MIL-DTL-24308/23G
w/AMENDMENT 5
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Socket contact shall accommodate .041/.039 (1.04/0.99 mm) diameter pin for size 20 conta cts and .030 5/.0 295
(.775/.749 mm) diameter pin for size 22D contacts.
4. Point of electrical engagement. Use .0393/.0390 (0.998/0.990 mm) diameter square ended test pin.
5. Applicable insert patterns see MIL-DTL-24308, appendix A.
6. Copyright notice. All information disclosed in this military specification sheet which is or may be copyrighted by
ITT Cannon Electric is reproduced herein with the expressed permission of the copyright owner.
7. The 90 ° bracket shall be one piece flame resistant glass-filled nylon, polyester or two piece metal and nylon of
which the metal pieces shall be coated with a material in accordance with IPC-CC-830.
8. The 90 ° bracket shall be furnished as an integral part of the connector asse mbly .
9. Spacers will be supplied with connectors (not attached to the connector).
10. Layout shown for reference only to locate CL. See applicable insert arrangement.
11. Unles s otherwise specifie d, tol eran ce is ± .010 inch (0.25 mm).
12. In the event of a conflict between the text of this specification sheet and the references cited herein, the text of
this specification sheet shall take precedence.
13. Referenced Governments documents of the issue listed in ASSIST Online database at https://assist.dla.mil/
specified in t he solicitation form a part of this standard to the extent specified herein.
14. Indentation on the ends of the termination side of the shell, for the purpose of securing the insu lat or in the shell,
is permitted. This may result in the “F” dimension being undersized in these areas. However the “F” dimension
shall be maintained for the remainder of the connector.
15. For classes M, N and D use table I for applicable dash numbers.
FIGURE 1. Shell, receptacle, printed wiring board type - Continued.