Scheduled to be Discontinued at the end of April 2015 PCB Relay G5LA A Cubic, Single-pole 10A Power Relay * Economical cube relay with universal terminal footprint * Conforms to VDE0435, CQC * UL recognized/ CSA certified. * High switching power: 10A @ 250VAC * Withstands impulse of up to 4,500V * Coil power consumption: 360mW * UL Class F coil insulation type also available * Tracking resistance: CTI>250 * RoHS Compliant Ordering Information Type Contact form SPST-NO (Class A) Standard SPST-NO (Class F) SPDT (Class A) SPDT (Class F) High-capacity SPDT (Class A) SPDT (Class F) Enclosure ratings Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Model G5LA-1A G5LA-1A4 G5LA-1A-CF G5LA-1A4-CF G5LA-1 G5LA-14 G5LA-1-CF G5LA-14-CF G5LA-1-E G5LA-14-E G5LA-1-E-CF G5LA-14-E-CF Note: When ordering, add the rated coil voltage to the model number. Example: G5LA-1 DC12 Rated coil voltage Model Number Legend G5LA- @ @ @ - @ - @ DC @ 1 2 3 4 1. Number of Poles 1: 1 pole 2. Contact Form None: SPDT A: SPST-NO 3. Enclosure Ratings None: flux protection 4: fully sealed 5 6 4. Type None: Standard E: High Capacity (SPDT only) 5. Insulation Class None: Class A CF: Class F 6. Rated Coil Voltage 5, 9, 12, 24, or 48 PCB Relay G5LA 185 Scheduled to be Discontinued at the end of April 2015 Specifications Coil Ratings Rated Voltage (VDC) 5 9 12 24 48 Rated current (mA) 72 40 30 15 10 Coil resistance () 69.4 225 400 1600 4800 Must operate voltage 75% max. Must release voltage 10% min. Rated power consumption (W) Approx. 0.36 Max voltage 130% of rated voltage at 85C 170% of rated voltage at 23C Approx. 0.48 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%. 2. Please avoid ultrasonic cleaning this relay. Contact Ratings Rated load (resistive) SPST-NO SPDT High-capacity Rated carry current Max. switching voltage Max. switching current Max. switching capacity Min. permissible load 10 A @ 250 VAC (NO) 10 A @ 24 VDC (NO) 5 A @ 125 VAC (NO/NC) 5 A @ 24 VDC (NO/NC) 5 A @ 250 VAC (NO/NC) 5 A @ 24 VDC (NO/NC) 10 A (SPST-NO) 10 A (High-capacity) 5 A (SPDT) 250 VAC 24 VDC 10 A SPST-NO 5A SPDT, High-capacity 2500 VA, 240 W (NO) 625 VA, 120 W (NC) 1250 VA, 120 W (NO/NC High-capacity) 100 mA at DC5V (P level: 60 = 0.1 x 10-6 / ops) Contact Material AgSnO2 Note: SPDT type can switch up to 10 A @ 250 VAC/24 VDC Resistive Load on NO contact if there is no load on the NC contact. Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength Vibration resistance Shock resistance Life expectancy Ambient temperature Ambient humidity Weight 100 m max. 10 ms max. 5 ms max. Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) 1,000 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 minute between coil and contacts 750 VAC, 50/60 Hz for 1 minute between contacts of same polarity Destruction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Destruction: 1,000 m/s2 (approx. 100G) Malfunction: Mechanical: Electrical: Operating:Storage: Operating: Storage: Approx. 7.5g 100 m/s2 (approx. 10G) 10,000,000 operations min. (at 18,000 operations/hr under no load) 100,000 operations average. (at 1,800 operations/hr under rated load) 40C to 85C (with no icing or condensation) -40C to 85C (with no icing or condensation) 35% to 85% 35% to 85% Note: 1. Data shown are of initial value. 2. All G5LA Class A rated relays are factory guaranteed to maximum Operating Temperature of 85C. UL rated maximum temperature is pending approval for Class B rating. 186 PCB Relay G5LA Scheduled to be Discontinued at the end of April 2015 Approved Standards UL Recognized (File No. E41643) & CSA Certified (File No. LR31928) - - Ambient Temp. = 40C Model G5LA Coil rating 5 to 48 VDC Contact rating NO: 10 A, 277 VAC, general use,100,000 cycles 10 A, 30 VDC, resistive, 50,000 cycles 1/2 HP, 125-250VAC, 1,000 cycles 10 A, 277 VAC, general use, 85C 50,000 cycles (-CF type only) 200 W Tungsten, 125 VAC, 100,000 cycles NC: 10 A, 125 VAC, resistive 10 A, 277 VAC, general use, 100,000 cycles (-E type only) 10A, 24 VDC, resistive, 100,000 cycles (-E type only) VDE0435 (EN61810-1) Model Coil rating 5,9,12,24,48 VDC Contact rating NO: 10 A, 250 VAC, resistive, 85C - flux protection: 50,000 cycles - fully sealed: 10,000 cycles 12 A, 125 VAC, resistive, 85C, 10,000 cycles CO: 5 A, 250 VAC, resistive, 85C - flux protection: 50,000 cycles - fully sealed: 10,000 cycles Model Coil rating 5,9,12,24,48 VDC Contact rating NO: 10 A, 250 VAC, resistive, 10,000 cycles 12 A, 120 VAC, resistive, 10,000 cycles G5LA CQC G5LA PCB Relay G5LA 187 Scheduled to be Discontinued at the end of April 2015 Dimensions Note: All units are in millimeters unless otherwise indicated. SPDT Models 15.8max (15.6)* 19.8max (19.6)* Terminal Arrangement/Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: 0.1 mm Unless specified SPDT SPDT 2- 1 15.8max (15.6)* 3- 1.3 0.2 12 0 (1.4) 0.28 2 1 0.5 0.4 2 12.2 (1.8) 3.3 0.4 .1 00.2 0.4 1.2 12 12.2 *Average value SPST-NO Models 15.8max (15.6)* 19.8max (19.6)* Terminal Arrangement/Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: 0.1 mm Unless specified SPST-NO SPST-NO 2- 1 0 12 15.8max (15.6)* 3- 1.3 0.2 (1.4) 0.28 2 0.5 1 1.2 0.4 12.2 12 *Average value 188 PCB Relay G5LA 2 12.2 (1.8) 3.3 0.4 .1 00.2 Scheduled to be Discontinued at the end of April 2015 Engineering Data Switching current (A) 10 7 Electrical service life NO (Average value) Service life (x103 operations) Maximum switching capacity (NO) AC resistive load 5 3 DC resistive load 1 0.7 0.5 0.3 5,000 3,000 1,000 700 500 30-VDC resistive load 120-VAC resistive load 300 100 70 50 30 0 10 30 50 125 250 500 1,000 0 0 Switching voltage (V) 2 4 6 8 10 Switching current (A) Note: The 120 VAC resistive load service life curve also applies for 250 VAC resistive load. Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) 200 180 160 140 120 100 0 -25 2023 30 40 50 60 70 80 90 100 Ambient temperature ( C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage not a continuous voltage. PCB Relay G5LA 189 Scheduled to be Discontinued at the end of April 2015 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. X301-E-1c PCB Relay 12/14 (09/11) G5LA Specifications subject to change without notice Printed in USA