Sola/Literature/Manuals/MCR Series/Mechanical Dimensions/MDMCR60 (12/02)
Phone: (800) 377-4384
FAX: (800) 367-4384
www.solaheviduty.com
60 Hz MCR
Hardwired Series
Mechanical Dimensions
OUTLINE “A” OUTLINE “B” OUTLINE “C” OUTLINE “D”
Notes: For Outline “C”, the terminal block is located in the right unit. Use only the knockouts marked “X”.
For Outline “D”, the terminal block is located in the center unit. Use only the knockouts marked “X”.
Weights and Physical Dimensions (inches)
CATALOG
NUMBER VA OUTLINE A B C D E F G H WEIGHT
(LBS)
63-23-112-4 120 A 8.81 5.19 3.47 4.00 3.50 3.16 2.44 .22x.59 15
63-23-125-4 250 A 10.25 7.56 4.75 5.63 4.75 4.12 3.03 .31x.69 27
63-23-150-8 500 A 12.87 6.50 8.12 9.00 8.12 5.62 3.06 .38x.81 37
63-23-175-8 750 A 13.87 6.50 8.12 9.00 8.12 5.62 3.06 .38x.81 52
63-23-210-8 1,000 A 17.10 6.50 8.12 9.00 8.12 5.62 5.25 .38x.81 62
63-23-215-8 1,500 B 16.74 9.27 10.56 12.75 11.75 3.00 5.19 .44x.69 95
63-23-220-8 2,000 B 17.58 9.27 10.56 12.75 11.75 3.88 5.19 .44x.69 109
63-23-230-8 3,000 B 18.96 9.27 10.56 12.75 11.75 5.25 5.19 .44x.69 142
63-23-250-8 5,000 B 28.53 9.27 10.56 12.75 11.75 8.25 8.88 .44x.69 222
63-28-275-8 7,500 C 26.91 9.27 23.55 25.81 24.81 6.62 8.88 .44x.69 362
63-28-310-8 10,000 C 28.53 9.27 23.55 25.81 24.81 8.25 8.88 .44x.69 446
63-28-315-8 15,000 D 28.85 9.65 35.56 38.25 37.22 8.25 8.88 .56x.69 710
All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless
special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50°C. If an
enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and
maintain an acceptable temperature.
* -C8 add .17 to “B”
Sola/Literature/Manuals/MCR Series/Mechanical Dimensions/MDMCR60 (12/02)
Weights and Physical Dimensions (inches)
CATALOG
NUMBER VA OUTLINE A B C D E F G H WEIGHT
(LBS)
63-31-150-8 500 A 12.87 6.50 8.12 9.00 8.12 5.62 3.06 .38x.81 37
63-32-210-8 1,000 A 17.10 6.50 8.12 9.00 8.12 5.62 5.25 .38x.81 62
63-32-220-8 2,000 B 17.58 9.27 10.56 12.75 11.75 3.88 5.19 .44x.69 109
63-32-230-8 3,000 B 18.96 9.27 10.56 12.75 11.75 5.25 5.19 .44x.69 142
63-29-250-8 5,000 B 28.53 9.27 10.56 12.75 11.75 8.25 8.88 .44x.69 222
63-29-275-8 7,500 C 26.91 9.27 23.55 25.81 24.81 6.62 8.88 .44x.69 362
63-29-310-8 10,000 C 28.53 9.27 23.55 25.81 24.81 8.25 8.88 .44x.69 446
63-29-315-8 15,000 D 28.85 9.65 35.56 38.25 37.22 8.25 8.88 .56x.69 710
All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless
special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50°C. If an
enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and
maintain an acceptable temperature.
* -C8 add .17 to “B”