Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sock- ets. Wide choice of supply voltages: 24, 100 to 120, 200 to 240 VAC, 24 VDC. Dual LED indication for power and output sta- tuses. Large transparent setting knob. Setting error rating almost matches that of a 48 x RC 48 timer. Conforms to UL and CSA, and meets CE marking requirements. Ordering Information Operation/resetting system Time-limit operation/ self-resetting Time-limit contact SPDT Mounting method Surface mounting, flush mounting, and DIN track mounting DPDT Note: Rated time Model 1 s, 3 s, 5 s, 10 s, 30 s, H3JA-8A 60 s, 3 min, 5 min, 10 min, 30 min, 60 min, 3 hrs 1 s, 3 s, 5 s, 10 s, 30 s, 60 H3JA-8C s, 3 min, 5 min, 10 min, 30 min, 60 min, 3 hrs Specify the model number, supply voltage, and rated time when ordering. Ex. H3JA-8A 100 to 120 VAC 1 s Rated time Supply voltage Accessories (Order Separately) Name/specifications Flush Mounting Adapter Mounting Track Models Y92F-31 50 cm (&) x 7.3 mm (t) PFP-50N 1 m (&) x 7.3 mm (t) PFP-100N 1 m (&) x 16 mm (t) End Plate PFP-100N2 PFP-M Spacer PFP-S Track Mounting/ Front Connecting Socket 8-pin PF085A Back Connecting Socket 8-pin US08 8-pin P3G-08 8-pin, finger safe type P3G-08 with Y92A-48G (see note 1) For PF085A Socket Y92H-6 Hold-down Clip (see note 2) Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. 2. Hold-down Clips are sold in sets of two. 1 H3JA H3JA Specifications Time Ranges Rated time 1s Time range 0.1 to 1 s Rated time Time range 3 min 0.3 to 3 min 0.5 to 5 min 3s 0.3 to 3 s 5 min 5s 0.5 to 5 s 10 min 1 to 10 min 10 s 1 to 10 s 30 min 3 to 30 min 30 s 3 to 30 s 60 min 6 to 60 min 60 s 6 to 60 s 3 hrs 0.3 to 3 hrs Ratings Rated supply voltage 24, 100 to 120 or 200 to 240 VAC (50/60 Hz); 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption H3JA-8A 100 to 120 VAC: 200 to 240 VAC: 24 VAC: 24 VDC: H3JA-8C 100 to 120 VAC: 200 to 240 VAC: 24 VAC: 24 VDC: Control outputs 2 Approx. 3 VA (1.3 W) at 120 VAC Approx. 5 VA (1.5 W) at 240 VAC Approx. 1.2 VA (0.9 W) at 24 VAC Approx. 0.8 W at 24 VDC Approx. 3 VA (1.1 W) at 120 VAC Approx. 5 VA (1.3 W) at 240 VAC Approx. 1.3 VA (1 W) at 24 VAC Approx. 0.9 W at 24 VDC H3JA-8A: 7 A at 250 VAC, resistive load H3JA-8C: 5 A at 250 VAC, resistive load H3JA H3JA Characteristics Accuracy of operating time Setting error Influence of voltage Influence of temperature Insulation resistance 2% max. 7% max. 2% max. 5% max. 100 MW min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between contact-carrying and control circuit, and between contacts of different poles) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Impulse withstand voltage 3 kV (between power terminals) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) Noise immunity 1.5 kV (between power terminals) and 1.5 kV (between output terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 m s, 1-ns rise) Static immunity Destruction: 8 kV Malfunction: 6 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each. Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each. Shock resistance Destruction: 1,000 m/s2 Malfunction: 100 m/s2 Ambient temperature Operating: Storage: -10 C to 55 C -25 C to 65 C Ambient humidity Operating: 35% to 85% Life expectancy H3JA-8A Mechanical: Electrical: H3JA-8C Mechanical: Electrical: EMC 10,000,000 operations min. 60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h) 10,000,000 operations min. 100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h) (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN55011 Group 1 class A EN55011 Group 1 class A EN61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3) 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3) 1 kV differential mode (level 3) Approved standard UL508, CSA C22.2 No. 14, conforms to EN61812-1 Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight H3JA-8A: Approx. 50 g H3JA-8C: Approx. 60 g 3 H3JA H3JA Engineering Data H3JA-8C Switching operations (x 10 3 ) Switching operations (x 10 3 ) H3JA-8A 5,000 30 VDC resistive load 1,000 120 VAC resistive load 500 100 30 VDC inductive load L/R=7 ms 120 VAC inductive load cosf=0.4 50 0 1 2 3 250 VAC resistive load 4 5 6 f 7 Load current (A) Load current (A) Operation Timing Chart H3JA-8A 100 ms min. Rt Terminals (2)-(7) (power) Set time Set time (6)-(8) (NO) (5)-(8) (NC) Time UP indicator (Orange) Power ON indicator (Green) 100 ms min. H3JA-8C Rt Terminals (2)-(7) (power) Set time Set time (1)-(3) (NO) (6)-(8) (1)-(4) (5)-(8) (NC) Time UP indicator (Orange) Power ON indicator (Green) 4 H3JA H3JA Dimensions Note: All units are in millimeters unless otherwise indicated. 7 36 LED 36 60 14.2 4 0.7 30.5 32.8 Accessories (Order Separately) Flush Mounting Adapter Y92F-31 Adapter Y92F-31 shown with H3JA-8@ and back connecting socket. Panel Cutout Recommended panel thickness: 1 to 5 mm 15.5 US08 46 40 13 44 US08 Connecting Socket 37.4 22 91.3 11 Track Mounting/Front Connecting Socket PF085A Eight, M3.5 7 sems Terminal Arrangement (Top View) Mounting Holes Two, M4 or 4.5 dia. holes Mounting Height of Timer with Socket Two, 4.5 dia. holes H3JA Note: PF085A can be used as a front connecting socket. Hold-down Clips (Set of Two Clips) Y92H-6 for PF085A Socket 5 H3JA H3JA Back Connecting Socket US08 US08 H3JA + Adapter P3G-08 11 Terminal Arrangement (Bottom View) 91.3 (When Y92A-48G mounted) P3G-08 H3JA + Adapter 4.9 17 11 78.6 85.1 Finger Safe Terminal Cover Conforming to VDE0106/P100 Twelve, 6.4 dia. holes Y92A-48G (Attachment for P3G-08 Socket) 34 48 x 48 47.7 x 47.7 16.5 24.6 27.6 47.4 Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.30.15 4.5 4.5 350.3 15 25 25 10 25 1,000 (500) (see note) 25 10 15 (5) (see note) Note: The values shown in parentheses are for the PFP-50N. 6 350.3 270.15 1 15 25 10 25 15 25 25 1,000 10 27 24 29.2 1 1.5 H3JA H3JA End Plate PFP-M Spacer PFP-S 10 16 12 5 6.2 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Installation Terminal Arrangement H3JA-8A H3JA-8C 7 H3JA H3JA ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L100-E1-1A In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku Kyoto, 600-8530 Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189 8 Printed in Japan 0401-2M (1100) (A) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: H3JA-8C AC24 10S H3JA-8C AC200-240 60S H3JA-8A AC100-120 3M H3JA-8C DC24 30M H3JA-8A AC200-240 5M H3JA-8A AC24 10S H3JA-8C DC24 3S H3JA-8C AC24 60S H3JA-8A DC24 30S H3JA-8A AC24 5S H3JA-8A AC100-120 5M