AQ-R
Discontinued as of August 31, 2011
1
ds_61608_en_aqr: 010611D
TYPES
1. Plug-in terminal type
2. Screw-terminal type
10A to 40A
hockey puck type
AQ-R RELAYS
Type Load voltage Input voltage Standard (1,500V AC) Reinforced (4,000V AC)
Part No. Part No.
Zero-cross 10 A
75 to 125V AC 4 to 6V DC AQR10A1-Z4/6VDC
10 to 18V DC AQR10A1-Z10/18VDC
18 to 28V DC AQR10A1-Z18/28VDC
75 to 250V AC 4 to 6V DC AQR10A2-Z4/6VDC AQR10A2-ZV4/6VDC
10 to 18V DC AQR10A2-Z10/18VDC AQR10A2-ZV10/18VDC
18 to 28V DC AQR10A2-Z18/28VDC AQR10A2-ZV18/28VDC
Zero-cross 15 A
75 to 125 V AC 4 to 6V DC AQR15A1-Z4/6VDC
10 to 18V DC AQR15A1-Z10/18VDC
18 to 28V DC AQR15A1-Z18/28VDC
75 to 250 V AC 4 to 6V DC AQR15A2-Z4/6VDC AQR15A2-ZV4/6VDC
10 to 18V DC AQR15A2-Z10/18VDC AQR15A2-ZV10/18VDC
18 to 28V DC AQR15A2-Z18/28VDC AQR15A2-ZV18/28VDC
Zero-cross 20 A
75 to 125 V AC 4 to 6V DC AQR20A1-Z4/6VDC
10 to 18V DC AQR20A1-Z10/18VDC
18 to 28V DC AQR20A1-Z18/28VDC
75 to 250 V AC 4 to 6V DC AQR20A2-Z4/6VDC AQR20A2-ZV4/6VDC
10 to 18V DC AQR20A2-Z10/18VDC AQR20A2-ZV10/18VDC
18 to 28V DC AQR20A2-Z18/28VDC AQR20A2-ZV18/28VDC
Type Load voltage Input voltage Standard (1,500V AC) Reinforced (4,000V AC)
Part No. Part No.
Zero-cross 10 A
75 to 125 V AC 4 to 6V DC AQR10A1-S-Z4/6VDC
10 to 18V DC AQR10A1-S-Z10/18VDC
18 to 28V DC AQR10A1-S-Z18/28VDC
75 to 250 V AC 4 to 6V DC AQR10A2-S-Z4/6VDC AQR10A2-S-ZV4/6VDC
10 to 18V DC AQR10A2-S-Z10/18VDC AQR10A2-S-ZV10/18VDC
18 to 28V DC AQR10A2-S-Z18/28VDC AQR10A2-S-ZV18/28VDC
Zero-cross 15 A
75 to 125 V AC 4 to 6V DC AQR15A1-S-Z4/6VDC
10 to 18V DC AQR15A1-S-Z10/18VDC
18 to 28V DC AQR15A1-S-Z18/28VDC
75 to 250 V AC 4 to 6V DC AQR15A2-S-Z4/6VDC AQR15A2-S-ZV4/6VDC
10 to 18V DC AQR15A2-S-Z10/18VDC AQR15A2-S-ZV10/18VDC
18 to 28V DC AQR15A2-S-Z18/28VDC AQR15A2-S-ZV18/28VDC
Zero-cross 20 A
75 to 125 V AC 4 to 6V DC AQR20A1-S-Z4/6VDC
10 to 18V DC AQR20A1-S-Z10/18VDC
18 to 28V DC AQR20A1-S-Z18/28VDC
75 to 250 V AC 4 to 6V DC AQR20A2-S-Z4/6VDC AQR20A2-S-ZV4/6VDC
10 to 18V DC AQR20A2-S-Z10/18VDC AQR20A2-S-ZV10/18VDC
18 to 28V DC AQR20A2-S-Z18/28VDC AQR20A2-S-ZV18/28VDC
Zero-cross 30 A 75 to 250 V AC 4 to 6V DC AQR30A2-S-Z4/6VDC
10 to 18V DC AQR30A2-S-Z10/18VDC
18 to 28V DC AQR30A2-S-Z18/28VDC
Zero-cross 40 A 75 to 250 V AC 4 to 6V DC AQR40A2-S-Z4/6VDC
10 to 18V DC AQR40A2-S-Z10/18VDC
18 to 28V DC AQR40A2-S-Z18/28VDC
(10A, 15A, 20A type) (30A, 40A type)
Discontinued as of August 31, 2011
Product is discontinued.
FEATURES
1. Two types of terminal shape: Plug-
in terminal and Screw terminal (30 A,
40 A is screw terminal types only)
2. Flat type of SSR possible by
aluminium printed circuit board
3. High dielectric strength of 1,500 V
between input and output. 4,000 V
available for 10A, 15A, 20A devices.
4. Heat sink and DIN mounting rail and
terminal cover are available as
accessories
APPLICATIONS
1. Molding machine (heater control)
2. Temperature controlled bath (heater
control)
3. Printing machine (heater control)
4. Machine tool (motor control)
AQ-R
AQ-R Discontinued as of August 31, 2011
2ds_61608_en_aqr: 010611D
ORDERING INFORMATION
SPECIFICATIONS
10AEx. AQR 1 S Z 4/6VDC
Load current
10 A, 15 A, 20 A, 30 A, 40 A 1: 75 to 125 V AC
2: 75 to 250 V AC
Nil: Plug-in terminal
S: Screw terminal
Z: Zero-cross type (1,500 V)
ZV: Zero-cross type (4,000 V)
4/6, 10/18, 18/28 V DC
Load voltage Terminal shape Type Input voltage
Note: Standard packing: Carton 10 pcs., Case: 100 pcs.
1. Ratings (at 20C 68F, Input ripple: 1% or less)
1) 10 A type
2) 15 A type
Part No. AQR10A1-Z4/
6VDC AQR10A1-Z10/
18VDC AQR10A1-Z18/
28VDC
AQR10A2-Z4/
6VDC
AQR10A2-ZV4/
6VDC
AQR10A2-Z10/
18VDC
AQR10A2-ZV10/
18VDC
AQR10A2-Z18/
28VDC
AQR10A2-ZV18/
28VDC Remarks
Items
AQR10A1-S-Z4/
6VDC AQR10A1-S-Z10/
18VDC AQR10A1-S-Z18/
28VDC
AQR10A2-S-Z4/
6VDC
AQR10A2-S-ZV4/
6VDC
AQR10A2-S-Z10/
18VDC
AQR10A2-S-
ZV10/18VDC
AQR10A2-S-Z18/
28VDC
AQR10A2-S-
ZV18/28VDC
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 10 A See
“REFERENCE
DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 100 A In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA
OFF-state dV/dt 100 V/s
Part No. AQR15A1-Z4/
6VDC AQR15A1-Z10/
18VDC AQR15A1-Z18/
28VDC
AQR15A2-Z4/
6VDC
AQR15A2-ZV4/
6VDC
AQR15A2-Z10/
18VDC
AQR15A2-ZV10/
18VDC
AQR15A2-Z18/
28VDC
AQR15A2-ZV18/
28VDC Remarks
Items
AQR15A1-S-Z4/
6VDC AQR15A1-S-Z10/
18VDC AQR15A1-S-Z18/
28VDC
AQR15A2-S-Z4/
6VDC
AQR15A2-S-ZV4/
6VDC
AQR15A2-S-Z10/
18VDC
AQR15A2-S-
ZV10/18VDC
AQR15A2-S-Z18/
28VDC
AQR15A2-S-
ZV18/28VDC
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 15 A See
“REFERENCE
DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 150 A In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA
OFF-state dV/dt 100 V/s
AQ-R
Discontinued as of August 31, 2011
3
ds_61608_en_aqr: 010611D
3) 20 A type
4) 30 A type and 40 A type
2. Characteristics (at 20C 68F, Input ripple: 1% or less)
Note: * 30 A and 40 A type is 10 to 55 Hz at double amplitude of 1.5 mm.
Part No. AQR20A1-Z4/
6VDC AQR20A1-Z10/
18VDC AQR20A1-Z18/
28VDC
AQR20A2-Z4/
6VDC
AQR20A2-ZV4/
6VDC
AQR20A2-Z10/
18VDC
AQR20A2-ZV10/
18VDC
AQR20A2-Z18/
28VDC
AQR20A2-ZV18/
28VDC Remarks
Items
AQR20A1-S-Z4/
6VDC AQR20A1-S-Z10/
18VDC AQR20A1-S-Z18/
28VDC
AQR20A2-S-Z4/
6VDC
AQR20A2-S-ZV4/
6VDC
AQR20A2-S-Z10/
18VDC
AQR20A2-S-
ZV10/18VDC
AQR20A2-S-Z18/
28VDC
AQR20A2-S-
ZV18/28VDC
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 20 A See
“REFERENCE
DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency 45 to 65 Hz
Repetitive peak
voltage 400 V 600 V
Non-repetitive
surge current 200 A In one cycle at
60 Hz
Max. “OFF-state”
leakage current 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 100 mA
OFF-state dV/dt 100 V/s
Part No.
Items AQR30A2-S-Z4/
6VDC AQR30A2-S-Z10/
18VDC AQR30A2-S-Z18/
28VDC AQR40A2-S-Z4/
6VDC AQR40A2-S-Z10/
18VDC AQR40A2-S-Z18/
28VDC Remarks
Input
side
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k Approx. 0.26 k Approx. 0.86 k Approx. 1.36 k
Drop-out voltage,
min. 1 V
Load
side
Max. load current 30 A 40 A See
“REFERENCE
DATA 1”
Load voltage 75 to 250 V AC
Frequency 45 to 65 Hz
Non-repetitive
surge current 300 A 400 A In one cycle at
60 Hz
Max. “OFF-state”
leakage current 5 mA (when 200 V AC applied) at 60 Hz
Max. “ON-state”
voltage drop 1.6 V at max.
carrying current
Min. load current 120 mA
Type Zero-cross type Remarks
Item Standard type Reinforced type
Operate time, max. (1/2 cycle of voltage sine wave) + 1 ms
Release time, max. (1/2 cycle of voltage sine wave) + 1 ms
Insulation resistance, min., Initial 100 M between input, output and case by 500V DC megger
Breakdown voltage 1,500 V AC between input, output and case 4,000 V AC between input, output and case For 1 min.
Vibration
resistance Functional 10 to 55 Hz at double amplitude of 2 mm* 1 hour for X, Y, Z axes
Destructive 10 to 55 Hz at double amplitude of 2 mm* 10 minutes for X, Y, Z axes
Shock
resistance Functional Min. 980 m/s2 {100 G} 5 time each for X, Y, Z axes
Destructive Min. 980 m/s2 {100 G} 4 time each for X, Y, Z axes
Ambient temperature –20C to +80C –4F to +176F
Storage temperature –25C to +85C –13F to +185F
Operational method Zero-cross (Turn-ON and Turn-OFF)
AQ-R Discontinued as of August 31, 2011
4ds_61608_en_aqr: 010611D
DIMENSIONS(mm inch)
ACCESSORIES
Download from our Web site.
CAD Data
CAD Data
1. Plug-in terminal
CAD Data
Conform to AMP plug-in terminal
# 110 series receptacle
Mounting hole
Conform to AMP plug-in terminal
#250 series receptacle
9
.354
Max. 7.5
Max. .295 Max. 12.5
Max. .492
Max. 15
Max. .591
59
2.323
47.6
1.874
44.8
1.764
26
1.024
2-4.4 dia.
2-.173 dia.
Schematic
Mounting dimensions
(Bottom view)
Load power
source
Input power
source
+
_Load
2-4.3 dia. or M4
2-.169 dia.
47.60.1
1.874.004
2. Screw terminal
CAD Data
Mounting hole
4-M4
screw terminal
9
.354
Max. 7.5
Max. .295 max. 12.5
Max. .492
Max. 17
Max. .669
59
2.323
47.6
1.874
45.0
1.772
44.8
1.764
26
1.024
2-4.4 dia.
2-.173 dia.
Schematic
Mounting dimensions
(Bottom view)
Load power
source
Input power
source
+
_Load
2-4.3 dia. or M4
2-.169 dia.
47.60.1
1.874.004
Heat sink (For 10 A, 15A and 20 A)
AQP-HS-20A
CAD Data
80
3.150
1.5
.059
54
2.126
2
.079
2
.079
11.1
.437
33.3
1.311
50
1.969
47.6
1.874
90
3.543
100
3.937
1.5
.059
24.5
.965
28.5
1.122
9
.35445
1.772
R2.2
.087
2-M4
4.4
.173
4.4
.173
100
3.937
+9.5
-1.5
+.929
-.059
Mounting dimensions
(Bottom view)
General tolerance: 0.5
4-M4 or 4.4 dia
500.2
1.969.008
900.1
3.543.004
.020
AQ-R
Discontinued as of August 31, 2011
5
ds_61608_en_aqr: 010611D
Heat sink (For 30 A, 40 A)
AQP-HS-30/40A
CAD Data
90
3.543
4.4
.173 4.4
.173
50
1.969
54
2.126 100
+0.5
1.5
3.937
+.020
.059
80
3.150
33.3
1.311
47.6
1.874
56
2.205
150
5.906 24.5
.965
1.5
.059
2
.079
2
.079
11.1
.437
1.5
.059
28.5
1.122
45
1.772
9
.354
R 2.2 .087
3-M4
Mounting dimensions
(Bottom view)
General tolerance: 0.5
4-M4 or 4.4 dia
500.2
1.969.008
900.1
3.543.004
.020
mm inch
With terminal cover
AQP-PC
CAD Data
59
2.323 11.5
.453
47
1.850
24.5
.965
1.5
.059
5.5
.217
1.5
.059
General tolerance: 0.5 .020
DIN rail mounting plate
AQP-DP
CAD Data
86
3.386
44
1.732
18.1
.713
M4
70
2.765
56
2.205
47.6
1.874
13.6
.535
M4
M4
Mounting rail
CAD Data
AT8-DLA1
General tolerance: 0.5 .020
15
.591
5
.197 5
.197
10
.394
1,000
39.37
5.5
.217 35
1.378 1.5
.059
27
1.063
24
.945
15
.591
40-5.5×15 slot
40-.217×.591 slot
15
.591 10
.394 15
.591
7.5
.295
2.75R
.108R
AQ-R Discontinued as of August 31, 2011
6ds_61608_en_aqr: 010611D
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition:
Fastening plate
ATA4806
CAD Data
12
.472
50
1.969
M4
10
.394
10
.394
ATA4806
UP
mm inch
With external heat sink
1) (1) 10 A, 15A, 20 A type
• A heat sink; optional heat sink (AQP801) or
a 1501503.2 mm aluminum sheet
(painted black)
(2) 30 A, 40 A type
Shown with standard heat sink (AQP804)
2) If attached to a heat sink, use a heat-
conductive compound or similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
The graphs show the characteristics when the
relay is mounted as shown in the right figure. (1) 10 A type
Washers are added
to lift the relay.
Hole for radiation
(40×35 mm)
3 mm or
greater
0
-30 0 20 40 60 80
10
8
6
4
2
Ambient temperature, °C
Load current, A
Without external heat sink
With external
heat sink
(2) 15 A type (3) 20 A type (4) 30 A type
-30 0 20 40 60 80
20
16
12
8
4
0
Ambient temperature, °C
Load current, A
2
7
6
15
With external
Without external heat sink
-30 0 20 40 60 80
20
16
12
8
4
2
0
Ambient temperature, °C
Load current, A
With external
heat sink
Without external heat sink
30
40
50
20
10
00-30 20 40 60 80
Without external heat sink
Ambient temperature, °C
Load current, A
With external
heat sink
(5) 40 A type 2-1. Non-repetitive surge current vs. carrying
time (10 A type) 2-2. Non-repetitive surge current vs. carrying
time (15 A type)
30
40
50
20
10
00-30 20 40 60 80
Ambient temperature, °C
Load current, A
Without external heat sink
With external
heat sink
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
AQ-R
Discontinued as of August 31, 2011
7
ds_61608_en_aqr: 010611D
Cautions for Use
2-3. Non-repetitive surge current vs. carrying
time (20 A type) 2-4. Non-repetitive surge current vs. carrying
time (30 A, 40 A type) 3. Input current vs. input voltage
(10 A, 15 A, 20 A, 30 A, 40 A common)
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
0
100
200
300
400
500
1 2 3 4 5 7 10 20 304050 70 100
40A type
30A type
No. of cycles at 60 Hz
Non-repetitive surge current, A
30
25
20
15
10
5
0
Input voltage, V
Input current, mA
015
510 202530
(4 to 6 V) (10 to 18 V)
(18 to 28 V)