Accessories Y92@ CSM_Y92__DS_E_5_1 Mounting Brackets Special resin mounting sleeves: Four different models available. Simply select the size that fits the outside diameter of the Sensor. Mounting Bracket Dimensions A Item Dimension (mm) B Model E G F D C Y92E-B8 Y92E-B12 Y92E-B18 Y92E-B30 A B C D E 180.2 240.2 320.2 450.2 10 max. 12.5 max. 17 max. 17 max. 18 20 30 50 8 dia. 12 dia. 18 dia. 30 dia. 28 max. 37 max. 47 max. 60 max. F 6 6 7 10 Applied Applicable hexagonal Sensor G bolts diameter 7.4 dia. M4 x 20 M8 8 dia. M4 x 25 M12 9.8 dia. M5 x 32 M18 9.8 dia. M5 x 50 M30 Note: Consider the influence of surrounding metal when mounting non-shielded Sensors. (Refer to information on individual Sensors for dimensions.) Material: Mounting Bracket: Polyacetal Hexagonal bolt and spring washer: Nickel-plated iron Mounting Sleeves (Quick Mounting) Once the Mounting Sleeve and Sensor have been set properly, readjustment is not required when replacing the Sensor. Mounting Sleeve Dimensions Item Dimension (mm) A B C D Model A F E Material: Bracket: Nickel-plated iron Nut: Nickel-plated brass Mounting Sleeve: Polyacetal F Y92E-G8 Approx. 28 18.5 15.5 M12 x 1 17 4 Y92E-G12 Approx. 29 20.5 17.5 M18 x 1 24 4 Y92E-G18 Approx. 35 23.5 20.5 M24 x 1.5 30 5 Y92E-G30 Approx. 39 27.5 24.5 M36 x 1.5 41 5 B C D Two Mounting Sleeve clamping nuts E (between opposing faces) E (between opposing faces) E (between opposing faces) Distance across Sensor lock nut: E Applicable Sensors E2E/E2E2 M8 Shielded Sensors E2E/E2E2 M12 Shielded Sensors E2E/E2E2 M18 Shielded Sensors E2E/E2E2 M30 Shielded Sensors Note: Do not tighten the nut with excessive force. Do not exceed the torque in the following table. Item Mounting Sleeve clamping nuts Model Y92E-G8 18 N*m Y92E-G12 40 N*m Y92E-G18 70 N*m Y92E-G30 100 N*m Sensor lock nut 6 N*m 15 N*m 15 N*m 30 N*m 1 Y92@ Protective Covers [A Protective Cover cannot be used with a Capactive Proximity Sensor.] Covers are available to protect the Sensing Head. Simply select the size that fits the outside diameter of the Sensor. Protective Cover Dimensions Item Model Y92E-E12 Dimension (mm) A B 14 dia. 5 C +0.2 0.5 -0.1 Cover inner diameter (threaded) Material M12 x 1 M12 M18 x 1 M18 Shielded Models Y92E-E18 21 dia. 6 10.2 Y92E-E30 33 dia. 8 1.50.2 Y92E-E12M 14 dia. 12 0.5 -0.1 +0.2 M12 x 1 M30 Shielded Models Polyacetal resin M12 Unshielded Models Y92E-E18M 21 dia. 16 10.2 M18 x 1 M18 Unshielded Models Y92E-E30M 33 dia. 21 1.50.2 M30 x 1.5 M30 Unshielded Models Shielded Models M30 x 1.5 B C Applicable Sensor diameter A Sputter Protective Covers (Threaded on Inside of Cover) [A Sputter Protective Covers cannot be used with a Capactive Proximity Sensor.] The cover uses Fluororesin, so that chips that adhere due to sputtering can be easily removed. Sputter Protective Cover Dimensions D Item C Model A Y92E-E8-7 B A 10 dia. Dimension (mm) B C +0.2 D Applicable Sensor diameter M8 x 1 0.5 -0.1 5 M8 Shielded Models 5 M12 Shielded Models 6 8 M18 Shielded Models M30 Shielded Models Y92E-E12-7 14 dia. M12 x 1 +0.2 0.5 -0.1 Y92E-E18-7 Y92E-E30-7 21 dia. 33 dia. M18 x 1 M30 x 1.5 10.2 1.50.2 Note: Do not screw on too tightly, or the cap may be damaged. Sputter Protective Covers (Not Threaded on Inside of Cover) [A Sputter Protective Covers cannot be used with a Capactive Proximity Sensor.] Chips that adhere due to sputtering can be easily removed. Sputter Protective Cover Dimensions Item Model 1-dia. through hole Dimension (mm) A B C D Y92E-E12-2 11.0 dia. 14.0 dia. 5.0 1.0 Y92E-E18-2 17.0 dia. 7.0 3.0 Y92E-E30-2 28.5 dia. 33.0 dia. 8.0 6.0 21 dia. C0.5 A B Material Applicable Sensor diameter M12 Shielded Models Silicon rubber M18 Shielded Models M30 Shielded Models C0.5 C0.5 D C 2 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2010 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: Y92E-B12FRAS Y92E-B18FRAS Y92E-B30FRAS Y92E-E12 Y92E-E12-2 Y92E-E18 Y92E-E18M Y92E-E30 Y92E-G18 Y92E-SUMB-12 Y92E-WJ12X36IN Y92E-S08PVC4A2M-L Y92E-S08PVC4A5M-L Y92E-S08PVC4S2M-L