PolySwitch(R) PTC Devices PRODUCT: VTP210GF DOCUMENT: SCD25823 REV LETTER: D REV DATE: JULY 26, 2016 PAGE NO.: 1 OF 2 Overcurrent Protection Device Specification Status: Released Maximum Electrical Rating Operating Voltage: 16Vdc A D C E Interrupt Current: 100A B F Leads: Nickel 1/4H 0.125mm nominal thickness R Solder: Lead-free ORIENTATION MARK(Blue) Tape: Polyester(White) 13mm nominal width Lot Marking Ink Color (Green) Marking: Manufacturer's Mark V21 Part Identification Lot Identification TABLE I. DIMENSIONS: A B MIN MAX MIN MAX mm: 20.9 23.1 4.9 5.3 in*: (0.82) (0.91) (0.19) (0.21) *Rounded off approximation C MIN --- D MAX 0.8 (0.03) MIN 4.1 (0.16) E MAX 5.8 (0.23) MIN 4.1 (0.16) F MAX 5.8 (0.23) MIN 3.9 (0.15) MAX 4.1 (0.16) R TYP MAX 1.0 -(0.4) -- TABLE II. PERFORMANCE RATINGS: As measured in Mueller Kelvin Clips Model BU-75K I HOLD CURRENT TRIP LIMITS AMPS AMPS 25C AT 0C HOLD HOLD TRIP 2.1 2.9 6.0 TIME TO TRIP REFERENCE RESISTANCE AMPS AMPS SECONDS AT OHMS AT 25C AT 60C 25C, 10.0A AT 25C HOLD TRIP HOLD TRIP MIN MAX MIN MAX 2.1 4.7 1.0 2.8 --5 0.018 0.030 Agency Recognition: Reference Document: Precedence: Effectivity: CAUTION: ONE-HOUR POST-TRIP RESISTANCE OHMS AT 25C MIN MAX 0.018 0.060 TRIPPEDSTATE POWER DISSIPATION WATTS AT 25C,16V MAX 1.5 UL, CSA, TUV PS300 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame. Materials Information ROHS Compliant ELV Compliant (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised July 26, 2016 Pb-Free littelfuse.com PolySwitch(R) PTC Devices Overcurrent Protection Device PRODUCT: VTP210GF DOCUMENT: SCD25823 REV LETTER: D REV DATE: JULY 26, 2016 PAGE NO.: 2 OF 2 Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. (c) 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised July 26, 2016 littelfuse.com