Modified Sine Wave DC-AC Inverter with MPPT Solar Charger 1/2 E E E E E E E E E E E E ISI-500 series Features : High surge power up to 1000W Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over temp. / Output short / Input polarity reverse / Over load High frequecny design SPECIFICATION MODEL ISI-500-112 1/4 350W RATED POWER ISI-500-124 1/4 O AC Output voltage regulation : 10% AC Output wavform : Modified sine wave Modified models available(optional): 100/115/120VAC or 200/220/240VAC Cooling fan ON-OFF control Built-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.) Built-in battery low relay contact LED indicator for operation status 2 years warranty ISI-500-148 500W 1/4 500W ISI-500-212 1/4 350W ISI-500-224 1/4 500W ISI-500-248 1/4 500W MAXIMUM OUTPUT POWER (Typ.) 550W for 1 minute / surge power 1000W for 30 cycles (112, 212 models : 385W for 1 minute / surge power 700W for 30 cycles) WAVEFORM Modified sine wave OUTPUT AC VOLTAGE 110V 230V FREQUENCY 60Hz 0.5Hz 50Hz 0.5Hz O O10% LED INDICATOR BAT. VOLTAGE Green: Inverter OK Green (flashing): Inverter OK and charging Red: abnormal 24V 24V 48V 12V 12V 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 25A 12.5A 35A 25A 12.5A 0.4A 0.2A 0.8A 0.4A 0.2A 87% Open & sealed Lead Acid 87% 86% 88% 88% BATTERY TYPE VOLTAGE RANGE 20 ~ 40V Note.3,4 10.5 ~ 15VDC DC CURRENT (Typ.) 35A NO LOAD CURRENT DRAW 0.8A OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) SOLAR PANEL INPUT 48V 21 ~ 30VDC VOLTAGE RANGE INPUT O AC REGULATION O Note.1 85% 35 ~ 80V 70 ~ 160V 70 ~ 160V 15A 7.5A 20 ~ 40V 15A 35 ~ 80V MAX. SHORT CIRCUIT CURRENT 15A 15A 7.5A RATED CHARGE POWER (Typ.) 350W 14V 500W 28V 500W 56V 350W 14V 500W 28V 500W 20A 10A 25A 20A 30A 22V 15A 44V 40A 11V 30A 22V 21V 42V 10.5V 21V MAX. CHARGE VOLTAGE SOLAR CHARGER MAX. CHARGE CURRENT 25A FUSE 40A BATTERY BAT. LOW ALARM Note.4 11V INPUT PROTECTION BAT. LOW SHUTDOWN Note.4 10.5V By internal fuse REVERSE POLARITY OVER TEMPERATURE OUTPUT PROTECTION OUTPUT SHORT OVER LOAD 70 JO10J 65 56V 10A 15A 44V 42V JO10J Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect on power transistor Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec. FUNCTION BAT. LOW RELAY CONTACT Open : Battery low ; Short : Battery ok WORKING TEMP. Note.2 -20 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH J J J VIBRATION LVD WITHSTAND VOLTAGE 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes EN60950-1 None Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC EMC ISOLATION RESISTANCE EMC EMISSION EMS IMMUNITY MTBF 81.1K hrs min. OTHERS DIMENSION PACKING 205*158*67mm (L*W*H) 1.92Kg; 6pcs/12.5Kg/1.55CUFT NOTE J Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 class A Compliance to FCC part 15 class A None Compliance to EN61000-4-2,3,8 o MIL-HDBK-217F (25 C) 1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage. 2.Output derating capacity referenced by curve 1. 3.Input derating capacity referenced by curve 2. 4.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V. 5.All parameters not specified above are measured at rated load, 25 of ambient temperature. /O J /O /O File Name:ISI-500-SPEC 2013-01-14 ISI-500 Modified Sine Wave DC-AC Inverter with MPPT Solar Charger ISI 500 112 A A :TYPE B :TYPE C :TYPE D :TYPE E :TYPE U :TYPE 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC Modified sine wave inverter +MPPT solar charger Output: O/P Wattage:500W 1:110VAC 2:230VAC series A OUTLET B OUTLET C OUTLET D OUTLET E OUTLET U OUTLET AC Output Receptacles (optional) Receptacle type TYPE-A (Standard) TYPE-B (Standard) TYPE-C (Optional) TYPE-D (Optional) TYPE-E (Optional) TYPE-U (Optional) USA EUROPE AUSTRALIA U.K JAPAN UNIVERSAL Country Certificate Non Mechanical Specification Unit:mm 5 4 3 Input Terminal Pin No. Assignment 2 1 _ 67 Pin No. 1 2 3 Assignment FG Solar POS(+) Solar NEG(-) Pin No. 4 5 Assignment Battery POS(+) Battery NEG(-) SOLAR INPUT _ BATTERY INPUT Derating Curve Reverse Polarity Will Damage The Unit. 100 11 7.62 Air flow direction 6.35 80 42.5 LOAD (%) 13 18 8.9 9 60 50 40 7 20 -20 0 10 20 30 40 50 60 J 70 (HORIZONTAL) ENVIRONMENT TEMPERATURE ( ) 120 205 CURVE 1 100 LOAD (%) 80 60 40 20 10.5VDC 11.5VDC 15VDC (HORIZONTAL) 147 BATTERY INPUT VOLTAGE (V) CURVE 2 158 AC OUTPUT OFF Bat. Low Status alarm Type-A AC OUTPUT ON ON OFF Bat. Low Relay Connector : JST B-XH or equivalent Open Short Battery low Battery OK Bat. Low Status alarm Type-B File Name:ISI-500-SPEC 2013-01-14 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: ISI-500-248U