DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch General Description Features The AAT4601A SmartSwitch is a member of Skyworks' Application Specific Power MOSFETTM (ASPMTM) product family. It is a 1.8A current limited P-channel MOSFET power switch designed for high-side load switching applications. This switch operates with inputs ranging from 2.7V to 5.5V, making it ideal for both 3V and 5V systems. An integrated current-limiting circuit protects the input supply against large changes in load current which could cause the supply to fall out of regulation. The AAT4601A has protection from thermal overload which limits power dissipation and junction temperatures. The maximum current limit level will guarantee that 1.8A can be delivered to the load; the actual threshold is programmed with a resistor from the SET pin to ground. The quiescent supply current is typically 12A. In shutdown mode, the supply current decreases to less than 1A. * Input Voltage: 2.7V to 5.5V * Programmable Over-Current Threshold * Low Quiescent Current 12A Typical Less Than 1A with Switch Off * Only 2.5V Needed for ON Control * Thermal Shutdown * Fault Flag * 2ms Fault Blanking * Under-Voltage Lockout * Temperature Range: -40C to +85C * 4kV ESD rating * UL Approved--File No. E217765 * 8-Pin SOP or MSOP Package Applications The AAT4601A is available in a Pb-free, 8-pin SOP or MSOP package and is specified over the -40C to +85C temperature range. * * * * Hot Swap Supplies Notebook Computers Peripheral Ports USB Ports UL Recognized Component Typical Application INPUT 1 2 100k 8 ON 1F 3 IN IN OUT AAT4601A OUT FAULT SET ON GND OUTPUT 6 7 5 R SET 1F 4 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 1 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Pin Descriptions Pin # Symbol 1, 2 3 4 5 6, 7 IN ON GND SET OUT 8 FAULT Function These pins are the input to the P-channel MOSFET source. Connect a 1F capacitor from IN to GND. Active low enable input. A logic low turns the switch on. Ground. Current limit set input. A resistor from SET to ground sets the current limit for the switch. These pins are the P-channel MOSFET drain connection. Connect a 1F capacitor from OUT to GND. Fault indication output. This open-drain output goes low when in current limit or when the die temperature exceeds +135C, with a 2ms delay after the fault event occurs. Pin Configuration SOP-8 (Top View) FAULT IN 1 2 7 OUT IN 2 3 6 OUT ON 4 5 SET GND 1 IN 2 ON GND 8 FAULT 2 8 IN 1 1 2 MSOP-8 (Top View) 7 OUT 3 6 OUT 4 5 SET Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Absolute Maximum Ratings1 TA = 25C, unless otherwise noted. Symbol Description VIN VON, VFAULT VSET, VOUT IMAX TJ TLEAD VESD IN to GND ON, FAULT to GND SET, OUT to GND Maximum Continuous Switch Current Operating Junction Temperature Range Maximum Soldering Temperature (at Leads) ESD Rating--HBM2 Value Units -0.3 to 6 -0.3 to VIN + 0.3 -0.3 to VIN + 0.3 3 -40 to 150 300 4000 V V V A C C V Value Units Thermal Characteristics3 Symbol Description JA Maximum Thermal Resistance PD Maximum Power Dissipation SOP-8 MSOP-8 SOP-8 MSOP-8 100 150 1.25 833 C/W W mW 1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at conditions other than the operating conditions specified is not implied. 2. Human body model is a 100pF capacitor discharged through a 1.5k resistor into each pin. 3. Mounted on an FR4 printed circuit board. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 3 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Electrical Characteristics VIN = 5V, TA = -40C to +85C, unless otherwise noted. Typical values are TA = 25C. Symbol VIN IQ Description IQ(OFF) ISD(OFF) VUVLO Operation Voltage Quiescent Current Off-Supply Current Off-Switch Current Under-Voltage Lockout RDS(ON) On Resistance ILIM ILIM(MIN) OTMP VONL Current Limit Minimum Current Limit Shutdown Temperature ON Input Low Voltage VONH IONSINK VFAULTL IFSINK TRESP TBLANK TOFF TON ON Input High Voltage ON Input leakage FAULT Logic Output Low Voltage FAULT Logic Output High Leakage Current Limit Response Time Fault Blanking Time After Turn-On Turn-Off Time1 Turn-On Time1 Conditions Min Typ 2.7 VIN = 5V, ON = GND, IOUT = 0 ON = IN, VIN = 5.5V ON = IN, VIN = 5.5V, VOUT = 0 Rising Edge, 1% Hysteresis VIN = 5.0V VIN = 4.5V VIN = 3.0V VIN = 3.0V, TA = 25C RSET = 20.5k 2.0 750 VIN = 5V 12 0.004 0.07 2.3 70 75 80 80 1000 260 125 Max Units 5.5 30 1 15 2.7 120 130 150 110 1250 V A A A V 0.8 VIN = 2.7V to 3.6V VIN = 4.5V to 5.5V VON = 5.5V ISINK = 1mA VFAULT = 5.5V VIN = 5V 2.0 2.4 mA mA C V V 0.01 0.08 0.05 2 2 VIN = 5V VIN = 5V 1 0.4 1 20 200 1. Guaranteed by design. 4 m Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 A V A s ms s s DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Typical Characteristics Unless otherwise noted, VIN = 5V, TA = 25C. Quiescent Current 25 25 Input Current (A) Quiescent Current (A) Quiescent Current vs. Temperature 20 15 10 5 20 15 10 5 0 -40 -20 0 20 40 60 80 100 0 120 0 1 2 3 4 5 6 Temperature (C) Input Voltage (V) RSET ILIM Product vs. ILIM Current Limit (RSET = 20.5k ; VIN = 5.0V) 2500 1.0 2000 0.8 Product (V) Output Current (A) 1.2 0.6 0.4 1500 1000 0.2 500 0.0 0 1 2 3 4 5 0 0.5 1 Off-Supply Current vs. Temperature 2 Off-Switch Current vs. Temperature 10 10 Off-Switch Current (A) Off-Supply Current (A) 1.5 Typical ILIM (A) Output Voltage (V) 1 0.1 0.01 0.001 0.0001 -40 -20 0 20 40 60 80 Temperature (C) 100 120 140 1 0.1 0.01 0.001 0.0001 -40 -20 0 20 40 60 80 100 120 140 Temperature (C) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 5 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Typical Characteristics Unless otherwise noted, VIN = 5V, TA = 25C. Turn-On Time vs. Temperature Turn-Off Time vs. Temperature 80 2.0 Turn-Off Time (s) Turn-On Time (s) 1.8 VIN = 3V 70 60 50 40 VIN = 5V 30 20 10 VIN = 3V 1.6 1.4 VIN = 5V 1.2 1.0 0.8 0.6 0.4 0.2 0 0 -40 -20 0 20 40 60 80 100 120 -40 -20 0 Temperature (C) Switch Turn-On Time 80 100 120 Voltage (V) 4 ON 3 2 IOUT = ILIMIT 5 Output 1 0 4 ON 3 2 Output 1 0 -1 -10 0 40 60 -4 80 -2 0 Time (s) 4 4 2 0 Output Voltage 0 -4 4 Time (s) 6 6 8 9 8 Output Current 6 Input Voltage 6 3 4 0 2 Output Voltage 0 -20 0 20 40 60 80 100 120 Time (s) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 -3 140 Output Current (A) 8 Input Voltage Output Current (A) Output Current 6 Input and Output Voltage (V) 12 2 4 Short-Circuit Through 0.6 8 0 2 Time (s) Short-Circuit Through 0.3 Input and Output Voltage (V) 60 6 IOUT = ILIMIT -1 -20 6 40 Switch Turn-Off Time 6 5 Voltage (V) 20 Temperature (C) DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Typical Characteristics Unless otherwise noted, VIN = 5V, TA = 25C. Fault Delay vs. Temperature RDS(ON) vs. Temperature 100 90 2.0 RDS(ON) (m) Fault Delay (ms) 2.5 1.5 1.0 VIN = 3V 70 60 VIN = 4.5V 50 0.5 0 -40 80 40 -20 0 20 40 Temperature (C) 60 80 100 -4 0 -20 0 20 40 60 80 Temperature (C) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 7 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Functional Block Diagram IN OUT UnderVoltage Lockout Over-Temperature Protection FAULT ON 1.2V Reference Functional Description The AAT4601A is an integrated MOSFET load switch with an adjustable current limit, over-temperature protection, level-shifted input, and a fault flag. The current limit control is combined with an over-temperature thermal limit circuit to provide a comprehensive system to protect the load switch under short-circuit or other adverse operating conditions. The AAT4601A is ideally suited for control and protection of peripheral ports such as USB, RS232, and parallel ports. The current limit and over-temperature circuits will act independently. The device current limit is activated when the output load current exceeds an internal threshold level. The internal current limit threshold is determined by an external resistor connected between the SET pin and ground. The minimum current limit threshold is specified by ILIM(MIN). If the load switch ambient temperature becomes excessive or if a short-circuit condition persists, the die temperature will rise causing the overtemperature protection circuit to activate. 8 Current Limit SET If a current limit level less than ILIM(MIN) is required, the AAT4601A can be used to operate in foldback current limit mode. To achieve this, an RSET value can be chosen to program a current limit lower than ILIM(MIN); in this case, when the load current reaches ILIM(MIN), the current will immediately drop, limiting at the programmed value. If the current limit or over-temperature protection circuits are active for more than 2ms, the system will be informed via the FAULT flag. The 2ms delay allows the AAT4601A to be turned on into capacitive loads without activating the FAULT flag. The open drain FAULT output can be connected directly to system controllers driven by voltage levels less than the IN pin voltage without additional level shifting circuitry. The load switch is turned off by applying a logic high level to the ON pin. The AAT4601A typically consumes 12A when operating; when off, the device draws less than 1A. In the off state, current is prevented from flowing between the input and output. The ON function has logic level thresholds that allow the AAT4601A to be TTL compatible and may also be controlled by 2.5V to 5.0V CMOS circuits. The voltage level on either ON or FAULT should not exceed the input supply level present on the IN pin. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Applications Information Setting Current Limit A simple three-step procedure can be used to adjust the AAT4601A's current limit. First, the maximum current required by the load should be determined. Second, select a resistor that guarantees adequate current is available to the load under normal conditions. Finally, the maximum current that can pass through the switch can be calculated and compared to the maximum current available. Step 1: The maximum current required by a load is usually defined in port specifications design application references. For example, USB ports may be specified to support loads of up to 500mA. Step 2: The most convenient method for determining a current limit resistor value is to look it up in Table 1, "Current Limit RSET Values." Find the lowest current value that is greater than the maximum load current in the given application as listed in the column, "Device Will Not Current Limit Below." The resistor value needed is listed in the corresponding row in the column, "RSET." For example, a USB port requires 500mA. The lowest level where the device will current limit above 500mA is 507mA. The corresponding resistor value for RSET would be 33k. Step 3: Now the required resistor value has been determined. The maximum current that can be drawn, even with a short circuit applied to the output, can be determined by reading the column, "Device Always Current Limits Below." If the power supply connected to the AAT4601A's input can provide this current level, the power supply voltage will not collapse when a short circuit is applied to the load switch output. For example, a notebook computer has a USB port which is powered by an AAT4601A with a 33k resistor connected between the SET pin and GND. If the power supply connected to the AAT4601A's IN pin can provide more than 845mA, this supply will remain in regulation even if a short circuit is applied to the USB port. RSET (k) Current Limit Typ (mA) Device Will Not Current Limit Below (mA) Device Always Current Limits Below (mA) 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 2476 2277 2065 1895 1748 1633 1528 1353 1280 1158 1055 972 897 811 736 676 625 582 533 491 455 418 380 350 320 295 267 245 223 206 192 167 157 1857 1708 1549 1421 1311 1224 1146 1015 960 869 791 729 673 608 552 507 469 436 400 368 341 314 285 262 240 221 200 183 167 155 144 125 118 3095 2847 2581 2369 2185 2041 1910 1691 1600 1448 1318 1215 1122 1014 919 845 781 727 666 613 568 523 476 437 400 369 334 306 279 258 239 209 197 Table 1: Current Limit RSET Values. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 9 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Operation in Current Limit Eq. 1: TJ(MAX) = IMAX2 RDS(ON)(MAX) RJA + TA(MAX) If an excessive load is applied to the output of an AAT4601A, the load current will be limited by the device's current limit circuitry as shown in Figure 1, "Overload Operation." If a short circuit were to occur on the load, it would demand more current than allowed by the internal current limiting circuit and the voltage at the AAT4601A's output would drop. This causes the AAT4601A to dissipate more power than in normal operation, causing the die temperature to increase. When die temperature exceeds the internal over-temperature threshold, the AAT4601A will shut down. After shutting down, the AAT4601A cools to a level below the over-temperature threshold, at which point it will start up again. The AAT4601A will continue to cycle off and on until one of the following events occurs: the load current is reduced to a level below the AAT4601A's current limit setting; the input power is removed; or the output is turned off by a logic high level applied to the ON pin. Thermal Considerations Since the AAT4601A has internal current limit and overtemperature protection, junction temperature is rarely a concern. If an application requires a large load current in a high-temperature operating environment, there is the possibility that the over-temperature protection circuit, rather than the current limit circuit, will regulate the current available to the load. In these applications, the maximum current available without risk of activation of the over-temperature circuit can be calculated. The maximum internal temperature while current limit is not active can be calculated using Equation 1: In Equation 1, IMAX is the maximum current required by the load. RDS(ON)(MAX) is the maximum rated RDS(ON) of the AAT4601A at high temperature. RJA is the thermal resistance between the AAT4601A's die and the board onto which it is mounted. TA(MAX) is the maximum ambient temperature for the printed circuit board assembly under the AAT4601A when the load switch is not dissipating power. Equation 1 can be transformed to provide IMAX; refer to Equation 2: Eq. 2: IMAX = TSD(MIN) - TA(MAX) RDS(ON)(MAX) RJA TSD(MIN) is the minimum temperature required to activate the AAT4601A's over-temperature protection. With a typical specification of 125C, 115C is a safe minimum value to use. For example, a portable device is specified to operate in a 50C environment. The printed circuit board assembly will operate at temperatures as high as 85C. This portable device has a sealed case and the area of the printed circuit board assembly is relatively small, causing RJA to be approximately 120C/W. Using Equation 2: Eq. 3: IMAX = 115C - 85C = 1.4A 0.13 * 120C/W If this system requires less than 1.4A, the thermal limit will not activate during normal operation. 6 5 Input Voltage Voltage (V) 4 1 is Applied to Output at t = 0 RSET is 33k 3 2 Output Voltage 1 0 -0.5 0 0.5 1 1.5 Time (s) Figure 1: Overload Operation. 10 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 2 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Input Capacitor The input capacitor serves two purposes. First, it protects the source power supply from transient current effects generated by the application load circuit. If a short circuit is suddenly applied to the output of an AAT4601A, there is a microsecond-long period during which a large current can flow before the current limit circuitry activates; refer to the characteristic curve, "Short-Circuit Through 0.3." A properly sized input capacitor can dramatically reduce the load switch input transient response effects seen by the power supply and other circuitry upstream from the AAT4601A. The second purpose of the input capacitor is to prevent transient events generated by the load circuit from affecting operation of the AAT4601A. For example, if an AAT4601A is used in a circuit that operates from a 3V power supply with poor step load response, it is possible that turning on the load switch could cause the input power supply to droop below the AAT4601A's undervoltage lockout threshold. This drop in voltage would cause the AAT4601A to turn off until the input power supply's voltage recovers. Since this cycle would be selfperpetuating, the entire circuit could be seen to be unstable. In the very rare case where capacitor cost is prohibitive, the output load circuit should be slew rate limited when turned on. Output Capacitor In order to insure stability while the device current limit is active, a small capacitance of approximately 1F should be used. When the AAT4601A is activated using the ON function, there are no momentary current transients, as in the case when a short circuit is suddenly applied to a device that is already on; refer to the characteristic curve, "Switch Turn-On Time." No matter how big the output capacitor, output current is limited to the value allowed by the threshold determined by RSET and the internal current limiting circuitry. This permits very large output capacitors to be used. For example, USB ports are specified to have at least 120F of downstream capacitance from their controlling power switch. An output capacitance as large as 1000F would not disturb the input power supply to the AAT4601A used to control the USB port. ON Input tion is reduced to less than 1A. The ON threshold voltage is set to allow the AAT4601A to be controlled by 5V TTL levels as well as CMOS power from 2.5V to 5V. The ON function control voltage level should not exceed the input supply level applied to the IN pin. FAULT Output A FAULT flag is provided to alert a system if the load switch is not receiving a sufficient voltage level to properly operate. If either the current limit or over-temperature circuits in any combination are continuously active for more than approximately 2ms, the FAULT pin is pulled to ground internally through a 100 resistance. The 2ms delay on the FAULT function is intended to prevent capacitive loads connected to the load switch output from activating FAULT when the device is turned on. The placement of a pull-up resistor between the FAULT pin and the IN pin is recommended. Reasonable values for the pull-up resistor should range from 10k to 100k. Since FAULT is an open drain terminal, it may be pulled up to any voltage that is not greater than the level present on the IN pin. This is done to allow the AAT4601A to signal ancillary circuitry that is powered by a voltage level less than the level on the IN pin. Reverse Voltage The AAT4601A is designed to control current flowing from IN to OUT. If a voltage is applied to OUT that is greater than that on IN, a large resulting reverse current may flow, potentially damaging the AAT4601A. Printed Circuit Board Layout Recommendations For proper thermal management, and to take advantage of the low RDS(ON) of the AAT4601A, a few circuit board layout rules should be followed: VIN and VOUT should be routed using wider than normal traces, and GND should be connected to a ground plane. For best performance, CIN and COUT should be placed close to the package pins. Evaluation Board Layout The AAT4601A evaluation layout follows the printed circuit board layout recommendations and can be used for good applications layout. Note: Board layout shown is not to scale. When the AAT4601A is in the off state, the output is an open circuit and the device quiecent current consump- Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 11 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Figure 1: AAT4601A Evaluation Board Top Side Silk Screen Assembly Drawing. Figure 2: AAT4601A Evaluation Board Component Side Layout. Figure 3: AAT4601A Evaluation Board Solder Side Layout. 12 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch Ordering Information Package Marking1 Part Number (Tape and Reel)2 SOP-8 MSOP-8 4601A MQXYY AAT4601AIAS-T1 AAT4601AIKS-T1 Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04-0074. Package Information 6.00 0.20 3.90 0.10 SOP-8 4.90 0.10 0.42 0.09 x 8 1.27 BSC 45 4 4 0.175 0.075 1.55 0.20 0.375 0.125 0.235 0.045 0.825 0.445 All dimensions in millimeters. 1. XYY = assembly and date code. 2. Sample stock is generally held on part numbers listed in BOLD. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012 13 DATA SHEET AAT4601A 1.8A Current Limited P-Channel Switch MSOP-8 4 4 4.90 0.10 3.00 0.10 1.95 BSC 0.95 REF 0.60 0.20 PIN 1 3.00 0.10 0.85 0.10 0.95 0.15 10 5 GAUGE PLANE 0.254 BSC 0.155 0.075 0.075 0.075 0.65 BSC 0.30 0.08 All dimensions in millimeters. Copyright (c) 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. ("Skyworks") products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and "Breakthrough Simplicity" are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. 14 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201914A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 3, 2012