.2
68.5
60.8
20 28.5
4
Two, M3
Mounting Holes
Applicable models:
E3S-2E41
E3S-DS10E41
20
Two, M3
E39-L4
34
40.3
5259.9
2.7
8
1.6
7.5
7
Two, 3.5 dia.
Material:
Reflective surface: Acrylic
Rear surface: ABS
Reflector
E39-R1
(Provided with the E3S-R2E4(41) Retro-reflective Reflector.)
4
13 dia.
9.3 dia.
Applicable models:
Provided with the E3S-5E4(41), E3S-DS30E4(41), E3S-R2E4(41).
Note: Cannot be used for the E3S-DS10E4 (41).
Sensitivity Adjuster (Provided)
E39-G1
E3S
14
13
17.8
10.5
1.8
1.2
17.9
(16.7)
E39-S2
*Spacer
Slit (Order Separately)
E39-S2
Note 1. Three sets of slits are provided:
6.5 x 0.5 mm, 6.5 x 1 mm and 6.5 x
2 mm
2. One set consists of two slits, one
each for the Emitter and Receiver.
Slit E39-S2
Applicable
Sensors
E3S-2E4
E3S-2E41
20
8.3
2.1
22.4 1.2
23.4
(22.2)
E39-S2
*Spacer
E39-S1
Note 1. Four sets of slits are provided:
11 x 0.5 mm, 11 x 1 mm, 11 x 2 mm,
and 11 x 4 mm
2. One set consists of two slits, one
each for the Emitter and Receiver.
Slit E39-S1
Applicable
Sensors
E3S-5E4
E3S-5E41
Note: The dimensions in parentheses are for when the Spacer is not used.
* With the E3S-2E4 (41), use the Spacer as shown in the figure above so that the supporter
and Mounting Bracket will not be struck when the optical axis is adjusted.
With the E3S-5E4 (41), the Spacer is not particularly required. Use the Spacer, however, to directly mount both the E3S-2E4 (41) and -5E4 (41).
In the interest of product improvement, specifications are subject to change without notice.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.