W9959_04_LP_099-133_35 2/8/02 4:15 PM Page 104 120 Watts AA20140 Series Total Power: Input Voltage: # of Outputs: 70-120 Watts 85-264 VAC Quad Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter 90-264 VAC 47-63 Hz 40 A max., cold start @ 25C 65% typical at full load FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. 0.99 typical Power factor Safety ground Leakage current Special Features <2 mA @ 50/60 Hz, 254 VAC input Output Maximum power * * * * * * * * * Active power factor correction EN61000-3-2 compliance Remote sense on outputs one and two Industry-standard 4.25" x 7" footprint Adjustable main outputs Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense Environmental 70 W convection; 120 W with 30 CFM forced air 5% minimum on 3.3 V and 5 V outputs 15 ms @ 120 W load, 115 VAC input Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 3.3 V output: 4.25 V .25 V 5 V output: 6.25 V .75 V, 20-35% above nominal output. Latching type recycle AC to reset. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Operating temperature: 0 to 50C ambient; derate each output at 2.5% per degree from 50 to 70C Electromagnetic susceptibility: Designed to meet EN61000-4, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 20% to 90% Vibration: 5-32 Hz sinewave .02" double amplitude 32-2 kHz sinewave 1 G peak Safety Storage temperature: -40 to 85C Temperature coefficient: .04% per C MTBF per mil std 217E: >200,000 hours at full load and 30C ambient conditions and full load 104 104 America's (USA): 1-888-41-ASTEC TUV UL CUL CB CE Europe (UK): 44 (1384) 842-211 EN60950 UL1950 CSA 22.2-234 Level 3 Certificate and report Mark (LVD) 9837006 E186249 E186249 DE2-002056 Asia (HK): 852-2437-9662 W9959_04_LP_099-133_35 2/8/02 4:15 PM Page 105 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 AA20140 Series Ordering Information Model Output Minimum Maximum Load with Maximum Load with Number Voltage Load Convection Cooling 30 CFM Forced Air Load AA20140 +3.3 V +5 V +12 V -12 V 0A 1A 0.2 A 0A 8A 10 A 1A 0.5 A 16 A 20 A 2A 0.5 A 18 A 22 A 3A 1A 1. 2. 3. 4. 2 Peak Regulation 1 Ripple 3 P/P (PARD) 2% 3% 5% 10% 50 mV 50 mV 120 mV 120 mV Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. Minimum loads are required. 3.75" (95.25) 4.25" (107.95) Pin Assignments Connector GND SK1 SK1 PIN 1 PIN 3 Neutral Live SK2 PIN 1-10 PIN 11 PIN 12 PIN 13 PIN 14-17 PIN 18-22 PIN 23 PIN 24 Common +5 Sense +3.3 V Sense +12 V 5V 3.3 V Return Sense -12 V Mating Connectors (SK1) AC Input: (SK2) DC Output: 1 3 6.50" (165.10) 7.00" (177.80) Molex: 09-50-8031 (USA) Molex: 09-91-03500 (UK) PINS: 08-58-0111 Molex: Right angle 39-30-1240 or 39-29-1248 or Vertical 39-28-1243 Astec Connector Kit #70-841-013, includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance .02". 3. Warranty: 1 year 4. Weight: 1.38 lb. / .63 kg Height is 1.6" 8.50" (215.90) SK2 www.astec.com 105