1
G
3
V
M
2
1
P
R
1
0
I
U
S
O
P
G3VM-21PR10
MOS FET Relays
Smallest Class in market, USOP Package
MOS FET Relays with Low Output
Capacitance and ON Resistance
(CxR=2.5pF·Ω)
Dielectric strength of 500Vrms between I/O.
Application Examples
Terminal Arrangement/Internal Connections
List of Models
Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs.
2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions.
3. The AC peak and DC value is given for the load voltages.
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Note: The actual product is marked differently from the
image shown here.
RoHS Compliant
Refer to "Common Precautions".
Semiconductor test
equipment
Test & measurement
equipment
Communication
equipment
Data loggers
2PA
103
OMRON mark
Model name
LOT No.
Note: The actual product is marked differently from the image shown here.
Package type Contact form Terminals Load voltage (peak value)
(See note.) Model Minimum package quantity
Number per tape & reel
USOP4 1a
(SPST-NO) Surface-mounting terminals 20V
G3VM-21PR10
G3VM-21PR10 (TR05) 500
G3VM-21PR10 (TR) 1,500
Item Symbol Rating Unit Measurement conditions
Input
LED forward current IF50 mA
Note: 1. The dielectric strength between
the input and output was
checked by applying voltage
between all pins as a group on
the LED side and all pins as a
group on the light-receiving
side.
LED forward current reduction rate ΔIF/°C 0.5 mA/°C Ta25°C
LED reverse voltage VR5 V
Connection temperature TJ125 °C
Output
Load voltage (AC peak/DC) VOFF 20 V
Continuous load current (AC peak/DC) IO200 mA
ON current reduction rate ΔIO/°C 2.0 mA/°C Ta25°C
Pulse ON current lop 600 mA t=100ms, Duty=1/10
Connection temperature TJ125 °C
Dielectric strength between I/O
(See note 1.) VI-O 500 Vrms AC for 1 min
Ambient operating temperature Ta 40~+85 °C With no icing or condensation
Ambient storage temperature Tstg 40~+125 °C With no icing or condensation
Soldering temperature 260 °C 10s
Item Symbol Minimum Typical Maximum Unit Measurement conditions
Input
LED forward voltage VF1.0 1.15 1.3 V IF=10mA
Note: 2. Turn-ON and Turn-OFF Times
Reverse current IR−−10 μAVR=5V
Capacity between terminals CT15 pF V=0, f=1MHz
Trigger LED forward current IFT 1.0 3mA IO=100mA
Output
Maximum resistance with output ON RON 35ΩIF=5mA, IO=200mA, t<1s
Current leakage when the relay is open ILEAK −− 1nA VOFF=20V, Ta=25°C
Capacity between terminals COFF 0.8 1.1 pF V=0, f=100MHz, t<1s
Capacity between I/O terminals CI-O 0.4 pF f=1MHz, VS=0V
Insulation resistance between I/O terminals RI-O 1000 −−MΩVI-O=500VDC, ROH60%
Turn-ON time tON 0.04 0.2 ms IF=5mA, RL=200Ω,
VDD=10V (See note 2.)
Turn-OFF time tOFF 0.130.2 ms
VOUT
IF
t
ON
t
OFF
10%90%
I
F
1
2
4
3
R
L
V
DD
V
OUT
2
G3VM-21PR10 MOS FET Relays
G
3
V
M
2
1
P
R
1
0
I
U
S
O
P
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Engineering Data
Safety Precautions
Refer to "Common Precautions" for all G3VM models.
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD −−16 V
Operating LED forward current IF57.520mA
Continuous load current (AC peak/DC) IO−−200 mA
Ambient operating temperature Ta 20 65 °C
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
LED forward current vs.
LED forward voltage
Continuous load current vs.
On-state voltage
On-state resistance vs.
Ambient temperature
Trigger LED forward current vs.
Ambient temperature
Turn ON, Turn OFF time vs.
LED forward current
Turn ON, Turn OFF time vs.
Ambient temperature
Current leakage vs.
Load voltage
Output terminal capacitance
COFF/COFF(ov) vs. Load voltage
IF - Ta
Ambient temperature Ta (°C)
LED forward current IF (mA)
0
10
20
30
40
50
60
-40 0 20-20 40 60 80 100
0
IO - Ta
Ambient temperature Ta (°C)
Continuous load current IO (mA)
-40 -20 0 20 40 60 80 100
0
50
100
150
200
250
IF - VF
LED forward voltage VF (V)
LED forward current I
F
(mA)
0.1
1
10
100
0.81 1.2 1.4 1.6
Ta=25°C
IO - VON
On-state voltage VON (V)
Continuous load current IO (mA)
-300
-200
-100
0
100
200
300
-1 1-0.5 0.50
Ta=25°C
IF=5mA
t<1s
RON - Ta
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
-40 -20 0 20 40 60 80 100
0
2
4
6
8
10
Io=200mA
IF=5mA
t<1s
IFT - Ta
Ambient temperature Ta (°C)
Trigger LED forward current IFT (mA)
0
1
2
-40 -20 0 20 40 60 80 100
Io=100mA
t<1s
tON, tOFF - IF
LED forward current IF (mA)
Turn ON, Turn OFF time tON, tOFFs)
1
10
100
1000
10000
1 10 100
tON
tOFF
VDD=10V
RL=200Ω
Ta=25°C
t
ON
, t
OFF
- Ta
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFFs)
1
10
100
1000
-40 -20 0 20 40 60 80100
tON
tOFF
VDD=10V
RL=200Ω
IF=5mA
ILEAK - VOFF
Load voltage VOFF (v)
Current leakage I
LEAK
(pA)
0 5 10 15 20
0
5
10
15
20
Ta=25°C
COFF - VOFF
Load voltage VOFF (v)
Output terminal capacitance COFF/COFF(ov)
0 5 10 15 20
0
0.2
0.4
0.6
0.8
1
Ta=25°C
Apperance/Dimensions USOP4
Appearance
Dimensions (Unit: mm)
Note: The actual product is marked differently from the image shown here.
Actual Mounting Pad Dimensions
(Recommended Value, Top View)
2PA
103
USOP4
USOP (Ultra Small Outline Package)USOP (Ultra Small Outline Package)
Note: The actual product is marked differently from the image shown here.
OMRON mark
Model name
LOT NO.
3.25
2.05
2.2
2.850.2
1.27
(0.4)
(0.35)
1.65
0.15
Surface-mounting Terminals
Weight: 0.03g
2.9
0.85
0.8
1.27
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Cat. No. K195-E1-02
1112(0912)(O)
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb