G3VM-21PR10 MOS FET Relays Smallest Class in market, USOP Package MOS FET Relays with Low Output Capacitance and ON Resistance (CxR=2.5pF*) * Dielectric strength of 500Vrms between I/O. Note: The actual product is marked differently from the image shown here. RoHS Compliant Refer to "Common Precautions". Application Examples Terminal Arrangement/Internal Connections * Communication * Semiconductor test Model name 2PA equipment equipment OMRON mark * Data loggers * Test & measurement LOT No. 103 equipment Note: The actual product is marked differently from the image shown here. List of Models Package type Contact form Load voltage (peak value) (See note.) Terminals Minimum package quantity Model Number per tape & reel - G3VM-21PR10 USOP4 1a (SPST-NO) Surface-mounting terminals 20V G3VM-21PR10 (TR05) 500 G3VM-21PR10 (TR) 1,500 Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs. 2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. 3. The AC peak and DC value is given for the load voltages. U S O P Item LED forward current Input LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Output G 3 V M I 2 1 P R 1 0 Absolute Maximum Ratings (Ta = 25C) Continuous load current (AC peak/DC) Symbol Rating Unit IF 50 mA IF/C -0.5 mA/C VR 5 V C TJ 125 VOFF 20 V IO 200 mA Measurement conditions IO/C -2.0 mA/C Pulse ON current lop 600 mA Connection temperature TJ 125 C VI-O 500 Vrms ON current reduction rate Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Ta25C Ta25C t=100ms, Duty=1/10 AC for 1 min Ta -40~+85 C Tstg -40~+125 C With no icing or condensation - 260 C 10s With no icing or condensation Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25C) Item Symbol Minimum Typical Maximum Unit Measurement conditions VF 1.0 1.15 1.3 V IF=10mA Reverse current IR - - 10 A VR=5V Capacity between terminals CT - 15 - pF V=0, f=1MHz Trigger LED forward current IFT - 1.0 3 mA IO=100mA Maximum resistance with output ON RON - 3 5 IF=5mA, IO=200mA, t<1s Current leakage when the relay is open ILEAK - - 1 nA VOFF=20V, Ta=25C Capacity between terminals COFF - 0.8 1.1 pF V=0, f=100MHz, t<1s Capacity between I/O terminals CI-O - 0.4 - pF f=1MHz, VS=0V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O=500VDC, ROH60% Turn-ON time tON - 0.04 0.2 ms Turn-OFF time tOFF - 0.13 0.2 ms IF=5mA, RL=200, VDD=10V (See note 2.) Input LED forward voltage Output 1 Note: 2. Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF G3VM-21PR10 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD - - 16 V IF 5 7.5 20 mA Load voltage (AC peak/DC) Operating LED forward current Unit Continuous load current (AC peak/DC) IO - - 200 mA Ambient operating temperature Ta -20 - 65 C Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 60 50 40 30 20 10 250 200 150 100 -20 0 20 40 60 80 -20 0 20 40 60 80 On-state resistance RON () IF=5mA t<1s 0 -100 -300 Io=200mA 8 0.5 IF=5mA t<1s 6 4 0 -40 1 -20 0 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 60 80 100 Io=100mA t<1s 1 0 -40 -20 0 Turn ON, Turn OFF time vs. Ambient temperature 20 Turn ON, Turn OFF time tON, tOFF (s) 1000 100 tON VDD=10V RL=200 Ta=25C 1 10 100 40 60 80 100 Ambient temperature Ta (C) Current leakage vs. Load voltage tON, tOFF - Ta tOFF 1 40 1.6 2 Ambient temperature Ta (C) tON, tOFF - IF 10000 10 20 1.4 IFT - Ta 10 U S O P ILEAK - VOFF Current leakage ILEAK (pA) 0 1.2 LED forward voltage VF (V) Trigger LED forward current vs. Ambient temperature 2 -200 -0.5 1 RON - Ta Ta=25C -1 0.8 100 On-state resistance vs. Ambient temperature IO - VON 300 100 1 Ambient temperature Ta (C) Ambient temperature Ta (C) 200 10 0.1 -40 100 Continuous load current vs. On-state voltage Ta=25C 50 Trigger LED forward current IFT (mA) -40 Continuous load current IO (mA) 100 0 0 Turn ON, Turn OFF time tON, tOFF (s) IF - VF LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 1000 tOFF 100 tON 10 20 Ta=25C 15 G 3 V M I 2 1 P R 1 0 10 5 VDD=10V RL=200 IF=5mA 0 1 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (C) 0 5 10 15 20 Load voltage VOFF (v) Output terminal capacitance COFF/COFF(ov) vs. Load voltage Output terminal capacitance COFF/COFF(ov) COFF - VOFF 1 0.8 0.6 0.4 0.2 Ta=25C 0 0 5 10 15 20 Load voltage VOFF (v) Safety Precautions * Refer to "Common Precautions" for all G3VM models. 2 Apperance/Dimensions USOP4 Appearance USOP (Ultra Small Outline Package) USOP4 2PA Model name OMRON mark 103 LOT NO. Note: The actual product is marked differently from the image shown here. Dimensions 2PA (Unit: mm) Surface-mounting Terminals 103 Actual Mounting Pad Dimensions Weight: 0.03g 3.25 (Recommended Value, Top View) 2.05 0.85 2.9 0.15 1.65 (0.4) 1.27 0.2 0.8 2.85 1.27 2.2 (0.35) Note: The actual product is marked differently from the image shown here. * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K195-E1-02 1112(0912)(O)