CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
1
Enclosed Switches
ZE/ZV/ZV2/XE/XV/XV2
General-purpose Enclosed
Switches with High Breaking
Capacity and High Durability
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
Terminals face the front when the cover is removed for
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read Safety Precautions on page 8 to 9 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3) (4)
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
(1) Built-in Switch
Z : SPDT (AC)
X : SPDT (DC)
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
(3) Actuator
Q : Plunger
Q22 : Roller plunger
Q21 : Crossroller plunger
QA2 : Roller arm lever
QA277 : One-way action roller arm lever
N : Sealed plunger
N22 : Sealed roller plunger (ZE, ZV, ZV2 only)
N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only)
NA2 : Sealed roller arm lever
NA277 : Sealed one-way action roller arm lever
(4) Conduit/Ground Terminal
*
None : G 1/2/without ground terminal
G1 : G 1/2/with ground terminal
G : Pg13.5/with ground terminal
SG1 : 1/2-14NPSM/with ground terminal
YG1 : M20/with ground terminal
S : 1/2-14NPSM/without ground terminal
Y : M20/without ground terminal
2
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Mounting
Side mounting Base mounting Diagonal side mounting
Actuator Model
Approved
standards Model
Approved
standards Model
Approved
standards
UL
CSA
UL
CSA
UL
CSA
General
purpose
Plunger
AC ZE-Q-2 ●●ZV-Q-2 ●●ZV2-Q-2 ●●
DC XE-Q-2 XV-Q-2 XV2-Q-2
Roller plunger
AC ZE-Q22-2 ●●ZV-Q22-2 ●●ZV2-Q22-2 ●●
DC XE-Q22-2 XV-Q22-2 XV2-Q22-2
Crossroller plunger
AC ZE-Q21-2 ●●ZV-Q21-2 ●●ZV2-Q21-2 ●●
DC XE-Q21-2 XV-Q21-2 ---
Roller arm lever
AC ZE-QA2-2 ●●ZV-QA2-2 ●●ZV2-QA2-2 ●●
DC XE-QA2-2 XV-QA2-2 XV2-QA2-2
One-way action roller
arm lever
AC ZE-QA277-2 ●● --- ZV2-QA277-2 ●●
DC XE-QA277-2 --- ---
Sealed
(Booted)
Sealed plunger
AC ZE-N-2 ●●ZV-N-2 ●●ZV2-N-2 ●●
DC XE-N-2 XV-N-2 XV2-N-2
Sealed roller plunger AC ZE-N22-2 ●●ZV-N22-2 ●●ZV2-N22-2 ●●
Sealed crossroller
plunger AC ZE-N21-2 ●●ZV-N21-2 ●●ZV2-N21-2 ●●
Sealed roller arm lever
AC ZE-NA2-2 ●●ZV-NA2-2 ●●ZV2-NA2-2 ●●
DC XE-NA2-2 XV-NA2-2 XV2-NA2-2
One-way action
sealed roller arm lever
AC ZE-NA277-2 ●●ZV-NA277-2 ●●ZV2-NA277-2 ●●
DC XE-NA277-2 --- XV2-NA277-2
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No.14 LR45746
CCC (CQC) GB14048.5 2003010303077623
Model Rated
voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
ZE-@
ZV-@
ZV2-@
125 VAC
250 VAC
480 VAC
15
15
10
3
2.5
1.5
1.5
1.25
0.75
15
15
6
5
3
1.5
2.5
1.5
0.75
125 VDC
250 VDC
0.5
0.25
0.5
0.25
0.05
0.03
0.05
0.03
XE-@
XV-@
XV2-@
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5
Inrush
current
NC 30 A max.
NO 15 A max.
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
3
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
CCC (GB14048.5)
Characteristics
Note: The above figures are initial values.
*1. IP65 for @-N models and IP60 for @-Q models.
*2. The values are calculated at an operating temperature of +5
°
C to +35
°
C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
Model Rated voltage Current Horsepower
ZE
125 VAC
250 VAC
480 VAC
15 A
15 A
15 A
1/8HP
1/4HP
125 VDC
250 VDC
0.5 A
0.25 A ---
Applicable category and ratings
AC-12 10 A/250 VAC
Degree of protection IP65*1
Durability
* 2
Mechanical Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Electrical
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Operating speed Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
Operating
frequency
Mechanical 120 operations/min
Electrical 20 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance 15 m max. (initial value)
Terminal temperature rise 50°C max.
Dielectric
strength
Between terminals
of the same polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-
carrying metal
part and ground
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Between each
terminal and
non-current-car-
rying metal part
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude*3
Shock
resistance
*3
Destruction 1,000m/s2 min.
Malfunction 100 m/s2 min.*4
50 m/s
2
min.*5
Ambient operating temperature
10°C to +80°C (with no icing)
Ambient operating humidity General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Weight Approx. 260 to 280 g
ZE (cosφ = 1)
ZE (cosφ = 0.4)
XE (L/R = 0)
XE (L/R = 7 ms)
1,000
50
100
500
02 4 6 8 10 12 1614
480 VAC
250 VAC
125 VAC
Switching current (A)
Durability (x 104 operations)
Operating frequency:
20 operations/min
OT: Full stroke
480 VAC
250 VAC
125 VAC
Switching current (A)
Durability (x 104 operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
50
100
500
02 4 6 8 10 12 1614
250 VAC
125 VAC
Switching current (A)
Durability (x 104 operations)
Operating frequency:
20 operations/min
OT: Full stroke
200
50
70
100
10235 10
250 VAC
125 VAC
100
20
30
50
70
10235 10
Switching current (A)
Durability (x 104 operations)
Operating frequency:
20 operations/min
OT: Full stroke
4
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
Note:
The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Contact Form
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Dimensions and Operating Characteristics (Unit: mm)
Side Mounting Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Pin plunger
Tightening band
Conduit
opening
Cover Seal rubber (NBR)
Terminal
Built-in switch
Separator
Rubber cap (CR)
Case
COM NC
NO
Operating
characteristics Model ZE-Q-2 XE-Q-2 ZE-Q22-2 XE-Q22-2 ZE-Q21-2 XE-Q21-2 ZE-QA2-2 XE-QA2-2
Operating force
Release force
Pretravel
Over Travel
Movement Differential
OF
RF min.
PT max.
OT min.
MD max.
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
Operating Position OP 38.2±0.8 mm 49.7±1 mm 49.7±1 mm ---
86
23
12R
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
* Stainless steel plunger
Plunger
ZE-Q-2
XE-Q-2
86
23
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
12.7 dia. × 4.8
* Stainless steel roller
Roller Plunger
ZE-Q22-2
XE-Q22-2
86
23
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
12.7 dia. × 4.8
* Stainless steel roller
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
86
23
17
PT
24
39.7
19
19.3
25.5
*2
*1
(23.1)
25.4±0.12
25.4±0.3
44±0.8
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
19.1 dia. × 7.9
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
5
ZE/ZV/ZV2/XE/XV/XV2
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
ZE-QA277-2 XE-QA277-2 ZE-N-2 XE-N-2 ZE-N22-2
OF max.
RF min.
PT max.
OT min.
MD max.
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
OP --- 45.8±0.8 mm 49.7±0.8 mm
ZE-N21-2 ZE-NA2-2 XE-NA2-2 ZE-NA277-2 XE-NA277-2
OF max.
RF min.
PT max.
OT min.
MD max.
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
OP 49.7±0.8 mm --- ---
86
23
17
24
39.7
19
19.3
25.5
PT
*2
*1
(40)
25.4±0.12
25.4±0.3
2.1±0.1
44±0.8
17.4R
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
18.7 dia. × 9
One-way Action Roller Arm Lever
ZE-QA277-2
XE-QA277-2
86
23
12R
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
* Stainless steel plunger
Sealed Plunger
ZE-N-2
XE-N-2
86
23
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
12.7 dia. × 4.8
* Stainless steel roller
Sealed Roller Plunger
ZE-N22-2
86
23
17
24
OP
19
25.5
PT
*
25.4±0.12
25.4±0.3
2.1±0.1
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
12.7 dia. × 4.8
* Stainless steel roller
Sealed Crossroller Plunger
ZE-N21-2
86
23
17
24
39.7
19
19.3
25.5
PT
*1
(23.1)
25.4±0.12
25.4±0.3
2.1±0.1
53.4±0.8
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
19.1 dia. × 7.9
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
86
23
*1
17
(40)
25.4±0.12
25.4±0.3 24
2.1±0.1
53.4±0.8
39.7
19
19.3
25.5
*2
17.4R
PT
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
18.7 dia. × 9
One-way Action Sealed Roller Arm Lever
ZE-NA277-2
XE-NA277-2
6
ZE/ZV/ZV2/XE/XV/XV2
Base Mounting/Diagonal Side Mounting Models
The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom.
The flange on base-mounted models is shown with dotted lines.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 ±0.8 mm.
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 ±1 mm.
3. OP for ZV2-Q21-2 and XV2-Q21-2 is 35.7 ±0.8 mm.
ZV-Q-2
ZV2-Q-2
XV-Q-2
XV2-Q-2
ZV-Q22-2
ZV2-Q22-2
XV-Q22-2
XV2-Q22-2
ZV-Q21-2
ZV2-Q21-2
XV-Q21-2
XV2-Q21-2
ZV-QA2-2
ZV2-QA2-2
XV-QA2-2
XV2-QA2-2
OF
RF min.
PT max.
OT min.
MD max.
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
OP 63.7±0.8 mm (see note 1)
(ZV-Q-2, XV-Q-2)
75.2±0.8 mm (see note 2)
(ZV-Q22-2, XV-Q21-2)
75.2±0.8 mm (see note 3)
(ZV-Q22-2, XV-Q21-2) ---
23
12R
17
3
OP
PT
86 5.5
54
53R
36.6
26.1
5
*1. Stainless steel plunger
*2. Only the ZV2-Q-2 and XV2-Q-2 incorporate
mounting holes.
t = 3 (ZV-Q-2/XV-Q-2 flange)
*2
(see note 1)
*1
41.3±0.2
10.5±0.3
25.4±0.3
31±0.2
75±0.2
JIS B0202 G1/2
Effective
thread: 4
threads min.
+0.2
0
Two, 5.4 dia.
holes
Two, 4.3±0.2 dia.
Plunger
ZV(2)-Q-2
XV(2)-Q-2
23
17
OP
PT
86
54
53R
36.6
26.1
3
5
5.5
*1. Stainless steel roller
*2. Only the ZV2-Q22-2 and XV2-Q22-2
incorporate mounting holes.
t = 3 (ZV-Q22-2/XV-Q22-2 flange)
*2
*1
25.4±0.3
41.3±0.2
10.5±0.3
31±0.2
75±0.2
JIS B0202 G1/2
Effective
thread: 4 threads min.
+0.2
0
Two, 5.4 dia.
holes
Two, 4.3±0.2 dia.
12.7 dia. × 4.8
(see note 2)
Roller Plunger
ZV(2)-Q22-2
XV(2)-Q22-2
23
17
OP
PT
86
54
53R
36.6
26.1
3
5
5.5
*1. Stainless steel roller
*2. Only the ZV2-Q21-2 and XV2-Q21-2 incorporate
mounting holes.
t = 3 (ZV-Q21-2/XV-Q21-2 flange)
*2
*1
25.4±0.3
41.3±0.2
10.5±0.3
31±0.2
75±0.2
JIS B0202 G1/2
Effective
thread: 4 threads min.
+0.2
0
Two, 5.4 dia.
holes
Two, 4.3±0.2 dia.
12.7 dia. × 4.8
(see note 3)
Crossroller Plunger
ZV(2)-Q21-2
XV(2)-Q21-2
23
17
39.7
19.3
*2
86 5.5
3
54
53R
36.6
PT
5
*3
*1
69.5±0.8
30±0.8
41.3±0.2
10.5±0.3
25.4±0.3
31±0.2
75±0.2
*1. Stainless sintered roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-QA2-2 and XV2-QA2-2 incorporate mounting holes.
JIS B0202
G1/2
Effective
thread: 4
threads min.
t = 3 (ZV-QA2-2/XV-QA2-2 flange)
+0.2
0
Two, 5.4 dia.
holes
Two, 4.3±0.2 dia.
19.1 dia. × 7.9
23.1 max.
Roller Arm Lever
ZV(2)-QA2-2
XV(2)-QA2-2
7
ZE/ZV/ZV2/XE/XV/XV2
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm.
2. OP for ZV2-N22-2 is 35.7 ±0.8 mm.
3. OP for ZV2-N21-2 is 35.7 ±0.8 mm.
ZV2-QA277-2 XV-QA277-2
XV2-QA277-2
ZV-N-2
ZV2-N-2
XV-N-2
XV2-N-2
ZV-N22-2
ZV2-N22-2
ZV-N21-2
ZV2-N21-2
OF max.
RF min.
PT max.
OT min.
MD max.
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
OP --- 71.4±0.8 mm (see note 1)
(ZV-N-2, XV-N-2)
75.2±0.8 mm
(see note 2)
(ZV-N22-2)
75.2±0.8 mm
(see note 3)
(ZV-N21-2)
23
17
39.7
R17.4
5.5
86
*2
*3
19.3
3
54
53R
36.6
5
PT
(40)
*1
69.5±0.8
30±0.8
41.3±0.2
10.6±0.3
25.4±0.3
31±0.2
75±0.2
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA277-2 and XV2-NA277-2
incorporate mounting holes.
JIS B0202 G1/2
Effective
thread: 4
threads min.
t=3 (ZV-NA277-2/XV-NA277-2 flanges)
18.7 dia. × 9 Two, 4.3±0.2 dia. holes
+0.2
0
Two, 5.4 dia.
holes
Operates in this
direction only
One-way Action Roller Arm Lever
ZV2-QA277-2
XV(2)-QA277-2
86 5.5
23
*1
*2
17
3
OP
5
PT
26.1
54
53R
36.6
41.3±0.2
10.6±0.3
25.4±0.3
31±0.2
75±0.2
JIS B0202 G1/2
Effective
thread: 4 threads min.
t = 3 (ZV-N-2/XV-N-2 flange)
Two, 4.3±0.2 dia. holes
+0.2
0
Two, 5.4 dia.
holes
*1. Stainless steel plunger
*2. Only the ZV2-N-2 and XV2-N-2 incorporate mounting holes.
12CR
(see note 1)
Sealed Plunger
ZV(2)-N-2
XV(2)-N-2
23
17
OP
PT
86
54
53R
36.6
26.1
3
5
5.5
*1
*2
25.4±0.3
31±0.2
75±0.2
10.6±0.3
41.3±0.2
JIS B0202
G1/2 Effective
thread: 4 threads min.
12.7 dia. × 4.8
Two, 4.3±0.2 dia. holes
+0.2
0
Two, 5.4 dia.
holes
t = 3 (ZV-N22-2 flange)
(see note 2)
*1. Stainless steel roller
*2. Only the ZV2-N22-2 incorporate mounting holes.
Sealed Roller Plunger
ZV(2)-N22-2
23
17
OP
PT
86
54
53R
36.6
26.1
5
3
5.5
*1
*2
41.3±0.2
10.6±0.3
25.4±0.3
31±0.2
75±0.2
JIS B0202 G1/2
Effective
thread: 4 threads min.
12.7 dia. × 4.8
Two, 4.3±0.2 dia. holes
+0.2
0
Two, 5.4 dia.
holes
(see note 3)
*1. Stainless steel roller
*2. Only the ZV2-N21-2 incorporate mounting holes.
t = 3 (ZV-N21-2 flange)
Sealed Crossroller Plunger
ZV(2)-N21-2
8
ZE/ZV/ZV2/XE/XV/XV2
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Be sure to protect part A with grease in order to maintain the
mechanical durability and performance of the Limit Switch. The use
of molybdenum disulfide grease is recommended.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
ZV-NA2-2
ZV2-NA2-2
XV-NA2-2
XV2-NA2-2
ZV-NA277-2
ZV2-NA277-2
XV-NA277-2
XV2-NA277-2
OF max.
RF min.
PT max.
OT min.
MD max.
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
Precautions for Correct Use
23
*3
*1
17
79±0.8
39.5±0.8
39.7 *2
5441.3±0.2
53R
36.6
10.6±0.3
86
75±0.2 5.5
19.3
(23.1)
25.4±0.3
3
PT
31±0.2
5
*1. Stainless sintered alloy roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes.
JIS B0202
G1/2
Effective
thread: 4
threads min.
t=3 (ZV-NA2-2/XV-NA2-2 flanges)
+0.2
0
Two, 5.4 dia.
holes
Two, 4.3±0.2 dia.
19.1 dia. × 9
Sealed Roller Arm Lever
ZV(2)-NA2-2
XV(2)-NA2-2
54
53R
36.6
23
17
39.7
*2
17.4R
86 5.5
5
19.3
(40)
3
PT
*3
*1
79±0.8
39.5±0.8
41.3±0.2
10.6±0.3
25.4±0.3
31±0.2
75±0.2
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA277-2 and XV2-NA277-2 incorporate
mounting holes.
JIS B0202
G1/2
Effective
thread: 4
threads min.
t=3 (ZV-NA277-2/XV-NA277-2 flanges)
18.7 dia. × 9
Operates in this
direction only
Two, 4.3±0.2 dia. holes
+0.2
0
Two, 5.4 dia.
holes
One-way Action Sealed Roller Arm Lever
ZV(2)-NA277-2
XV(2)-NA277-2
Not Suitable Suitable
9
ZE/ZV/ZV2/XE/XV/XV2
Mounting
With the Roller Lever-type Enclosed Switches, the roller arm has
been temporarily tightened prior to shipment, so that its position
may be adjusted later. When mounting the Switch, be sure to re-
tighten the roller arm so as to prevent it from becoming loose during
operation.
To adequately maintain the seals at the mounting screw section on
the side of the Enclosed Switch, insert each O-ring correctly and
secure it with the lock nut.
To provide the Switch with improved sealing property, use of the SC
Connector is recommended. Refer to Limit Switch Connectors for
details on SC Connectors.
When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch.
Appropriate Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
*1. This torque range applies to side mounting or bottom mounting. (M4 screws)
*2. This torque range applies to diagonal side mounting. (M5 Allen-head bolt)
Mounting
Mounting Holes
Operation
Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
precision of the Limit Switch. Make sure that the shape of the cam
is smooth enough.
Check that OT has a sufficient margin. The actual OT should be
rated OT x 0.7 to 1.
Dedicated Wrench
1. The roller arm can be set freely within a range of 225° after
loosening the nut.
2. The roller arm mounting bracket can be set in any direction after
loosening the nut.
Make sure that the nut is free of foreign substances when the nut is
loosened.
A dedicated wrench is provided separately.
No. Type Appropriate tightening torque
1Cover mounting screw 1.18 to 1.37 N·m
2Switch mounting screw*1 1.18 to 1.37 N·m
3Switch mounting screw*2 4.90 to 5.88 N·m
4Switch terminal screw
(M4 screws) 0.78 to 1.18 N·m
5Roller arm mounting nut 4.90 to 5.88 N·m
Model
SUPANA FOR ZE
75±0.1
31±0.1
41.3±0.15
25.4±0.1
Two, 4.3 dia.
mounting holes or
M4 screw holes
Two, 5.4 dia.
mounting holes or
M5 screw holes
Two, 4.3 dia.
mounting holes or
M4 screw holes
Side Mounting Bottom Mounting
Side Diagonal Mounting
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.