tfs70y.doc Version 3.0 VI TELEFILTER 06.06.2003 Filter Specification TFS 70 Y 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * ) : for input: for output: External coil: 23 0 C. dBm. 2,9 kOhm -3,8 pF 2,9 kOhm -3,8 pF 820 nH 2. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS70Y is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data typ. value Insertion Loss (Reference Level) ae 3,7 fc dB 70,002 MHz Centre frequency (at ambient temperature TA) Relative Attenuation fN - 35 kHz ... fN + 35 kHz ... fN 47 fN 35 arel kHz kHz fN fN fN fN kHz kHz kHz MHz 2,5 10 45 43 Tcf 2nd order **) - 0,043 ppm/K 60 90 450 500 kHz kHz kHz kHz ... fN 90 ... fN 450 ... fN 500 ... fN 10 Temperature Coefficient Turn over temperature 0,5 dB 2 dB T0 25 C - Operating Temperature Range Storage Temperature Range dB dB dB dB - Variation / Limitation max 6,0 70,0 dB 0,015 MHz max. max. 1 3 dB dB min. min. min. min. 1 3 35 40 dB dB dB dB - 5 C ... + 70 C - 30 C ... + 90 C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = Tcf(ppm/K) x (T - To) x fTo (MHz) generated: checked / approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70y.doc Version 3.0 VI TELEFILTER 06.06.2003 Filter Specification TFS 70 Y 2/5 3. Construction and Pin Configuration (All Dimensions in mm) 13,31 0,20 10 6,50 0,20 6 Date Code 5 1,800,2 1 1 2 3 4 5 6 7 8 9 10 Datecode Year+week N P R ... 2001 2002 2003 1,90,2 1,00,2 Input RF-Return Ground Ground Ground Output External Coil Ground Ground Ground Input 1,910,2 7,620,2 4. 50 Matching Network L1 10 C1 L2 5 SAW C2 6 1, 2, 3, 4, 7, 8, 9 L3 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70y.doc Version 3.0 VI TELEFILTER 06.06.2003 Filter Specification TFS 70 Y 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 1700 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) Do W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 24 4 1,5 1,75 11,5 0,6 2 12 1,5 7,1 13,9 21,5 Po P 2 + 0,3/ -0,1 0,1 + 0,1 0,1 0,1 E A F D 0,1 0,1 o CT B 0,1 0, 0,1 1 W o G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 24,4 +2 30,4 N (min) : 60 C : 13 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70y.doc Version 3.0 VI TELEFILTER 06.06.2003 Filter Specification TFS 70 Y 4/5 7. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 temperature / C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. Time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 Temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70y.doc Version 3.0 VI TELEFILTER Filter Specification 06.06.2003 TFS 70 Y 5/5 8. History Version Reason of Changes Name Date 1.0 - Generate development specification Steiner 30.07.2002 1.1 - Change package to 15*6,5 mm. Add second package option (11*5 mm) Change pass band width. Correct typo for stop band definition. Remove group delay limits. Introduce centre frequency limits. Change remark for characteristic. Dr. Wall 20.12.2002 2.0 - Change from development specification to preliminary specification. Remove package version 1. Change 1 dB bandwidth from 40 kHz to 35 kHz minimum. Change 3 dB bandwidth from 60 kHz to 47 kHz minimum. Change insertion loss from 10 dB to 6 dB maximum. Add typical values. Add termination impedances. Add packing information. Dr. Wall 13.05.2003 3.0 - Change from preliminary specification to filter specification. Change from 11*5 to 13*6,5 mm package. Change pinning. Change packing information. Change termination impedances. Add typical values. Dr. Wall 06.06.2003 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.