Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - HW Series Switches & Pilot Devices
634 www.IDEC.com 1904032200
HW Series — 22mm IEC Style Global Pushbuttons
Key features:
• Locking lever removable contact blocks
• Finger-safe IP20 contacts
• Tamperproof construction
• All E-stops meet EN60947-5-5, and are compliant with
SEMI S2 standards
• Worldwide approvals
• Easy to assemble
• Choice of black plastic or metallic front bezels
• LED illumination
• Transformer or full voltage
• Slow make double break contacts
HW: The Best Engineered Switch in the World
IDEC’s HW switches are “The best engineered switch in the world” for a reason. Carrying the CE
mark, UL, CSA, CCC (Chinese), and TUV approvals, these switches are designed for use in almost
any part of the world.
Complete with finger-safe contact blocks offering IP20 protection, these 7/8” (22mm) switches
include illuminated and non-illuminated pushbuttons, pilot lights, selector switches, and
emergency stop switches.
All switches also incorporate mechanically keyed safety locking levers, ensuring correct
installation and maintaining safety in high-vibration applications.
Certificate No.
R50086203_HW_e-stop
R50391189_HW
File No. E68961 File No. LR21451
Specifications
Electrical
Rated Operational Characteristics
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
Rated Insulation Voltage 600V
Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1
Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit
Rated Thermal Current 10 Amp
Minimum Switching Capacity 5 mA at 3V AC/DC
Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Lamp Ratings LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max
Mechanical
Contact Operation Slow break NC or NO
Positive Action Operation
(Emergency Stops with NC contacts)
5.5mm to 10mm travel to latch, 45N minimum force to latch
10mm maximum travel, 1,800 operations per hour maximum for a Pushlock Turn Reset
900 operations per hour maximum for a Push-Pull
Operating Force Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
Recommended Terminal Torque
Unit Wire Number of Wires Recommended
Tightening Torque (Nm) Terminal
Screw
HW-U Contact Block
Crimping Terminal 2 1.0 to 1.3
M3.5
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) 2 1.0 to 1.3
ø1.7 to 2.0 mm (AWG12) 1 1.2 to 1.3
Stranded Wire 0.3 to 2.0 mm2 (AWG14 to 22) 2 1.0 to 1.3
2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3
Illuminated Unit (*1)
Crimping Terminal
2 1.0 to 1.3 M3.5Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
Stranded Wire 0.3 to 2.0 mm (AWG14 to 22)
Applicable Wire Size Pilot Light
Crimping Terminal
2
0.6 to 1.0 (M3.0)
1.0 to 1.3 (M3.5)
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
Stranded Wire ø0.3 to 2.0 mm (AWG14 to 22)
1. * refers to the lamp terminals of the illuminated push buttons and selector switches.
Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Contact Resistance Initial contact resistance of 50mΩ or less
Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB)
Horsepower Rating Reference Value: 1/4 HP @ 120V (1ø non-reversing), 1HP @ 240V (3ø non-reversing)
Contact Material Silver (gold plated contacts available - contact IDEC)
Operating Temperature Operation: -25 to +60°C (illuminated -25 to +50°C dome -25 to +55°C)
Vibration Resistance 10 to 55Hz, 98m/sec2 (10G) conforming to IEC6068-2-6
Shock Resistance 980m/sec2 (100G) conforming to IEC6068-2-7
Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000
Certificate No.
2017010305987846