53RV Series * Three-phase Motor Reversing solid-state relay; * Ratings from 25A and 50A per phase @ 48-530 VAC * Interlock Circuit Prevents Inadvertent Actuation of Both Directions * SCR output for heavy industrial loads * DC control * LED input status indicator PRODUCT SELECTION Control Voltage 4-32 VDC 25A 50A D53RV25C D53RV50C AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Maximum Load Current [Arms] (2) Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) Minimum Load Current [Arms] Maximum Surge Current 50/60 Hz (16.6ms) [Apk] 1 Second Surge Current 50/60 Hz [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum IT for Fusing (50/60 Hz, 1/2 cycle) [A sec] Thermal Resistance Junction to Case (Rjc) [C/W] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (4) UL/IEC 60947 Motor Control Ratings at 120V [HP/KW] (5) UL/IEC 60947 Motor Control Ratings at 240V [HP/KW] (5) UL/IEC 60947 Motor Control Ratings at 380V [HP/KW] (5) UL/IEC 60947 Motor Control Ratings at 480V [HP/KW] (5) D53RV25C D53RV50C 48-530 25 1100 6 0.1 475/500 100 1.35 1139/1038 0.26 500 0.75/0.56 1/0.74 2/1.48 3/2.22 48-530 50 1100 6 0.1 710/750 150 1.35 2520/2320 0.25 500 1.5/1.11 3/2.22 5/3.7 7.5/5.55 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Minimum Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current Input Resistance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] Interlocking Time [msec] Parameters 4-32 VDC 4.0 VDC 1.0 VDC 23mA 35mA Current Regulated 150 1/2 Cycle 100 GENERAL SPECIFICATIONS Description Input to Output Isolation Input/ Output to Ground Isolation Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Terminals Input Terminal Screw Torque Range:[in lbs/Nm] Output Terminal Screw Torque Range:[in lbs/Nm] Parameters 4000 Vrms 2500 Vrms 8 pF -40 to 80C -40 to 100 C 13.1 oz (370g) UL 94V0 (self extinguishing Mounted 16.8/1.9 21.2/2.4 GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) When mounted to the proper size heat sink (see derating curves) 3) Measured between 1/L1 and 2/T1 or 3/L2 and 4/T2 4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 5) At 40C Ambient temperature. THERMAL DERATE INFORMATION MECHANICAL SPECIFICATIONS AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 Rev. 120811 ANNEX - ENVIROMENTAL INFORMATION