60 Hz MCR Hardwired Series Mechanical Dimensions Phone: (800) 377-4384 FAX: (800) 367-4384 www.solaheviduty.com OUTLINE "A" OUTLINE "B" OUTLINE "C" OUTLINE "D" Notes: For Outline "C", the terminal block is located in the right unit. Use only the knockouts marked "X". For Outline "D", the terminal block is located in the center unit. Use only the knockouts marked "X". Weights and Physical Dimensions (inches) CATALOG NUMBER 63-23-112-4 63-23-125-4 63-23-150-8 63-23-175-8 63-23-210-8 63-23-215-8 63-23-220-8 63-23-230-8 63-23-250-8 VA OUTLINE A B C D E F 120 250 500 750 1,000 1,500 2,000 3,000 5,000 A A A A A B B B B 8.81 10.25 12.87 13.87 17.10 16.74 17.58 18.96 28.53 5.19 7.56 6.50 6.50 6.50 9.27 9.27 9.27 9.27 3.47 4.75 8.12 8.12 8.12 10.56 10.56 10.56 10.56 4.00 5.63 9.00 9.00 9.00 12.75 12.75 12.75 12.75 3.50 4.75 8.12 8.12 8.12 11.75 11.75 11.75 11.75 3.16 4.12 5.62 5.62 5.62 3.00 3.88 5.25 8.25 2.44 3.03 3.06 3.06 5.25 5.19 5.19 5.19 8.88 .22x.59 .31x.69 .38x.81 .38x.81 .38x.81 .44x.69 .44x.69 .44x.69 .44x.69 WEIGHT (LBS) 15 27 37 52 62 95 109 142 222 63-28-275-8 63-28-310-8 63-28-315-8 7,500 10,000 15,000 C C D 26.91 28.53 28.85 9.27 9.27 9.65 23.55 23.55 35.56 25.81 25.81 38.25 24.81 24.81 37.22 6.62 8.25 8.25 8.88 8.88 8.88 .44x.69 .44x.69 .56x.69 362 446 710 G H All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50C. If an enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and maintain an acceptable temperature. * -C8 add .17 to "B" Sola/Literature/Manuals/MCR Series/Mechanical Dimensions/MDMCR60 (12/02) Weights and Physical Dimensions (inches) CATALOG NUMBER 63-31-150-8 63-32-210-8 63-32-220-8 63-32-230-8 63-29-250-8 VA OUTLINE A B C D E F 500 1,000 2,000 3,000 5,000 A A B B B 12.87 17.10 17.58 18.96 28.53 6.50 6.50 9.27 9.27 9.27 8.12 8.12 10.56 10.56 10.56 9.00 9.00 12.75 12.75 12.75 8.12 8.12 11.75 11.75 11.75 5.62 5.62 3.88 5.25 8.25 3.06 5.25 5.19 5.19 8.88 .38x.81 .38x.81 .44x.69 .44x.69 .44x.69 WEIGHT (LBS) 37 62 109 142 222 63-29-275-8 63-29-310-8 63-29-315-8 7,500 10,000 15,000 C C D 26.91 28.53 28.85 9.27 9.27 9.65 23.55 23.55 35.56 25.81 25.81 38.25 24.81 24.81 37.22 6.62 8.25 8.25 8.88 8.88 8.88 .44x.69 .44x.69 .56x.69 362 446 710 G H All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50C. If an enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and maintain an acceptable temperature. * -C8 add .17 to "B" Sola/Literature/Manuals/MCR Series/Mechanical Dimensions/MDMCR60 (12/02)