Industrial Power Supplies TIS Series 50 - 600 Watt Features (LVD) Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies with EN50081-2 and EN50082-2 Conducted EMI to EN55011 class B For system operation available with built-in functions: RED: Redundancy module for N+1 systems with true current sharing The switching power supplies of the TIS series have been particularly deSIG: Signal module with AC-Powersigned for applications in industrial process control systems and machine fail, Power Good Signal and tools. Excellent specifications and high immunity against electrical disturbances external ON/OFF control guarantee reliable power for sensitive loads in rugged industrial environUDS: DC-UPS module for uninterments. With help of optional function modules specific requirements for sysruptable battery backed-up tem applications can be easily realized with a standard model. With the UDS power systems module the power supplies can be extended to a perfect DC-UPS with autoWorldwide Safety Approvals matic battery- backup. This function is very often required in applications Easy snap-on mounting on DIN-rails where a time delayed shutdown of a system is necessary. To monitor and control the power supply a signal module can be installed. For parallel opor chassis mounting eration with active power sharing a redundancy option is available. This flexibility makes the TIS series power supplies a cost effective solution for many industrial applications. Models Ordercode (includes terminal plugs) Input Voltage nom. Output Power max. Output Voltage nom. Output Current max. TIS 50-112 TIS 50-124 115 - 240 VAC universal input 50 W 12 VDC 24 VDC 3.5 A 2.0 A TIS 75-112 TIS 75-124 TIS 75-148 115 / 230 VAC selectable 75 W 12 VDC 24 VDC 48 VDC 6.0 A 3.0 A 1.5 A *TIS 150-124 (P) *TIS 150-148 (P) 115 / 230 VAC selectable 150 W 24 VDC 48 VDC 6.0 A 3.0 A *TIS 300-124 (P) *TIS 300-148 (P) TIS 300-172 115 / 230 VAC selectable 300 W 24 VDC 48 VDC 72 VDC 12 A 6.0 A 4.2 A TIS 500-124-115 TIS 500-124-230 115 VAC 230 VAC 500 W 500 W 24 VDC 24 VDC 20 A 20 A TIS 600-124 TIS 600-128 TIS 600-148 TIS 600-172 115 / 230 VAC selectable 600 W 24 VDC 28 VDC 48 VDC 72 VDC 24 A 22 A 12 A 8.5 A *If compliance to EN 61000-3-2 (PFHC - Power Factor Harmonic Current) is required, option P is available for these models http://www.tracopower.com Page 1 Industrial Power Supplies TIS Series 50-600 Watt Input Specifications Input voltage range - - - - TIS 50 TIS 75,150, 300, 600 TIS 500-124-230 TIS 500-124-115 Input frequency 47 - 63 Hz Input current at full load (typ.) Recommended circuit breaker, characteristic C or fuse, slow blow typ 93 - 264 VAC 93 - 132 VAC / 187 - 264 VAC 187 - 264 VAC 93 - 132 VAC - - - - - - TIS TIS TIS TIS TIS TIS 50 75 150 300 500 600 115 VAC 1.2 A 1.7 A 3.0 A 5.4 A 9.5 A 10.5 A - - - - - - TIS 50 TIS 75 TIS 150 TIS 300 TIS 500 TIS 600 5.0 A 5.0 A 10.0 A 15.0 A 15.0 A 20.0 A - - - - - 12 24 28 48 72 230 VAC 0.7 A 0.9 A 1.7 A 3.3 A 5.5 A 6.4 A Output Specifications Output voltage adj. range VDC VDC VDC VDC VDC models models models models models Regulation - Input variation - Load variation (10 - 90 %) 12 24 28 48 60 - - - - - 14 28 32 52 76 VDC VDC VDC VDC (48 - 55 VDC on request)) VDC 0.2 % max. - TIS 50, TIS 75, TIS 150 1.0 % max. - TIS 300, TIS 500, TIS 600 0.3 % max. (2.0 % in parallel operation) Ripple and Noise (20MHz Bandwidth) < 50 mV pk-pk Electronic short circuit protection current limitation at 110 % typ. (constant current, automatic restart) Overvoltage protection, triggerpoint at 140 % typ. Vout nom. Hold-up time - TIS 50 ... TIS 300 - TIS 500 - TIS 600 115 VAC min. 25 ms min. 20 ms min. 15 ms 230 VAC min. 30 ms min. 40 ms min. 25 ms All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 Industrial Power Supplies TIS Series 50-600 Watt General Specifications Temperature ranges - Operating (ambient temp.) - Derating above 50 C (122F) - 25 C...+70 C max.(- 13F...+185F) 2% /K - 25 C...+ 85 C - Storage (non operating) (- 13F...+185F) Humidity (non condensing) 95 % rel H max. Pollution degree 2 Temperature coefficient 0.02 % / C Switching frequency 80 kHz typ. (Pulswidth modulation) Efficiency 85 % typ. 90 % typ. 90 % typ. - TIS 50 ... TIS 300 - TIS 500 - TIS 600 Isolation according to IEC/ EN 60950, UL 60950, UL 508 Reliability, calculated MTBF (MIL-HDBK-217 E) - TIS 50 /75 - TIS 150 /300 - TIS 500 /600 450000 h @ +25C/ 420000 h @ +25C 420000 h @ +25C/ 360000 h @ +25C 340000 h @ +25C/ 300000 h @ +25C Safety standards IEC/ EN 60950 (SELV, except 72 VDC models), UL/cUL 60950, UL 508, UL/cUL 1604 Safety approvals (TIS 500 pending) UL/cUL 60950 recognized, File E181381 UL/cUL 508 listed, File E210002 (tested by UL to surrounding temperature of 40C) * UL/cUL 1604 listed, File E213613 (Class I, Division 2, Groups A, B, C and D hazardous locations) CB-Report as per IEC 60950 *basic models except TIS50 & TIS500 Electromagnetic compatibility (EMC), Emissions - Conducted RI suppression on input - Harmonic current emissions (for -P models) EN 50081-1 / EN 50081-2 EN 55011 class B, EN 55022 class B, FCC part 15, level B EN 55011 class A, EN 55022 class A, FCC part 15, level A EN 6100-3-2, class A Electromagnetic compatibility (EMC), Immunity - Electrostatic discharge (ESD) - Radiated RF field immunity - Electrical fast transient / burst immunity - Surge immunity - Immunity to conducted RF disturbances - Power frequency field immunity EN 50082-2 IEC / EN 61000-4-2 IEC / EN 61000-4-3 IEC / EN 61000-4-4 IEC / EN 61000-4-5 IEC / EN 61000-4-6 IEC / EN 61000-4-8 Safety class Degree of electrical protection 1 (IEC 536) Case protection IP 20 (IEC 529) - Radiated RI suppression Environment - Vibration - Shock 4 kV / 8 kV 10 V / m 2 kV 2 kV / 4 kV 10 V 30 A / m IEC 60068-2-6;1 gn, 200 sweeps, each axis IEC 60068-2-27; 15 gn, 11 ms, each axis Enclosure material Aluminium (chassis) / zinc plated steel (cover) Mounting (snap-on with selflocking spring) for 35 mm DIN-rails as per EN 50022 Connection Plugable screw terminals (plugs included) (TIS 600: screw terminal blocks) All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 Industrial Power Supplies TIS Series 50-600 Watt OutlineSupplies Power Dimensions withmm Redundancy (inches) Function With this option a parallel operation of up to 5 units is possible. Decoupling diodes and current share lines allow to build true N +1 redundant systems with active current sharing for all units. This function also includes an alarm relay to signal a single unit failure. This option is available for TIS 150 W, TIS 300 W and TIS 600 W models. Please note: A combination with other options is not possible. Models Output Power max. Output Voltage nom. Output Current max. TIS 150-124 RED TIS 150-148 RED 115 / 230 VAC selectable 150 W 24 VDC 48 VDC 6.0 A 3.0 A TIS 300-124 RED TIS 300-148 RED 115 / 230 VAC selectable 300 W 24 VDC 48 VDC 12 A 6.0 A TIS 600-124 RED TIS 600-148 RED 115 / 230 VAC selectable 600 W 24 VDC 48 VDC 24 A 12 A L N Con1 Pin3 Con1 Pin2 Con2 - Pin3/4 AC Bus Indicator DC Con2 - Pin1/2 +Vout 24/48VDC Input Voltage 115/230VAC Ordercode (includes terminal plugs) -Vout Con1 Pin1 I-Sense V-Sense Con3 - Pin4 Con3 - Pin3 Con3 - Pin2 Con3 - Pin1 Regulator Current Shareline Unit OK Common Unit OK Unit OK Specifications Raiting per relay contact 60 VDC /0.36 A max. Download detailed instruction manual for RED option: http://tracopower.com/products/tis_red_manual.pdf Specifications can be changed without notice http://www.tracopower.com Page 4 Industrial Power Supplies TIS Series 50-600 Watt Power Supplies with Powerfail Functions These models provide 3 functions required in many process control system applications: * AC-Powerfail signal (relay contact) * Power Good signal (relay contact) * Remote ON/OFF Models Output Power max. Output Voltage nom. Output Current max. 115 / 230 VAC selectable 150 W 24 VDC 48 VDC 6.0 A 3.0 A TIS 300-124 SIG TIS 300-148 SIG 115 / 230 VAC selectable 300 W 24 VDC 48 VDC 12 A 6.0 A TIS 600-124 SIG TIS 600-148 SIG 115 / 230 VAC selectable 600 W 24 VDC 48 VDC 24 A 12 A L N Con1 Pin3 Con2 - Pin3/4 AC Con1 Pin2 +Vout 24/48VDC TIS 150-124 SIG TIS 150-148 SIG Output OK DC Con2 - Pin1/2 Con1 Pin1 Con3 - Pin2 + Con3 - Pin1 Remote ON/OFF - Con3 - Pin7 Con3 - Pin6 Mains Fail Detection -Vout Remote ON/OFF Input Voltage 115/230VAC Ordercode (includes terminal plugs) Common AC-Powerfail Mains OK (Relay A) Con3 - Pin5 Con3 - Pin4 Con3 - Pin3 DC-OK Detection (Relay B) DC-OK Common DC-OK DC-OK Specifications Power Good signal trigger point - Models with 24 Vout - Models with 48 Vout > 22.8 VDC 0.5 V > 45.6 VDC 1.0 V relay B closed (pin 4 - pin 3) relay B closed (pin 4 - pin 3) AC-Powerfail signal Vin < 93 resp. < 187 VAC relay A closed (pin 7 - pin 6) Raiting per relay contact 60 VDC /0.36 A max. Remote ON / OFF ON: short circuit con 3 pin 1 and pin 2 OFF: open circuit con 3 pin 1 and pin 2 Download detailed instruction manual for SIG option: http://tracopower.com/products/tis_sig_manual.pdf All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 5 Industrial Power Supplies TIS Series 50 -600 Watt DC-UPS-System In addition to the standard power supply function, these models include a professional battery management system to charge and monitor an external battery. In case of a power failure the battery is switched automatically and without any interruption to the DC-output. If mains power is available again, the battery is switched off. The hold-up time is limited only by battery capacity and load. Charge current and voltage can be adjusted to values as required by battery type. Power fail and low battery alarm signals are available via two independent relay contacts. During normal operation the battery status is monitored by periodically loading the battery for short time. If a cell resistance is high, there is a relay alarm available. The battery is fully protected under any operational conditions. The power supply is short circuit protected even in batterybackup operation, however for safety reason the battery should be fused with a fast blow fuse. Battery mode can be activated by connection of Pin 7 and 8. Complete external battery packs (3.2 Ah or 7 Ah standard) with lead batteries and circuit breaker are available (see page 8). Models Ordercode (includes terminal plugs) Input Voltage Output Power max. Output Voltage nom. *Output Current max. TIS 300-124 UDS 115 / 230 VAC selectable 300 W 24 VDC 12 A TIS 600-124 UDS 115 / 230 VAC selectable 600 W 24 VDC 24 A *reduce max. output current by battery charging current All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 6 Industrial Power Supplies TIS Series 50-600 Watt DC-UPS-System Battery + Con3 - Pin2 V Battery Charger L N I Con1 Pin3 AC Con1 Pin2 Con2 - Pin3/4 Output OK DC Con2 - Pin1/2 Con1 Pin1 +Vout 24VDC 115/230VAC Battery - Con3 - Pin1 -Vout VBat>18V Bat ON/OFF Mains Fail Battery Switch Logic Con4 Pin8 Battery ON/OFF Con4 - Pin3 Con4 - Pin2 Con4 - Pin1 Mains Fail Detection Con4 Pin7 AC-Powerfail Common AC-Power OK AC-Powerfail (Relay A) Con4 - Pin6 Con4 - Pin5 Con4 - Pin4 Battery Test Battery Low / failure Common Battery OK Low Battery (Relay B) Specifications Charging current (factory set) - TIS 300-124 UDS - TIS 600-124 UDS 1.2 A 2.4 A Adjustment range of charging current - TIS 300-124 UDS - TIS 600-124 UDS 0.15...1.5 A 0.25...2.5 A Holding current for charging battery at voltage 27.3 VDC < 50 mA Overload at short circuit during battery operation system switches off AC-Powerfail signal Vin < 93 resp. < 187 VAC relay A closed (pin 2 - pin 3) Low battery signal Battery voltage below 22 V relay B closed (pin 5 - pin 6) Raiting per relay contact During battery charge operation 60 VDC /0.36 A max. output current reduction by 1.4 x battery charge current Download detailed instruction manual for UDS option: http://tracopower.com/products/tis_uds_manual.pdf All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 7 Industrial Power Supplies TIS Series 50-600 Watt Battery-Pack for DC-UPS Systems The Battery Pack contains high quality, maintenance free lead-acid batteries with 3.2 Ah resp. 7.0 Ah capacity. The batteries are fixed together with a re-settable electronic fuse on a solid mounting frame. Together with power supply models TIS 300-124 UDS or TIS 600-124 UDS the battery pack provides a complete and reliable DC-UPS system. Backup time is depending on load current and battery capacity. Models Ordercode Battery Voltage Battery Capacity (25C, 20h-rate) Permissable Charge Current max. TIS 24-32 AP TIS 24-70 AP 24 VDC 24 VDC 3.2 Ah 7.0 Ah 1.2 A 2.4 A Specifications Max. charge voltage 27...27.6 VDC Temperature coefficient - 36mV /C Temperature range - at charge operation - at load operation - Storage - 15 C...+50 C - 20 C...+60 C - 20 C...+60 C Average lifetime on standby operation at tA =20 C 4...5 years Cable length 1.0 m Cable diameter - TIS 24-32 AP - TIS 24-70 AP 2.5 mm2 (AWG 12) 4.0 mm2 (AWG 11) Weight - TIS 24-32 AP - TIS 24-70 AP 4.6 kg (10.1 lb) 5.9 kg (13.0 lb) Recommended combinations - TIS 24-32 AP (power supplies) - TIS 24-70 AP TIS 300-124 UDS TIS 600-124 UDS All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 8 Industrial Power Supplies TIS Series 50-600 Watt Outline Dimensions mm (inches) Model TIS 50-112 Input L N 115/230 VAC 1,2/0,7 A Output +- 12 VDC 3,5 A 75 (2.95) 5 56.7 (0.2) (2.23) 115/230 VAC 1,7/0,9 A Industrial Power Supply DC-ON Model TIS 75-112 (1.56) +- 39.5 Output adj 34 (1.34) L N 12 VDC 6A 86.5 (3.4) Industrial Power Supply Input 114.6 (4.51) DC-ON (1.24) 74.0 (2.91) 26 100.0 (3.94) adj 31.5 TIS 75 (1.02) TIS 50 5 90 (3.54) 56.7 (2.23) (0.2) 45 (1.77) 37.5 10 (0.39) 10 (0.39) (1.48) Weight: TIS 50 0.41 kg (0.9 lb) TIS 75 0.48 kg (1.06 lb) +- (1.56) 24 VDC / 6 A DC-ON Industrial Power Supply Model TIS 150-124 Input 115/230 50/60Hz 3,7/1,7 A N L 86.5 (3.4) 114.6 (4.51) Output 39.5 34 (1.34) TIS 150 5 157 (6.18) 56.7 (2.23) (0.2) 38.5 80 (3.15) Weight: (1.52) 10 Specifications can be changed without notice http://www.tracopower.com (0.39) TIS 150 0.80 kg (1.76 lb) Tolerances: 0.5 mm (0.02) Page 9 Industrial Power Supplies TIS Series 50-600 Watt Outline Dimensions mm (inches) (1.56) DC-ON 91.5 (3.6) Industrial Power Supply Model Input TIS300-172 (1.36) 114.6 (4.51) ++- - 72 VDC / 4 A 39.5 Output 34.5 34 (1.34) TIS 300 115/230 50/60Hz 5,4/3,3 A N L 207 (8.15) 5 (0.2) 130 (5.12) 38.5 83 (3.27) 10 83 (3.27) (0.39) (1.52) Weight: TIS 300 1.4 kg (3.09 lb) Industrial Power Supply 47 (1.85) DC-ON Model TIS 500-124-230 Input 230 VAC 50/60Hz 5,3 A N L 94 (3.7) 130 (5.12) 41.5 (1.63) TIS 500 Output 24 VDC / 20 A ++- - 220 (8.66) 5 83 (3.27) (0.2) (0.39) 130 (5.12) 10 46 (1.81) Weight: TIS 500 Specifications can be changed without notice http://www.tracopower.com 1.9 kg (4.19 lb) Tolerances: 0.5 mm (0.02) Page 10 Industrial Power Supplies TIS Series 75-600 Watt Outline Dimensions mm (inches) TIS 600 Input Industrial Power Supply Output - -++ 24 VDC / 20 A 120.2 (4.73) 177.2 (6.98) N L 115/230 VAC 50/60Hz 10,5/6,4 A Model TIS 600-124 243 (9.57) 32 82.6 (3.25) 179 (7.05) (0.27) 6.8 82.8 (3.26) (1.26) Weight: TIS 600 Specifications can be changed without notice http://www.tracopower.com 2.0 kg (4.41 lb) Tolerances: 0.5 mm (0.02) Page 11 Industrial Power Supplies TIS Series 50-600 Watt Outline Dimensions mm (inches) Optional Mounting Systems Dimensions mm (inches) Wall mounting A B 7.5 4.6 Models Order code (0.30) E D C (0.18) A B C D E TIS 75W MK-75 37 (1.46) 14.5 (0.57) - 134.5 (5.30) 150.5 (5.93) TIS 150W MK-150 132 (5.20) 13.5 (0.53) 105 (4.13) 134.5 (5.30) 150.5 (5.93) TIS 300W MK-300 132 (5.20) 13.5 (0.53) 105 (4.13) 134.5 (5.30) 150.5 (5.93) TIS 500W MK-500 132 (5.20) 13.5 (0.53) 105 (4.13) 134.5 (5.30) 150.5 (5.93) TIS 600W MK-600 190 (7.48) 37.5 (1.48) 115 (4.53) 197.0 (7.76) 207.0 (8.15) Rugged DIN-Rail mounting A B Models countersink M4 25 (0.98) 50.1 (1.97) 4.2 (0.17) C Order code A B C TIS 150W RMK-150 150 (5.91) 115 (4.53) 35 (1.38) TIS 300W RMK-300 200 (7.87) 165 (6.50) 35 (1.38) TIS 500W RMK-300 200 (7.87) 165 (6.50) 35 (1.38) TIS 600W standard 180 (7.09) 165 (6.50) 15.0 (0.59) Specifications can be changed without notice http://www.tracopower.com Tolerances: 0.5 mm (0.02) Page 12 Industrial Power Supplies TIS Series 50-600 Watt Outline Dimensions mm (inches) 204 (8.03) TIS-24-32 AP 14 184 (7.24) (0.55) Detail A 7 7 12 Detail B 9 (0.28) 69 (2.72) (0.47) 5.8 B (0.35) B 135 (5.14) A 100 (3.94) A (0.23) (0.28) Weight (incl. batteries): TIS-24-32 AP 4.6 kg (10.1 lb) TIS-24-70 AP 5.9 kg (13.0 lb) 272 (10.71) TIS-24-70 AP A B B 69 (2.72) 100 (3.94) A 152 (5.98) 252 (9.92) Specifications can be changed without notice Tolerances: 0.5 mm (0.02) Rev. 12/02 Jenatschstrasse 1 * CH-8002 Zurich * Switzerland Tel. +41-1284 2911 * Fax +41-1201 1168 * e-mail: sales@traco.ch * internet: http://www.tracopower.com Page 13