Du line Master Channel Generator Type G 3890 0014 (R) Fieldbus * * * * * * * * * * * * * * * * Product Description Programmable channel generator with built-in intelligent functions for light control, alarm monitoring, AnaLink set-point control, rollerblind control etc. Programming is easily performed through windows-based configuration software. A specific function Type Selection G 3890 0014 230 Type: Dupline(R) H8-housing Master channel generator Supply Input/Output Specifications Supply Ordering no. 115/230 VAC 10 to 30 VDC G 3890 0014 230 G 3890 0014 800 Supply Specifications Power supply AC-Types Rated operational voltage through term. 21 & 24 jumper term. 22 & 23 jumper term. 21 & 23 and term. 24 & 22 Frequency Rated operational power Rated impulse withstand voltage 115/230 V Dielectric voltage Supply - Dupline(R) Supply - Output Supply - Input Supply - Com. ports Power supply DC-Types Rated operational voltage through term. 21 & 22 Reverse polarity protection Rated operational power Inrush current Rated impulse withstand volt. Dielectric voltage Supply - Dupline(R) Supply - Output Programmable channel generator Configuration based on Windows 95/98/NT software Light control functions Alarm monitoring AnaLink set-point control Rollerblind control Real-time, timer and logic functions Print-out of events with date and time tags Alarms and events can be sent as SMS to GSM-phones (Only version <3.00) Controlling of functions via SMS from GSM-phones (Only version <3.00) H8-housing For DIN-rail mounting (EN 50022) AC or DC power supply Modbus-RTU interface RS 232 (only version > 2.02) Option for connecting two Dupline(R) Master Channel Generator Networks (only version > 2.02) Multiplex or normal mode Ordering Key with associated parameters can be assigned to each address and logic operations can be used to link the functions together. Surveillance and control of functions can be made via SMS from GSMphones by means of the GSM8 modem. Installationbus Serial Port Pin assignment TxD RxD GND Dielectric voltage Com.port - Dupline(R) Parallel Port Overvoltage cat. III (IEC 60664) Pin assigment 230 VAC 15% (IEC 60038) 115 VAC 15% (IEC 60038) 45 to 65 Hz Typ. 7 VA/3 W 4 kV 4 kVAC (rms) 4 kVAC (rms) 4 kVAC (rms) 4 kVAC (rms) Overvoltage cat. III (IEC 60664) 10-30 VDC Yes 7W 1A 800 V 500 V 200 V Strobe Data D0-D7 Busy Paper out GND Dielectric voltage Com.port - Dupline(R) Dupline(R)-Output Output voltage Current Short-circuit protection Sequence time 32 channels 128 channels Watchdog-Output Function Output voltage VDD Output current Output voltage drop Off-state leakage current Short-circuit protection Built-in protective diodes Dielectric voltage Output - Dupline(R) Output - Input Inductive loads Specifications are subject to change without notice (26.03.01) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group RS 232 9-pole female SUB-D Pin 2 Pin 3 Pin 5 2 kVAC (rms) Centronic 25-pole female SUB-D Pin 1 Pins 2-9 Pin 11 Pin 12 Pins 18-25 2 kVAC (rms) Dupline(R) carrier 8.2 V < 100 mA Yes 38.6 ms 132.3 ms 1 NPN transistor Watchdog 35 VDC 100 mA 2V 100 A None None 4 kVAC (rms) 4 kVAC (rms) External noise suppression required 1 Du line G 3890 0014 (R) Fieldbus Input/Output Specifications (cont.) General Specifications Input Function Isolated in groups of Input voltage range Reverse polarity protection Rated operational current Input resistance Cable length Dielectric voltage Input - Dupline(R) (230 V Version) Input - Dupline(R) (800 V Version) Adjustment 4 tactile pushbuttons (Mode, Up, Down, Enter) Real-time clock Accuracy Internal back-up time Unit parameter back-up time Power ON delay Indication for Supply ON ON Line Busy Fault Time, date etc. Communication LPT Back-up supply Real-time clock 1x1 4.5 to 9 V Yes 10 to 100 A > 47 k < 0.5 m 4 kVAC (rms) 500 V Time, Date, Year, Day RS 232 functions LPT functions Centronic For serial printer / DOScommands RS232 Normal mode Spec. mode Download of configuration Modbus-RTU protocol (Short-cut pin 7 and pin 8) Pin 2 Pin 3 Pin 5 Pin 7 Pin 8 Txd Rxd Gnd RTS CTS Installationbus Better than 1 minute/month Typ. 120 hours > 1 year < 2.5 s LED, green LED, yellow LED, yellow LED, red 4-digit LCD display red background light Environment Degree of protection Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Material (see "Technical Information") Weight IP 20 3 (IEC 60664) 0 to +50C (+32 to +122F) -20 to +85C (-4 to +185F) 20 to 80% RH 15 G (11 ms) 2 G (6 to 55 Hz) H8-housing 540 g Wiring Diagrams G 3890 0014 230 Dupline(R) S 1 2 G 3890 0014 800 Dupline(R) S 0.1 A 3 4 35 V + 6 7 5 8 9 10 11 12 13 14 15 16 1 2 3 4 5 0.1 A 35 V + 6 7 8 9 10 11 12 13 14 Noise red. Noise red. Watchdog NPN RS 232 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 + 21 36 Power supply 230 VAC 16 22 Watchdog NPN RS 232 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Backup 4.5-9 V Backup 4.5-9 V Supply 15 Centronic Centronic Supply 10-30 VDC 7 W Power supply 115 VAC Key Operation Diagram Show date Display Time of day Show day of the week Show year Main Setting Mode Set-Up [SEt] 2 Set Time [HrS] Time Format [FOr] Set Date [dAtE] Date Format [FOr] Set Day [dAY] Set Year [YEAr] Specifications are subject to change without notice (26.03.01) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group Du line G 3890 0014 (R) Fieldbus Installationbus Mode of Operation The G 3890 0014 master generator is a programmable channel generator which is particularly well suited for building automation applications like lighting control, rollerblind control, temperature control, and alarmmonitoring. Through an easy-touse windows-based configuration software, the unit can be configured to perform real-time control, logic and timer functions, ISA, water, smoke and Intruder alarm-monitoring and Code/ Door lock armouring. Print-outs of time-tagged userdefined text in case of channel output changes. Keys In the display mode, the four front-keys are used to change the display showing time, date, day of the week, year or software revision of the master generator (Press < enter >). The keys are also used to set the time, date, day of the week, year and definition of operation and parameters of the parallel ports. Display The back-lighted 4-digit LCD display is used to show all the relevant information that can be changed by using the keys. If no key is pressed for 2 minutes, the display automatically shows the actual time. In case of an Error the display shows an Error code. Back-up Terminals In case of missing power the internal calendar and clock are supported by a super-capacitor. Under normal ambient temperature this back-up will maintain the correct date and time for typically 5 days. If longer power shutdowns can occur, an external battery of 4.5 to 9 VDC may be connected between terminal 35 (+) and terminal 36 (-). Alarm Output Terminals An open collector NPN-transistor output with NC function signals alarms and faults in the system. Attention by the local personnel is requested whenever this output switches off. The display and/or the LEDs gives an indication of the cause of problem. Pin Assignment Master Generator Configuration The master generator is as factory default configured to operate as a standard channel-generator without intelligent functions. To obtain full utilisation of the advanced features, the generator has to be configured. For configuration, the delivered software SW G 3890 0014 has to be installed on a Win 95/98/NT based PC. This software handles all configuration of the G 3890 0014 master generator. The software version must be consistent with the firmware version of the Master Generator. Press on top of the Master Generator to see the version in the display. Configuration is done entirely on the PC, and when completed, the set-up is downloaded into the generator via the serial port. (COM1 or COM2). Two Dupline(R) networks* Two channel generators can be connected via communication cable. Thereby addresses, i.e. master commands, can be transferred from one network to the other by means of the matrix mapping in the configuration software. Entering "1" in the desired Dupline(R) address performs selection of the channel status from the other Dupline(R) network. Modbus-RTU* Modbus-RTU is implemented as a function of a slave. The following Modbus functions are supported: 01, 02, 03, 05, 06 and 16. See: Modbus-RTU Memory Mapping. SMS** Surveillance and control of Dupline(R) channels can take place by means of the SMS option. The G38900014 module can call up several GSM phones, when an event or alarm appears, and a GSM phone can change the status of a Dupline(R) channel/function. The last option is "Dial-in number" and password protected. * Rev. 2.02 or higher required **Rev 3.xx or higher required RS 232 Cables 5 1 9 6 Pin Signal 2 3 5 7 8 TxD RxD Signal Ground RTS CTS 9-pin male to Controller #2 2 3 5 7 8 9-pin male to controller #1 2 3 5 7 8 Two Dupline(R) Networks Cable 9-pin male to controller 2 3 5 7 8 9-pin female to PC 2 3 5 7 8 Configuration Cable 13 1 25 14 9-pin male to controller 2 3 5 7 8 9-pin female to PC 2 3 5 Modbus RTU Cable Pin Signal 1 2-9 11 12 18-25 Strobe Do - D7 Busy Paper out GND 9-pin male to controller 2 3 5 7 8 GSM8 Term 4 Term 5 Term 1 GSM modem Cable Specifications are subject to change without notice (26.03.01) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 3 Du line (R) Fieldbus Installationbus Modbus-RTU Memory Mapping Function code 01 Read Output Table Address 500 501 57F Function Code 03 Read Multiple Registers Address 0000 0001 0007 0100 0101 017F 0200 #0 0202 #1 0204 #2 2FC #126 2FE #127 Function code 05 Set single Output Bit Address 1500 1501 157F Function code 02 Read Input Table Address 600 601 67F Dupline(R) Channel A1 A2 P8 Data Word MSB...HB B8...B1 D8...D1 P8...P1 Analink A1 Analink A2 Analink P8 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 0..99 Dupline(R) Channel A1 A2 P8 Data Word MSB...HB B8...B1 D8...D1 P8...P1 LB...LSB A8...A1 C8...C1 O8...O1 Function Code 16 Preset Multiple Registers Address 1000 1001 1007 Data Word MSB...HB B8...B1 D8...D1 P8...P1 LB...LSB A8...A1 C8...C1 O8...O1 Scope of Supply 4 A1 A2 P8 LB...LSB A8...A1 C8...C1 O8...O1 Function Code 06 Preset single Register Address 1000 1001 1007 1 x Master Channel Generator 1 x User manual 1 x RS 232 cable 1 x Configuration software Dupline(R) Channel Accessories G 3890 0014 .. MAN G 3890 0014 ENG RS 232-9 M/9 F SW G 389XX14 version 3.00 User manual GSM modem MAN G3890 0014 ENG GSM8 For further information refer to "Accessories". Specifications are subject to change without notice (26.03.01) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group