Description
The RP08-AW series wide range input DC/DC converters are certified to UL60950-1 and cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved safety standards are
required. The 24V and 110VDC input versions have been especially designed for railway applications.
The DIP24 package is available in both pinned and SMD case styles and meets military standards for
thermal shock and vibration tolerance.
RP08-AW
DC/DC Converter
E196683
UL60950-1 certified
EN50155 certified
www.recom-power.com REV.: 6/2018 PD-1
8 Watt
DIP24/SMD
Single and Dual
Output
Features
Regulated
Converter
4:1 Wide input voltage range
1.6kVDC isolation
UL60950-1, EN50155 certified
Efficiency up to 88%
Protected outputs
High input voltage range (110VDC)
Selection Guide
Part Number Input Output Output Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current typ. Load(2)
[VDC] [VDC] [mA] [mA] [%] [µF]
RP08-243.3SAW(3) 9-36 3.3 2400 388 85 1330
RP08-2405SAW(3) 9-36 5 1600 383 87 1330
RP08-2412SAW(3) 9-36 12 666 387 86 288
RP08-2415SAW(3) 9-36 15 533 387 86 200
RP08-483.3SAW(3) 18-75 3.3 2400 194 85 1330
RP08-4805SAW(3) 18-75 5 1600 192 87 1330
RP08-4812SAW(3) 18-75 12 666 191 87 288
RP08-4815SAW(3) 18-75 15 533 189 88 200
RP08-1103.3SAW(3) 43-160 3.3 2400 86 84 1330
RP08-11005SAW(3) 43-160 5 1600 86 85 1330
RP08-11012SAW(3) 43-160 12 666 84 86 288
RP08-11015SAW(3) 43-160 15 533 85 86 200
RP08-2405DAW(3) 9-36 ±5 ±800 397 84 ±900
RP08-2412DAW(3) 9-36 ±12 ±333 387 86 ±133
RP08-2415DAW(3) 9-36 ±15 ±267 388 86 ±90
RP08-4805DAW(3) 18-75 ±5 ±800 198 84 ±900
RP08-4812DAW(3) 18-75 ±12 ±333 191 87 ±133
RP08-4815DAW(3) 18-75 ±15 ±267 192 87 ±90
RP08-11005DAW(3) 43-160 ±5 ±800 89 82 ±900
RP08-11012DAW(3) 43-160 ±12 ±333 85 85 ±133
RP08-11015DAW(3) 43-160 ±15 ±267 86 85 ±90
Input Voltage
Output Voltage
Single or Dual
Package (3)
RP08-__ __ _AW/_
Model Numbering
Ordering Examples
RP08-4805AW/SMD = 48V Input, 5V Output, SMD Package
RP08-2405AW = 24V Input, 5V Output, DIP24 Package
Notes:
Note3: No suffix for standard package (DIP24), add suffix “SMD” for SMD package
Notes:
Note1: Maximum value at nominal input voltage and full load
Note2: Max Cap Load is tested at minimum Vin and constant resistive load
https://www.recom-power.com/pdf/
Powerline_DC-DC/RSPxxx-168.pdf
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-2
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Filter Pi-Type
Input Voltage Range
nom. Vin = 24V
nom. Vin = 48V
nom. Vin = 110V
9VDVC
18VDC
43VDC
24VDC
48VDC
110VDC
36VDC
75VDC
160VDC
Input Surge Voltage 100ms max.
Vin = 24V
Vin = 48V
Vin = 110V
50VDC
100VDC
170VDC
Under Voltage Lockout (UVLO)
Vin= 24V DC-DC ON
DC-DC OFF 8VDC
9VDC
Vin= 48V DC-DC ON
DC-DC OFF 16VDC
18VDC
Vin=110V DC-DC ON
DC-DC OFF 40VDC
43VDC
Input reflected Ripple Current 20mAp-p
Start-up time Power up
ON/OFF CTRL
450ms
5ms
Operating Frequency Range 270kHz 300kHz 330kHz
Minimum Load 0%
ON/OFF CTRL (4) Positive Logic DC-DC ON
DC-DC OFF
Open or 3.0 < Vr < 12VDC
Short or 0 < Vr < 1.2VDC
Input current of Remote pin (CTRL) DC-DC ON -0.5mA +0.5mA
Standby Current DC-DC OFF 2.5mA
Ripple and Noise 20MHz bandwidth Vin = 24V, 48V
Vin = 110V
50mVp-p
75mVp-p
continued on next page
Notes:
Note4: The ON/OFF control pin voltage is referenced to -Vin pin
Efficiency vs. Output Current Efficiency vs. Input Voltage
Efficiency [%]
Input Voltage [VDC]
9
65
70
75
80
85
95
15 18 24 30 3612 21 27 33
90
Efficiency [%]
Output Current [%]
10
65
55
50
45
40
70
75
80
85
95
20 40 60 80 10030 50 70 90
90
9Vin
24Vin
36Vin
RP08-2405SAW
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-3
REGULATIONS
Parameter Condition Value
Output Voltage Accuracy ±1.0%
Line Voltage Regulation low line to high line, full load ±0.2%
Load Voltage Regulation
no load to full load DIP24 Single
Dual
±0.5%
±1.0%
SMD Single, Dual
±1.0%
10% load to 90% load DIP24 Single
Dual
±0.3%
±0.8%
SMD Single, Dual ±0.8%
Cross Regulation asymmetrical 25%<>100% load ±5.0%
Transient Response recovery time 25% load step change 250μs typ.
Efficiency vs. Output Current
Efficiency vs. Output Current
Efficiency vs. Input Voltage
Efficiency vs. Input Voltage
Efficiency [%]
Input Voltage [VDC]
18
65
70
75
80
85
95
30 36 48 60 757224 42 54 66
90
Efficiency [%]
Input Voltage [VDC]
43
60
65
70
75
80
90
67 79 103 139 16055 91 127115 151
85
18Vin
48Vin
75Vin
Efficiency [%]
Output Current [%]
10
60
55
50
45
40
65
70
75
80
95
90
20 40 60 80 10030 50 70 90
85
43Vin
110Vin
160Vin
Efficiency [%]
Output Current [%]
10
60
55
50
40
45
65
70
75
80
90
95
20 40 60 80 10030 50 70 90
85
RP08-11005SAW
RP08-4805SAW
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-4
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range (6) without derating
with derating
-40°C to +85°C
-40°C to +105°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance natural convection (20LFM, 0.1m/s) 20°C/Watt
Operating Altitude 4000m
Operating Humidity non-condensing 5% - 95% RH
Pullution Degree PD2
Shock MIL-STD-810F
Thermal Shock MIL-STD-810F
Vibration MIL-STD-810F
Fire protection on railway vehicles according to EN45545-2:2013 standard
MTBF (7) MIL-HDBK-217F
Bellcore-TR-NWT-000332
2832 x 103 hours
2350 x 103 hours
-40 60 85
10040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
120
105
80
Derating Graph (8) RP08-4805SAW
Notes:
Note6: Converter can meet the railway T2 and TX temperature requirement
Note7: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground Benign and controlled environment)
MIL-HDBK-217F, Notice 2, Full Load, 25°C, Ground Benign
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a partnumber not shown
here please contact our technical support service at techsupportAT@recom-power.com
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Single Output
3.3Vout
5Vout
12Vout
15Vout
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
Over Load Protection (OLP) % of Iout rated 150% typ.
Isolation Voltage
DIP24 I/P to O/P, I/P (O/P) to case 1.6kVDC/1 minute
SMD I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.0kVDC/1 minute
Isolation Resistance 500VDC 1G min.
Isolation Capacitance 1500pF max.
Insulation Grade functional
Notes:
Note5: This power module is not internally fused. An input line fuse must always be used
Recom suggests: 24Vin=T2A; 48Vin=T1A; 110Vin=T0.5A slow blow
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-5
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E196683 UL60950-1, 2nd Edition, 2014
C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
(LVD) TW1708010-001 IEC60950-1:2005, 2nd Edition +A2:2013
EN60950-1:2006 + A2:2013
RoHS2+ RoHS-2011/65/EU + AM-2015/863
Railways Condition Standard / Criterion
Railway Applications - Electrical Equipment used on rolling stock 15A100701E-C EN50155:2007
Environmental testing Part 2-1: Tests – Test A: Cold temperature: -25°C, Dwell Time: 2 hours EN60068-2-1:2007
Environmental testing Part 2-2: Tests – Test B: Dry heat temperature: +70°C, Dwell Time: 6 hours EN60068-2-2:2007
Environmental testing Part 2-30: Tests - Test Db: Damp heat,
cyclic (12 h + 12 h cycle)
temperature: +25 to +55°C
humidity: 90% to 100%RH
test Duration: 24 hours/cycle, 2 cycles
EN60068-2-30:2005
Railway applications - Fire protection on railway vehicles Part2:
Requirements for fire behaviour of materials and components EN45545-2:2013
Fire hazard testing Part 2-11: Glowing/hot-wire based testmethods –
Glow-wire flammability test method for end-products glow-wire test EN60695-2-11
Fire hazard testing Part 11-10: Test flames – 50 W horizontal and
vertical flame test methods vertical flame test EN60695-11-10
EMC Compliance Railway Condition Standard / Criterion
Railway applications - Electromagnetic compatibility EN50121-3-2:2006
Industrial, scientific and medical equipment – Radio frequency
disturbance characteristics – Limits and methods of measurement EN55011
ESD Electrostatic discharge immunity test Air ±2, 4,8kV, Contact ±2, 4, 6kV EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
20V/m (80-1000MHz)
10V/m (1400-2100MHz)
5V/m (2100-2500MHz)
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity DC Power Port: ±2kV EN61000-4-4, Criteria A
Surge Immunity DC Power Port: Line-Line ±0.5, 1kV
DC Power Port: Line-Earth ±0.5, 1.2kV EN61000-4-5, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port 10V EN61000-4-6, Criteria A
EMC Compliance Multimedia and IT Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment –Emission
Requirements EN55032:2015+AC:2016-07, Class B
Information technology equipment - Immunity characteristics - Limits
and methods of measurement EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air ±2, 4, 8kV, Contact ±2, 4, 6kV IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 20V/m (80-1000MHz) IEC61000-4-3:2006+A1:2007 + A2:2010,
Criteria A
Fast Transient and Burst Immunity DC Power Port: ±2kV IEC61000-4-4:2012, Criteria A
Surge Immunity DC Power Port: ±2kV IEC61000-4-5:2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port 10V IEC61000-4-6:2013, Criteria A
Power Magnetic Field Immunity 50Hz 100A 1 minute
50Hz 1000A 1 second IEC61000-4-8:2009, Criteria A
Notes:
Note9: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below on next page
Note10: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 24Vin, 48Vin=220μF/100V or 110Vin=150μF/200V
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-6
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
base
potting
nickel coated copper
non-conductive black plastic (UL94-V2)
epoxy (UL94-V0)
Package Dimensions (LxWxH) DIP
SMD
31.8 x 20.3 x 10.2mm
32.0 x 20.3 x 11.2mm
Package Weight DIP
SMD
18g
20g
continued on next page
EMI Filtering Class A
Single
Single
Dual
Dual
Input
Input
Fuse
C1
+VIN
+VOUT
-VOUT
-VIN
LOAD
C3
C2
C2
Fuse
C1
+VIN
+VOUT
COM
-VOUT
-VIN
LOADLOAD
C3
Input
Input
Fuse
C1
+VIN
+VOUT
-VOUT
-VIN
LOAD
C3
C2
C2
Fuse
C1
+VIN
+VOUT
COM
-VOUT
-VIN
LOADLOAD
C3
MODEL C1 C2 C3
RP08-24xxS_DW
RP08-24xxS_DW/SMD 1.0μF/50V, 1210MLCC N/A 1000pF/2kV, 1206 MLCC
RP08-48xxS_DW
RP08-48xxS_DW/SMD 0.47μF/100V, 1810MLCC N/A 1000pF/2kV, 1206 MLCC
RP08-110xxS_DW
RP08-110xxS_DW/SMD
1μF/250V, 1812 MLCC 1μF/250V, 1812 MLCC 1000pF/2kV, 1206 MLCC
EMI Filtering Class B
Input
Fuse
C2C1
+VIN
+VOUT
-VOUT
-VIN
LOAD
C4
C3
L1
Input
+VOUT
COM
-VOUT
LOADLOAD
Fuse
C2C1
+VIN
+VOUT
-VOUT
-VIN
L1
MODEL C1 C2 C3/C4 L1
RP08-24xxS_DW
RP08-24xxS_DW/SMD 4.7μF/50V, 1812 MLCC N/A 1000pF/2kV, 1206 MLCC CMC: 325μH
ref.: WE 744290321 or CMC-06
RP08-48xxS_DW
RP08-48xxS_DW/SMD 1.5μF/100V, 1812 MLCC 1.5μF/100V, 1812 MLCC 1000pF/2kV, 1206 MLCC CMC: 325μH
ref.: WE 744290321 or CMC-06
RP08-110xxS_DW
RP08-110xxS_DW/SMD 1μF/250V, 1812 MLCC N/A 1000pF/2kV, 1206 MLCC CMC: 497μH
ref.: WE 7448013501
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-7
10.9
11.2
2.54
0.50±0.1 1.50
2.00
32.0
10.16
20.3
11 x 2.54 = 27.94
25.4
2 6.4
2.54
1 4 5 9 10 11 1232
24 21 20
Bottom View Top View
16 15 14 132223 1 4 5 9 10 11 1232
24 21 20 16 15 14 132223
DIP24 Dimension Drawing (mm)
Pin Connections DIP24
Pin # Single Dual
1 Ctrl Ctrl
2 -Vin -Vin
3 -Vin -Vin
9 NC Com
11 NC -Vout
14 +Vout +Vout
16 -Vout Com
22 +Vin +Vin
23 +Vin +Vin
NC = No Connection
Pin Pitch Tolerance ±0.25mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
SMD Dimension Drawing (mm)
20.3
3.8
10.2
31.8
Ø0.5±0.1
Ø0.8+0.15/-0
2.54
2.54
8 x 2.54= 20.32
2.0 2.5
23
Bottom View Top View
911
23 22 16 14
23 22 16 14
1
239111
5.08
15.24
2.54
10 x 2.54= 25.40
Pin Connections SMD
Pin # Single Dual
1 Ctrl Ctrl
2 -Vin -Vin
3 -Vin -Vin
9 NC Com
11 NC -Vout
14 +Vout +Vout
16 -Vout Com
22 +Vin +Vin
23 +Vin +Vin
Others NC NC
NC = No Connection
Pin Pitch Tolerance ±0.25mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
Recommended Footprint Details
Recommended Footprint Details
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-8
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH) Tube DIP24
SMD
255.0 x 23.0 x 19.0mm
255.0 x 32.0 x 16.0mm
Packaging Quantity DIP24, SMD 7pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 5% - 95% RH