April 2011 208045-11 1
Numonyx™ Axcell™ M29EW
Datasheet
256-Mbit, 512-Mbit, 1-Gbit, 2-Gbit (x8/x16, uniform block)
3 V supply flash memory
Features
Supply voltage
—V
CC = 2.7 to 3.6 V for Program, Erase and
Read
—V
CCQ = 1.65 to 3.6 V for I/O buffers
Asynchronous Random/Page Read
Page size: 16 words or 32 bytes
Page access: 25 ns
Random access: 100ns (Fortified BGA);
110 ns (TSOP)
Buffer Program
512-word program buffer
Programming time
0.88 µs per byte (1.14MB/s) typical when
using full buffer size in buffer program
Memory organization
Uniform blocks, 128 Kbytes/64 Kwords
each
Program/Er ase controller
Embedded byte/word program algorithms
Program/ Erase Suspend and Resume
Read from any block during Program
Suspend
Read and Program another block during
Erase Suspend
Blank Check to verify an erased block
Unlock Bypass/Block Erase/Chip Erase/Write
to Buffer
Faster Buffered/Batch Programming
Faster Block and Chip Erase
Vpp/WP# pin protection
Protects first or last block regardless of
block protection settings
Software protection
Volatile Protection
Non-Volatile Protection
Password Protection
Password Access
Extended Memory block
128-word/256-byte block for permanent,
secure identification.
can be programmed and locked by factory
or by the customer
Low power consumption
Standby
Minimum 100,000 Program/Erase cycles per
block
ETOXTM* X (65nm) MLC technology
F ortified BGA and TSOP packages
JESD47E Compliant
Green packages available
—RoHS Compliant
Halogen Free
Table of Contents Numonyx™ Axcell™ M29EW
2 208045-11
1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1 Address inputs (A0-Amax) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Data inputs/outputs (DQ0-DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 Data inputs/outputs (DQ8-DQ14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4 Data input/output or address input (DQ15/A-1) . . . . . . . . . . . . . . . . . . . . 13
2.5 Chip Enable (CE#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6 Output Enable (OE#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.7 Write Enable (WE#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.8 VPP/Write Protect (VPP/WP#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.9 Reset (RST#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.10 Ready/Busy output (RY/BY#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.11 Byte/Word organization select (BYTE#) . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.12 VCC supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.13 VCCQ input/output supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.14 VSS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3 Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.3 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.4 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.5 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.6 Auto Select mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.6.1 Read electronic signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.6.2 Verify Extended Memory Block protection indicator . . . . . . . . . . . . . . . .18
3.6.3 Verify block protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.6.4 Hardware Block Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
4 Hardware Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5 Software Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1 Volatile Protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.2 Non-Volatile Protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Numonyx™ Axcell™ M29EW Table of Contents
208045-11 3
5.2.1 Non-Volatile Protection bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.2.2 Non-Volatile Protection Bit Lock bit . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.3 Password Protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6 Command Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1 Standard commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1.1 Read/Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.1.2 Auto Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.1.3 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
6.1.4 Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
6.1.5 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
6.1.6 Blank Check command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
6.1.7 Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
6.1.8 Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
6.1.9 Program Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6.1.10 Program Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6.1.11 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6.2 Fast Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.2.1 Write to Buffer Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
6.2.2 Buffered Program Abort and Reset command . . . . . . . . . . . . . . . . . . . .38
6.2.3 Write to Buffer Program Confirm command . . . . . . . . . . . . . . . . . . . . . .39
6.2.4 Unlock Bypass command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
6.2.5 Unlock Bypass Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
6.2.6 Unlock Bypass Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . .39
6.2.7 Unlock Bypass Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . .40
6.2.8 Unlock Bypass Write to Buffer Program command . . . . . . . . . . . . . . . .40
6.2.9 Unlock Bypass Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
6.3 Protection commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.3.1 Enter Extended Memory Block command . . . . . . . . . . . . . . . . . . . . . . .43
6.3.2 Exit Extended Memory Block command . . . . . . . . . . . . . . . . . . . . . . . .43
6.3.3 Lock Register command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
6.3.4 Password Protection mode command set . . . . . . . . . . . . . . . . . . . . . . .44
6.3.5 Non-Volatile Protection mode command set . . . . . . . . . . . . . . . . . . . . .45
6.3.6 NVPB Lock Bit command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
6.3.7 Volatile Protection mode command set . . . . . . . . . . . . . . . . . . . . . . . . .47
6.3.8 Exit Protection command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Table of Contents Numonyx™ Axcell™ M29EW
4 208045-11
7 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.1 Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.1.1 Password Protection Mode Lock bit (DQ2) . . . . . . . . . . . . . . . . . . . . . .52
7.1.2 Non-Volatile Protection Mode Lock bit (DQ1) . . . . . . . . . . . . . . . . . . . . .52
7.1.3 Extended Memory Block Protection bit (DQ0) . . . . . . . . . . . . . . . . . . . .52
7.2 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
7.2.1 Data Polling bit (DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
7.2.2 Toggle bit (DQ6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
7.2.3 Error bit (DQ5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
7.2.4 Erase Timer bit (DQ3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
7.2.5 Alternative Toggle bit (DQ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
7.2.6 Buffered Program Abort bit (DQ1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
8 Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
9 DC and AC Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
10 Programming and Erase Performance . . . . . . . . . . . . . . . . . . . . . . . . . 77
11 Package Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
12 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Appendix A Memory Address Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Appendix B Common Flash Interface (CFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Appendix C Extended Memory Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
C.1 Numonyx pre-locked Extended Memory Block . . . . . . . . . . . . . . . . . . . . 116
C.2 Customer-lockable Extended Memory Block. . . . . . . . . . . . . . . . . . . . . . 117
Appendix D Revision History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Numonyx™ Axcell™ M29EW List of Tables
208045-11 5
Table 1. Signal Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 2. VPP/WP# functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3. Bus operations, 8-bit mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 4. Bus operations, 16-bit mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 5. Read electronic signature - auto select mode - programmer method (8-bit mode) . . . . . . 21
Table 6. Read electronic signature - auto select mode - programmer method (16-bit mode) . . . . . 21
Table 7. Block protection - auto select mode - programmer method (8-bit mode) . . . . . . . . . . . . . . 22
Table 8. Block protection - auto select mode - programmer method (16-bit mode) . . . . . . . . . . . . . 22
Table 9. Standard commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 10. Standard commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 11. Fast Program commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 12. Fast Program commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 13. Block Protection commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 14. Block Protection commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 15. Lock Register bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 16. Block Protection Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 17. Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 18. Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 19. Operating and AC measurement conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 20. Power-up wait timings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 21. Device capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 22. DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 23. Read AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 24. Write AC characteristics, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 25. Write AC characteristics, Chip Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 26. Reset AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 27. Accelerated Program and Data Polling/Da ta Toggle AC characteristics . . . . . . . . . . . . . . 76
Table 28. Programming and Erase Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Table 29. TSOP56 – 56 lead thin small-out line package, 14 x 20 mm, package mechanical data . . 78
Table 30. Fortified BGA64 11 x 13 mm - 8 x 8 active ball array, package mechanical data. . . . . . . . 79
Table 31. Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Table 32. Valid Combinations of M29EW Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit) . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Table 34. Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Table 35. CFI query identification string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Table 36. CFI query system interface information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Table 37. Device geometry definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Table 38. Primary algorithm-specific extended query table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Table 39. Extended Memory Block address and data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Table 40. Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
List of Figures Numonyx™ Axcell™ M29EW
6 208045-11
Figure 1. Logic diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 2. 2-Gbit (1-Gbit/1-Gbit stack) configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 3. TSOP connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 4. Fortified BGA connections (top and bottom views). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 5. Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 6. Software protection scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 7. Boundary condition of program buffer size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 8. Write to Buffer Program fletcher and pseudo code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 9. NVPB Program/Erase algorithm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 10. Lock Register program flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 11. Data polling flow chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 12. Toggle flow chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 13. Status Register Polling Flow Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 14. AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 15. AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 16. Power-up wait timings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 17. Random Read AC waveforms (8-bit mo de) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 18. Random Read AC waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 19. BYTE# Transition AC Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 20. Page Read AC waveforms (16-bit mode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 21. Write Enable Controlled Program waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 22. Write Enable Controlled Program waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 23. Chip Enable Controlled Program waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 24. Chip Enable Controlled Program waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 25. Chip/Block Erase waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 26. Reset AC waveforms (no program/erase in progress) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 27. Reset during program/erase operation AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 28. Accelerated program timing waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 29. Data polling AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 30. Toggle/Alternative Toggle bit polling AC waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . 76
Figure 31. TSOP56 – 56 lead thin small-outline package, 14 x 20 mm, package outline . . . . . . . . . . 78
Figure 32. Fortified BGA64 11 x 13 mm - 8 x 8 active ball array, package outline . . . . . . . . . . . . . . . 79
Numonyx™ Axcell™ M29EW Description
208045-11 7
1 Description
The Numonyx™ Axcell™ M29EW flash memory based on 65nm MLC technology is the
world’s leading line of parallel NOR flash for embedded applications. It can be read, erased
and reprogrammed; and these operations can be performed using a single low voltage (2.7
to 3.6 V) supply. Upon power-up, the memory defa ults to its array read mode.
The main memory array is divided into 64-Kword/128-Kbyte uniform blocks that ca n be
erased inde pendently so th at v alid data can be pre serv ed while old data is purged. Progr am
and Erase commands are written to the command interface of the memory. An on-chip
Program/Erase controller simplifies the process of prog ramming or erasing the memory by
taking care of all o f the sp ecial operations that are re quired to updat e the mem ory contents.
The end of a program or erase operation can be detected and any error condition can be
identified. The command set required to control the memory is consistent with JEDEC
standards.
Chip Enable, Output Enable and Write Enable signals control the bus operation of the
memory. They allow simple connection to most microprocessors, often without additio nal
logic.
The M29EW supports Asynchronous Random Read and Page Read from all blocks of the
memory array. It also features an internal program buffer which improves throughput by
programming 512 words via one command sequence.
The M29EW contains a 128-word Extended Memory Block which overlaps addresses with
array block 0. The user can program this additional space; then protect it to permanently
secure its contents.
The device features different levels of hardware and software protection to secure blocks
from unwanted modification (program or erase):
lHardware pr ot ect ion :
–The V
PP/WP# provides a hardware protection of eit he r th e h ig he st (M 2 9EWH) or
the lowest (M29EWL) block of the main memory array.
lSoftware protection:
Volatile Protect ion
Non-Volatile Protection
Password Protection
Pass word Access
The M29EW is offered in TSOP56 (14 x 20 mm) and Fortified BGA64 (11 x 13 mm, 1 mm
pitch) packages.
The memories are delivered with all the bits erased (set to ‘1’).
Also see Appendix B: Common Flash Interface (CFI) on page 112 and Table 5: Block
addresses on page 12 for a full list of the block addresses.
Description Numonyx™ Axcell™ M29EW
8 208045-11
Figure 1. Logic diagram
1. A23 is valid for 256-Mbit density and above; otherwise, it is RFU.
2. A24 is valid for 512-Mbit density and above; otherwise, it is RFU.
3. A25 is valid for 1-Gbit density and above; otherwise, it is RFU.
4. A26 is valid for 2-Gbit (1-Gbit/1-Gbit stack) density only; otherwise it’s RFU.
5. RFU stands for Reserved for Future Use and should be not connect.
Table 1. Signal Descriptions
Name Description Direction
A0-Amax Address inputs Inputs
DQ0-DQ7 Data inputs/outputs I/O
DQ8-DQ14 Data inputs/outputs I/O
DQ15/A1 Data input/output or address input I/O
CE# Chip Enable Input
OE# Output Enab le Input
WE# Write Enab le Input
RST# Reset Input
RY/BY# Ready/Busy output Output
BYTE# Byte/word organization select Input
VCCQ Input/output buffer supply voltage Supply
VCC Supply voltage Supply
VPP/WP#(1) VPP/Write Protect Input
VSS Ground -
NC Not connected -
1. VPP/WP# may be left unconnected as it is internally connected to a pull-up resistor, which enables Program/Erase operations.
M29EW
V
CC
V
CCQ
A0 – Amax
WE#
V
PP
/WP#
DQ0 – DQ14
DQ15 / A-1
V
SS
15
CE#
OE#
RST#
BYTE#
RY/BY#
Numonyx™ Axcell™ M29EW Description
208045-11 9
Figure 2. 2-Gbit (1-Gbit/1-Gbit stack) configurations
1. Amax = VIH selects the Upper Die; Amax = VIL selects the Lower Die.
Upper Die
(1-Gbit)
Lower Die
(1-Gbit)
VPP/WP#
CE#
BYTE#
OE#
WE#
RST#
VCC
DQ[14:0]
A[26:0]
VCCQ
VSS
2-Gbi t (1-Gbi t /1-Gbi t stack) Confi gurati on
DQ15/A-1
RY/BY#
Description Numonyx™ Axcell™ M29EW
10 208045-11
Figure 3. TSOP connections
1. A-1 is the least significant address bit in x8 mode.
2. A23 is valid for 256-Mbit density and above; otherwise, it is RFU.
3. A24 is valid for 512-Mbit density and above; otherwise, it is RFU.
4. A25 is valid for 1-Gbit density and above; otherwise, it is RFU.
5. A26 is valid for 2-Gbit (1-Gbit/1-Gbit stack) density only; otherwise it’s RFU.
6. RFU stands for Reserved for Future Use and should be not connect.
56-Lead TSOP
Standard Pi nout
14 mm x 20 mm
Top View
1
3
4
2
5
7
8
6
9
11
12
10
13
15
16
14
17
19
20
18
21
23
24
22
25
27
28
26
56
54
53
55
52
50
49
51
48
46
45
47
44
42
41
43
40
38
37
39
36
34
33
35
32
30
29
31
A23
A21
A20
CE#
A19
A17
A16
A18
VCC
A14
A13
A15
A12
VPP/WP#
A11
A9
A8
A10
A6
A5
A7
A4
A2
A1
A3
OE#
RST#
WE#
DQ15 / A-1
DQ14
DQ6
DQ7
VSS
DQ5
DQ12
DQ13
DQ4
VSS
DQ11
VCCQ
DQ3
DQ2
DQ10
DQ9
DQ8
DQ0
DQ1
A0
A22
BYTE#
RY/BY#
A26
RFU RFU
A25
A24
Numonyx™ Axcell™ M29EW Description
208045-11 11
Figure 4. Fortified BGA connections (top and bottom views)
1. A-1 is the least significant address bit in x8 mode.
2. A23 is valid for 256-Mbit density and above; otherwise, it is RFU.
3. A24 is valid for 512-Mbit density and above; otherwise, it is RFU.
4. A25 is valid for 1-Gbit density and above; otherwise, it is RFU.
5. A26 is valid for 2-Gbit (1-Gbit/1-Gbit stack) density only; otherwise it’s RFU.
6. RFU stands for Reserved for Future Use and should be not connect.
RFU
18
234567
F o rtifi e d BGA
Top Vi ew - Bal l sid e down F o rtifi e d BGA
Bottom Vi ew- Ball side up
1
8234
5
67
H
G
F
E
D
C
B
A
RFUA1A5A19 A20A15Vccq A11
RFUA3A7WE# RY/BY#A13RFU A9
RFUA2A6A21 A18A14A23 A10
Vss RFUA0D0D5 D2A16 D7
VccqD8D12 D10BYTE# D14
D9Vcc D11D13
H
G
F
E
D
C
B
A
A26A4A17RST# Vpp/
WP#
A12A22 A8A26 A4 A17 RST#
Vpp/
WP# A12 A22A8
RFU Vss D1 D4D3 Vss RFUD6 RFUVssD1D4 D3VssRFU D6
RFU A2 A6 A21A18 A14 A23A10
RFU A1 A5 A19A20 A15 VccqA11
VssRFU A0 D0 D5D2 A16D7
Vccq CE# D8 D12D10 BYTE#D14
RFU OE# D9 VccD11 D15/
A-1
D13
RFU A3 A7 WE# A13 RFUA9
A24
A25 D15/
A-1
CE#
OE#
RY/BY#
A24
A25
Description Numonyx™ Axcell™ M29EW
12 208045-11
Figure 5. Block addresses
64-KW Array Block
64-KW Array Block
64-KW Array Block
001FFFFh
0010000 h
000FFFFh
0000000 h
128-KB Array Block
128-KB Array Block
128-KB Array Block
3FFFFFFh
3FE0000 h
003FFFFh
0020000 h
001FFFFh
0000000 h
A[2 6:-1] 2-G bit
A[2 5:-1] 1-G bit
A[24:-1] 512-Mbit
A[23:-1] 256-Mbit
64-KW Array Block128-KB Array Block
1
0
511
255
1
0
511
255
512-Mbit
64-KW Array Block128-KB Array Block 3FFFFFFh
3FF0000 h
7FFFFFFh
7FE0000 h 1023 1023
1-Gbit
A[26:0 ] 2-Gbit
A[25:0 ] 1-Gbit
A[24:0 ] 512-Mbit
A[23:0 ] 256-Mbit
256-Mbit
1FFFFFFh
1FF0000 h
0FFFFFFh
0FF0000 h
1FFFFFFh
1FE0000 h
64-KW Arra y Block128-KB Array Block 7FFFFFFh
7FF0000 h
FFFFFFFh
FFE0000 h 2047 2047
2-Gbit
Numonyx™ Axcell™ M29EW Signal Descriptions
208045-11 13
2 Signal Descriptions
See Figure 1: Logic diagram, and Ta ble 1: Signal Descriptions , for a brief overview of the
signals connected to this device.
2.1 Address inputs (A0-Amax)
The Address inputs select the cells in the memory array to access during Bus Read
operations. During Bus Write operations they control the commands sent to the command
interface of the Program/Erase controller.
2.2 Data inputs/outputs (DQ0-DQ7)
The Data I/O outputs the data stored at the selected address during a Bus Read operation.
During Bus Write operations they represent the comm ands sent to the command interface
of the internal state machine.
2.3 Data inputs/outputs (DQ8-DQ14)
The Data I/O outputs the data stored at the selected address during a Bus Read operation
when BYTE# is High, VIH. When BYTE# is Low, VIL, these pins are not used and are high
impedance. During Bus Write operations the Command Register do es not use these bits.
When reading the Status Register these bits should be ignored.
2.4 Data input/output or address input (DQ15/A1)
When the device operates in x16 bus mode, this pin behaves as a Data input/output pin,
together with DQ8-DQ14. When the device operates in x8 bus mode, this pin behaves as
the least significant bit of the address. Throughout the text consider references to the Data
input/output t o include this p in when the d e vice oper ates in x16 b us mod e and references to
the Address inputs t o include this pin wh en the de vice operat es in x8 b us mode e xcept when
stated explicitly otherwise.
2.5 Chip Enable (CE#)
The Chip Enab le pin, CE#, activat es the memory, allowing Bus Read and Bus Write
operations t o be performed. When Chip Enable is High, VIH, all other pins are ignored.
2.6 Output Enable (OE#)
The Output Enable pin, OE#, contr ols the Bus Read operation of the memory.
Signal Descriptions Numonyx™ Ax cell™ M29EW
14 208045-11
2.7 Write Enable (WE#)
The Write Enable pin, WE#, controls the Bus Write operation of the memory’s command
interface.
2.8 VPP/Write Protect (VPP/WP#)
The VPP/Write Protect pin provides two functions, Write Protect function and the VPPH
function, which prot ect the lowest or highest block and allow the memory to enter unlock
by pass mode respectiv ely.
The Write Protect function provides a hardware method of protecting the highest or lowest
bloc k (see Section 1: Description). When VPP/Write Protect is Low, VIL, the highest or lo west
bl ock is protected. Prog ram and Erase opera tio ns on this bloc k are ign ored wh ile VPP/Write
Protect is Low.
When VPP/Wr ite Protect is High, VIH, th e memory reverts to the previous protection status
of the highest or lowest block. Program and Erase operations can now modify the data in
this block unless the block is protected using Block prot ection.
When VPP/Write Protect is raised to VPPH the memory automatically enters the Unlock
Bypass mode (see Section 6.2.4).
When VPP/Write Protect returns to VIH or VIL normal operation resumes . See the description
of the Unlock Bypass command in the command interface section. The transitions from VIH
to VPPH and from VPPH to VIH must be slower than t VHVPP (see Figure 28: Accelerated
program timing waveforms).
Never raise VPP/Write Protect to VPPH from any mode except Read mode, otherwise th e
memory may be left in an indeterminate state. A 0.1 µF capacitor should be connected
between the VPP/Write Protect pin and the VSS ground pin to decouple the curren t surges
from the power supply. The PCB track widths must be sufficient to carry the currents
required during Unlock Bypass Program (se e I PP1, IPP2, IPP3, IPP4 in Table 22: DC
characteristics).
The VPP/Write Protect pin may be left unconnected as it features an internal pull-up resistor.
Note: For 2-Gbit (1-Gbit/1-Gbit stack) device, When VPP/WP# pin is low, both the highest block
and the lowest block are hardware-protected, namely bl ock 0 and block 2047.
Refer to Table 2 for a summary of VPP/WP# functions.
Table 2. VPP/WP# functions
VPP/WP# Function
VIL Highest block protected or lowest block protected.(1)
VIH Highest and lowest block unprotected unless a software protection is activated (see
Section 4: Hardware Protection).
VPPH Unlock bypass mode.
1. For 2-Gbit (1-Gbit/1-Gbit stack) device, both the highest block and the lo west b lock are hardware-protected, namely b lock 0
and block 2047.
Numonyx™ Axcell™ M29EW Signal Descriptions
208045-11 15
2.9 Reset (RST#)
The Reset pin can be used to apply a Hardw are Reset to the me mory. A Hardw are Reset is
achieved by holding Reset Low, VIL, for at least tPLPX. After Reset goes High, VIH, the
memor y will be ready for Bus Read and Bus Write operations after tPHEL or tRHEL,
whichever occurs last. See Section 2.10: Ready/Busy output (RY/BY#), Table 26: Reset AC
characteristics, Figure 26 and Figure 27 f or more details.
2.10 Ready/Busy output (RY/BY#)
The Ready/Busy pin is an open-drain output that can be used to identify when the device is
performing a program or erase operation. During program or erase operations Ready/Busy
is Low, VOL (see Table 17: Status Register bits). Ready/Busy is high-impedance during
Read mode, Auto Select mode and Erase Suspend mode.
After a Hardw are Reset, Bus Read and Bus Write oper ations cannot beg in until Ready/Busy
becomes high-impedance. See Table 26: Reset AC characteristics, Figure 26 and
Figure 27.
The use of an open-drain output allows the Ready/Busy pins from several memories to be
connected to a single pull-up resistor. A low v alue will then indicate that one , or more , of the
memories is busy. The 10Kohm or bigger resistor is recommended as pull-up resist or to
achieve 0.1V VOL.
2.11 Byte/Word organization select (BYTE#)
The BYTE# pin is used to switch between the x8 a nd x16 Bu s mod es of t he memo ry. When
Byte/Word organization select is Low, VIL, the memory is in x8 mode, when it is High, VIH,
the memory is in x16 mode.
2.12 VCC supply voltage
VCC provides the power supply for all operations (Read, Program and Erase). The
command interface is disabled when the VCC supply voltage is less than the Lockout
vo lt age, VLKO. This prevents Bus Write operations from accidentally damaging the data
during power-up, power-down and power surges. If the Program/Erase controller is
progr amming or erasin g during this time then th e operation abo rts and the memory contents
being altered will be invalid.
A 0.1 µF capacitor should be connected bet ween the VCC supply voltage pin and the VSS
ground pin to decouple the current surges from the power supply. The PCB track widths
must be suf ficient to carry the curr ents required during program and erase operations (see
ICC1, ICC2, ICC3 in Table 22: DC characteristics).
2.13 VCCQ input/output supply voltage
VCCQ provides the power supply to the I/O pins and enables all outputs to be powered
independently fr om VCC.
Signal Descriptions Numonyx™ Ax cell™ M29EW
16 208045-11
2.14 VSS ground
VSS is the ref erence for a ll voltag e measurements . The de vice f eatures two VSS pins; both of
which must be connected to the system ground.
Numonyx™ Axcell™ M29EW Bus Operations
208045-11 17
3 Bus Operations
There are five standard bus operations that control the device. These are Bus Read
(Random and Page modes), Bus Write, Output Disable and Standby.
See Table 3: Bus operations, 8-bit mode and Table 4: Bus operations, 16-bit mode for a
summary. Typical glitches of less than 3ns on Chip Enable, Write Enable, and Reset pins
are ignored by the memory and do not affect bus operations.
3.1 Bus Read
Bus Read operations read from the memory cells, or specific re gisters in the command
interface. To speed up the read operation the memory array can be read in P age mode
where data is internally read and stored in a page buffer. The page has a size of 16 words
(or 32b ytes) and is addr essed by the address inputs A3-A0 in x16 b us mode and A3 -A0 plus
DQ15/A1 in x8 bus mode.The page read mode is not supported for reading Extended
Memory Blocks and CFI information.
A valid Bus Read operation inv olves setting the desired address on the Address inputs,
applying a Low signal, VIL, to Chip Enable and Output Enable and keeping Write Enable
High, VIH. The Data inputs/outputs will output the value, see Figure 17: Random Read AC
waveforms (8-bit mode), Figure 20: Page Read AC waveforms (16-bit mode), and Table 23:
Read AC characteristics, for details of when the output becomes valid.
3.2 Bus Write
Bus Write operations write to the comm and interface. A v alid Bus Write oper ation b egins by
setting the desired address on the Address inputs. The Addre ss inputs are latched by the
command interface on the falling edge of Chip Enable or Write Enable, whichever occurs
last. The Data inputs/outputs are latched by the command interface on the rising edge of
Chip Enable or Write Enable, whichever occurs first. Output Enable must remain High, VIH,
durin g the who le Bu s Write operation. See Figure 21, and Figure 22, Wr ite AC waveforms,
and Table 24 and Table 25, Write AC characteristics, for details of the timing requirements.
3.3 Output Disable
The Data inputs/outputs are in the high impedance state when Output Enable is High, VIH.
3.4 Standby
Driving Chip Enable High in Read mode, causes the memory to enter Standby mode and
the data inputs/outputs pins are placed in the high-impedan ce state. To reduce the Supply
current to the St andby Supply current, ICC2, Chip Enable should be held within VCC ±0.3V.
For the Standby current lev el see Table 22: DC characteristics.
During program or erase operations the memory will continue to use the Program/Erase
Supply current, ICC3, for Program or Erase operations until the operation completes.
Bus Operations Numonyx™ Axcell™ M29EW
18 208045-11
3.5 Reset
During Reset mode the memory is deselected and the outputs are high impedance. The
memory is in Reset mode when RST# is at VIL. The power consumption is reduced to the
standby level, independently from the Chip Enable, Output Enable or Write Enable inputs.
3.6 Au to Select mode
The Auto Select mode allows the system or the programming equipment to read the
electronic signature, verify the protection st atus of the Extended Memory Block, and
apply/remove Block protect i on . For example, this mode can be use d by programming
equipment to automatically match a device and the application code to be programmed.
At power-up, the device is in Read mode, and can then be put in Auto Select mode by
issuing the Auto Select command (see Section 6.1.2).
The device cannot enter Auto Select mode when a program or erase operation is in
progress (RY/BY# Lo w). How e v er, A uto Select m ode can be en tered if the p rogr am or er ase
operat ion has been suspended b y issuing a Progr am Suspend or Era se Suspend command
(see Section 6.1.7).
The A uto Select mode is e xited b y perf orming a reset. The de vice is returned to Read mode,
e xcep t if the Auto Select mode was entered aft er an Er ase Su spend or a Prog r am Suspend
command. In this case, it returns to the Erase or Progr am Suspend mode.
3.6.1 Read electronic signature
The memory has two codes , the manuf actu rer code and the de vice code used to id entify the
memory. These codes can be accessed b y performing read operations with control signals
and addresses set as shown in Table 5: Read electronic signature - auto select mode -
progr ammer me thod (8-bit mode) and Tab le 6: Read electronic sign ature - auto select mod e
- programmer method (1 6- bit mode).
These codes can also be accessed b y issuin g an A uto Select co mmand (see Section 6.1.2:
Auto Select command).
3.6.2 Verify Extended Memory Block protection indicator
The Extended Memory Block is either Numonyx pre-locked or customer-lockable.
The protection status of t he Extend ed Me mory Block (pr e-locked or customer- l ockable) can
be accessed by reading the Extended Memory Block protection indicator. It can be read in
Auto Select mode using either the programme r (see Table 7 and Table 8) or the in-system
method (see Table 9 and Table 10).
The protection status of the Extended Memory Block is th en output on bit DQ7 of the Data
input/outputs (see Table 3 and Table 4, Bus operations in 8-bit and 16-bit mode).
3.6.3 Verify block protection status
The protection status of a block can be determined by perfor ming a read operation with
control signals and addresses set as shown in Table 7 and Table 8.
If the block is protected, then 01h (in x 8 mode) is output on Data input/outputs DQ0-DQ7,
otherwise 00h is output.
Numonyx™ Axcell™ M29EW Bus Operations
208045-11 19
3.6.4 Hardware Block Protect
The VPP/WP# pin can be us ed to protect the highest or lowest block. When VPP/WP# is at
VIL, the highest block (M29EWH) or the lowest block (M29EWL) is pr otected and the other
blocks remain with their own protection status.
Bus Operations Numonyx™ Axcell™ M29EW
20 208045-11
M
Table 3. Bus operations, 8-bit mode
Operation(1) CE# OE# WE# RST# VPP/WP# Address In put s Data Inputs/Outputs
Amax-A0, DQ15/A-1 DQ14-DQ8 DQ7-DQ0
Bus Read VIL VIL VIH VIH X Cell address H i-Z Data output
Bus Write VIL VIH VIL VIH VIH(2) Command address Hi-Z Data input(3)
Standby VIH XXV
IH VIH X Hi-Z Hi-Z
Output Disable VIL VIH VIH VIH X X Hi-Z Hi-Z
Reset X X X VIL X X Hi-Z Hi-Z
1. X = VIL or VIH.
2. If WP# is Low, VIL, the outermost block remains protected.
3. Data input as required when issuing a command sequence, performing data polling or block protection.
Table 4. Bus operations, 16-bit mode
Operation(1) CE# OE# WE# RST# VPP/WP# Address Inputs Data Inputs/Outputs
Amax-A0 DQ15/A-1, DQ14-DQ0
Bus Read VIL VIL VIH VIH X Cell address Data output
Bus Write VIL VIH VIL VIH VIH(2) Command address Data input(3)
Standby VIH XXV
IH VIH X Hi-Z
Output Disable VIL VIH VIH VIH X X Hi-Z
Reset X X X VIL X X Hi-Z
1. X = VIL or VIH.
2. If WP# is Low, VIL, the outermost block remains protected.
3. Data input as required when issuing a command sequence, performing data polling or block protection.
Numonyx™ Axcell™ M29EW Bus Operations
208045-11 21
Table 5. Read electronic signature - auto select mode - programmer method (8-bit mode)
Read
cycle(1) CE# OE# WE# Address inputs Data inputs/outputs
Amax-A4 A3 A2 A1 A0 DQ15/A-1 DQ14-DQ8 DQ7-DQ0
Manufacturer
code
VIL VIL VIH VIL
VIL VIL VIL VIL XX 89h
Device code
(cycle 1) VIL VIL VIL VIH XX 7Eh
Device code
(cycle 2) VIH VIH VIH VIL XX
22h (256-Mbit)
23h (512-Mbit)
28h (1-Gbit)
48h (2-Gbit)
Device code
(cycle 3) VIH VIH VIH VIH XX 01h
1. X = VIL or VIH.
Table 6. Read electronic signature - auto select mode - programmer method (16-bit mode)
Read
cycle(1) CE# OE# WE# Address inputs Data inputs/outputs
Amax-A4 A3 A2 A1 A0 DQ15/A-1, DQ14-DQ0
Manufacturer
code
VIL VIL VIH VIL
VIL VIL VIL VIL 0089h
Device code
(cycle 1) VIL VIL VIL VIH 227Eh
Device code
(cycle 2) VIH VIH VIH VIL
2222h (256-Mbit)
2223h (512-Mbit)
2228h (1-Gbit)
2248h (2-Gbit)
Device code
(cycle 3) VIH VIH VIH VIH 2201h
1. X = VIL or VIH.
Bus Operations Numonyx™ Axcell™ M29EW
22 208045-11
Table 7. Block protection - auto select mode - programmer method (8-bit mode)
Operation(1) CE# OE# WE#
Address inputs Data inputs/outputs
Amax-A16 A15-A2 A1 A0 DQ15/A-1 DQ14
-DQ8 DQ7-DQ0
Verify
Extended
Memory
Block
protection
indicator
(bit DQ7)
M29EWL
VIL VIL VIH
VIL VIL VIH
VIH XX
89h (Numonyx pre-
locked)
09h (customer-
lockable)
M29EWH
99h (Numonyx pre-
locked)
19h (customer-
lockable)
Verify block protection
status BBA VIL 01h (protected)
00h (unprotected)
1. X = VIL or VIH. BBA = Block Base Address.
Table 8. Block protection - auto select mode - programmer method (16-bit mode )
Operation(1) CE# OE# WE# Address inputs Data inputs/outputs
Amax-A16 A15-A2 A1 A0 DQ15/A-1, DQ14-DQ0
Verify
Extended
Memory
Block
indicator
(bit DQ7)
M29EWL
VIL VIL VIH
VIL VIL VIH
VIH
0089h (Numonyx pre-
locked)
0009h (customer-lockable)
M29EWH 0099h (Numonyx pre-
locked)
0019h (customer-lockable)
Verify block protection
status BBA VIL 0001h (protected)
0000h (unprotected)
1. X = VIL or VIH. BBA = Block Base Address.
Numonyx™ Axcell™ M29EW Hardware Protection
208045-11 23
4 Hardware Protection
The M29EW features a VPP/WP# pin that protects the highest or lowest block. Refer to
Section 2: Signal Descriptions for a detailed description of the signal.
5 Software Protection
The M29EW has four different software protection modes:
Volatile Protection
Non-Volatile Protection
Password Protection
Pass word Access
On first use all parts default to operate in non-volatile Protection mode and the customer is
free to activate the non-volatile or the password protection mode.
The desired pr ot ec tion mo de is activated by setting either the one-tim e pr ogramma ble Non-
Volatile Pro tection Mode Lock bit, or the Password Protection Mode Lock bit of the Lock
Register (see Section 7 .1 : Lo ck Register ). Programming the Non-Volatile Protection Mode
Lock bit or the Password Protection Mode Lock bit, to ‘0’ will permanently activate the Non-
volatile or the Password Protection mode, respectively. These two bits are one-time
programmable an d non -volatile: once the protection mod e has been pr ogrammed, it can not
be changed and the device will permanently operate in the selected protection mode. It is
recommended to act ivate the desired soft w are pr otecti on mode when f irst prog r am ming the
device.
The Non-volatile and Password Protection modes both provide non-volatile Protection.
Volatilely protected blocks and non-volatilely protected blocks can co-exist within the
memory arra y. However, the v olatile Prot ection only cont rol the prote ction scheme for bloc ks
that are not protected using the non-volatile or password protection.
If the user attempts to program or erase a protected block, the device ignores the command
and returns to read mode.
The device is shipped with all blocks unprotected. The block protection status can be read
either by performing a read electronic signature (see Table 5 and Table 6) or by issuing an
Auto Select command (see Table 16: Block Protection Status).
For the lowest and highest bl ocks, an even higher level of block protection can be achieved
by loc king the blocks using the non-volatile Protection and then by holding the VPP/WP# pin
Low.
Password Access is a security enhancement offered on the M29EW device. This feature
protects inf ormation stored in th e main-arra y bl ocks b y pre venti ng content alterat ion or reads
until a valid 64-bit password is received. Password Access may be combined with Non-
Volatile and/or Volatile Protection to create a multi-t iered solution.
Please contact your Numonyx Sale s for further details concerning Password Access
feature.
Software Protection Numonyx™ Axcell™ M29EW
24 208045-11
5.1 Volatile Protection mode
The volatile Protection allows the software application to easily prote ct blocks against
inadvertent change. However, the protection can be easily disabled when changes are
needed. Volatile Protection bits, VPBs , are volatile and unique for each block and can be
individually modified. VPBs only control the protection scheme for unprotected blocks that
have their non-v o latile Protection bits , NVPBs, cleared (erased to ‘1’) (see Section 5.2: Non-
Volatile Protection mode and Section 6.3.5: Non-Volatile Protection mode command set).
By issuing the VPB Program or VPB Clear commands, the VPBs are set (programmed to
‘0’) or cleared (er ase d to ‘1’), thus placing associated blocks in the prot ected or u nprotect ed
state respectively. The VPBs can be set (programmed to ‘0’) or cleared (erased to ‘1’) as
often as neede d.
When the parts are first shipped, or after a power-up or hardw are reset, the VPBs default to
be cleared.
Refer to Section 6.3.7 for a description of the volatile Protection mode command set.
5.2 Non-Volatile Protection mode
5.2.1 Non-Volatile Protection bits
A non-volatile Protection bit (NVPB) is assigned to each block.
When a NVPB is set to ‘0’, the associated block is protected, preventing any program or
erase operations in this block.
The NVPB bits can be set individually by issuing a NVPB Program command. They are non-
v olatile and will remain set through a hardware reset or a power-down/power-up sequence.
The NVPBs cannot be cleared in dividually, they can only be all cleared at the same time by
issuing a Clear all Non-Volatile Protection bits command.
The NVPBs can be protected all at a time by setting a volatile bit, the NVPB Lock bit (see
Section 5.2.2: Non-Volatile Protection Bit Lock bit).
If one of the non-volatile protected blocks needs to be unprotected (corresponding NVPB
set to ‘1’), a few more steps are required:
1. First, the NVPB L ock bit m ust be ‘1’ by either putting the device through a power cycle,
or hardware reset.
2. The NVPBs can then be changed to reflect the desired settings.
3. The NVPB Lock bit must be set to ‘0’ once again to lock the NVPBs by associated
command. The device operate s normally again.
Note: 1 To achieve the best prot ection, it is recommended to execute the NVPB Lock Bit Program
command early in the boot code and to protect the boot code by holding VPP/WP# Low, V IL.
2 The NVPBs and VPBs have the same function when VPP/WP# pin is High, VIH, as they do
when VPP /WP# pin is at the voltage f or program acceleration (VPPH).
Refer to Table 16: Block Protection Status and Figure 6: Software protection scheme for
details on the bloc k protect ion mecha nism, and to Section 6.3.5 f o r a d escription of the Non-
Volatile Protection mode command set.
Numonyx™ Axcell™ M29EW Software Protection
208045-11 25
5.2.2 Non-Volatile Protection Bit Lock bit
The Non-Volatile Prot ection Bit Lock bit (NVPB Lock bit) is a global v olatile bit for all NVPBs.
When set (programmed to ‘0’), it prevents changing the state of the NVPBs. When reset to
‘1’, the NVPBs can be set and reset using the NVPB Program command and Clear all
NVPBs command, respectiv ely.
There is only one NVPB Lock bit per device.
Refer to Section 6.3.6 for a description of the NVPB Lock bit command set.
Note: 1 No software command unlocks this bit unless the device is in password prote ction mode; in
standard non-volatile Protection mode, it can be clea red only by taking the de vice thro ugh a
hardware reset or a power-up.
2 The NVPB Lock bit must be set (programmed to ‘0’) only after all NVPBs are configured to
the desired settings.
5.3 Password Protection mode
The password protection mode provides an even higher level of security than the Non-
Volatile Protection mode b y requiring a 64-bit password f or unloc king the de vice NVPB Loc k
bit.
In addition to this password requirement, the NVPB Lock bit is set ‘0’ after power-up and
reset to maintain the device in password protection mode. Successful e xecution of the
Password Unlock command by entering the correct password clears the NVPB Lock bit,
allowing for block NVPBs to be modified.
If the password provid ed is incorre ct, the NVPB Lock bit remains locked and th e state of the
NVPBs cannot be modified.
To place the device in password protection mode, the following steps are required:
1. Prior to ac tivating the password protection mode, it is necessary to set a 64-bit
password and to verify it (see Password Program command and Password Read
command). Passw ord verification is only allowed before the pass word protection mode
is activated.
2. The password protection mode is then activated by programming the Password
Protection Mode Lock bit to ‘0’. This operation is not reversible and once the bit is
programmed it cannot be erased, the device permanently remains in password
protection mod e, and the 64 -b it pa ssword can neither be retrieve d no r re pr ogramme d .
Moreover, all commands to the ad dress where the password is stored, are disabled.
Refer to Table 16: Block Protection Status and Figure 6: Software protection scheme
for details on the b lock protection scheme.
Refer to Section 6.3.4 for a description of the Password Protection mode command set.
Note: There is no means to verify the pass word after P assword Protection mode is enabled. If the
password is lost after enabling the Password Protection mode, there is no way to clear the
NVPB Lock bit.
Software Protection Numonyx™ Axcell™ M29EW
26 208045-11
Figure 6. Software protection scheme
1. NVPBs default to ‘1’ (block unprotected) when shipped from Numonyx. A block is protected or unprotected when its NVPB
is set to ‘0’ and ‘1’, respectively. NVPBs are programmed individually and cleared collectively.
2. VPB default status depends on ordering option. A block is protected or unprotected when its VPB is set to ‘0’ and ‘1’,
respectively. VPBs can be programmed and cleared individually.
3. The NVPB Lock bit is volatile and default to ‘1’ (NVPB bits unlocked) after power-up or hardware reset. NVPB bits are
locked by setting the NVPB Lock bit to ‘0’. Once programmed to ‘0’, the NVPB Lock bit can onl y be reset to ‘1’ by taking the
device through a power-up or hardware reset.
AI13676
A rra y block NVPB(1)
VPB(2)
Non-volatile
protec tion mode
Vola tile prote c tion
N on- v ola tile prote c tion
Pa s sword protec tion
mode
NVPB L ock bit(3)
Numonyx™ Axcell™ M29EW Command Interface
208045-11 27
6 Command Interface
All Bus Write operations to the memory are interpreted by the command interface.
Commands consist of one or more sequential Bus Write operations. Failure to obse rve a
v alid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode.
Note: For 2-Gbit (1-Gbit/1-Gbit) device, all the set-up command should be re-issued to the device
when different die is selected.
6.1 Standard commands
See either Table 9, or Table 10, depending on the configuration that is being used, for a
summary of the standard comman ds.
6.1.1 Read/Reset command
The device enters read mode of main array memory after a reset or pow er-up sequence.
The Read/Reset command returns the memory to Read mode. It also resets the er rors in
the Status Register. Either one or three Bus Write operations can be used to issue the
Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the de vice to Read mode. If the Read/Reset command
is issued during the time-out of a Block erase operation, the memory will take up to 10 µs to
abort. During the abort period no valid data can be read from the mem ory.
The Read/Reset command will not abort an Erase operation when issued while in Erase
Suspend.
6.1.2 Auto Select command
The Auto Select command puts the device in Auto Select mode, once in Auto Select mode,
the system can read the manufacturer code, the device code, the protection status of each
block (Block Protection status) and the Extended Mem ory Block protection indicato r.
Three consecutive Bus Write operations are required to issue the Auto Select command.
Once the A uto Select command is issu ed Bus Read operations to spec ific addresses output
the manufacturer code, the device code, the Extended Memory Block protection indicator
and a b lock protection status (s ee Table 9 and Table 10 in conjun ction with Table 5, Table 6,
Table 7, and Table 8). The memory remains in Auto Select mode until a Read/Reset or CFI
Query command is issued.
Command Interface Numo n yx™ Axcell™ M29EW
28 208045-11
6.1.3 Read CFI Query command
The memory contains an information area, named CFI data structure, which contains a
description of various electrical and timing parameters, density information and functions
supported by the memory. See Appendix B, Table 34, Table 35, Table 36, Table 37 and
Table 38 for details on the information con ta ine d in th e Common Flash Interface (CFI)
memory area.
The Read CFI Query command is used to put the memory in Read CFI Query mode. Once
in Read CFI Query mode, Bus Read operations to the memory will output data from the
Common Flash Interface (CFI) memory area. One Bus Write cycle is required t o issue the
Read CFI Query command. This command is valid only when the device is in the Read
Array or Auto Select mode.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A seco nd Read/Reset command is required to put
the device in Read Array mode from Auto Select mode.
6.1.4 Chip Erase command
The Chip Erase comman d can be used to erase the entire chip. Six Bus Write operations
are required to issue the Chip Erase command and start the Program/Erase controller.
If some b loc k are prote cted, then these ar e ignored and all t he other b loc ks ar e er ased. If all
of the blocks are protected the Chip Erase operation appears to start but will terminate
within about 100 µs, lea ving the data unchanged. No error con dition is giv en when protected
blocks are ignored.
During the Erase operation the memory will ignore all commands, including the Erase
Suspend command. It is not possible t o issue any command to abort the operation. Typical
Chip Erase times are given in Table 28. All Bus Read operations during the Chip Erase
operation will output the Status Register on the Data inputs/outputs. See Section 7.2: Status
Register for more details.
After the Chip Erase operation has completed the memory will return to the Read mode,
unless an error has occurred. When an error occurs the memory will continue to output the
Status Register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
The Chip Erase command sets all of the bits in unprotected blo cks of the memory to ‘1’. All
previous data is lost.
The Chip Erase operation is aborted by performing a reset or powering down the device. In
this case , data integrity cannot be ensured, and it is recommended to erase ag ain the entire
chip.
6.1.5 Block Erase command
The Block Erase command can be used to erase a list of one or more blocks. It sets all of
the bits in the unprotected selected blocks to ‘1’. All previous data in the selected blocks is
lost.
Six Bus Write operations are required to select the first block in the list. Each additional
bl ock in the list can be selected b y repeating the sixth Bus Write oper ation using the ad dress
of the addition al block. After the command sequence is written, a Block Erase time-out
occurs. During the time-out period, additional sector addresses and sector erase commands
may be written. Once the Program/Erase controller has started, it is not possible to select
Numonyx™ Axcell™ M29EW Command Interface
208045-11 29
any more b locks . Each additional blo ck must theref ore be selected within the tim e-out period
of the last block. The time-out timer restarts when an additional block is selected. After the
sixth Bus Write operation, a Bus Read operation outp uts the Status Register . See Figure 21:
Write Enable Controlled Program waveforms (8-bit mode) and Figure 22: Wr ite Enable
Controlled Program waveforms (16-bit mode) for details on how to identify if the
Program/Erase controller has started the Block Erase operation.
After the Block Erase operation has completed, the memory returns to the Read mode,
unless an error has occurred. When an error occurs, Bus Read operations will continue to
output the Status Register. A Read/Reset command must be issued t o reset the error
condition and return to Read mode.
If an y selected b l oc ks are prote cted then t hese are ignored and all the other selected b locks
are erased. If all of the selected bloc ks are protected the Block Erase operation appears to
start but will terminate within about 100 µs, leaving the data unchanged. No error condition
is given when protected blocks are ignored.
During the Block Erase operation the memory ignores all commands except the Erase
Suspend command and the Read/Reset command which is only accepted during the time-
out period. Typical Block Erase time and Block Erase time-out are given in Table 28:
Programming and Erase Performance.
The Bloc k Er ase oper ation is ab orted by performing a reset or po w ering do wn the device. In
this case , data integrity cannot be ensured, and it is recommended to er ase again the bl ocks
aborted.
6.1.6 Blank Check command
The Blank Check operation determines whether a specified block is b lank (i.e. completely
erased). Wit hout Blank Chec k, Bloc k Er ase w ould be the only other w ay to ensure a b loc k is
completely erased. Blank Check can be used to determine whether or not a prior erase
operat ion w as succe ssful; this includ es erase op er ations tha t may hav e been int errupted b y
power-loss. The Blank Check operation checks for cells that are programmed as well as
cells that are over-erased. If any cells are programmed or over-erased, Blank Check will
return a failure status, indicating that the block is not blank. If a Blank Check operation
returns a passing status, the bloc k is guaranteed b lank (all 1's) and ready to program. The
erase algorithm will do Blank Check for the target block firstly. If it's blank (all 1's) then the
actual erase operation will be skipped. Otherwise, the actual erase operation will continue.
This could benefit the overall cycle performance when erase happens on a blank block.
Blank check can occur in only one block at a time, and no operation s ot he r th an Statu s
Register Reads are allowed durin g Blan k Che ck (e.g. reading array data, program, erase
etc). Blank Check is not supported during any suspended operations. The status register
can be examined for Blank Check progress and er rors by reading any address within the
device.
After the Blank Check operation has completed the memory will return to the Read mode,
unless an error has occurred. When an error occurs, Bus Read o perations to the memory
continue to output the Status Register. A Read/Reset command must be issued to reset the
error conditio n an d retu rn to Read mode.
Command Interface Numo n yx™ Axcell™ M29EW
30 208045-11
6.1.7 Erase Suspend command
The Erase Suspe nd command can be used to tempora rily suspend a Block Era se operation.
One Bus Write operat io n is re quir ed to issu e the com mand to gethe r with the block address .
After the command sequence is written, a minimum Block Erase time-out occurs (see
Section 6.1.7: Erase Suspend command). During the time-out period, additional block
addresses and block erase commands can be written.
The Program/Erase controller suspends the erase operation within the Erase Suspend
Latency time of the Erase Suspe nd com m an d be in g issu ed . Howeve r, when the Erase
Suspend command is written during the Block Erase time-out, the device immediately
terminates the time-out period and suspends the erase operation.
Once the Program/Erase controller has stopped, the memory operates in Read mode and
the Erase is suspended.
During Erase Suspend it is possible to read and e xecute Program or Write to Buffer Program
operations in blocks that are not suspended; both read and program operations behave as
normal on these blocks. Reading from blocks that are suspended will output the Status
Register. If any attempt is made to program in a protected block or in the suspended block
then the Program command is ignored and the data remains unch anged. In this case the
Status Register is not read and no error condition is given.
It is also possible to issue the Auto Select, Read CFI Query and Unlock Bypass commands
during an Erase Suspend. The Read/Reset command must b e issued to return the de vice to
Read Array mode before the Resume command will be acce pted.
During Erase Suspend a Bus Read operation to the Extended Memory Block will output the
Extended Memory Block data. Once in the Extended Memory Block mode, the Exit
Extended Memory Block command must be issued before the erase operation can be
resumed.
The Erase Suspend command is ignored if written during Chip Erase operations.
Refer to Table 28: Programming and Erase Performance for the values of Block Erase time-
out and Block Erase Suspend latency time.
If the Erase Suspend operation is aborted by performing a reset or powering down the
device, data integrity cannot be ensured, and it is r ecommended to erase again t he blocks
suspended.
6.1.8 Erase Resume command
The Erase Resume co mmand is used to restart the Program/Er ase controller af ter an Erase
Suspend.
The de vice must be in Read Arra y mode before the Resume command will be accepted. An
erase can be suspended and resumed more than once.
Numonyx™ Axcell™ M29EW Command Interface
208045-11 31
6.1.9 Program Suspend command
The Progr am Suspend command allo ws the system to int errupt a progra m operation so that
data can be read from any block. When the Program Suspend command is issued during a
progr am operation, the device suspends the prog ram opera tion within the Prog ram Suspend
latency time (see Table 28: Programming an d Erase Performance) and updates the Sta tus
Register bits.
After the prog ram operation has been suspend ed, the syste m ca n rea d arra y data f rom any
address. However, data read from program-susp ended addresses is not valid.
The Program Suspend command may also be issued during a program operatio n while an
erase is suspended. In this case, data may be read from any addresse s not in Erase
Suspend or Program Suspend. If a read is needed from the Extended Memory Block area
(one-time program area), the user must use the proper command sequence s to enter and
exit this region.
The system may also issue the Auto Select command sequence when the device is in the
Program Suspend mode. The system can read as many Auto Select codes as required.
When the device exits the Auto Select mode, the device reverts to the Program Suspend
mode, and is ready f or another valid operation. See Auto Select command sequence for
more information.
If the Program Suspend operation is aborted by performing a reset or powering down the
device , data integrity cannot be ensured, and it is recommended to progr am again the words
or bytes aborted.
6.1.10 Program Resume command
After the Program Resume command is issued, the device reverts to programming. The
controller can determine the status of the program operation using the DQ7 or DQ6 status
bits, just as in the standard program operation. Refer to Figure 21: Write Enable Controlled
Program waveforms (8-bit mode) and Figure 22: Write Enable Controlled Program
wavefor m s (1 6- bit mode) for details.
The system must issue a Program Resume command, to exit the Program Suspend mode
and to continue the programming operation.
Further issuing of the Resume command is ignored. Anot her Program Suspend command
can be written after the device has resumed programming.
6.1.11 Program command
The Prog ram command can be used to prog ram a v alue to one address in the memory arra y
at a time. The command requir es f our Bus Write operation s, th e final write operation latches
the address and data in the int ernal state machine and starts the Pr ogram/Erase controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see Section 6.1.9: Program
Suspend command and Section 6.1.10: Progr am Resume command).
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
After programming has started, Bus Read operations output the Status Register conte nt.
See Figure 21: Write Enable Controlled Program waveforms (8-bit mode) and Figure 22:
Command Interface Numo n yx™ Axcell™ M29EW
32 208045-11
Write Enab le Controlled Prog ram wa v ef orms (16 -bit mode) f or mo re details. Typical prog ram
times are given in Table 28: Progr amming and Erase Performance.
After the progr am operation has completed the memory will return to the Read mode , unless
an error has occurr ed. When a n err or occu rs , Bus Read oper atio ns to the me mory continue
to output th e Status Register. A Read/Reset command m ust be issued to reset the error
condition and return to Read mode.
One of the Erase commands must be used to set all the bits in a block or in the whole
memory from ‘0’ to ‘1’.
The Program operation is aborted by performing a reset or powering-down the device. In
this case data integ rity cannot be ensured , and it is recomm ended to repro gr am the w ord or
byte aborted.
Numonyx™ Axcell™ M29EW Command Interface
208045-11 33
Table 9. Standard commands, 8-bit mode
Command
Length
Bus opera t io ns(1)
1st 2nd 3rd 4th 5th 6th
Add Data Add Data Add Data Add Data Add Data Add Data
Read/Reset 1XF0- - - - - - - - - -
3 AAA AA 555 55 X F0 - - - - - -
Auto
Select
Manuf acturer code
3 AAA AA 555 55 AAA 90 (2)(3) (2)(3) ----
Device code
Extended Memory
Bloc k pr otection
indicator
Block protection
status
Program(4) 4AAA AA 555 55 AAA A0 PA PD - - - -
Chip Erase 6 AAA AA 555 55 AAA 80 AAA AA 555 55 AAA 10
Block Erase 6+ AAA AA 555 55 AAA 80 AAA AA 555 55 BAd 30
Erase/Progra m Suspend 1 X B0 - - - - - - - - - -
Erase/Progr am Resume 1 X 30 - - - - - - - - - -
Read CFI Query 1 AA 98 - - - - - - - - - -
Blank Check setup 6 AAA AA 555 55 BAd EB BAd 76 BAd 00 BAd 00
Blank Check confirm and
read 2 BAd 29 BAd (2) --------
1. X = Don’t care, PA = Program Address, PD = Program Data, BAd = Any address in the Block. All values in the table are in
hexadecimal.
2. These cells represent Read cycles. The other cells are Write cycles.
3. The Auto Select addresses and d ata are given in Table 5: Read electronic signature - auto select mode - programmer
method (8-bit mode), and Table 7: Block protection - auto select mode - programmer method (8-bit mode), except for A9
that is ‘Don’t care’.
4. In Unlock Bypass, the first two unlock cycles are no more needed (see Table 11: Fast Program commands, 8-bit mode and
Table 12: Fast Program commands, 16-bit mode).
Command Interface Numo n yx™ Axcell™ M29EW
34 208045-11
Table 10. Standard commands, 16-bit mode
Command
Length
Bus operations(1)
1st 2nd 3rd 4th 5th 6th
Add Data Add Data Add Data Add Data Add Data Add Data
Read/Reset 1XF0-- - - - -- - --
3555AA2AA55 X F0 - - - - - -
Auto
Select
Manufacturer code
3 555 AA 2AA 55 555 90 (2)(3) (2)(3) ----
Device code
Extended Memory
Block protection
indicator
Block protection
status
Program(4) 4555 AA 2AA 55 555 A0 PA PD - - - -
Chip Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10
Block Erase 6+ 555 AA 2AA 55 555 80 555 AA 2AA 55 BAd 30
Erase/Progra m Suspend 1 X B0 - - - - - - - - - -
Erase/Program Resume 1 X 30 - - - - - - - - - -
Read CFI Query 1 55 98 - - - - - - - - - -
Blank Check setup 6 555 AA 2AA 55 BAd EB BAd 76 BAd 00 BAd 00
Blank Check confirm and
read 2 BAd 29 BAd
(2) --------
1. X = Don’t care, PA = Program Address, PD = Program Data, BAd = any address in the Block. All values in the table are in
hexadecimal.
2. These cells represent Read cycles. The other cells are Write cycles.
3. The Auto Select addresses and d ata are given in Table 6: Read electronic signature - auto select mode - programmer
method (16-bit mode), and Table 8: Block protection - auto select mode - programmer method (16-bit mode), except for A9
that is ‘Don’t care’.
4. In Unlock Bypass, the first two unlock cycles are no more needed (see Table 11 and Table 12 Fast Program commands, 8-
bit and 16-bit mode).
Numonyx™ Axcell™ M29EW Command Interface
208045-11 35
6.2 Fast Program commands
The M29EW offers a set of Fast Program commands to improve the programming
throughput:
Write to Buffer Program
Unlock Bypass
See either Table 11: Fast Program commands, 8-bit mode on page 41 or Table 12: Fast
Program commands, 16-bit mode on page 41 depending on the configuration that is being
used, for a summary of the Fast Program commands.
When VPPH is applied to the VPP/Write Protect pin the memory automatically enters Unlock
Bypass mode (see Section 6 .2 .4 : Unlo ck Bypass command ).
After programming has st arted, Bus Read operations in the memory output the Status
Register conte nt . Write to Buffer Program command can be sus pe nded and then resumed
by issuing a Program Suspend command and a Program Resume command, respectively
(see Section 6.1.9: Program Suspend command and Section 6.1.10: Program Resume
command).
After the fast program operation has completed, the memory will return to the Read mode,
unless an error has occurred. When an error occu rs Bus Read operations to the memory
will continue to output the Status Register. A Read/Reset command must be issued to reset
the error condition and return to Read mode. One of the Erase commands must be used to
set all the bits in a block or in the whole memory from ‘0’ to ‘1’.
Typical program times are given in Table 28: Programmin g and Erase Performance.
6.2.1 Write to Buffer Program command
The Write to Buffer Program command makes use of the device’s 512-word program buffer
to speed up programming. A maximum of 512 words can be loaded into the program buffer.
The Write to Buffer Program command dramatically red uc es syste m pr ogramming time
compared to the standard non-buffered Program command.
When issuing a Write to Buffer Prog ram command, the VPP/WP# pin can be either held
High, VIH, or raised to VPPH.
See Table 28 for details on typical Write to Buffer Program times in both cases.
Five successive steps are re qu ir ed to issu e the W rite to Buffer Program command:
1. The Write to Buff er Program command starts with two unlock cycles.
2. The third Bus Write cycle sets up the Write to Buffer Program command. The set-up
code can be addressed to any location within the targeted block.
3. The fourth Bus Write cycle sets up the number of words/bytes to be programmed.
Value N is written to the same block address, where N+1 is the number of words/bytes
to be progr ammed. N+1 must not e xceed the size of t he program b uff er or the operatio n
will abort.
4. The fifth cycle loads the first address and data to be programmed.
5. Use N Bus Write cycles to load the address and data for each word/byte into the
program buffer. Addresses must lie within the range from the start address+1 to the
start address + N-1. Optimum programming performance and lower power usage are
obtained by aligning the starting address at the beginning of a 512-word boundary
(A[8:0] = 0x000h). Any buffer size smaller than 512-word is allowed within 512-word
boundary, while All the addr e sse s use d in th e Write to Buffer Program operation must
Command Interface Numo n yx™ Axcell™ M29EW
36 208045-11
lie within the 512-word boundary. In addition, an y crossing boundary buff er program will
result in a program abort. See Figure 7 for details of the available program buffer size.
To program the content of the program buffer, this command must be followed by a Write to
Buffer Program Confirm command.
If an address is written several times during a Write to Buffer Program operation, the
address/data counter will be decremented at each data load operation and the data will be
programmed to the last word loaded into the buffer.
Invalid address combinations or failing to fo llow the correct sequence of Bus Write cycles
will abort the Write to Buffer Program.
The Status Register bits DQ1, DQ5, DQ6, DQ7 can be used to monitor the device status
during a Write to Buffer Program operation.
It is possible to detect Program operation fails when changing programmed data from ‘0’ to
‘1’, that is when reprogramming data in a portion of memory already programmed. The
resulting data will be the logical OR between the previous value and the current value.
See Figure 8: Write to Buffer Prog r a m fle t ch er and pseu do cod e, for a suggested flow chart
on using the Write to Buffer Program command.
Figure 7. Boundary condition of program buffer size
512 Words
512
Words
program
buffer is
allowed
512
Words
program
buffer is
allowed
Any
buffer
program
attempt
is not
allowed
511
Words
or less
program
buffer is
allowed
0000h
0200h
0400h
512 Words
Numonyx™ Axcell™ M29EW Command Interface
208045-11 37
Figure 8. Write to Buffer Program fletcher and pseudo code
1. n+1 is the number of addresses to be programmed.
2. A Write to Buffer Program Abort and Reset must be issued to return the device in Read mode.
3. When the block address is specified, any address in the selected block address space is acceptable. However when
Write to Buffer
command,
block address
AI08968b
Start
Write Buffer Data,
start address
Abort Write
to Buffer
FAIL OR ABORT
(5)
Write n
(1)
,
block address
X = 0
Write Next Data,
(3)
Program Address Pair
X = X-1
Write to Buffer Program
Confirm, block address
Read Status Register
(DQ1, DQ5, DQ7) at
last loaded address
YES
DQ7 = Data
Check Status Register
(DQ5, DQ7) at
last loaded address
NO
YES
Write to a different
block address
Write to Buffer and
Program Aborted
(2)
DQ5 = 1
DQ1 = 1
DQ7 = Data
(4)
END
First three cycles of the
Write to Buffer and Program command
X=n
YES
YES
YES
YES
NO
NO
NO
NO
NO
Command Interface Numo n yx™ Axcell™ M29EW
38 208045-11
loading program buffer address with data, all addresses must fall within the selected program buffer page.
4. DQ7 must be checked since DQ5 and DQ7 may change simultaneously.
5. If this flow chart location is reached because DQ5=’1’, then the Write to Buffer Program command failed. If this flow chart
location is reached because DQ1=’1’, then the Write to Buffer Program command aborted. In both cases, the appropriate
reset command must be issued to return the device in Read mode: a Reset command if the operation failed, a Write to
Buffer Program Abort and Reset command if the operation aborted.
6. See Table 9 and Table 10, for details on Write to Buffer Program command sequence.
6.2.2 Buffered Program Abort and Reset command
A Buffered Progr a m Abort and Reset command m ust b e issue d to ab ort the Buffe r Prog r am
operation and reset the device in Read mode.
The buf fer programming sequence can be aborted in the following ways:
Load a value that is greater than the page buffer size during the number of
locations to program step in the Write to Buffer Program command.
Write to an address in a block different than the one specified during the write-
buffer-load command.
Write an address/data pair to a different write-buffer-page than the one selected
by the starting address during the program buffer data loading stage of the
operation.
Write data other than the Confirm command after the specified number of data
load cycles.
The abort condition is indicated by DQ1 = 1, DQ7 = DQ7 (for the last address location
loaded), DQ6 = togg le, and DQ5 = 0 (all of which are Status Register bits). A Buffered
Program Abort and Reset command sequence must be written to reset the device for the
next operation. Note that the full 3-cycle Buffered Program Abort and Reset command
sequence is required when using Buffer Programming features in Unlock Bypass mode.
Numonyx™ Axcell™ M29EW Command Interface
208045-11 39
6.2.3 Write to Buffer Program Confirm command
The Write to Buff er Pr ogram Conf irm command is used to confirm a Write to Buff er Prog ram
command and to program the N+1 words/byte s loaded in the program buffer by this
command.
6.2.4 Unlock Bypass command
The Unloc k Bypass command is used to place the de vice in Unloc k Bypass mode. When the
de vice enter s the Unloc k Bypass mode , t he two init ial unloc k cycles required in the stand ard
progr am command sequence are no more ne eded, and only tw o write cycles are required to
program data, instead of the normal four cycles (see Note 4 below Table 9 and Table 10).
This results in a faster total programming time.
Unloc k Bypa ss command is consequently used in conjunction with the Unlock Bypass
Program command to program the memory faster than with the standard program
commands. When the cycle time to the device is long, considerable time saving can be
made by using these commands. Three Bus Write operations are required to issue the
Unlock Bypass command.
When in Unlock Bypass mode, only the Unlock Bypass Program, Unlock Bypass Block
Erase, Unlock Bypass Chip Erase, and Unlock Bypass Reset commands are valid:
The Unlock Bypass Program command can be issued to program addresses
within the mem ory.
The Unlock Bypass Block Erase co mmand can then be issued to erase one or
more memory blocks.
The Unlock Bypass Chip Erase command can be issued to erase the whole
memory array.
The Unlock Bypass Write to Buffer Program command can be issued to speed up
programming operation.
The Unlock Bypass Reset command can be issued to return the memory to Read
mode.
In Unlock Bypass mode the memory can be read as if in Read mode.
6.2.5 Unlock Bypass Program command
The Unloc k Bypass Progr am command can be used to pr ogram on e address in the memory
array at a time. The command requires two Bus Write oper ations, the final write operation
latches the address and data and starts the Program/Erase controller.
The Program operation usin g the Unlock Bypass Program command behaves identically to
the Program operation using the Program command. The operation cannot be aborted, a
Bus Read oper ation to the memory outputs the Stat us Register. See th e prog r am command
in Tab l e 11.: Fast Progr am comma nds , 8-bit mode and Table 12. : Fast Prog ram commands,
16-bit mode for more details.
6.2.6 Unlock Bypass Block Erase command
The Unlock Bypass Block Erase command can be used to Erase one or more memory
blocks at a time. The command requires two Bus Write op erations instead of six using the
standard Block Erase command. The final Bus Write op eration latches the address of the
bl ock and starts the Program/Erase controller.
Command Interface Numo n yx™ Axcell™ M29EW
40 208045-11
To erase multiple block (after the first two Bus Write operations have selected the first block
in the list), each additional block in the list can be selected by repeating the second Bus
Write operation using the address of the additional block.
The Unloc k Bypass Block Erase command behaves in the same way as the Block Erase
command: th e op eration ca nn ot be aborted, and a Bus Read operation to the mem o ry
outputs the Status Register (see Section 6.1.5: Block Erase comma nd for details).
6.2.7 Unlock Bypass Chip Erase command
The Unloc k Bypass Chip Erase comma nd can be used to era se all memory bloc ks at a time .
The command requires two Bus Write operat ions only instead of six using the standard Chip
Erase command. The final Bus Wr ite operation starts the Program/Erase controller.
The Unlock Bypass Chip Erase command behaves in the same way as the Chip Erase
command: th e op eration ca nn ot be aborted, and a Bus Read operation to the mem o ry
outputs the Status Register (see Section 6.1.4: Chip Erase command for details).
6.2.8 Unlock Bypass Write to Buffer Program command
The Unlock Bypass Write to Buffer command can be use d to pro gram the memory in Fast
Program mode. The command requires two Bus Write operations less than the standard
Write to Buffer Program command.
The Unloc k Bypass Write to Buffer Program command behaves in the same way as the
Write t o Buffer Program command: the operation ca nn o t be ab o rte d an d a Bus Read
operation to the memory outputs the Status Register (see Section 6.2.1: Write to Buffer
Program command for details).
The Write to Buffer Program Confirm command is used to confirm an Unlock Bypass Write
to Buffer Program comma nd and to program the N+1 words/ bytes loaded in the program
buffer by this command.
6.2.9 Unlock Bypass Reset command
The Unlock Bypass Reset command can be used to return to Read/Reset mode from
Unlock Bypass mode. Two Bus Write operations are required to issue the Unlock Bypass
Reset command. Read/Reset command does not exit from Unlock Bypass mode.
Numonyx™ Axcell™ M29EW Command Interface
208045-11 41
Table 11. Fast Program comma nds, 8-bit mode
Command
Length
Bus Write operations(1)
1st 2nd 3rd 4th 5th
Add Data Add Data Add Data Add Data Add Data
Write to Buffer
Program N+5 AAA AA 555 55 BAd 25 BAd N(2) PA(3) PD
Write to Buffer
Program Confirm 1 BAd(4) 29 - - - - - - - -
Buff ered Prog ram
Abort and Reset 3 AAA AA 555 55 AAA F0 - - - -
Unlock Bypass 3 AAA AA 555 55 A AA 20 - - - -
Unlock Bypass
Program 2 X A0 PA PD - - - - - -
Unlock Bypass
Block Erase 2+ X 80 BAd 30 - - - - - -
Unlock Bypass
Chip Erase 2X80X10 - - - - - -
Unlock Bypass
Write to Buffer
Program N+3 BAd 25 BAd N(2) PA(3) PD - - - -
Unlock Bypass
Reset 2X90X00 - - - - - -
1. X = Don’t care, PA = Program Address, PD = Program Data, BAd = Any address in the Block. All values in the
table are in hexadecimal.
2. The maximum number of cycles in the buffer program command sequence is 261. The maxi mum number of
cycles in the unlock bypass buffer program command sequence is 259. N+1 is the number of bytes to be
programmed during the Write to Buffer Program operatio n.
3. Amax-A7 address pin should be consistently unchanged. A0-A6 and A-1 pins are used to select a byte within
the N+1 byte page.
4. BAd must be identical to the address loaded during the Write to Buffer Program 3rd and 4th cycles.
Table 12. Fast Program commands, 16-bit mode
Command
Length
Bus Write operations(1)
1st 2nd 3rd 4th 5th
Add Data Add Data Add Data Add Data Add Data
Write to Buffer
Program N+5 555 AA 2AA 55 BAd 25 BAd N(2) PA(3) PD
Write to Buffer
Program Confirm 1 BAd(4) 29------ - -
Buff ered Prog ram
Abort and Reset 3 555 AA 2AA 55 555 F0 - - - -
Unlock Bypass 3 555 AA 2AA 55 555 20 - - - -
Command Interface Numo n yx™ Axcell™ M29EW
42 208045-11
Unlock Bypass
Program 2XA0PAPD- - - - - -
Unlock Bypass Block
Erase 2+ X 80 BAd 30 - - - - - -
Unlock Bypass Chip
Erase 2X80X10- - - - - -
Unlock Bypass Write
to Buffer Program N+3 BAd 25 BAd N(2) PA(3) PD - - - -
Unlock Bypass Reset 2 X 90 X 00 - - - - - -
1. X = Don’t care, PA = Program Address, PD = Program Data , BAd = Any address in the Block. All values in the
table are in hexadecimal.
2. The maximum number of cycles in the buffer program command sequence is 517. The maxi mum number of
cycles in the unlock bypass buffer program command sequence is 515. N+1 is the number of bytes to be
programmed during the Write to Buffer Program operatio n.
3. Amax-A9 address pins should be consistently unchanged. A0-A8 pins are used to select a word within the
N+1 word page.
4. BAd must be identical to the address loaded during the Write to Buffer Program 3rd and 4th cycles.
Table 12. Fast Program commands, 16-bit mode
Command
Length
Bus Write operations(1)
1st 2nd 3rd 4th 5th
Add Data Add Data Add Data Add Data Add Data
Numonyx™ Axcell™ M29EW Command Interface
208045-11 43
6.3 Protection commands
Blocks can be protected individually against accidental program, erase or read operations.
The device b lock protection scheme is sho wn in Figure 6: Software protection scheme. See
either Table 13, or Table 14, depending on the configura tion that is being used, for a
summary of the Block Protection commands.
Block protection commands are available both in 8-bit and 16-bit configuration.
The protections of both memory bloc ks and Extended Memory Block protection are
configured thr ough the Lock register (see Section 7.1: Lock Register ).
6.3.1 Enter Extended Memory Block command
The M29EW has one extra 128-word Extended Memory Block that can only be accessed
using the Enter Extended Memory Block command.
Three Bus Write cycles are required to issue the Enter Extended Memory Block command.
Once the command has been issued the device enters the Extended Memory Block mo de
where all Bus Read or Program operations are conducted on the Extended Memory Block.
Once the device is in the Ext ended Memory Block mode, the Extended Memory Block is
addressed by using the addresses occup ied by bloc k 0 in the other operat ing modes (see
Figure 5: Block addresses on page 12).
The de vice remain s in Extended Memory Block mode until the Exit Extended Memory Block
command is issued or power is removed from the device. After a power-up sequence or
hardware reset, the device will revert to reading from memory blocks in the main array.
The Extended Memory Bloc k cannot be erased, and each bit of t he Extended Memory Block
can only be programmed once.
In Extended Memory Block mode, Erase, Chip Erase, Erase Suspend and Erase Resume
commands ar e no t allowed.
To exit from the Extended Memory Block mode the Exit Extended Memory Block command
must be issued.
The Extended Memory Block is protected from further modificati on by programming Lock
Register bit 0 (see Section 7.1: Lock Register). Once invoked, this protection cannot be
undone.
6.3.2 Exit Extended Memory Block command
The Exit Extended Memory Block comma nd is used to exit from the Extended Memory
Bloc k mode a nd return the device to Read mode. Four Bus Write oper ations ar e requ ired to
issue the command.
Command Interface Numo n yx™ Axcell™ M29EW
44 208045-11
6.3.3 Lock Register command set
The M29EW offers a set of commands to access the Lock Register and to configure and
verify its content. See the following sections in conjunction with Section 7.1: Lock Register,
Table 13 and Table 14.
Enter Lock Register Command Set command
Three Bus Write cycles are required to issue the Ente r Lock Register Command Set
command. Once the command has been issued, all Bus Read or Program operations are
issued to the Lock Register.
Lock Register Program and Lock Register Read command
The Lock Register Program command allows to configure the Lock Register. The
programmed data can then be checked by issuing a Lock Register Read command.
An Exit Protection Command Set command must then be issued to return the device to
Read mode (see Section 6.3.8: Exit Protection command set).
6.3.4 Password Protection mode command set
Enter Password Protection Command Set command
Three Bus Write cycles are required to issue the Enter Password Protection Command Set
command. Once the command has been issued, the commands related to the Password
Protection mode can be issued to the device.
Password Program command
The Password Program command is used to program the 64-bit password used in the
Password Protection mode.
To program the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15/A-1 in 8-bit mode, or
four times at four consecutive addresses selected by A1-A0 in 16-bit mode.
The password can be checked by issuing a Password Read command.
Once Password Program operation has completed, an Exit Protection Command Set
command must be issued to return the device to Read mode. The Password Protection
mode can then be selected.
By default, all Password bits are set to ‘1’.
Note: In order to use password protection feature on 2-Gbit (1-Gbit/1-Gbit stack) de vice, the
password must be programmed to both upper die and bottom die respectively.
Password Read command
The Password Read command is used to verify the Password used in Password Protection
mode.
To verify the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15/A-1 in 8-bit mode, or
four times at four consecutive addresses selected by A1-A0 in 16-bit mode.
If the Password Mode Lock bit is programmed and the user atte mp ts to rea d the pa ssword,
the device will output FFh onto the I/O data bus.
Numonyx™ Axcell™ M29EW Command Interface
208045-11 45
An Exit Protection Command Set command must be issued to return the device to Read
mode.
Password Unlock command
The Password Unlock command is used to clear the NVPB Lock bit allowing to modify the
NVPBs.
The Password Unlock command must be issued along with the correct password.
There must b e a 1 µs delay between successive Password Unlock commands in order to
pre v ent hac kers from crac king the pass w ord by t rying all possib le 64-bit comb inations. If this
delay is not respected, the latest command will be ignored.
Approximately 1 µs is required for unlocking the device after the valid 64-bit password has
been provided.
6.3.5 Non-Volatile Protection mode command set
Enter Non-Volatile Protection Command Set command
Three Bus Write cycles are required to issue the Enter Non-Volatile Protect ion Command
Set command. Once the command has been issued, the commands related to the Non-
Volatile Protection mode can be issued to the device.
Non-Volatile Protection Bit Program command (NVPB Program)
A block can be protected from program or erase by issuing a Non-Volatile Protection Bit
command along with the block address. This command sets the NVPB to ‘1’ for a given
block.
Read Non-Volatile Protection Bit Status command (Read NVPB Status)
The status of a NVPB for a given block or group of blocks can be read by issuing a Read
Non-Volatile Modify Protection Bit command along with the block address.
Clear all Non-Volatile Protection Bits command (Clear all NVPBs)
The NVPBs are erased simultaneously by issuin g a Clear all Non-Volatile Protection Bits
command. No specific block address is required. If the NVPB Lock bit is set to ‘0’, the
command fails.
Command Interface Numo n yx™ Axcell™ M29EW
46 208045-11
Figure 9. NVPB Program/Erase algorithm
AI14242
YES
DQ6=
Toggle NO
YES
NO
Ent er NVPB
c omma nd s e t.
Program NVPB
A ddr = BA d
Re ad By te twi ce
A ddr = BA d
DQ5=1
Re ad By te twi ce
A ddr = BA d
NO
YES W ait 500 μs
DQ6=
Toggle Read By te twi c e
A ddr = BA d
Fail
Reset Pass
DQ0=
'1'(Erase)
'0'(Program)
NO
Exit NVPB
c omma nd s e t
YES
Numonyx™ Axcell™ M29EW Command Interface
208045-11 47
6.3.6 NVPB Lock Bit command set
Enter NVPB Lock Bit Command Set command
Three bus Write cycles are required to issue the Enter NVPB Lock Bit Command Set
command. Once the command has been issued, the commands allowing to set the NVPB
Lock bit can be issued to the device .
NVPB Lock Bit Program command
This command is used to set the NVPB Lock bit to ‘0’ thus locking the NVPBs , and
preventing them from be in g mo d ified .
Read NVPB Lock Bit Status command
This command is used to read the status of the NVPB Lock bit.
6.3.7 Volatile Protection mode command set
Enter Volatile Protection Command Set command
Three bus Write cycles are required to issue the Enter Volatile Protection Command Set
command. Once the command has been issued, the commands related to the Volatile
Protection mode can be issued to the device.
Volatile Protection Bit Program command (VPB Program)
The VPB Program command individually sets a VPB to ‘0’ for a giv en bloc k.
If the NVPB f or the same block is set, the block is locked regardless of the v alue of the VPB
bit. (see Table 16: Block Protection Status).
Read VPB Status command
The status of a VPB for a given block can be read by issuing a Read VPB Status command
along with the bloc k address.
VPB Clear command
The VPB Clear command individually clears (sets to ‘1’) the VPB for a given block.
If the NVPB f or the same block is set, the block is locked regardless of the value of the VPB
bit. (see Table 16: Block Protection Status).
6.3.8 Exit Protection command set
The Exit Protection Command Set command is used to exit from the Lock Register,
Password Protection, Non-Volatile Protection, Volatile Protection, and NVPB Lock Bit
Command Set mode. It return the device to Read mode.
Command Interface Numo n yx™ Axcell™ M29EW
48 208045-11
Table 13. Block Protection commands, 8-bit mode(1)(2)(3)
Command
Length
Bus operations
1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th 11th
Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data
Lock Register
Enter Lock
Register
Command
Set(4) 3AAAAA55555AAA40------------- ---
Lock Reg ister
Program 2X A0 XDATA
(5) - -----------------
Lock Reg ister
Read 1 X DATA
(5) - - - ------------- ----
Password Protection
Enter
Password
Protection
Command
Set(4)
3AAAAA55555AAA60------------- ---
Password
Program (6)(7) 2X A0PWA
nPWD
n- -------------- ---
Password
Read 800 PWD
001 PWD
102 PW
D2 03 PW
D3 04 PW
D4 05 PW
D5 06 PW
D6 07 PW
D7 - - - - - -
Password
Unlock(7) 1
100 25 00 03 00 PW
D0 01 PW
D1 02 PW
D2 03 PW
D3 04 PW
D4 05 PW
D5 06 PW
D6 07 PW
D7 00 29
Non-Volatile Protection
Enter Non-
Volatile
Protection
Command
Set(4)
3AAAAA55555AAAC0----------------
NVPB
Program(8) 2XA0BAd00- -----------------
Clear all
NVPBs(9) 2X800030- -------------- ---
Read NVPB
Status (8) 1BAd RD(0)- - - -----------------
NVPB Lock bit
Enter NVPB
Lock Bit
Command
Set
3AAAAA55555AAA50------------- ---
NVPB Lock
Bit Program(8) 2XA0X00- -----------------
Read NVPB
Lock Bit
Status (8) 1 X RD(0)- - - -----------------
Volatile Protection
Enter Volatile
Protection
Command
Set
3AAAAA55555AAAE0----------------
VPB
Program(8) 2XA0BAd00- -----------------
Read VPB
Status 1BAd RD(0)- - - -----------------
VPB Clear(8) 2XA0BAd01- -----------------
Exit Prot ection
Command Set
(10) 2X90X00- -----------------
Enter Extended
Memory Block(4) 3AAAAA55555AAA88----------------
Exit Exte nded
Memory B lock 4AAAAA55555AAA90X00--------------
Numonyx™ Axcell™ M29EW Command Interface
208045-11 49
1. Ad = address; Dat = data; BAd = Any address in the Block; RD = Read data; PWDn = Password byte 0 to 7; PWAn =
Password Address (n = 0 to 7); X = Don’t care. All values in the table are in hexadecimal.
2. Grey cells represent Read cycles. The other cells are Write cycles.
3. DQ15 to DQ8 are ‘Don’t care’ during unlock and command cycles. Amax to A16 are ‘Don’t care’ during unlock and
command cycles unless an address is required.
4. An Enter command sequence must be issued prior to any operation. It disables read and write operations from and to block
0. Read and write operations from any othe r block are allowed.
5. DATA = Lock Register content.
6. Only one portion of password can be programmed or read by each Password Program command.
7. The password portion can be entered or read in any order as long as the entire 64-bit password is entered or read.
8. Protected and unprotected states correspond to 00 and 01, respectively.
9. The Clear all NVPBs command programs all NVPBs before erasure in order to prevent the over-erasure of previously
cleared Non Volatile Modify Protection bits.
10. If an Entry Command Set command is issued, an Exit Protection Command Set command must be issued to return the
device to Read mode.
Command Interface Numo n yx™ Axcell™ M29EW
50 208045-11
Table 14. Block Protection commands, 16-bit mode(1)(2)(3)
Command
Length
Bus operations
1st 2nd 3rd 4th 5th 6th 7th
Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data Ad Data
Lock register
Enter Lock
Register
Command
Set(4) 3 555 AA 2AA 55 555 40 - - - - - - - -
Lock Register
Program 2X A0 XDATA
(5) - - --------
Lock Register
Read 1XDATA
(5) ------------
Password Pro tecti on
Enter
Password
Protection
Command
Set(4)
3 555 AA 2AA 55 555 60 - - - - - - - -
Password
Program (6)(7) 2 X A0 PWAn PWDn - - - - - - - - - -
Password
Read 400 PWD0 01 PWD1 02 PWD2 03 PWD3------
Password
Unlock(7) 7 00 25 00 03 00 PWD0 01 PWD1 02 PWD2 03 PWD3 00 29
Non-Volatile Protection
Enter Non-
Volatile
Protection
Command
Set(4)
3 555 AA 2AA 55 555 C0 - - - - - - - -
NVPB
Program(8) 2 X A0 BAd 00 - - - - - - - - - -
Clear all
NVPBs(9) 2 X 80 00 30 - - - - - - - - - -
Read NVPB
Status 1BAd RD(0) - - - - - - - - - - - -
NVPB Lock bit
Enter NVPB
Lock Bit
Command Set 3 555 AA 2AA 55 555 50 - - - - - - - -
NVPB Lock Bit
Program 2XA0 X 00 - - --------
Read NVPB
Lock Bit Sta tus 1XRD(0) - - - - - - - - - - - -
Volatile Protection
Enter Volatile
Protection
Command Set 3 555 AA 2AA 55 555 E0 - - - - - - - -
VPB Program 2 X A0 BAd 00 - - - - - - - - - -
Read VPB
Status 1BAd RD(0) - - - - - - - - - - - -
VPB Clear 2 X A0 BAd 01 - - - - - - - - - -
Exit Protection
Command Set(10) 2X90 X 00 - - - -------
Enter Extended
Memory Block(4) 3 555 AA 2AA 55 555 88 - - - - - - - -
Exit Extended
Memory Block 4 555 AA 2AA 55 555 90 X 00 - - - - - -
Numonyx™ Axcell™ M29EW Command Interface
208045-11 51
1. Ad = address; Dat = data; BAd = Any address in the Block; RD = Read data; PWDn = Password byte 0 to 3; PWAn =
Password Address (n = 0 to 3); X = Don’t care. All values in the table are in hexadecimal.
2. Grey cells represent Read cycles. The other cells are Write cycles.
3. DQ15 to DQ8 are ‘Don’t care’ during unlock and command cycles. Amax to A16 are ‘Don’t care’ during unlock and
command cycles unless an address is required.
4. An Enter command sequence must be issued prior to any operation. It disables read and write operations from and to block
0. Read and write operations from any othe r block are allowed.
5. DATA = Lock Register content.
6. Only one portion of password can be programmed or read by each Password Program command.
7. The password portion can be entered or read in any order as long as the entire 64-bit password is entered or read.
8. Protected and unprotected states correspond to 00 and 01, respectively.
9. The Clear all NVPBs command programs all NVPBs before erasure in order to prevent the over-erasure of previously
cleared Non-volatile Modify Protection bits.
10. If an Entry Command Set command is issued, an Exit Protection Command Set command must be issued to return the
device to Read mode.
Registers Numonyx™ Axcell™ M29EW
52 208045-11
7 Registers
The device feature two registers:
1. A Loc k Register that allows to configure the memory blocks and Extended Memory
Block pr otection (see Table 16: Block Protection Status)
2. A Status Register that provides information on the current or previous Program or
Erase operations.
7.1 Lock Register
The Loc k Regi ster is a 16-bit one- time prog r a mmable register. The bits in th e Lock Register
are summarized in Table 15: Lock Register bits.
See Section 6.3.3: Lock Register command set for a description of the commands allowing
to read and program the Lock Regi ster.
7.1.1 Password Protection Mode Loc k bit (DQ2)
The Passwor d Protection Mode Lock bit, DQ0, is one-time programmable. Progr amming
(setting to ‘0’) this bit permanently places the device in Password Protection mode.
Any attempt to program the Password Protection mode Lock bit when the Non-Volatile
Protection Mode bit is prog rammed causes the oper ation to ab ort and th e de vice to return to
Read mode.
7.1.2 Non-Volatile Protection Mode Lock bit (DQ1)
The Non-Volatile Protection Mode Lock bit, DQ1, is one-time prog rammable. Programming
(setting to ‘0’) this bit permanently places the device in Non-Volatile Protection mode.
When shipped from Numonyx factory, all parts default to operate in Non-Volatile Protection
mode. The memory blocks are unprotected (NVPBs set to ‘1’).
Any attempt to program the Non-Volatile Protection mode Lock bit when the Password
Protection Mode bit is prog rammed causes the oper ation to ab ort and th e de vice to return to
Read mode.
7.1.3 Extended Memory Block Protection bit (DQ0)
If the device is shipped with the Extended Memory Block unlocked, the block can be
protected b y setting the Extend ed Memory Bloc k Protection bit, DQ0, to ‘0’. Howe v er , this bit
is one-time programmable and once protected the Extended Memory Block cannot be
unprotected any more.
The Extended Memory Block protection status can be read in Auto Select mode by issuing
an Auto Select command (see Table 9 and Table 10).
Numonyx™ Axcell™ M29EW Registers
208045-11 53
Table 15. Lock Register bits(1)
DQ15-3(2) DQ2 DQ1 DQ0
Reserved Pa ssword Protection Mode Lock
bit Non-Volatile Protection Mode
Lock bit Extended Memory
Block Protection bit
1. DQ0, DQ1 and DQ2 Lock Register bits are set to ‘1’ when shipped from the Numonyx.
2. DQ15 to DQ3 are reserved and default to ‘1’.
Table 16. Block Protection Status
NVPB Lock bit(1) Block
NVPB(2) Block
VPB(3)
Block
protection
status Block Protection Status
1 1 1 00h Block unprotected (NVPB changeable)
1 1 0 01h Block protected by VPB (NVPB changeable)
1 0 1 01h Block protected by NVPB (NVPB changeable)
10001h
Block protected by NVPB and VPB (NVPB
changeable)
0 1 1 00h Block unprotected (NVPB unchangeable)
0 1 0 01h Bloc k protected b y VPB (NVPB unchangeable)
00101h
Block protected by NVPB (NVPB
unchangeable)
00001h
Block protected by NVPB and VPB (NVPB
unchangeable)
1. If the NVPB Lock bit is set to ‘0’, all NVPBs are locked. If the NVPB Lock bit is set to ‘1’, all NVPBs are unlocked.
2. If the Block NVPB is set to ‘0’, the block is protected, if set to ‘1’, it is unprotected.
3. If the Block VPB is set to ‘0’, the block is protected, if set to ‘1’, it is unprotected.
Registers Numonyx™ Axcell™ M29EW
54 208045-11
Figure 10. L ock Register program flowchart
1. PD is the programmed data (see Table 15: Lock Register bits).
2. Each bit of the Lock Register can only be programmed once.
START
PASS:
Write Lock Register Exit command:
Add Dont' care, Data 90h
Add Dont' care, Data 00h
ai13677
Done
YES
YES
NO
DQ5 = 1 NO
Write Unlock cycles:
Add 555h, Data AAh
Add 2AAh, Data 55h Unlock cycle 1
unlock cycle 2
Write
Enter Lock Register command set:
Add 555h, Data 40h
Program Lock Register Data:
Add Dont' care, Data A0h
Add Dont' care(1), Data PDh
Polling algorithm
Device returned
to Read mode FAIL
Reset to return
the device to Read mode
Numonyx™ Axcell™ M29EW Registers
208045-11 55
7.2 Status Register
The M29EW discrete device has one Status Register. The various bits convey information
and errors on the cur rent and previous progr am/ erase oper ati on. Bus Read ope r atio ns from
any addre ss within the memory, alw ays read th e Status Register du ring Program and Erase
operations. It is also read du ring Erase Suspend when an address within a block being
erased is accessed.
The bits in the Status Register are summarized in Table 17: Status Register bits.
7.2.1 Data Polling bit (DQ7)
The Data Polling bit can be used to identify whether the Program/Erase controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Data
Polling bit is output on DQ7 when the Status Register is read.
During Program operations the Data Polling bit outputs the complement of the bit being
programmed to DQ7. After successful completion of the Program operat ion the memory
returns to Read mode and Bus Read oper ations , from the ad dress just progr ammed , output
DQ7, not its complement.
During Erase or Blank Check operations the Data Polling bit outputs ‘0’, the complement of
the erased state of DQ7. When the algorithm is complete, Data Polling produces a '1' on
DQ7. After successful completion of the Erase or Blank Check operation the memory
returns to Read mode.
In Erase Suspend mode the Data Polling bit will output a ‘1’ during a Bus Read operation
within a block being erased. The Data Polling bit will change from ‘0’ to ‘1’ when the
Program/Erase controller has suspended the Erase operation.
Figure 11: Data polling flow chart, gives an example of how to use the Data Polling bit. A
Valid Address is the addre ss being programmed or an address within the b lock being era sed
or blank checked.
7.2.2 Toggle bit (DQ6)
The Toggle bit can be used to ident ify whether the Progr am/Erase controller has
successfully completed its operation or if it has responded to an Er ase Suspend. The Toggle
bit is output on DQ6 when the Status Register is read.
During a Program/Erase operat ion the Toggle bit changes from ‘0’ to ‘1’ to ‘0’, etc., with
successive Bus Read operations at any address . After successful completion of the
operation the memory returns to Read mode.
During Erase Suspend mode the Toggle bit will output when addressing a cell within a bloc k
being erased. The Toggle bit will stop toggling when the Program/Erase controller has
suspended the Erase operation.
Figure 12: Toggle flow chart, gives an example of how to use the Data Toggle bit.
7.2.3 Error bit (DQ5)
The Error bit can be used to ident ify errors detected by the Program/Erase con troller. The
Error bit is set to ‘1’ when a Program, Block Erase or Chip Erase operation fails to write the
correct data to the memory, or a Blank Check operation fails. If the Error bit is set a
Registers Numonyx™ Axcell™ M29EW
56 208045-11
Read/Reset command must be issued before other commands are issued. The Error bit is
output on DQ5 when the Status Register is read.
Note that the Prog ram command cannot change a bit set t o ‘0 ’ back to ‘1’ and attemptin g to
do so will set DQ5 to ‘1’. A Bus Read operation to that address will show the bit is still ‘0’.
One of the Erase commands must be used to set all the bits in a block or in the whole
memory from ‘0’ to ‘1’.
7.2.4 Erase Timer bit (DQ3)
The Erase Timer bit can be used to identify the start of Program/Era se controller operation
during a Block Er ase command. Once the Pro gram/Erase controller starts erasing the Erase
Timer bit is set to ‘1’. Before the Program/Er ase controlle r starts the Er ase Timer bit is set to
‘0’ and additional blocks to be erased may be written to the command interface. The Erase
Timer bit is output on DQ 3 when the Status Register is read.
7.2.5 Alternative Toggle bit (DQ2)
The Alternative Togg le bit can be used to monitor the Program/Er ase controller during Erase
operations. The Alternative Toggle bit is output on DQ2 when the Status Register is read.
During Chip Erase and Block Erase operations the Toggle bit changes from ‘0’ to ‘1’ to ‘0’,
etc., with successiv e Bus Read operations from ad dresses within the b locks being er ased. A
protected block is treated the same as a block not being erased. Once the operation
completes the memory returns to Read mode.
During Erase Suspend the Alternative Toggle bit changes from ‘0’ to ‘1’ to ‘0’, etc. with
successive Bus Read ope r at ion s f rom addre sses within the bloc ks bei ng erased. Bus Read
operat ions to addresses within bloc ks not being er ased will output the mem ory arra y data as
if in Read mode.
7.2.6 Buffered Program Abort bit (DQ1)
The Buffered Program Abort bit, DQ1, is set to ‘1’ when a Buffer Program operation aborts.
The Buffered Program Abort and Reset command must be issued to return the device to
Read mode (see Write to Buffer Program in Section 6.1: Standard commands).
For the complete polling flow chart, please refer to Figure 13.: Status Register Polling Flow
Chart.
Numonyx™ Axcell™ M29EW Registers
208045-11 57
Table 17. Status Register bits(1)
Operation Address DQ7 DQ6 DQ5 DQ3 DQ2 DQ1 RY/BY#
Program(2) Any address DQ7 Toggle 0 No
Toggle 00
Program During Erase Suspend Any address DQ7 Toggle 0 0
Buff ered Prog ram Abort(2) Any address DQ7 Toggle 0 1 0
Program Error Any address DQ7 Toggle 1 Hi-Z
Chip Erase Any address 0 Toggle 0 1 Toggle 0
Block Erase before timeout Erasing block 0 Toggle 0 0 Toggle 0
Non-erasing
block 0 Toggle 0 0 No
toggle –0
Block Erase/Blank Check
Erasing/Verifying
block 0 Toggle 0 1 Toggle 0
Non-
erasing/Verifying
block 0 Toggle 0 1 No
toggle –0
Erase/Blank Check Suspend
Erasing/Verifying
block 1 No Toggle 0 Toggle Hi-Z
Non-
erasing/Verifying
block Data read as normal Hi-Z
Erase/Blank Check Error Any address 0 Toggle 1 1 Toggle Hi-Z
1. Unspecified data bits should be ignored.
2. DQ7 for Buffer Program is related to the last address location loaded.
Registers Numonyx™ Axcell™ M29EW
58 208045-11
Figure 11. Data polling flow c hart
RE AD DQ 5 & DQ7
at V ALID ADDRESS
START
READ DQ7
at V ALID ADDRESS
FAIL PASS
AI07760
DQ7
=
DATA YES
NO
YES
NO
DQ5 = 1
DQ7
=
DATA YES
NO
DQ = 1
YES
NO
Numonyx™ Axcell™ M29EW Registers
208045-11 59
Figure 12. Toggle flow chart
READ DQ6 at
Valid Address
START
READ DQ6
TWICE
at Valid Address
FAIL PASS
AI11530
DQ6
=
TOGGLE NO
NO
YES
YES
DQ5
= 1
NO
YES
DQ6
=
TOGGLE
READ
DQ5 & DQ6
at Valid Address
Registers Numonyx™ Axcell™ M29EW
60 208045-11
Figure 13. Status Register Polling Flow Chart
Read 1
Read 2
Start
DQ7=Valid
Data?
DQ5=1?
Timeout failure
Device Busy, Re-
Poll
DQ6
toggling?
DQ1=1? Writ e Buffer
Program Abort
Device Busy, Re-
Poll
Read 3 Programming
Operation? Read3 correct
data?
Programming
Operation
Complete
Programming
Operation Failed
DQ6
toggling? DEVI CE ERROR
DQ2
toggling?
Read1.DQ6
Read2.DQ6
Read2.DQ6
Read3.DQ6
Read2.DQ2
Read3.DQ2
No
Yes Yes Yes
No
Yes
No
No
Yes
Yes
No
No
Yes
No
Device in Erase/
Suspend Mode
Erase Complete
Yes
No
Invalid state use
RESET comand
Read 2
Read 3
Write Buffer
Programming Yes
No
Numonyx™ Axcell™ M29EW Maximum Ratings
208045-11 61
8 Maximum Ratings
Stressing the device above the rating listed in Table 18: Absolute maximum ratings may
cause permanent damage to the device. Exposure t o absolute maximum rating conditions
for extended periods may affect device reliability. These are stress ratings only and
operation of the device at these or any other conditions above those indicated in the
operating sections of this specification is not implied. Refer also to the rele vant quality
documents from Numonyx.
Table 18. Absolute maximum ratings
Symbol Parameter Min Max Unit
TBIAS Temperature under bias 50 125 °C
TSTG Storage temperature 65 150 °C
VIO Input or output voltage(1)(2) 0.6 VCC +0.6 V
VCC Supply voltage 0.6 4 V
VCCQ Input/output supply voltage 0.6 4 V
VPPH(3) Program voltage 0.6 14.5 V
1. Minimum voltage may undershoot to 2 V during transition and for less than 20ns during transitions.
2. Maximum voltage may overshoot to VCC + 2 V during transition and for less than 20ns during transitions.
3. VPPH must not remain at 12 V for more than a total of 80hrs.
DC and AC Parameters Numonyx™ Axcell™ M29EW
62 208045-11
9 DC and AC Parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 19: Operating and AC measurement conditions. Designers sho u l d che ck that the
operat ing conditions in their circuit match the operating conditions when relyin g on the
quoted parameters.
Figure 14. AC measurement load circuit
Figure 15. AC measurement I/O waveform
Table 19. Operating and AC measurement conditions
Parameter Min Max Unit
VCC supply voltage 2.7 3.6 V
VCCQ supply voltage (VCCQ VCC)1.653.6V
VPP supply voltage -2.0 12.5 V
Ambient operating temp erature 40 85 °C
Load capacitance (CL)30pF
Input rise and fall times 10 ns
Input pulse voltages 0 to VCCQ V
Input and output timing ref. voltages VCCQ/2 V
AI05558b
CL
CL includes JIG capacitance
DEVICE
UNDER
TEST
25 kΩ
VCCQ
25 kΩ
VCC
0.1 µF
VPP
0.1 µF
AI05557b
VCCQ
0 V
VCCQ/2
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 63
Figure 16. Power-up wait timings
Table 20. Power-up wait timings
Symbol Alt. Parameter Min Unit
tVCHVCQH -V
CC(1) High to VCCQ(1) High 0 µs
tVCHPH(2) tVCS VCC High to rising edge of RST# 300 µs
tVCQHPH(2) tVIOS VCCQ High to rising edge of RST# 0 µs
tPHEL tRH RST# High to Chip Enable Low 50 ns
tPHWL - RST# High to Write Enable Low 150 ns
1. VCC and VCCQ ramps must be synchronized during power-up.
2. If RST# is not stable for tVCHRH or tVCQHRH, the device does not permit any Read and Write operations and a hardware
reset is required.
AI14247
V
CC
RST#
t
VCHPH
t
PHEL
CE#
V
CCQ
t
VCQHPH
WE#
t
VCHVCQH
t
PHWL
DC and AC Parameters Numonyx™ Axcell™ M29EW
64 208045-11
Table 21. Device capacitance(1)
Symbol Parameter Test condition Min Max Unit
CIN
Input capacitance for 256-Mbit and 512-Mbit
VIN = 0 V
38
pF
Input capacitance for 1-Gbit 4 9
Input capacitance for 2-Gbit (1-Gbit/1-Gbit) 8 18
COUT Output capacitance VOUT = 0 V 3 6
1. Sampled only, not 100% tested.
Table 22. DC characteristics
Symbol Parameter Test condition Min Typ Max Unit
ILI(1) Input leakage current 0 V VIN VCC --±1µA
ILO Output leakage current 0 V VOUT VCC --±1µA
ICC1 Read current Random Read CE# = VIL, OE# = VIH,
f=5MHz -2631mA
Page Read CE# = VIL, OE# = VIH,
f=13MHz -1216mA
ICC2 Supply current
(Standby)
256-Mbit
CE# = VCCQ ±0.2V,
RST# = VCCQ ±0.2V
- 65 210
µA
512-Mbit - 70 225
1-Gbit - 75 240
2-Gbit - 150 480
ICC3(2) Supply current
(Program/Erase/Blank Check) Program/Erase
controller active
VPP/WP# =
VIL or VIH -3550mA
VPP/WP#=VPPH -3550mA
IPP1
VPP current
Read VPP/WP# VCC -0.25µA
Standby VPP/WP# VCC -215µA
IPP2 Reset RST# = VSS ±0.2V -0.25µA
IPP3
Program
operation
ongoing
VPP/WP# = 12 V ± 5% - 0.05 0.10 mA
VPP/WP# = VCC - 0.05 0.10 mA
IPP4
Erase
operation
ongoing
VPP/WP# = 12 V ± 5% - 0.05 0.10 mA
VPP/WP# = VCC - 0.05 0.10 mA
VIL Input Low voltage VCC 2.7 V 0.5 - 0.8 V
VIH Input High voltage VCC 2.7 V 0.7VCCQ -V
CCQ+0.4 V
VOL Output Low voltage IOL = 100 µA, VCC =V
CC(min),
VCCQ =V
CCQ(min) - - 0.15VCCQ V
VOH Output High voltage IOH = 100 µA, VCC =V
CC(min),
VCCQ =V
CCQ(min) 0.85VCCQ --V
VPPLK VPP Lock-Out voltage - - - 0.4 V
VPPH Voltage for VPP/WP# Program
acceleration - 11.5 - 12.5 V
VLKO(2) Program/Er ase lockout supply
voltage -2.3--V
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 65
Figure 17. Random Read AC wave forms (8-bit mode)
Figure 18. Random Read AC wavef orms (16-bit mode)
1. The maximum input leakage current is ±5 µA on the VPP/WP# pin.
2. Sampled only, not 100% tested.
AI13698
tAVAV
tAVQV tAXQX
tELQX tEHQZ
tGLQV
tGLQX tGHQX
VALID
A0-AMAX/A-1
OE#
DQ0-DQ15
CE#
tELQV tEHQX
tGHQZ
VALID
tELBL tBLQZ
BYTE#
AI08970
tAVAV
tAVQV tAXQX
tELQX tEHQZ
tGLQV
tGLQX tGHQX
VALID
A0-AMAX
OE#
DQ0-DQ7
CE#
tELQV tEHQX
tGHQZ
VALID
tELBH
BYTE#
DC and AC Parameters Numonyx™ Axcell™ M29EW
66 208045-11
Figure 19. BYTE# Transition AC Waveform
Figure 20. Page Read AC waveforms (16-bit mode)
tAXQX
tBHQV
A0-AMAX
BYTE#
tAVQV
tBLQX
tBLQZ
VALID
Hi-Z
A–1
DATA OUT
DATA OUT
VALID
DQ0-DQ7
DQ8-DQ15
Byte_Transition_AC-Waveform
AI08971
c
tEHQZ
tGHQX
VALID
A4-Amax
OE#
DQ0-DQ15
CE#
tELQV tEHQX
tGHQZ
VALID
A0-A3 VALID VALID VALID VALID
VALID VALID VALID
tGLQV
tAVQV
tAVQV1
VALID VALID VALID
VALID VALID VALID
Table 23. Read AC characteristics
Symbol Alt. Parameter Test
condition Limit M29EW Unit
Fortified BGA TSOP
tAVAV tRC Address Valid to Next
Address Valid CE# = VIL,
OE# = VIL Min 100 110 ns
tAVQV tACC Address Valid to Output
Valid CE# = VIL,
OE# = VIL Max 100 110 ns
tAVQV1 tPAGE Address Valid to Output
Valid (Page) CE# = VIL,
OE# = VIL Max 25 ns
tELQX(1) tLZ Chip Enable Low to Output
Transition OE# = VIL Min 0 ns
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 67
Figure 21. Write Enable Controlled Program waveforms (8-bit mode)
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit and by a read operation that outputs the data, DOUT, programmed by the previous
tELQV tEChip Enable Low to Output
Valid OE# = VIL Max 100 110 ns
tGLQX(1) tOLZ Output Enable Low to
Output Transition CE# = VIL Min 0 ns
tGLQV tOE Output Enable Low to
Output Valid CE# = VIL Max 25 ns
tEHQZ(1) tHZ Chip Enable High to Output
Hi-Z OE# = VIL Max 20 ns
tGHQZ(1) tDF Output Enable High to
Output Hi-Z CE# = VIL Max 15 ns
tEHQX
tGHQX
tAXQX
tOH
Chip Enable, Output Enab le
or Address Transition to
Output Transition -Min 0 ns
tELBL
tELBH
tELFL
tELFH
Chip Enable to BYTE# Low
or High - Max 10 ns
tBLQV tFLQV BYTE# Low to Output Valid - Max 1 µs
tBHQV tFHQV BYTE# High to Output Valid - Max 1 µs
1. Sampled only, not 100% tested.
Table 23. Read AC characteristics
Symbol Alt. Parameter Test
condition Limit M29EW Unit
Fortified BGA TSOP
AI13333
OE#
WE#
A0-Amax/A–1
DQ0-DQ7
CE#
AAAh
AOh
PA PA
3rd cycle 4th cycle
PD DQ7 DOUT
DOUT
tAVAV tAVAV
tAVWL tWLAX
D a ta Pollin g Read cycle
tELWL tWHEH tELQV
tGHWL
tWLWH tWHWL
tWHWH1
tGLQV
tDVWH
tWHDX
tGHQZ tAXQX
DC and AC Parameters Numonyx™ Axcell™ M29EW
68 208045-11
Program command.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. SeeTable 24: Write AC characteristics, Write Enable Controlled, Table 25: Write AC characteristics, Chip Enable
Controlled and Table 23: Read AC characteristics for details on the timings.
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 69
Figure 22. Write Enable Controlled Program waveforms (16-bit mode)
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit and by a read operation that outputs the data, DOUT, programmed by the previous
Program command.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. SeeTable 24: Write AC characteristics, Write Enable Controlled, Table 25: Write AC characteristics, Chip Enable
Controlled and Table 23: Read AC characteristics for details on the timings.
AI13699
OE#
WE#
A0-Amax
DQ0-DQ15
CE#
555h
AOh
PA PA
3rd cycle 4th cycle
PD DQ7 DOUT
DOUT
tAVAV tAVAV
tAVWL tWLAX
Data Polling Read cycle
tELWL tWHEH tELQV
tGHWL
tWLWH tWHWL
tGLQV
tDVWH
tWHDX
tGHQZ tAXQX
DC and AC Parameters Numonyx™ Axcell™ M29EW
70 208045-11
M
Table 24. Write AC characteristics, Write Enable Controlled
Symbol Alt Parameter Limit Fortified BGA TSOP Unit
tAVAV tWC Address Valid to Next Address Valid Min 100 110 ns
tELWL tCS Chip Enable Low to Write Enable Low Min 0 ns
tWLWH tWP Wr ite Enable Low to Write Enable High Min 35 ns
tDVWH(1) tDS Input Valid to Write Enable High Min 30 ns
tWHDX tDH Write Enable High to Input Transition Min 0 ns
tWHEH tCH Write Enable High to Chip Enable High Min 0 ns
tWHWL tWPH Write Enable High to Write Enable Low Min 20 ns
tAVWL tAS Address Valid to Write Enable Low Min 0 ns
tWLAX tAH Write Enable Low to Address Transition Min 45 ns
tGHWL - Output Enable High to Write Enable Low Min 0 ns
tWHGL tOEH Write Enable High to Output Enable Low Min 0 ns
tWHRL(2) tBUSY Program/Erase Valid to RY/BY# Low Max 30 ns
tVCHEL tVCS VCC High to Chip Enable Low Min 30 0 µs
tWHWH1 tWHWH1 write buffer program operation (512 Words) Typ 900 µs
program operation single word or byte Typ 210 µs
1. This specification must be complied with by customer’s writing timing. Any violation to this timing specification may damage
the flash device permanently.
2. Sampled only, not 100% tested.
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 71
Figure 23. Chip Enable Controlled Program waveforms (8-bit mode)
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. See Table 24: Write AC characteristics, Write Enable Controlled, Table 25: Write AC characteristics, Chip Enable
Controlled and Table 23: Read AC characteristics for details on the timings.
AI13334
OE#
CE#
A0-Amax/A–1
DQ0-DQ7
WE#
AAAh
AOh
PA PA
3rd cycle 4th cycle
PD DQ7 DOUT
tAVAV
tAVEL tELAX
D a ta Pollin g
tWLEL tEHWH
tGHEL
tELEH tEHEL1
tWHWH1
tDVEH
tEHDX
DC and AC Parameters Numonyx™ Axcell™ M29EW
72 208045-11
Figure 24. Chip Enable Controlled Program waveforms (16-bit mode)
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. See Table 24: Write AC characteristics, Write Enable Controlled, Table 25: Write AC characteristics, Chip Enable
Controlled and Table 23: Read AC characteristics for details on the timings.
AI14100
OE#
CE#
A0-Amax
DQ0-DQ15
WE#
555h
AOh
PA PA
3rd cycle 4th cycle
PD DQ7 DOUT
tAVAV
tAVEL tELAX
Data Polling
tWLEL tEHWH
tGHEL
tELEH tEHEL1
tDVEH
tEHDX
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 73
Figure 25. Chip/Block Erase waveforms (8-bit mode)
1. For a Chip Erase command, addresses and data are 555h and 10h, respectively, while they are BAd and 30h for a Block
Erase command.
2. BAd is the block address.
3. See Table 24: Write AC characteristics, Write Enable Controlled, Table 25: Write AC characteristics, Chip Enable
Controlled and Table 23: Read AC characteristics for details on the timings.
AI13335
OE#
WE#
DQ0-DQ7
CE#
555h
AAh
2AAh 555h
55h 80h AAh
tAVAV
tAVWL tWLAX
tELWL tWHEH
tGHWL
tWLWH tWHWL
tDVWH
tWHDX
555h 2AAh 555h/BAd
(1)
55h 10h/
30h
A0-Amax/A-1
Table 25. Write AC characteristics, Chip Enable Controlled
Symbol Alt. Parameter L imit Fortified BGA TSOP Unit
tAVAV tWC Address Valid to Next Address Valid Min 100 110 ns
tWLEL tWS Write Enable Low to Chip Enable Low M in 0 ns
tELEH tCP Chip Enable Low to Chip Enable High Min 35 ns
tDVEH(1) tDS Input Valid to Chip Enable High Min 3 0 ns
tEHDX tDH Chip Enable High to Input Transition Min 0 ns
tEHWH tWH Chip Enable High to Write Enable High Min 0 ns
tEHEL tCPH Chip Enable High to Chip Enable Low Min 20 ns
tAVEL tAS Address Valid to Chip Enable Low Min 0 ns
tELAX tAH Chip Enable Low to Address Transition Min 45 ns
tGHEL - Output Enable High Chip Enable Low Min 0 ns
tWHWH1 tWHWH1 write buffer program operation (512 Words) Typ 900 µs
program operation single word or byte Typ 210 µs
1. This specification must be complied with by customer’s writing timing. The result would be unpredictable if there’s any
violation to this timing specification.
DC and AC Parameters Numonyx™ Axcell™ M29EW
74 208045-11
Figure 26. Reset AC w aveforms (no program/erase in progress)
Figure 27. Reset during program/erase operation AC waveforms
AI11300b
RY/ BY#
RST# tPLPH
tPHEL,
tPHGL
CE#, OE#
AI11301b
RY/ BY#
RST#
tPLPH
tRHEL, tRHGL
CE#,OE#
tPLRH
Table 26. Reset AC characteristics
Symbol Alt. Parameter Min Max Unit
tPLRH(1) tREADY RST# Low to Read mode, during Program or Erase - 32 µs
tPLPH tRP RST# Pulse width 100 - ns
tPHEL, tPHGL(1) tRH RST# High to Write Enable Low, Chip Enable Low,
Output Enable Low 50 - ns
-t
RPD RST# Low to Standby mode, during Read mode 10 - µs
RST# Low to Standby mode, during Program or Erase 50 - µs
tRHEL, tRHGL(1) tRB RY/BY# High to Write Enable Low, Chip Enable Low,
Output Enable Low 0-ns
1. Sampled only, not 100% tested.
Numonyx™ Axcell™ M29EW DC and AC Parameters
208045-11 75
Figure 28. Accelerated program timing waveforms
Figure 29. Data polling AC waveforms
1. DQ7 returns valid data bit when the ongoing Program or Erase command is completed.
2. See Table 27: Accelerated Program and Data Polling/Data Toggle AC characteristics and Table 23: Read AC
characteristics for details on the timings.
AI05563
VPP/WP#
VPPH
VIL or VIH tVHVPP tVHVPP
AI13336c
OE#
CE#
DQ7
WE#
DQ6-DQ0
DATA
DATA
RY/BY#
tWHEH
tGLQV
tEHQZ
tGHQZ
tWHGL2
tELQV
tWHRL
Output Flag
Valid DQ7 Data
Valid DQ6-DQ0
Data
Output Flag
DQ7
DQ7
DC and AC Parameters Numonyx™ Axcell™ M29EW
76 208045-11
Figure 30. Toggle/Alternative Toggle bit polling AC waveforms (8-bit mode)
1. DQ6 stops toggling when the ongoing Program or Erase command is completed. DQ2 stops toggling when the in-progress
Chip Erase or Block Erase command is completed.
2. See Table 27: Accelerated Program and Data Polling/Data Toggle AC characteristics and Table 23: Read AC
characteristics for details on the timings.
AI13337
WE#
CE#
OE#
DQ6/DQ2 Toggle Toggle Toggle Stop
toggling Output
Valid
tGHAX tAXGL
tEHAX tAVEL
tEHEL2
tWHGL2
tGHGL2 tGHGL2
Data
RY/BY#
tWHDX tGLQV tELQV
tWHRL
A0-Amax/A-1
Table 27. Accelerated Program and Data Polling/Data Toggle AC characteristics
Symbol Alt Parameter Min Max Unit
tVHVPP -V
PP/WP# raising or falling time 250 - ns
tAXGL tASO Address setup time to Output Enable Low during
Toggle bit polling 15 - ns
tGHAX,
tEHAX tAHT Address hold time from Output Enable during
Toggle bit polling 0-ns
tEHEL2 tEPH Chip Enable High during Toggle bit poll ing 30 - ns
tWHGL2,
tGHGL2 tOEH Output Hold time during Data and Toggle bit polling 20 - ns
tWHRL tBUSY Program/Erase Valid to RY/BY# Low - 90 n s
Numonyx™ Axcell™ M29EW Programming and Erase Performance
208045-11 77
10 Programming and Erase Performance
Table 28. Programming and Erase Performance
Parameter Buffer
Size Byte Word Min Typ(1)(2) Max(2) Unit
Block Erase (128 kbytes) - - - - 0.8 4 s
Erase Suspend latency time - - - - 27 32 µs
Block Erase time-out - - - 50 - - µs
Byte Program
Single Byte
Program - - - - 210 456 µs
Byte Write to
Buffer Program
64 64 - - 270 716
µs128 128 - - 310 900
256 256 - - 375 1140
Effective Write to
Buffer Program
per Byte
64 1 - - 4.22 11.2
µs128 1 - - 2.42 7.00
256 1 - - 1.46 4.45
Wo rd Progr am
Single Word
Program - - - - 210 456 µs
Word Write to
Buffer Program
32 - 32 - 270 716
µs
64 - 64 - 310 900
128 - 128 - 375 1140
256 - 256 - 505 1690
512 - 512 - 900 3016
Effective Write to
Buffer Program
per Word
32 - 1 - 8.44 22.4
µs
64 - 1 - 4.84 14.1
128 - 1 - 2.93 8.90
256 - 1 - 1.97 6.60
512 - 1 - 1.76 5.89
Program Suspend latency time - - - - 27 32 µs
Blank Check - - - - 3.2 - m s
Program/Erase cycles (per block) - - - 100,000 - - Cycles
Erase to Suspend(3) ----500-µs
1. Typical values measured at room temperature and nominal voltages.
2. Sampled, but not 100% tested.
3. Erase to Suspend is a typical time between an initial block erase or erase resume command and the a subsequent erase
suspend command. Violating the specification repeatedly during any particular block erase may cause erase failures.
Package Mechanical Specifications Numonyx™ Axce ll™ M29EW
78 208045-11
11 Package Mechanical Specifications
Numonyx offers these devices in lead-free TSOP, lead-free Fortified BGA, and leaded
Fortified BGA packages. The category of second level interconnect is marked on the
package and on the inner box label, in compliance with JEDEC Standard JESD97. The
maximum r atings related to soldering conditions are also marked on the inner box label.
Figure 31. TSOP56 – 56 lead thin small-outline package, 14 x 20 mm, package
outline
1. Drawing is not to scale.
TSOP-b
D1
E
1 N
CP
B
e
A2
A
N/2
D
DIE
C
LA1 α
Table 29. TSOP56 – 56 lead thin small-outline package, 14 x 20 mm, package mechanical data
Symbol Millimeters Inches
Typ Min Max Typ Min Max
A 1.20 0.047
A1 0.10 0.05 0.15 0.004 0.002 0.006
A2 1.00 0.95 1.05 0.039 0.037 0.041
B(1) 0.22 0.17 0.27 0.0087 0.0067 0.0106
C 0.10 0.21 0.004 0.008
CP 0.10 0.004
E 14.00 13.90 14.10 0.551 0.547 0.555
D 20.00 19.80 20.20 0.787 0.780 0.795
D1 18.40 18.30 18.50 0.724 0.720 0.728
e 0.50 0.020
L 0.60 0.50 0.70 0.024 0.020 0.028
α30 5305
1. For legacy lead width, 0.15mm (Typ), 0.10mm (Min), 0.20mm (Max).
Numonyx™ Axcell™ M29EW Package Mechanical Specifications
208045-11 79
Figure 32. Fortified BGA64 11 x 13 mm - 8 x 8 active ball arra y, package outline
1. Drawing is not to scale.
2. Drawing is bottom view.
Table 30. Fortified BGA64 11 x 13 mm - 8 x 8 active ball array, package mechanical
data
Symbol millimeters
Typ Min Max
A– 1.40
A1 0.49 0.40
A2 0.80
b 0.60 0.55 0.65
D 11.00 10.90 11.10
D1 7.00
ddd 0.10
e1.00
E 13.00 12.90 13.10
E1 7.00
FD 2.00
FE 3.00
SD 0.50
SE 0.50
E1E
D1
D
eb
SD
SE
A2
A1
A
BGA-Z23
ddd
FD
FE
BALL "A1"
Ordering Information Numonyx™ Axcell™ M29EW
80 208045-11
12 Ordering Information
Note: This product is also available with the Extended Memory Block Numonyx pre-locked. For
further details and ordering information contact your nearest Numonyx sales office.
De vices are shipped from Numo nyx f actory with the memory content bits era sed to ‘1’. F or a
list of available options (package, High/Low protect, etc.) or for further information on any
aspect of the device, please contact your nearest Numonyx Sales Office.
Table 32. Valid Combinations of M29EW Part Numbers
Note: For further information on ordering products or for product part n umbers, go to:
http://www.numonyx.com/en-US/MemoryProducts/Pages/PartNumberLookup.aspx.
Table 31. Ordering information scheme
Example: RC 28F 256 M29EW H *
Package
RC = Fortified BGA64: 11 x 13 mm, leaded
JS = TSOP56: 14 x 20 mm, lead free, halogen free, RoHS compliant
PC = Fortified BGA64: 11 x 13 mm, lead free, halogen free, RoHS compliant
Discrete/SCSP
28F= NOR Parallel Interface
Device Density
256=256-Mbit
512=512-Mbit
00A=1-Gbit
00B=2-Gbit
Device Type
M29EW = 3V core, page, uniform block flash memory
Device function
H = highest block protected by VPP/WP#
L = lowest block protected by VPP/WP#
Device features
* = Random digit to cover a combination of features, including packing media,
special features, and specific customer request information.
256-Mbit 512-Mbit 1-Gbit 2-Gbit
JS28F256M29EWH* JS28F512M29EWH* JS28F00AM29EWH* JS28F00BM29EWH*
JS28F256M29EWL* JS28F512M29EWL* JS28F00AM29EWL* PC28F00BM29EWH*
PC28F256M29EWH* PC28F512M29EWH* PC28F00AM29EWH* RC28F00BM29EWH*
PC28F256M29EWL* PC28F512M29EWL* PC28F00AM29EWL*
RC28F256M29EWH* RC28F512M29EWH* RC28F00AM29EWH*
RC28F256M29EWL* RC28F512M29EWL* RC28F00AM29EWL*
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 81
Appendix A Memory Address Table
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
0 128 / 64 0000000-001FFFF 0000000-000FFFF
1 128 / 64 0020000-003FFFF 0010000-001FFFF
2 128 / 64 0040000-005FFFF 0020000-002FFFF
3 128 / 64 0060000-007FFFF 0030000-003FFFF
4 128 / 64 0080000-009FFFF 0040000-004FFFF
5 128 / 64 00A0000-00BFFFF 0050 000-005FFFF
6 128 / 64 00C0000-00DFFFF 0060000-006FFFF
7 128 / 64 00E0000-00FFFFF 0070000-007FFFF
8 128 / 64 0100000-011FFFF 0080000-008FFFF
9 128 / 64 0120000-013FFFF 0090000-009FFFF
10 128 / 64 0140000-015FFFF 00A0000-00AFFFF
11 128 / 64 0160000-017FFFF 00B0000-00BFFFF
12 128 / 64 0180000-019FFFF 00C0000-00CFFFF
13 128 / 64 01A0000-01BFFFF 00D0000-00DFFFF
14 128 / 64 01C0000-01DFFFF 00E0000-00EFFFF
15 128 / 64 01E0000-01FFFFF 00F0000-00FFFFF
16 128 / 64 0200000-021FFFF 0100000-0 10FFFF
17 128 / 64 0220000-023FFFF 0110000-0 11FFFF
18 128 / 64 0240000-025FFFF 0120000-0 12FFFF
19 128 / 64 0260000-027FFFF 0130000-0 13FFFF
20 128 / 64 0280000-029FFFF 0140000-0 14FFFF
21 128 / 64 02A0000-02BFFFF 0150000-015FFFF
22 128 / 64 02C0000-02DFFFF 0160000-016FFFF
23 128 / 64 02E0000-02FFFFF 0170000-017FFFF
24 128 / 64 0300000-031FFFF 0180000-0 18FFFF
25 128 / 64 0320000-033FFFF 0190000-0 19FFFF
26 128 / 64 0340000-035FFFF 01A0000-01AFFFF
27 128 / 64 0360000-037FFFF 01B0000-01BFFFF
28 128 / 64 0380000-039FFFF 01C0000-01CFFFF
29 128 / 64 03A0000-03BFFFF 01D0000-01DFFFF
30 128 / 64 03C0000-03DFFFF 01E0000-01EFFFF
Memory Address Tabl e Numonyx™ Axcell™ M29EW
82 208045-11
31 128 / 64 03E0000-03FFFFF 01F0000-01FFFFF
32 128 / 64 0400000-041FFFF 0200000-0 20FFFF
33 128 / 64 0420000-043FFFF 0210000-0 21FFFF
34 128 / 64 0440000-045FFFF 0220000-0 22FFFF
35 128 / 64 0460000-047FFFF 0230000-0 23FFFF
36 128 / 64 0480000-049FFFF 0240000-0 24FFFF
37 128 / 64 04A0000-04BFFFF 0250000-025FFFF
38 128 / 64 04C0000-04DFFFF 0260000-026FFFF
39 128 / 64 04E0000-04FFFFF 0270000-027FFFF
40 128 / 64 0500000-051FFFF 0280000-0 28FFFF
41 128 / 64 0520000-053FFFF 0290000-0 29FFFF
42 128 / 64 0540000-055FFFF 02A0000-02AFFFF
43 128 / 64 0560000-057FFFF 02B0000-02BFFFF
44 128 / 64 0580000-059FFFF 02C0000-02CFFFF
45 128 / 64 05A0000-05BFFFF 02D0000-02DFFFF
46 128 / 64 05C0000-05DFFFF 02E0000-02EFFFF
47 128 / 64 05E0000-05FFFFF 02F0000-02FFFFF
48 128 / 64 0600000-061FFFF 0300000-0 30FFFF
49 128 / 64 0620000-063FFFF 0310000-0 31FFFF
50 128 / 64 0640000-065FFFF 0320000-0 32FFFF
51 128 / 64 0660000-067FFFF 0330000-0 33FFFF
52 128 / 64 0680000-069FFFF 0340000-0 34FFFF
53 128 / 64 06A0000-06BFFFF 0350000-035FFFF
54 128 / 64 06C0000-06DFFFF 0360000-036FFFF
55 128 / 64 06E0000-06FFFFF 0370000-037FFFF
56 128 / 64 0700000-071FFFF 0380000-0 38FFFF
57 128 / 64 0720000-073FFFF 0390000-0 39FFFF
58 128 / 64 0740000-075FFFF 03A0000-03AFFFF
59 128 / 64 0760000-077FFFF 03B0000-03BFFFF
60 128 / 64 0780000-079FFFF 03C0000-03CFFFF
61 128 / 64 07A0000-07BFFFF 03D0000-03DFFFF
62 128 / 64 07C0000-07DFFFF 03E0000-03EFFFF
63 128 / 64 07E0000-07FFFFF 03F0000-03FFFFF
64 128 / 64 0800000-081FFFF 0400000-0 40FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 83
65 128 / 64 0820000-083FFFF 0410000-0 41FFFF
66 128 / 64 0840000-085FFFF 0420000-0 42FFFF
67 128 / 64 0860000-087FFFF 0430000-0 43FFFF
68 128 / 64 0880000-089FFFF 0440000-0 44FFFF
69 128 / 64 08A0000-08BFFFF 0450000-045FFFF
70 128 / 64 08C0000-08DFFFF 0460000-046FFFF
71 128 / 64 08E0000-08FFFFF 0470000-047FFFF
72 128 / 64 0900000-091FFFF 0480000-0 48FFFF
73 128 / 64 0920000-093FFFF 0490000-0 49FFFF
74 128 / 64 0940000-095FFFF 04A0000-04AFFFF
75 128 / 64 0960000-097FFFF 04B0000-04BFFFF
76 128 / 64 0980000-099FFFF 04C0000-04CFFFF
77 128 / 64 09A0000-09BFFFF 04D0000-04DFFFF
78 128 / 64 09C0000-09DFFFF 04E0000-04EFFFF
79 128 / 64 09E0000-09FFFFF 04F0000-04FFFFF
80 128 / 64 0A00000-0A1FFFF 0500000-050FFFF
81 128 / 64 0A20000-0A3FFFF 0510000-051FFFF
82 128 / 64 0A40000-0A5FFFF 0520000-052FFFF
83 128 / 64 0A60000-0A7FFFF 0530000-053FFFF
84 128 / 64 0A80000-0A9FFFF 0540000-054FFFF
85 128 / 64 0AA0000-0ABFFFF 0550000-055FFFF
86 128 / 64 0AC0000-0ADFFFF 0560000-056FFFF
87 128 / 64 0AE0000-0AFFFFF 0570000-057FFFF
88 128 / 64 0B00000-0B1FFFF 0580000-058FFFF
89 128 / 64 0B20000-0B3FFFF 0590000-059FFFF
90 128 / 64 0B40000-0B5FFFF 05A0000-05AFFFF
91 128 / 64 0B60000-0B7FFFF 05B0000-05BFFFF
92 128 / 64 0B80000-0B9FFFF 05C0000-05CFFFF
93 128 / 64 0BA0000 -0BBFFFF 05D0000-05DFFFF
94 128 / 64 0BC0000-0BDFFFF 05E0000-05EFFFF
95 128 / 64 0BE0000-0BFFFFF 05F0000-05FFFFF
96 128 / 64 0C00000-0C1FFFF 0600000-060FFFF
97 128 / 64 0C20000-0C3FFFF 0610000-061FFFF
98 128 / 64 0C40000-0C5FFFF 0620000-062FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
84 208045-11
99 128 / 64 0C60000-0C7FFFF 0630000-063FFFF
100 128 / 64 0C80000 -0C9FFFF 0640000-064FFFF
101 128 / 64 0CA0000-0CBFFFF 0650000-065FFFF
102 128 / 64 0CC0000-0CDFFFF 0660 000-066FFFF
103 128 / 64 0CE0000-0CFFFFF 0670000-067FFFF
104 128 / 64 0D00000 -0D1FFFF 0680000-068FFFF
105 128 / 64 0D20000 -0D3FFFF 0690000-069FFFF
106 128 / 64 0D40000 -0D5FFFF 06A0000-0 6AFFFF
107 128 / 64 0D60000 -0D7FFFF 06B0000-0 6BFFFF
108 128 / 64 0D80000 -0D9FFFF 06C0000-06CFFFF
109 128 / 64 0DA0000-0DBFFFF 06D0000-06DFFFF
110 128 / 64 0DC0000-0DDFFFF 06E0 000-06EFFFF
111 128 / 64 0DE0000-0DFFFFF 0 6F0000-06FFFFF
112 128 / 64 0E00000-0E1FFFF 0700000-070FFFF
113 128 / 64 0E20000-0E3FFFF 0710000-071FFFF
114 128 / 64 0E40000-0E5FFFF 0720000-072FFFF
115 128 / 64 0E60000-0E7FFFF 0730000-073FFFF
116 128 / 64 0E80000-0E9FFFF 0740000-074FFFF
117 128 / 64 0EA0000-0EBFFFF 0750000-075FFFF
118 128 / 64 0EC0000-0EDFFFF 0760000-076FFFF
119 128 / 64 0EE0000-0EFFFFF 0770000-077FFFF
120 128 / 64 0F00000-0F1FFFF 0780000-078FFFF
121 128 / 64 0F20000-0F3FFFF 0790000-079FFFF
122 128 / 64 0F40000-0F5 FFFF 07A0000-07AFFFF
123 128 / 64 0F60000-0F7 FFFF 07B0000-07BFFFF
124 128 / 64 0F80000-0F9FFFF 07C0000-07CFFFF
125 128 / 64 0FA0000-0FBFFFF 07D0000-07DFFFF
126 128 / 64 0FC0000-0FDFFFF 07E0000-07EFFFF
127 128 / 64 0FE0000-0FFFFFF 07F0000-07FFFFF
128 128 / 64 1000000-101FFFF 0800000-080FFFF
129 128 / 64 1020000-103FFFF 0810000-081FFFF
130 128 / 64 1040000-105FFFF 0820000-082FFFF
131 128 / 64 1060000-107FFFF 0830000-083FFFF
132 128 / 64 1080000-109FFFF 0840000-084FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 85
133 128 / 64 10A0000-10BFFFF 0850000-085FFFF
134 128 / 64 10C0000-10DFFFF 0860000-086FFFF
135 128 / 64 10E0000-10FFFFF 0870000-087FFFF
136 128 / 64 1100000-111FFFF 0880000-088FFFF
137 128 / 64 1120000-113FFFF 0890000-089FFFF
138 128 / 64 1140000-115FFFF 08A0000-08AFFFF
139 128 / 64 1160000-117FFFF 08B0000-08BFFFF
140 128 / 64 1180000-119FFFF 08C0000-08CFFFF
141 128 / 64 11A0000-11BFFFF 08D0000-08DFFFF
142 128 / 64 11C0000-11DFFFF 08E0000-08EFFFF
143 128 / 64 11E0000-11FFFFF 08F0000-08FFFFF
144 128 / 64 1200000-121FFFF 0900000-090FFFF
145 128 / 64 1220000-123FFFF 0910000-091FFFF
146 128 / 64 1240000-125FFFF 0920000-092FFFF
147 128 / 64 1260000-127FFFF 0930000-093FFFF
148 128 / 64 1280000-129FFFF 0940000-094FFFF
149 128 / 64 12A0000-12BFFFF 0950000-095FFFF
150 128 / 64 12C0000-12DFFFF 0960000-096FFFF
151 128 / 64 12E0000-12FFFFF 0970000-097FFFF
152 128 / 64 1300000-131FFFF 0980000-098FFFF
153 128 / 64 1320000-133FFFF 0990000-099FFFF
154 128 / 64 1340000-135FFFF 09A0000-09AFFFF
155 128 / 64 1360000-137FFFF 09B0000-09BFFFF
156 128 / 64 1380000-139FFFF 09C0000-09CFFFF
157 128 / 64 13A0000-13BFFFF 09D0000-09DFFFF
158 128 / 64 13C0000-13DFFFF 09E0000-09EFFFF
159 128 / 64 13E0000-13FFFFF 09F0000-09FFFFF
160 128 / 64 1400000-141FFFF 0A00000-0A0FFFF
161 128 / 64 1420000-143FFFF 0A10000-0A1FFFF
162 128 / 64 1440000-145FFFF 0A20000-0A2FFFF
163 128 / 64 1460000-147FFFF 0A30000-0A3FFFF
164 128 / 64 1480000-149FFFF 0A40000-0A4FFFF
165 128 / 64 14 A0000-14BFFFF 0A50000-0A5FFFF
166 128 / 64 14C0000-14DFFFF 0A60000-0 A6FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
86 208045-11
167 128 / 64 14E0000-14FFFFF 0A70000-0A7FFFF
168 128 / 64 1500000-151FFFF 0A80000-0A8FFFF
169 128 / 64 1520000-153FFFF 0A90000-0A9FFFF
170 128 / 64 1540000-155FFFF 0AA0000 -0AAFFFF
171 128 / 64 1560000-157FFFF 0AB0000 -0ABFFFF
172 128 / 64 1580000-159FFFF 0AC0 000-0ACFFFF
173 128 / 64 15A0000-15BFFFF 0AD0 000-0ADFFFF
174 128 / 64 15C0000 -15DFFFF 0AE0000-0AEFFFF
175 128 / 64 15E0000-15FFFFF 0AF0000-0AFFFFF
176 128 / 64 1600000-161FFFF 0B00000-0B0FFFF
177 128 / 64 1620000-163FFFF 0B10000-0B1FFFF
178 128 / 64 1640000-165FFFF 0B20000-0B2FFFF
179 128 / 64 1660000-167FFFF 0B30000-0B3FFFF
180 128 / 64 1680000-169FFFF 0B40000-0B4FFFF
181 128 / 64 16 A0000-16BFFFF 0B50000-0B5FFFF
182 128 / 64 16C0000-16DFFFF 0B60000-0B6FFFF
183 128 / 64 16E0000-16FFFFF 0B70000-0B7FFFF
184 128 / 64 1700000-171FFFF 0B80000-0B8FFFF
185 128 / 64 1720000-173FFFF 0B90000-0B9FFFF
186 128 / 64 1740000-175FFFF 0BA0000 -0BAFFFF
187 128 / 64 1760000-177FFFF 0BB0000 -0BBFFFF
188 128 / 64 1780000-179FFFF 0BC0000-0BCFFFF
189 128 / 64 17A0000-17BFFFF 0BD0 000-0BDFFFF
190 128 / 64 17C0000 -17DFFFF 0BE0000-0BEFFFF
191 128 / 64 17E0000-17FFFFF 0BF0000-0BFFFFF
192 128 / 64 1800000-181FFFF 0C00 000-0C0FFFF
193 128 / 64 1820000-183FFFF 0C10 000-0C1FFFF
194 128 / 64 1840000-185FFFF 0C20 000-0C2FFFF
195 128 / 64 1860000-187FFFF 0C30 000-0C3FFFF
196 128 / 64 1880000-189FFFF 0C40 000-0C4FFFF
197 128 / 64 18A0000-18BFFFF 0C50000-0C5FFFF
198 128 / 64 18C0000 -18DFFFF 0C60000-0C6FFFF
199 128 / 64 18E0000-18FFFFF 0C70000-0C7FFFF
200 128 / 64 1900000-191FFFF 0C80 000-0C8FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 87
201 128 / 64 1920000-193FFFF 0C90 000-0C9FFFF
202 128 / 64 1940000-195FFFF 0CA0000-0CAFFFF
203 128 / 64 1960000-197FFFF 0CB0000-0CBFFFF
204 128 / 64 1980000-199FFFF 0CC0000-0CCFFFF
205 128 / 64 19A0000-19BFFFF 0CD0000 -0CDFFFF
206 128 / 64 19C0000-19DFFFF 0CE0000-0CEFFFF
207 128 / 64 19E0000-19FFFFF 0CF0000-0CFFFFF
208 128 / 64 1A00000-1A1FFFF 0D00000-0D0FFFF
209 128 / 64 1A20000-1A3FFFF 0D10000-0D1FFFF
210 128 / 64 1A40000-1A5FFFF 0D20000-0D2FFFF
211 128 / 64 1A60000-1A7FFFF 0D30000-0D3FFFF
212 128 / 64 1A80000-1A9FFFF 0D40000-0D4FFFF
213 128 / 64 1AA0000-1ABFFFF 0D50000-0D5FFFF
214 128 / 64 1AC0000-1ADFFFF 0D60000-0D6FFFF
215 128 / 64 1AE0000-1AFFFFF 0D70000-0D7FFFF
216 128 / 64 1B00000-1B1FFFF 0D80000-0D8FFFF
217 128 / 64 1B20000-1B3FFFF 0D90000-0D9FFFF
218 128 / 64 1B40000-1B5FFFF 0DA0000-0DAFFFF
219 128 / 64 1B60000-1B7FFFF 0DB0 000-0DBFFFF
220 128 / 64 1B80000-1B9FFFF 0DC0000 -0DCFFFF
221 128 / 64 1BA0000-1BBFFFF 0DD0000-0DDFFFF
222 128 / 64 1BC0000-1BDFFFF 0DE0000-0DEFFFF
223 128 / 64 1BE0000-1BFFFFF 0DF0000-0DFFFFF
224 128 / 64 1C00000 -1C1FFFF 0E00000-0 E0FFFF
225 128 / 64 1C20000 -1C3FFFF 0E10000-0 E1FFFF
226 128 / 64 1C40000 -1C5FFFF 0E20000-0 E2FFFF
227 128 / 64 1C60000 -1C7FFFF 0E30000-0 E3FFFF
228 128 / 64 1C80000 -1C9FFFF 0E40000-0 E4FFFF
229 128 / 64 1CA0000-1CBFFFF 0E50000-0E5FFFF
230 128 / 64 1CC0000-1CDFFFF 0E60 000-0E6FFFF
231 128 / 64 1CE0000-1CFFFFF 0E70000-0E7FFFF
232 128 / 64 1D00000 -1D1FFFF 0E80000-0 E8FFFF
233 128 / 64 1D20000 -1D3FFFF 0E90000-0 E9FFFF
234 128 / 64 1D40000 -1D5FFFF 0EA0000-0EAFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
88 208045-11
235 128 / 64 1D60000 -1D7FFFF 0EB0000-0EBFFFF
236 128 / 64 1D80000 -1D9FFFF 0EC0000-0 ECFFFF
237 128 / 64 1DA0000-1DBFFFF 0ED0000-0EDFFFF
238 128 / 64 1DC0000-1DDFFFF 0EE0000-0EEFFFF
239 128 / 64 1DE0000-1DFFFFF 0EF0000-0EFFFFF
240 128 / 64 1E00000-1E1FFFF 0F00000-0F0FFFF
241 128 / 64 1E20000-1E3FFFF 0F10000-0F1FFFF
242 128 / 64 1E40000-1E5FFFF 0F20000-0F2FFFF
243 128 / 64 1E60000-1E7FFFF 0F30000-0F3FFFF
244 128 / 64 1E80000-1E9FFFF 0F40000-0F4FFFF
245 128 / 64 1EA0000-1EBFFFF 0F50000-0F5FFFF
246 128 / 64 1EC0000-1EDFFFF 0F60000-0F6FFFF
247 128 / 64 1EE0000-1EFFFFF 0F70000-0F7FFFF
248 128 / 64 1F00000-1F1FFFF 0F80000-0F8FFFF
249 128 / 64 1F20000-1F3FFFF 0F90000-0F9FFFF
250 128 / 64 1F40000-1F5FFFF 0FA0000-0FAFFFF
251 128 / 64 1F60000-1F7FFFF 0FB0000-0FBFFFF
252 128 / 64 1F80000-1F9FFFF 0FC0000-0FCFFFF
253 128 / 64 1FA0000-1FBFFFF 0FD0000-0FDFFFF
254 128 / 64 1FC0000-1FDFFFF 0FE0000-0FEFFFF
255 128 / 64 1FE0000-1FFFFFF 0FF0000-0FFFFFF
256 128 / 64 2000000-201FFFF 1000000-100FFFF
257 128 / 64 2020000-203FFFF 1010000-101FFFF
258 128 / 64 2040000-205FFFF 1020000-102FFFF
259 128 / 64 2060000-207FFFF 1030000-103FFFF
260 128 / 64 2080000-209FFFF 1040000-104FFFF
261 128 / 64 20A0000-20BFFFF 1050000-105FFFF
262 128 / 64 20C0000-20DFFFF 1060000-106FFFF
263 128 / 64 20E0000-20FFFFF 1070000-107FFFF
264 128 / 64 2100000-211FFFF 1080000-108FFFF
265 128 / 64 2120000-213FFFF 1090000-109FFFF
266 128 / 64 2140000-215FFFF 10A0000-10AFFFF
267 128 / 64 2160000-217FFFF 10B0000-10BFFFF
268 128 / 64 2180000-219FFFF 10C0000-10CFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 89
269 128 / 64 21A0000-21BFFFF 10D0000-10DFFFF
270 128 / 64 21C0000-21DFFFF 10E0000-10EFFFF
271 128 / 64 21E0000-21FFFFF 10F0000-10FFFFF
272 128 / 64 2200000-221FFFF 1100000-110FFFF
273 128 / 64 2220000-223FFFF 1110000-111FFFF
274 128 / 64 2240000-225FFFF 1120000-112FFFF
275 128 / 64 2260000-227FFFF 1130000-113FFFF
276 128 / 64 2280000-229FFFF 1140000-114FFFF
277 128 / 64 22A0000-22BFFFF 1150000-115FFFF
278 128 / 64 22C0000-22DFFFF 1160000-116FFFF
279 128 / 64 22E0000-22FFFFF 1170000-117FFFF
280 128 / 64 2300000-231FFFF 1180000-118FFFF
281 128 / 64 2320000-233FFFF 1190000-119FFFF
282 128 / 64 2340000-235FFFF 11A0000-11AFFFF
283 128 / 64 2360000-237FFFF 11B0000-11BFFFF
284 128 / 64 2380000-239FFFF 11C0000-11CFFFF
285 128 / 64 23A0000-23BFFFF 11D0000-11DFFFF
286 128 / 64 23C0000-23DFFFF 11E0000-11EFFFF
287 128 / 64 23E0000-23FFFFF 11F0000-11FFFFF
288 128 / 64 2400000-241FFFF 1200000-120FFFF
289 128 / 64 2420000-243FFFF 1210000-121FFFF
290 128 / 64 2440000-245FFFF 1220000-122FFFF
291 128 / 64 2460000-247FFFF 1230000-123FFFF
292 128 / 64 2480000-249FFFF 1240000-124FFFF
293 128 / 64 24A0000-24BFFFF 1250000-125FFFF
294 128 / 64 24C0000-24DFFFF 1260000-126FFFF
295 128 / 64 24E0000-24FFFFF 1270000-127FFFF
296 128 / 64 2500000-251FFFF 1280000-128FFFF
297 128 / 64 2520000-253FFFF 1290000-129FFFF
298 128 / 64 2540000-255FFFF 12A0000-12AFFFF
299 128 / 64 2560000-257FFFF 12B0000-12BFFFF
300 128 / 64 2580000-259FFFF 12C0000-12CFFFF
301 128 / 64 25A0000-25BFFFF 12D0000-12DFFFF
302 128 / 64 25C0000-25DFFFF 12E0000-12EFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
90 208045-11
303 128 / 64 25E0000-25FFFFF 12F0000-12FFFFF
304 128 / 64 2600000-261FFFF 1300000-130FFFF
305 128 / 64 2620000-263FFFF 1310000-131FFFF
306 128 / 64 2640000-265FFFF 1320000-132FFFF
307 128 / 64 2660000-267FFFF 1330000-133FFFF
308 128 / 64 2680000-269FFFF 1340000-134FFFF
309 128 / 64 26A0000-26BFFFF 1350000-135FFFF
310 128 / 64 26C0000-26DFFFF 1360000-136FFFF
311 128 / 64 26E0000-26FFFFF 1370000-137FFFF
312 128 / 64 2700000-271FFFF 1380000-138FFFF
313 128 / 64 2720000-273FFFF 1390000-139FFFF
314 128 / 64 2740000-275FFFF 13A0000-13AFFFF
315 128 / 64 2760000-277FFFF 13B0000-13BFFFF
316 128 / 64 2780000-279FFFF 13C0000-13CFFFF
317 128 / 64 27A0000-27BFFFF 13D0000-13DFFFF
318 128 / 64 27C0000-27DFFFF 13E0000-13EFFFF
319 128 / 64 27E0000-27FFFFF 13F0000-13FFFFF
320 128 / 64 2800000-281FFFF 1400000-140FFFF
321 128 / 64 2820000-283FFFF 1410000-141FFFF
322 128 / 64 2840000-285FFFF 1420000-142FFFF
323 128 / 64 2860000-287FFFF 1430000-143FFFF
324 128 / 64 2880000-289FFFF 1440000-144FFFF
325 128 / 64 28A0000-28BFFFF 1450000-145FFFF
326 128 / 64 28C0000-28DFFFF 1460000-146FFFF
327 128 / 64 28E0000-28FFFFF 1470000-147FFFF
328 128 / 64 2900000-291FFFF 1480000-148FFFF
329 128 / 64 2920000-293FFFF 1490000-149FFFF
330 128 / 64 2940000-295FFFF 14A0000-14AFFFF
331 128 / 64 2960000-297FFFF 14B0000-14BFFFF
332 128 / 64 2980000-299FFFF 14C0000-14CFFFF
333 128 / 64 29A0000-29BFFFF 14D0000-14DFFFF
334 128 / 64 29C0000-29DFFFF 14E0000-14EFFFF
335 128 / 64 29E0000-29FFFFF 14F0000-14FFFFF
336 128 / 64 2A00000-2A1FFFF 1500000-150FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 91
337 128 / 64 2A20000-2A3FFFF 1510000-151FFFF
338 128 / 64 2A40000-2A5FFFF 1520000-152FFFF
339 128 / 64 2A60000-2A7FFFF 1530000-153FFFF
340 128 / 64 2A80000-2A9FFFF 1540000-154FFFF
341 128 / 64 2AA0000-2ABFFFF 1550000-155FFFF
342 128 / 64 2AC0000-2ADFFFF 1560000-156FFFF
343 128 / 64 2AE0000-2AFFFFF 1570000-157FFFF
344 128 / 64 2B00000-2B1FFFF 1580000-158FFFF
345 128 / 64 2B20000-2B3FFFF 1590000-159FFFF
346 128 / 64 2B4 0000-2B5FFFF 15A0000-15AFFFF
347 128 / 64 2B6 0000-2B7FFFF 15B0000-15BFFFF
348 128 / 64 2B80000-2B9FFFF 15C0000-15CFFFF
349 128 / 64 2BA0000-2BBFFFF 15D0 000-15DFFFF
350 128 / 64 2BC0000-2BDFFFF 15E0000-15EFFFF
351 128 / 64 2BE0000-2BFFFFF 15F0000-15FFFFF
352 128 / 64 2C00000 -2C1FFFF 1600000-160FFFF
353 128 / 64 2C20000 -2C3FFFF 1610000-161FFFF
354 128 / 64 2C40000 -2C5FFFF 1620000-162FFFF
355 128 / 64 2C60000 -2C7FFFF 1630000-163FFFF
356 128 / 64 2C80000 -2C9FFFF 1640000-164FFFF
357 128 / 64 2CA0000-2CBFFFF 1650000-165FFFF
358 128 / 64 2CC0000-2CDFFFF 1660 000-166FFFF
359 128 / 64 2CE0000-2CFFFFF 1670000-167FFFF
360 128 / 64 2D00000 -2D1FFFF 1680000-068FFFF
361 128 / 64 2D20000 -2D3FFFF 1690000-169FFFF
362 128 / 64 2D40000 -2D5FFFF 16A0000-1 6AFFFF
363 128 / 64 2D60000 -2D7FFFF 16B0000-1 6BFFFF
364 128 / 64 2D80000 -2D9FFFF 16C0000-16CFFFF
365 128 / 64 2DA0000-2DBFFFF 16D0000-16DFFFF
366 128 / 64 2DC0000-2DDFFFF 16E0 000-16EFFFF
367 128 / 64 2DE0000-2DFFFFF 1 6F0000-16FFFFF
368 128 / 64 2E00000-2E1FFFF 1700000-170FFFF
369 128 / 64 2E20000-2E3FFFF 1710000-171FFFF
370 128 / 64 2E40000-2E5FFFF 1720000-172FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
92 208045-11
371 128 / 64 2E60000-2E7FFFF 1730000-173FFFF
372 128 / 64 2E80000-2E9FFFF 1740000-174FFFF
373 128 / 64 2EA0000-2EBFFFF 1750000-175FFFF
374 128 / 64 2EC0000-2EDFFFF 1760000-176FFFF
375 128 / 64 2EE0000-2EFFFFF 1770000-177FFFF
376 128 / 64 2F00000-2F1FFFF 1780000-178FFFF
377 128 / 64 2F20000-2F3FFFF 1790000-179FFFF
378 128 / 64 2F40000-2F5 FFFF 17A0000-17AFFFF
379 128 / 64 2F60000-2F7 FFFF 17B0000-17BFFFF
380 128 / 64 2F80000-2F9FFFF 17C0000-17CFFFF
381 128 / 64 2FA0000-2FBFFFF 17D0000-17DFFFF
382 128 / 64 2FC0000-2FDFFFF 17E0000-17EFFFF
383 128 / 64 2FE0000-2FFFFFF 17F0000-17FFFFF
384 128 / 64 3000000-301FFFF 1800000-180FFFF
385 128 / 64 3020000-303FFFF 1810000-181FFFF
386 128 / 64 3040000-305FFFF 1820000-182FFFF
387 128 / 64 3060000-307FFFF 1830000-183FFFF
388 128 / 64 3080000-309FFFF 1840000-184FFFF
389 128 / 64 30A0000-30BFFFF 1850000-185FFFF
390 128 / 64 30C0000-30DFFFF 1860000-186FFFF
391 128 / 64 30E0000-30FFFFF 1870000-187FFFF
392 128 / 64 3100000-311FFFF 1880000-188FFFF
393 128 / 64 3120000-313FFFF 1890000-189FFFF
394 128 / 64 3140000-315FFFF 18A0000-18AFFFF
395 128 / 64 3160000-317FFFF 18B0000-18BFFFF
396 128 / 64 3180000-319FFFF 18C0000-18CFFFF
397 128 / 64 31A0000-31BFFFF 18D0000-18DFFFF
398 128 / 64 31C0000-31DFFFF 18E0000-18EFFFF
399 128 / 64 31E0000-31FFFFF 18F0000-18FFFFF
400 128 / 64 3200000-321FFFF 1900000-190FFFF
401 128 / 64 3220000-323FFFF 1910000-191FFFF
402 128 / 64 3240000-325FFFF 1920000-192FFFF
403 128 / 64 3260000-327FFFF 1930000-193FFFF
404 128 / 64 3280000-329FFFF 1940000-194FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 93
405 128 / 64 32A0000-32BFFFF 1950000-195FFFF
406 128 / 64 32C0000-32DFFFF 1960000-196FFFF
407 128 / 64 32E0000-32FFFFF 1970000-197FFFF
408 128 / 64 3300000-331FFFF 1980000-198FFFF
409 128 / 64 3320000-333FFFF 1990000-199FFFF
410 128 / 64 3340000-335FFFF 19A0000-19AFFFF
411 128 / 64 3360000-337FFFF 19B0000-19BFFFF
412 128 / 64 3380000-339FFFF 19C0000-19CFFFF
413 128 / 64 33A0000-33BFFFF 19D0000-19DFFFF
414 128 / 64 33C0000-33DFFFF 19E0000-19EFFFF
415 128 / 64 33E0000-33FFFFF 19F0000-19FFFFF
416 128 / 64 3400000-341FFFF 1A00000-1A0FFFF
417 128 / 64 3420000-343FFFF 1A10000-1A1FFFF
418 128 / 64 3440000-345FFFF 1A20000-1A2FFFF
419 128 / 64 3460000-347FFFF 1A30000-1A3FFFF
420 128 / 64 3480000-349FFFF 1A40000-1A4FFFF
421 128 / 64 34 A0000-34BFFFF 1A50000-1A5FFFF
422 128 / 64 34C0000-34DFFFF 1A60000-1 A6FFFF
423 128 / 64 34E0000-34FFFFF 1A70000-1A7FFFF
424 128 / 64 3500000-351FFFF 1A80000-1A8FFFF
425 128 / 64 3520000-353FFFF 1A90000-1A9FFFF
426 128 / 64 3540000-355FFFF 1AA0000 -1AAFFFF
427 128 / 64 3560000-357FFFF 1AB0000 -1ABFFFF
428 128 / 64 3580000-359FFFF 1AC0 000-1ACFFFF
429 128 / 64 35A0000-35BFFFF 1AD0 000-1ADFFFF
430 128 / 64 35C0000 -35DFFFF 1AE0000-1AEFFFF
431 128 / 64 35E0000-35FFFFF 1AF0000-1AFFFFF
432 128 / 64 3600000-361FFFF 1B00000-1B0FFFF
433 128 / 64 3620000-363FFFF 1B10000-1B1FFFF
434 128 / 64 3640000-365FFFF 1B20000-1B2FFFF
435 128 / 64 3660000-367FFFF 1B30000-1B3FFFF
436 128 / 64 3680000-369FFFF 1B40000-1B4FFFF
437 128 / 64 36 A0000-36BFFFF 1B50000-1B5FFFF
438 128 / 64 36C0000-36DFFFF 1B60000-1B6FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
94 208045-11
439 128 / 64 36E0000-36FFFFF 1B70000-1B7FFFF
440 128 / 64 3700000-371FFFF 1B80000-1B8FFFF
441 128 / 64 3720000-373FFFF 1B90000-1B9FFFF
442 128 / 64 3740000-375FFFF 1BA0000 -1BAFFFF
443 128 / 64 3760000-377FFFF 1BB0000 -1BBFFFF
444 128 / 64 3780000-379FFFF 1BC0000-1BCFFFF
445 128 / 64 37A0000-37BFFFF 1BD0 000-1BDFFFF
446 128 / 64 37C0000 -37DFFFF 1BE0000-1BEFFFF
447 128 / 64 37E0000-37FFFFF 1BF0000-1BFFFFF
448 128 / 64 3800000-381FFFF 1C00 000-1C0FFFF
449 128 / 64 3820000-383FFFF 1C10 000-1C1FFFF
450 128 / 64 3840000-385FFFF 1C20 000-1C2FFFF
451 128 / 64 3860000-387FFFF 1C30 000-1C3FFFF
452 128 / 64 3880000-389FFFF 1C40 000-1C4FFFF
453 128 / 64 38A0000-38BFFFF 1C50000-1C5FFFF
454 128 / 64 38C0000 -38DFFFF 1C60000-1C6FFFF
455 128 / 64 38E0000-38FFFFF 1C70000-1C7FFFF
456 128 / 64 3900000-391FFFF 1C80 000-1C8FFFF
457 128 / 64 3920000-393FFFF 1C90 000-1C9FFFF
458 128 / 64 3940000-395FFFF 1CA0000-1CAFFFF
459 128 / 64 3960000-397FFFF 1CB0000-1CBFFFF
460 128 / 64 3980000-399FFFF 1CC0000-1CCFFFF
461 128 / 64 39A0000-39BFFFF 1CD0000 -1CDFFFF
462 128 / 64 39C0000-39DFFFF 1CE0000-1CEFFFF
463 128 / 64 39E0000-39FFFFF 1CF0000-1CFFFFF
464 128 / 64 3A00000-3A1FFFF 1D00000-1D0FFFF
465 128 / 64 3A20000-3A3FFFF 1D10000-1D1FFFF
466 128 / 64 3A40000-3A5FFFF 1D20000-1D2FFFF
467 128 / 64 3A60000-3A7FFFF 1D30000-1D3FFFF
468 128 / 64 3A80000-3A9FFFF 1D40000-1D4FFFF
469 128 / 64 3AA0000-3ABFFFF 1D50000-1D5FFFF
470 128 / 64 3AC0000-3ADFFFF 1D60000-1D6FFFF
471 128 / 64 3AE0000-3AFFFFF 1D70000-1D7FFFF
472 128 / 64 3B00000-3B1FFFF 1D80000-1D8FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 95
473 128 / 64 3B20000-3B3FFFF 1D90000-1D9FFFF
474 128 / 64 3B40000-3B5FFFF 1DA0000-1DAFFFF
475 128 / 64 3B60000-3B7FFFF 1DB0 000-1DBFFFF
476 128 / 64 3B80000-3B9FFFF 1DC0000 -1DCFFFF
477 128 / 64 3BA0000-3BBFFFF 1DD0000-1DDFFFF
478 128 / 64 3BC0000-3BDFFFF 1DE0000-1DEFFFF
479 128 / 64 3BE0000-3BFFFFF 1DF0000-1DFFFFF
480 128 / 64 3C00000 -3C1FFFF 1E00000-1 E0FFFF
481 128 / 64 3C20000 -3C3FFFF 1E10000-1 E1FFFF
482 128 / 64 3C40000 -3C5FFFF 1E20000-1 E2FFFF
483 128 / 64 3C60000 -3C7FFFF 1E30000-1 E3FFFF
484 128 / 64 3C80000 -3C9FFFF 1E40000-1 E4FFFF
485 128 / 64 3CA0000-3CBFFFF 1E50000-1E5FFFF
486 128 / 64 3CC0000-3CDFFFF 1E60 000-1E6FFFF
487 128 / 64 3CE0000-3CFFFFF 1E70000-1E7FFFF
488 128 / 64 3D00000 -3D1FFFF 1E80000-1 E8FFFF
489 128 / 64 3D20000 -3D3FFFF 1E90000-1 E9FFFF
490 128 / 64 3D40000 -3D5FFFF 1EA0000-1EAFFFF
491 128 / 64 3D60000 -3D7FFFF 1EB0000-1EBFFFF
492 128 / 64 3D80000 -3D9FFFF 1EC0000-1 ECFFFF
493 128 / 64 3DA0000-3DBFFFF 1ED0000-1EDFFFF
494 128 / 64 3DC0000-3DDFFFF 1EE0000-1EEFFFF
495 128 / 64 3DE0000-3DFFFFF 1EF0000-1EFFFFF
496 128 / 64 3E00000-3E1FFFF 1F00000-1F0FFFF
497 128 / 64 3E20000-3E3FFFF 1F10000-1F1FFFF
498 128 / 64 3E40000-3E5FFFF 1F20000-1F2FFFF
499 128 / 64 3E60000-3E7FFFF 1F30000-1F3FFFF
500 128 / 64 3E80000-3E9FFFF 1F40000-1F4FFFF
501 128 / 64 3EA0000-3EBFFFF 1F50000-1F5FFFF
502 128 / 64 3EC0000-3EDFFFF 1F60000-1F6FFFF
503 128 / 64 3EE0000-3EFFFFF 1F70000-1F7FFFF
504 128 / 64 3F00000-3F1FFFF 1F80000-1F8FFFF
505 128 / 64 3F20000-3F3FFFF 1F90000-1F9FFFF
506 128 / 64 3F40000-3F5FFFF 1FA0000-1FAFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
96 208045-11
507 128 / 64 3F60000-3F7FFFF 1FB0000-1FBFFFF
508 128 / 64 3F80000-3F9FFFF 1FC0000-1FCFFFF
509 128 / 64 3FA0000-3FBFFFF 1FD0000-1FDFFFF
510 128 / 64 3FC0000-3FDFFFF 1FE0000-1FEFFFF
511 128 / 64 3FE0000-3FFFFFF 1FF0000-1FFFFFF
512 128 / 64 4000000-401FFFF 2000000-200FFFF
513 128 / 64 4020000-403FFFF 2010000-201FFFF
514 128 / 64 4040000-405FFFF 2020000-202FFFF
515 128 / 64 4060000-407FFFF 2030000-203FFFF
516 128 / 64 4080000-409FFFF 2040000-204FFFF
517 128 / 64 40A0000-40BFFFF 2050000-205FFFF
518 128 / 64 40C0000-40DFFFF 2060000-206FFFF
519 128 / 64 40E0000-40FFFFF 2070000-207FFFF
520 128 / 64 4100000-411FFFF 2080000-208FFFF
521 128 / 64 4120000-413FFFF 2090000-209FFFF
522 128 / 64 4140000-415FFFF 20A0000-20AFFFF
523 128 / 64 4160000-417FFFF 20B0000-20BFFFF
524 128 / 64 4180000-419FFFF 20C0000-20CFFFF
525 128 / 64 41A0000-41BFFFF 20D0000-20DFFFF
526 128 / 64 41C0000-41DFFFF 20E0000-20EFFFF
527 128 / 64 41E0000-41FFFFF 20F0000-20FFFFF
528 128 / 64 4200000-421FFFF 2100000-210FFFF
529 128 / 64 4220000-423FFFF 2110000-211FFFF
530 128 / 64 4240000-425FFFF 2120000-212FFFF
531 128 / 64 4260000-427FFFF 2130000-213FFFF
532 128 / 64 4280000-429FFFF 2140000-214FFFF
533 128 / 64 42A0000-42BFFFF 2150000-215FFFF
534 128 / 64 42C0000-42DFFFF 2160000-216FFFF
535 128 / 64 42E0000-42FFFFF 2170000-217FFFF
536 128 / 64 4300000-431FFFF 2180000-218FFFF
537 128 / 64 4320000-433FFFF 2190000-219FFFF
538 128 / 64 4340000-435FFFF 21A0000-21AFFFF
539 128 / 64 4360000-437FFFF 21B0000-21BFFFF
540 128 / 64 4380000-439FFFF 21C0000-21CFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 97
541 128 / 64 43A0000-43BFFFF 21D0000-21DFFFF
542 128 / 64 43C0000-43DFFFF 21E0000-21EFFFF
543 128 / 64 43E0000-43FFFFF 21F0000-21FFFFF
544 128 / 64 4400000-441FFFF 2200000-220FFFF
545 128 / 64 4420000-443FFFF 2210000-221FFFF
546 128 / 64 4440000-445FFFF 2220000-222FFFF
547 128 / 64 4460000-447FFFF 2230000-223FFFF
548 128 / 64 4480000-449FFFF 2240000-224FFFF
549 128 / 64 44A0000-44BFFFF 2250000-225FFFF
550 128 / 64 44C0000-44DFFFF 2260000-226FFFF
551 128 / 64 44E0000-44FFFFF 2270000-227FFFF
552 128 / 64 4500000-451FFFF 2280000-228FFFF
553 128 / 64 4520000-453FFFF 2290000-229FFFF
554 128 / 64 4540000-455FFFF 22A0000-22AFFFF
555 128 / 64 4560000-457FFFF 22B0000-22BFFFF
556 128 / 64 4580000-459FFFF 22C0000-22CFFFF
557 128 / 64 45A0000-45BFFFF 22D0000-22DFFFF
558 128 / 64 45C0000-45DFFFF 22E0000-22EFFFF
559 128 / 64 45E0000-45FFFFF 22F0000-22FFFFF
560 128 / 64 4600000-461FFFF 2300000-230FFFF
561 128 / 64 4620000-463FFFF 2310000-231FFFF
562 128 / 64 4640000-465FFFF 2320000-232FFFF
563 128 / 64 4660000-467FFFF 2330000-233FFFF
564 128 / 64 4680000-469FFFF 2340000-234FFFF
565 128 / 64 46A0000-46BFFFF 2350000-235FFFF
566 128 / 64 46C0000-46DFFFF 2360000-236FFFF
567 128 / 64 46E0000-46FFFFF 2370000-237FFFF
568 128 / 64 4700000-471FFFF 2380000-238FFFF
569 128 / 64 4720000-473FFFF 2390000-239FFFF
570 128 / 64 4740000-475FFFF 23A0000-23AFFFF
571 128 / 64 4760000-477FFFF 23B0000-23BFFFF
572 128 / 64 4780000-479FFFF 23C0000-23CFFFF
573 128 / 64 47A0000-47BFFFF 23D0000-23DFFFF
574 128 / 64 47C0000-47DFFFF 23E0000-23EFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
98 208045-11
575 128 / 64 47E0000-47FFFFF 23F0000-23FFFFF
576 128 / 64 4800000-481FFFF 2400000-240FFFF
577 128 / 64 4820000-483FFFF 2410000-241FFFF
578 128 / 64 4840000-485FFFF 2420000-242FFFF
579 128 / 64 4860000-487FFFF 2430000-243FFFF
580 128 / 64 4880000-489FFFF 2440000-244FFFF
581 128 / 64 48A0000-48BFFFF 2450000-245FFFF
582 128 / 64 48C0000 -48DFFFF 2460000246FFFF
583 128 / 64 48E0000-48FFFFF 2470000-247FFFF
584 128 / 64 4900000-491FFFF 2480000-248FFFF
585 128 / 64 4920000-493FFFF 2490000-249FFFF
586 128 / 64 4940000-495FFFF 24A0000-24AFFFF
587 128 / 64 4960000-497FFFF 24B0000-24BFFFF
588 128 / 64 4980000-499FFFF 24C0000-24CFFFF
589 128 / 64 49A0000-49BFFFF 24D0000-24DFFFF
590 128 / 64 49C0000-49DFFFF 24E0000-24EFFFF
591 128 / 64 49E0000-49FFFFF 24F0000-24FFFFF
592 128 / 64 4A00000-4A1FFFF 2500000-250FFFF
593 128 / 64 4A20000-4A3FFFF 2510000-251FFFF
594 128 / 64 4A40000-4A5FFFF 2520000-252FFFF
595 128 / 64 4A60000-4A7FFFF 2530000-253FFFF
596 128 / 64 4A80000-4A9FFFF 2540000-254FFFF
597 128 / 64 4AA0000-4ABFFFF 2550000-255FFFF
598 128 / 64 4AC0000-4ADFFFF 2560000-256FFFF
599 128 / 64 4AE0000-4AFFFFF 2570000-257FFFF
600 128 / 64 4B00000-4B1FFFF 2580000-258FFFF
601 128 / 64 4B20000-4B3FFFF 2590000-259FFFF
602 128 / 64 4B4 0000-4B5FFFF 25A0000-25AFFFF
603 128 / 64 4B6 0000-4B7FFFF 25B0000-25BFFFF
604 128 / 64 4B80000-4B9FFFF 25C0000-25CFFFF
605 128 / 64 4BA0000-4BBFFFF 25D0 000-25DFFFF
606 128 / 64 4BC0000-4BDFFFF 25E0000-25EFFFF
607 128 / 64 4BE0000-4BFFFFF 25F0000-25FFFFF
608 128 / 64 4C00000 -4C1FFFF 2600000-260FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 99
609 128 / 64 4C20000 -4C3FFFF 2610000-261FFFF
610 128 / 64 4C40000 -4C5FFFF 2620000-262FFFF
611 128 / 64 4C60000 -4C7FFFF 2630000-263FFFF
612 128 / 64 4C80000 -4C9FFFF 2640000-264FFFF
613 128 / 64 4CA0000-4CBFFFF 2650000-265FFFF
614 128 / 64 4CC0000-4CDFFFF 2660 000-266FFFF
615 128 / 64 4CE0000-4CFFFFF 2670000-267FFFF
616 128 / 64 4D00000 -4D1FFFF 2680000-268FFFF
617 128 / 64 4D20000 -4D3FFFF 2690000-269FFFF
618 128 / 64 4D40000 -4D5FFFF 26A0000-2 6AFFFF
619 128 / 64 4D60000 -4D7FFFF 26B0000-2 6BFFFF
620 128 / 64 4D80000 -4D9FFFF 26C0000-26CFFFF
621 128 / 64 4DA0000-4DBFFFF 26D0000-26DFFFF
622 128 / 64 4DC0000-4DDFFFF 26E0 000-26EFFFF
623 128 / 64 4DE0000-4DFFFFF 2 6F0000-26FFFFF
624 128 / 64 4E00000-4E1FFFF 2700000-270FFFF
625 128 / 64 4E20000-4E3FFFF 2710000-271FFFF
626 128 / 64 4E40000-4E5FFFF 2720000-272FFFF
627 128 / 64 4E60000-4E7FFFF 2730000-273FFFF
628 128 / 64 4E80000-4E9FFFF 2740000-274FFFF
629 128 / 64 4EA0000-4EBFFFF 2750000-275FFFF
630 128 / 64 4EC0000-4EDFFFF 2760000-276FFFF
631 128 / 64 4EE0000-4EFFFFF 2770000-277FFFF
632 128 / 64 4F00000-4F1FFFF 2780000-278FFFF
633 128 / 64 4F20000-4F3FFFF 2790000-279FFFF
634 128 / 64 4F40000-4F5 FFFF 27A0000-27AFFFF
635 128 / 64 4F60000-4F7 FFFF 27B0000-27BFFFF
636 128 / 64 4F80000-4F9FFFF 27C0000-27CFFFF
637 128 / 64 4FA0000-4FBFFFF 27D0000-27DFFFF
638 128 / 64 4FC0000-4FDFFFF 27E0000-27EFFFF
639 128 / 64 4FE0000-4FFFFFF 27F0000-27FFFFF
640 128 / 64 5000000-501FFFF 2800000-280FFFF
641 128 / 64 5020000-503FFFF 2810000-281FFFF
642 128 / 64 5040000-505FFFF 2820000-282FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
100 208045-11
643 128 / 64 5060000-507FFFF 2830000-283FFFF
644 128 / 64 5080000-509FFFF 2840000-284FFFF
645 128 / 64 50A0000-50BFFFF 2850000-285FFFF
646 128 / 64 50C0000-50DFFFF 2860000-286FFFF
647 128 / 64 50E0000-50FFFFF 2870000-287FFFF
648 128 / 64 5100000-511FFFF 2880000-288FFFF
649 128 / 64 5120000-513FFFF 2890000-289FFFF
650 128 / 64 5140000-515FFFF 28A0000-28AFFFF
651 128 / 64 5160000-517FFFF 28B0000-28BFFFF
652 128 / 64 5180000-519FFFF 28C0000-28CFFFF
653 128 / 64 51A0000-51BFFFF 28D0000-28DFFFF
654 128 / 64 51C0000-51DFFFF 28E0000-28EFFFF
655 128 / 64 51E0000-51FFFFF 28F0000-28FFFFF
656 128 / 64 5200000-521FFFF 2900000-290FFFF
657 128 / 64 5220000-523FFFF 2910000-291FFFF
658 128 / 64 5240000-525FFFF 2920000-292FFFF
659 128 / 64 5260000-527FFFF 2930000-293FFFF
660 128 / 64 5280000-529FFFF 2940000-294FFFF
661 128 / 64 52A0000-52BFFFF 2950000-295FFFF
662 128 / 64 52C0000-52DFFFF 2960000-296FFFF
663 128 / 64 52E0000-52FFFFF 2970000-297FFFF
664 128 / 64 5300000-531FFFF 2980000-298FFFF
665 128 / 64 5320000-533FFFF 2990000-299FFFF
666 128 / 64 5340000-535FFFF 29A0000-29AFFFF
667 128 / 64 5360000-537FFFF 29B0000-29BFFFF
668 128 / 64 5380000-539FFFF 29C0000-29CFFFF
669 128 / 64 53A0000-53BFFFF 29D0000-29DFFFF
670 128 / 64 53C0000-53DFFFF 29E0000-29EFFFF
671 128 / 64 53E0000-53FFFFF 29F0000-29FFFFF
672 128 / 64 5400000-541FFFF 2A00000-2A0FFFF
673 128 / 64 5420000-543FFFF 2A10000-2A1FFFF
674 128 / 64 5440000-545FFFF 2A20000-2A2FFFF
675 128 / 64 5460000-547FFFF 2A30000-2A3FFFF
676 128 / 64 5480000-549FFFF 2A40000-2A4FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 101
677 128 / 64 54 A0000-54BFFFF 2A50000-2A5FFFF
678 128 / 64 54C0000-54DFFFF 2A60000-2A6FFFF
679 128 / 64 54E0000-54FFFFF 2A70000-2A7FFFF
680 128 / 64 5500000-551FFFF 2A80000-2A8FFFF
681 128 / 64 5520000-553FFFF 2A90000-2A9FFFF
682 128 / 64 5540000-555FFFF 2AA0000 -2AAFFFF
683 128 / 64 5560000-557FFFF 2AB0000 -2ABFFFF
684 128 / 64 5580000-559FFFF 2AC0 000-2ACFFFF
685 128 / 64 55A0000-55BFFFF 2AD0 000-2ADFFFF
686 128 / 64 55C0000 -55DFFFF 2AE0000-2AEFFFF
687 128 / 64 55E0000-55FFFFF 2AF0000-2AFFFFF
688 128 / 64 5600000-561FFFF 2B00000-2B0FFFF
689 128 / 64 5620000-563FFFF 2B10000-2B1FFFF
690 128 / 64 5640000-565FFFF 2B20000-2B2FFFF
691 128 / 64 5660000-567FFFF 2B30000-2B3FFFF
692 128 / 64 5680000-569FFFF 2B40000-2B4FFFF
693 128 / 64 56 A0000-56BFFFF 2B50000-2B5FFFF
694 128 / 64 56C0000-56DFFFF 2B60000-2B6FFFF
695 128 / 64 56E0000-56FFFFF 2B70000-2B7FFFF
696 128 / 64 5700000-571FFFF 2B80000-2B8FFFF
697 128 / 64 5720000-573FFFF 2B90000-2B9FFFF
698 128 / 64 5740000-575FFFF 2BA0000 -2BAFFFF
699 128 / 64 5760000-577FFFF 2BB0000 -2BBFFFF
700 128 / 64 5780000-579FFFF 2BC0000-2BCFFFF
701 128 / 64 57A0000-57BFFFF 2BD0 000-2BDFFFF
702 128 / 64 57C0000 -57DFFFF 2BE0000-2BEFFFF
703 128 / 64 57E0000-57FFFFF 2BF0000-2BFFFFF
704 128 / 64 5800000-581FFFF 2C00 000-2C0FFFF
705 128 / 64 5820000-583FFFF 2C10 000-2C1FFFF
706 128 / 64 5840000-585FFFF 2C20 000-2C2FFFF
707 128 / 64 5860000-587FFFF 2C30 000-2C3FFFF
708 128 / 64 5880000-589FFFF 2C40 000-2C4FFFF
709 128 / 64 58A0000-58BFFFF 2C50000-2C5FFFF
710 128 / 64 58C0000 -58DFFFF 2C60000-2C6FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
102 208045-11
711 128 / 64 58E0000-58FFFFF 2C70000-2C7FFFF
712 128 / 64 5900000-591FFFF 2C80 000-2C8FFFF
713 128 / 64 5920000-593FFFF 2C90 000-2C9FFFF
714 128 / 64 5940000-595FFFF 2CA0000-2CAFFFF
715 128 / 64 5960000-597FFFF 2CB0000-2CBFFFF
716 128 / 64 5980000-599FFFF 2CC0000-2CCFFFF
717 128 / 64 59A0000-59BFFFF 2CD0000 -2CDFFFF
718 128 / 64 59C0000-59DFFFF 2CE0000-2CEFFFF
719 128 / 64 59E0000-59FFFFF 2CF0000-2CFFFFF
720 128 / 64 5A00000-5A1FFFF 2D00000-2D0FFFF
721 128 / 64 5A20000-5A3FFFF 2D10000-2D1FFFF
722 128 / 64 5A40000-5A5FFFF 2D20000-2D2FFFF
723 128 / 64 5A60000-5A7FFFF 2D30000-2D3FFFF
724 128 / 64 5A80000-5A9FFFF 2D40000-2D4FFFF
725 128 / 64 5AA0000-5ABFFFF 2D50000-2D5FFFF
726 128 / 64 5AC0000-5ADFFFF 2D60000-2D6FFFF
727 128 / 64 5AE0000-5AFFFFF 2D70000-2D7FFFF
728 128 / 64 5B00000-5B1FFFF 2D80000-2D8FFFF
729 128 / 64 5B20000-5B3FFFF 2D90000-2D9FFFF
730 128 / 64 5B40000-5B5FFFF 2DA0000-2DAFFFF
731 128 / 64 5B60000-5B7FFFF 2DB0 000-2DBFFFF
732 128 / 64 5B80000-5B9FFFF 2DC0000 -2DCFFFF
733 128 / 64 5BA0000-5BBFFFF 2DD0000-2DDFFFF
734 128 / 64 5BC0000-5BDFFFF 2DE0000-2DEFFFF
735 128 / 64 5BE0000-5BFFFFF 2DF0000-2DFFFFF
736 128 / 64 5C00000 -5C1FFFF 2E00000-2 E0FFFF
737 128 / 64 5C20000 -5C3FFFF 2E10000-2 E1FFFF
738 128 / 64 5C40000 -5C5FFFF 2E20000-2 E2FFFF
739 128 / 64 5C60000 -5C7FFFF 2E30000-2 E3FFFF
740 128 / 64 5C80000 -5C9FFFF 2E40000-2 E4FFFF
741 128 / 64 5CA0000-5CBFFFF 2E50000-2E5FFFF
742 128 / 64 5CC0000-5CDFFFF 2E60 000-2E6FFFF
743 128 / 64 5CE0000-5CFFFFF 2E70000-2E7FFFF
744 128 / 64 5D00000 -5D1FFFF 2E80000-2 E8FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 103
745 128 / 64 5D20000 -5D3FFFF 2E90000-2 E9FFFF
746 128 / 64 5D40000 -5D5FFFF 2EA0000-2EAFFFF
747 128 / 64 5D60000 -5D7FFFF 2EB0000-2EBFFFF
748 128 / 64 5D80000 -5D9FFFF 2EC0000-2 ECFFFF
749 128 / 64 5DA0000-5DBFFFF 2ED0000-2EDFFFF
750 128 / 64 5DC0000-5DDFFFF 2EE0000-2EEFFFF
751 128 / 64 5DE0000-5DFFFFF 2EF0000-2EFFFFF
752 128 / 64 5E00000-5E1FFFF 2F00000-2F0FFFF
753 128 / 64 5E20000-5E3FFFF 2F10000-2F1FFFF
754 128 / 64 5E40000-5E5FFFF 2F20000-2F2FFFF
755 128 / 64 5E60000-5E7FFFF 2F30000-2F3FFFF
756 128 / 64 5E80000-5E9FFFF 2F40000-2F4FFFF
757 128 / 64 5EA0000-5EBFFFF 2F50000-2F5FFFF
758 128 / 64 5EC0000-5EDFFFF 2F60000-2F6FFFF
759 128 / 64 5EE0000-5EFFFFF 2F70000-2F7FFFF
760 128 / 64 5F00000-5F1FFFF 2F80000-2F8FFFF
761 128 / 64 5F20000-5F3FFFF 2F90000-2F9FFFF
762 128 / 64 5F40000-5F5FFFF 22FA00002FAFFFF
763 128 / 64 5F60000-5F7FFFF 2FB0000-2FBFFFF
764 128 / 64 5F80000-5F9FFFF 2FC0000-2FCFFFF
765 128 / 64 5FA0000-5FBFFFF 2FD0000-2FDFFFF
766 128 / 64 5FC0000-5FDFFFF 2FE0000-2FEFFFF
767 128 / 64 5FE0000-5FFFFFF 2FF0000-2FFFFFF
768 128 / 64 6000000-601FFFF 3000000-300FFFF
769 128 / 64 6020000-603FFFF 3010000-301FFFF
770 128 / 64 6040000-605FFFF 3020000-302FFFF
771 128 / 64 6060000-607FFFF 3030000-303FFFF
772 128 / 64 6080000-609FFFF 3040000-304FFFF
773 128 / 64 60A0000-60BFFFF 3050000-305FFFF
774 128 / 64 60C0000-60DFFFF 3060000-306FFFF
775 128 / 64 60E0000-60FFFFF 3070000-307FFFF
776 128 / 64 6100000-611FFFF 3080000-308FFFF
777 128 / 64 6120000-613FFFF 3090000-309FFFF
778 128 / 64 6140000-615FFFF 30A0000-30AFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
104 208045-11
779 128 / 64 6160000-617FFFF 30B0000-30BFFFF
780 128 / 64 6180000-619FFFF 30C0000-30CFFFF
781 128 / 64 61A0000-61BFFFF 30D0000-30DFFFF
782 128 / 64 61C0000-61DFFFF 30E0000-30EFFFF
783 128 / 64 61E0000-61FFFFF 30F0000-30FFFFF
784 128 / 64 6200000-621FFFF 3100000-310FFFF
785 128 / 64 6220000-623FFFF 3110000-311FFFF
786 128 / 64 6240000-625FFFF 3120000-312FFFF
787 128 / 64 6260000-627FFFF 3130000-313FFFF
788 128 / 64 6280000-629FFFF 3140000-314FFFF
789 128 / 64 62A0000-62BFFFF 3150000-315FFFF
790 128 / 64 62C0000-62DFFFF 3160000-316FFFF
791 128 / 64 62E0000-62FFFFF 3170000-317FFFF
792 128 / 64 6300000-631FFFF 3180000-318FFFF
793 128 / 64 6320000-633FFFF 3190000-319FFFF
794 128 / 64 6340000-635FFFF 31A0000-31AFFFF
795 128 / 64 6360000-637FFFF 31B0000-31BFFFF
796 128 / 64 6380000-639FFFF 31C0000-31CFFFF
797 128 / 64 63A0000-63BFFFF 31D0000-31DFFFF
798 128 / 64 63C0000-63DFFFF 31E0000-31EFFFF
799 128 / 64 63E0000-63FFFFF 31F0000-31FFFFF
800 128 / 64 6400000-641FFFF 3200000-320FFFF
801 128 / 64 6420000-643FFFF 3210000-321FFFF
802 128 / 64 6440000-645FFFF 3220000-322FFFF
803 128 / 64 6460000-647FFFF 3230000-323FFFF
804 128 / 64 6480000-649FFFF 3240000-324FFFF
805 128 / 64 64A0000-64BFFFF 3250000-325FFFF
806 128 / 64 64C0000-64DFFFF 3260000-326FFFF
807 128 / 64 64E0000-64FFFFF 3270000-327FFFF
808 128 / 64 6500000-651FFFF 3280000-328FFFF
809 128 / 64 6520000-653FFFF 3290000-329FFFF
810 128 / 64 6540000-655FFFF 32A0000-32AFFFF
811 128 / 64 6560000-657FFFF 32B0000-32BFFFF
812 128 / 64 6580000-659FFFF 32C0000-32CFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 105
813 128 / 64 65A0000-65BFFFF 32D0000-32DFFFF
814 128 / 64 65C0000-65DFFFF 32E0000-32EFFFF
815 128 / 64 65E0000-65FFFFF 32F0000-32FFFFF
816 128 / 64 6600000-661FFFF 3300000-330FFFF
817 128 / 64 6620000-663FFFF 3310000-331FFFF
818 128 / 64 6640000-665FFFF 3320000-332FFFF
819 128 / 64 6660000-667FFFF 3330000-333FFFF
820 128 / 64 6680000-669FFFF 3340000-334FFFF
821 128 / 64 66A0000-66BFFFF 3350000-335FFFF
822 128 / 64 66C0000-66DFFFF 3360000-336FFFF
823 128 / 64 66E0000-66FFFFF 3370000-337FFFF
824 128 / 64 6700000-671FFFF 3380000-338FFFF
825 128 / 64 6720000-673FFFF 3390000-339FFFF
826 128 / 64 6740000-675FFFF 33A0000-33AFFFF
827 128 / 64 6760000-677FFFF 33B0000-33BFFFF
828 128 / 64 6780000-679FFFF 33C0000-33CFFFF
829 128 / 64 67A0000-67BFFFF 33D0000-33DFFFF
830 128 / 64 67C0000-67DFFFF 33E0000-33EFFFF
831 128 / 64 67E0000-67FFFFF 33F0000-33FFFFF
832 128 / 64 6800000-681FFFF 3400000-340FFFF
833 128 / 64 6820000-683FFFF 3410000-341FFFF
834 128 / 64 6840000-685FFFF 3420000-342FFFF
835 128 / 64 6860000-687FFFF 3430000-343FFFF
836 128 / 64 6880000-689FFFF 3440000-344FFFF
837 128 / 64 68A0000-68BFFFF 3450000-345FFFF
838 128 / 64 68C0000-68DFFFF 3460000-346FFFF
839 128 / 64 68E0000-68FFFFF 3470000-347FFFF
840 128 / 64 6900000-691FFFF 3480000-348FFFF
841 128 / 64 6920000-693FFFF 3490000-349FFFF
842 128 / 64 6940000-695FFFF 34A0000-34AFFFF
843 128 / 64 6960000-697FFFF 34B0000-34BFFFF
844 128 / 64 6980000-699FFFF 34C0000-34CFFFF
845 128 / 64 69A0000-69BFFFF 34D0000-34DFFFF
846 128 / 64 69C0000-69DFFFF 34E0000-34EFFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
106 208045-11
847 128 / 64 69E0000-69FFFFF 34F0000-34FFFFF
848 128 / 64 6A00000-6A1FFFF 3500000-350FFFF
849 128 / 64 6A20000-6A3FFFF 3510000-351FFFF
850 128 / 64 6A40000-6A5FFFF 3520000-352FFFF
851 128 / 64 6A60000-6A7FFFF 3530000-353FFFF
852 128 / 64 6A80000-6A9FFFF 3540000-354FFFF
853 128 / 64 6AA0000-6ABFFFF 3550000-355FFFF
854 128 / 64 6AC0000-6ADFFFF 3560000-356FFFF
855 128 / 64 6AE0000-6AFFFFF 3570000-357FFFF
856 128 / 64 6B00000-6B1FFFF 3580000-358FFFF
857 128 / 64 6B20000-6B3FFFF 3590000-359FFFF
858 128 / 64 6B4 0000-6B5FFFF 35A0000-35AFFFF
859 128 / 64 6B6 0000-6B7FFFF 35B0000-35BFFFF
860 128 / 64 6B80000-6B9FFFF 35C0000-35CFFFF
861 128 / 64 6BA0000-6BBFFFF 35D0 000-35DFFFF
862 128 / 64 6BC0000-6BDFFFF 35E0000-35EFFFF
863 128 / 64 6BE0000-6BFFFFF 35F0000-35FFFFF
864 128 / 64 6C00000 -6C1FFFF 3600000-360FFFF
865 128 / 64 6C20000 -6C3FFFF 3610000-361FFFF
866 128 / 64 6C40000 -6C5FFFF 3620000-362FFFF
867 128 / 64 6C60000 -6C7FFFF 3630000-363FFFF
868 128 / 64 6C80000 -6C9FFFF 3640000-364FFFF
869 128 / 64 6CA0000-6CBFFFF 3650000-365FFFF
870 128 / 64 6CC0000-6CDFFFF 3660 000-366FFFF
871 128 / 64 6CE0000-6CFFFFF 3670000-367FFFF
872 128 / 64 6D00000 -6D1FFFF 3680000-368FFFF
873 128 / 64 6D20000 -6D3FFFF 3690000-369FFFF
874 128 / 64 6D40000 -6D5FFFF 36A0000-3 6AFFFF
875 128 / 64 6D60000 -6D7FFFF 36B0000-3 6BFFFF
876 128 / 64 6D80000 -6D9FFFF 36C0000-36CFFFF
877 128 / 64 6DA0000-6DBFFFF 36D0000-36DFFFF
878 128 / 64 6DC0000-6DDFFFF 36E0 000-36EFFFF
879 128 / 64 6DE0000-6DFFFFF 3 6F0000-36FFFFF
880 128 / 64 6E00000-6E1FFFF 3700000-370FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 107
881 128 / 64 6E20000-6E3FFFF 3710000-371FFFF
882 128 / 64 6E40000-6E5FFFF 3720000-372FFFF
883 128 / 64 6E60000-6E7FFFF 3730000-373FFFF
884 128 / 64 6E80000-6E9FFFF 3740000-374FFFF
885 128 / 64 6EA0000-6EBFFFF 3750000-375FFFF
886 128 / 64 6EC0000-6EDFFFF 3760000-376FFFF
887 128 / 64 6EE0000-6EFFFFF 3770000-377FFFF
888 128 / 64 6F00000-6F1FFFF 3780000-378FFFF
889 128 / 64 6F20000-6F3FFFF 3790000-379FFFF
890 128 / 64 6F40000-6F5 FFFF 37A0000-37AFFFF
891 128 / 64 6F60000-6F7 FFFF 37B0000-37BFFFF
892 128 / 64 6F80000-6F9FFFF 37C0000-37CFFFF
893 128 / 64 6FA0000-6FBFFFF 37D0000-37DFFFF
894 128 / 64 6FC0000-6FDFFFF 37E0000-37EFFFF
895 128 / 64 6FE0000-6FFFFFF 37F0000-37FFFFF
896 128 / 64 7000000-701FFFF 3800000-380FFFF
897 128 / 64 7020000-703FFFF 3810000-381FFFF
898 128 / 64 7040000-705FFFF 3820000-382FFFF
899 128 / 64 7060000-707FFFF 3830000-383FFFF
900 128 / 64 7080000-709FFFF 3840000-384FFFF
901 128 / 64 70A0000-70BFFFF 3850000-385FFFF
902 128 / 64 70C0000-70DFFFF 3860000-386FFFF
903 128 / 64 70E0000-70FFFFF 3870000-387FFFF
904 128 / 64 7100000-711FFFF 3880000-388FFFF
905 128 / 64 7120000-713FFFF 3890000-389FFFF
906 128 / 64 7140000-715FFFF 38A0000-38AFFFF
907 128 / 64 7160000-717FFFF 38B0000-38BFFFF
908 128 / 64 7180000-719FFFF 38C0000-38CFFFF
909 128 / 64 71A0000-71BFFFF 38D0000-38DFFFF
910 128 / 64 71C0000-71DFFFF 38E0000-38EFFFF
911 128 / 64 71E0000-71FFFFF 38F0000-38FFFFF
912 128 / 64 7200000-721FFFF 3900000-390FFFF
913 128 / 64 7220000-723FFFF 3910000-391FFFF
914 128 / 64 7240000-725FFFF 3920000-392FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
108 208045-11
915 128 / 64 7260000-727FFFF 3930000-393FFFF
916 128 / 64 7280000-729FFFF 3940000-394FFFF
917 128 / 64 72A0000-72BFFFF 3950000-395FFFF
918 128 / 64 72C0000-72DFFFF 3960000-396FFFF
919 128 / 64 72E0000-72FFFFF 3970000-397FFFF
920 128 / 64 7300000-731FFFF 3980000-398FFFF
921 128 / 64 7320000-733FFFF 3990000-399FFFF
922 128 / 64 7340000-735FFFF 39A0000-39AFFFF
923 128 / 64 7360000-737FFFF 39B0000-39BFFFF
924 128 / 64 7380000-739FFFF 39C0000-39CFFFF
925 128 / 64 73A0000-73BFFFF 39D0000-39DFFFF
926 128 / 64 73C0000-73DFFFF 39E0000-39EFFFF
927 128 / 64 73E0000-73FFFFF 39F0000-39FFFFF
928 128 / 64 7400000-741FFFF 3A00000-3A0FFFF
929 128 / 64 7420000-743FFFF 3A10000-3A1FFFF
930 128 / 64 7440000-745FFFF 3A20000-3A2FFFF
931 128 / 64 7460000-747FFFF 3A30000-3A3FFFF
932 128 / 64 7480000-749FFFF 3A40000-3A4FFFF
933 128 / 64 74 A0000-74BFFFF 3A50000-3A5FFFF
934 128 / 64 74C0000-74DFFFF 3A60000-3 A6FFFF
935 128 / 64 74E0000-74FFFFF 3A70000-3A7FFFF
936 128 / 64 7500000-751FFFF 3A80000-3A8FFFF
937 128 / 64 7520000-753FFFF 3A90000-3A9FFFF
938 128 / 64 7540000-755FFFF 3AA0000 -3AAFFFF
939 128 / 64 7560000-757FFFF 3AB0000 -3ABFFFF
940 128 / 64 7580000-759FFFF 3AC0000-3ACFFFF
941 128 / 64 75A0000-75BFFFF 3AD0 000-3ADFFFF
942 128 / 64 75C0000 -75DFFFF 3AE0000-3AEFFFF
943 128 / 64 75E0000-75FFFFF 3AF0000-3AFFFFF
944 128 / 64 7600000-761FFFF 3B00000-3B0FFFF
945 128 / 64 7620000-763FFFF 3B10000-3B1FFFF
946 128 / 64 7640000-765FFFF 3B20000-3B2FFFF
947 128 / 64 7660000-767FFFF 3B30000-3B3FFFF
948 128 / 64 7680000-769FFFF 3B40000-3B4FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 109
949 128 / 64 76 A0000-76BFFFF 3B50000-3B5FFFF
950 128 / 64 76C0000-76DFFFF 3B60000-3B6FFFF
951 128 / 64 76E0000-76FFFFF 3B70000-3B7FFFF
952 128 / 64 7700000-771FFFF 3B80000-3B8FFFF
953 128 / 64 7720000-773FFFF 3B90000-3B9FFFF
954 128 / 64 7740000-775FFFF 3BA0000 -3BAFFFF
955 128 / 64 7760000-777FFFF 3BB0000 -3BBFFFF
956 128 / 64 7780000-779FFFF 3BC0000-3BCFFFF
957 128 / 64 77A0000-77BFFFF 3BD0 000-3BDFFFF
958 128 / 64 77C0000 -77DFFFF 3BE0000-3BEFFFF
959 128 / 64 77E0000-77FFFFF 3BF0000-3BFFFFF
960 128 / 64 7800000-781FFFF 3C00 000-3C0FFFF
961 128 / 64 7820000-783FFFF 3C10 000-3C1FFFF
962 128 / 64 7840000-785FFFF 3C20 000-3C2FFFF
963 128 / 64 7860000-787FFFF 3C30 000-3C3FFFF
964 128 / 64 7880000-789FFFF 3C40 000-3C4FFFF
965 128 / 64 78A0000-78BFFFF 3C50000-3C5FFFF
966 128 / 64 78C0000 -78DFFFF 3C60000-3C6FFFF
967 128 / 64 78E0000-78FFFFF 3C70000-3C7FFFF
968 128 / 64 7900000-791FFFF 3C80 000-3C8FFFF
969 128 / 64 7920000-793FFFF 3C90 000-3C9FFFF
970 128 / 64 7940000-795FFFF 3CA0000-3CAFFFF
971 128 / 64 7960000-797FFFF 3CB0000-3CBFFFF
972 128 / 64 7980000-799FFFF 3CC0000-3CCFFFF
973 128 / 64 79A0000-79BFFFF 3CD0000 -3CDFFFF
974 128 / 64 79C0000-79DFFFF 3CE0000-3CEFFFF
975 128 / 64 79E0000-79FFFFF 3CF0000-3CFFFFF
976 128 / 64 7A00000-7A1FFFF 3D00000-3D0FFFF
977 128 / 64 7A20000-7A3FFFF 3D10000-3D1FFFF
978 128 / 64 7A40000-7A5FFFF 3D20000-3D2FFFF
979 128 / 64 7A60000-7A7FFFF 3D30000-3D3FFFF
980 128 / 64 7A80000-7A9FFFF 3D40000-3D4FFFF
981 128 / 64 7AA0000-7ABFFFF 3D50000-3D5FFFF
982 128 / 64 7AC0000-7ADFFFF 3D60000-3D6FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Memory Address Tabl e Numonyx™ Axcell™ M29EW
110 208045-11
983 128 / 64 7AE0000-7AFFFFF 3D70000-3D7FFFF
984 128 / 64 7B00000-7B1FFFF 3D80000-3D8FFFF
985 128 / 64 7B20000-7B3FFFF 3D90000-3D9FFFF
986 128 / 64 7B40000-7B5FFFF 3DA0000-3DAFFFF
987 128 / 64 7B60000-7B7FFFF 3DB0 000-3DBFFFF
988 128 / 64 7B80000-7B9FFFF 3DC0000 -3DCFFFF
989 128 / 64 7BA0000-7BBFFFF 3DD0000-3DDFFFF
990 128 / 64 7BC0000-7BDFFFF 3DE0000-3DEFFFF
991 128 / 64 7BE0000-7BFFFFF 3DF0000-3DFFFFF
992 128 / 64 7C00000 -7C1FFFF 3E00000-3 E0FFFF
993 128 / 64 7C20000 -7C3FFFF 3E10000-3 E1FFFF
994 128 / 64 7C40000 -7C5FFFF 3E20000-3 E2FFFF
995 128 / 64 7C60000 -7C7FFFF 3E30000-3 E3FFFF
996 128 / 64 7C80000 -7C9FFFF 3E40000-3 E4FFFF
997 128 / 64 7CA0000-7CBFFFF 3E50000-3E5FFFF
998 128 / 64 7CC0000-7CDFFFF 3E60 000-3E6FFFF
999 128 / 64 7CE0000-7CFFFFF 3E70000-3E7FFFF
1000 128 / 64 7D00000 -7D1FFFF 3E80000-3 E8FFFF
1001 128 / 64 7D20000 -7D3FFFF 3E90000-3 E9FFFF
1002 128 / 64 7D40000-7D5FFFF 3EA0000-3EAFFFF
1003 128 / 64 7D60000-7D7FFFF 3EB0000-3EBFFFF
1004 128 / 64 7D80000 -7D9FFFF 3EC0000-3ECFFFF
1005 128 / 64 7DA0000-7DBFFFF 3ED0000-3EDFFFF
1006 128 / 64 7DC0000-7DDFFFF 3EE0000-3EEFFFF
1007 128 / 64 7DE0000-7DFFFFF 3EF0000-3EFFFFF
1008 128 / 64 7E00000-7E1FFFF 3F00000-3F0FFFF
1009 128 / 64 7E20000-7E3FFFF 3F10000-3F1FFFF
1010 128 / 64 7E40000-7E5FFFF 3F20000-3F2FFFF
1011 128 / 64 7E60000-7E7FFFF 3F30000-3F3FFFF
1012 128 / 64 7E80000-7E9FFFF 3F40000-3F4FFFF
1013 128 / 64 7EA0000-7EBFFFF 3F50000-3F5FFFF
1014 128 / 64 7EC0000-7EDFFFF 3F60000-3F6FFFF
1015 128 / 64 7EE0000-7EFFFFF 3F70000 -3F7FFFF
1016 128 / 64 7F00000-7F1FFFF 3F80000-3F8FFFF
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Numonyx™ Axcell™ M29EW Memory Address Table
208045-11 111
1017 128 / 64 7F20000-7F3FFFF 3F90000-3F9FFFF
1018 128 / 64 7F40000-7F5FFFF 3FA0000-3FAFFFF
1019 128 / 64 7F60000-7F7FFFF 3FB0000-3FBFFFF
1020 128 / 64 7F80000-7F9FFFF 3FC0000-3FCFFFF
1021 128 / 64 7FA0000-7FBFFFF 3FD0000-3FDFFFF
1022 128 / 64 7FC0000-7FDFFFF 3FE0000-3FEFFFF
1023 128 / 64 7FE0000-7FFFFFF 3FF0000-3FFFFFF
1. The 256-Mbit device consists of 256 blocks, from block 0 to block 255.
2. The 512-Mbit device consists of 512 blocks, from block 0 to block 511.
3. The 1-Gbit device consists of 1024 blocks, from block 0 to block 1023.
4. The 2-Gbit device is a 1-Gbit/1-Gbit stack; there’re in total 2048 blocks, from block 0 to block 2047, including upper die and
bottom die.
Table 33. Block Address Table for Descrete Device (Up to 1-Gbit)(1)(2)(3)(4)
Block Number Block Size
(Kbytes / Kwords) x8 Address
(HEX) x16 Address
(HEX)
Common Flash Interface (CFI) Numonyx™ Axcell™ M2 9EW
112 208045-11
Appendix B Common Flash Interface (CFI)
The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from
the Flash memory device. It allo ws a system so ftware to query the de vice to d etermine v a rious electrical
and timing parameters, density information and functions supported by the memory. The system can
interface easily with the device, enabling the software to upgrade itself when necessary.
When the Read CFI Query command is issued, the memory enters Read CFI Query mode and read
operations output the CFI data. Table 34, Table 35, Table 36, Table 37 an d Table 38 and show the
addresses (A-1, A0-A7) used to retrieve the data.
Table 34. Query structure ov erview(1)
1. Query data are always presented on the lowest order data outputs.
Address Sub-section name Description
x16 x8
10h 20h CFI query identification string Command set ID and algorithm data offset
1Bh 36h System interface information Device timing & voltage information
27h 4Eh Device geometry definition Flash device layout
40h 80h Pr imary algorithm-specific extended query table Additional information specific to the primary
algorithm (optional)
Table 35. CFI query identification string(1)
1. Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’.
Address Data Description Value
x16 x8
10h 20h 0051h ‘Q’
11h 22h 0052h Query Unique ASCII String ‘QRY’ ‘R’
12h 24h 0059h ‘Y’
13h 26h 0002h Primary algorithm command set and control interface ID code 16 bit
ID code defining a specific algorithm AMD
compatible
14h 28h 0000h
15h 2Ah 0040h Address for primary algorithm extended query table (see Table 38) P = 40h
16h 2Ch 0000h
17h 2Eh 0000h Alternate vendor command set and control interface ID code second
vendor - specified algorithm supported NA
18h 30h 0000h
19h 32h 0000h Address for alternate algorithm extended query table NA
1Ah 34h 0000h
Numonyx™ Axcell™ M29EW Common Flash Interface (CFI)
208045-11 113
Table 36. CFI query system interface information(1)
Address Data Description Value
x16 x8
1Bh 36h 0027h VCC logic supply minimum Program/Erase voltage
bit 7 to 4BCD value in volts
bit 3 to 0BCD value in 100 mV 2.7 V
1Ch 38h 0036h VCC logic supply maximum Program/Erase voltage
bit 7 to 4BCD value in volts
bit 3 to 0BCD value in 100 mV 3.6 V
1Dh 3Ah 00B5h
VPPH [programming] supply minimum Program/Erase
voltage
bit 7 to 4HEX value in volts
bit 3 to 0BCD value in 100 mV
11.5 V
1Eh 3Ch 00C5h
VPPH [programming] supply maximum Prog ram/Erase
voltage
bit 7 to 4HEX value in volts
bit 3 to 0BCD value in 10 mV
12.5 V
1Fh 3Eh 0009h Typical time-out for single byte/word program = 2n µs 512 µs
20h 40h 000Ah Typical time-out f or maximum siz e buff er program = 2n
µs 1024 µs
21h 42h 000Ah Typical time-out for individual block erase = 2n ms 1 s
22h 44h 0012h / 0013h /
0014h / 0015h Typical time-out for full Chip Erase = 2n ms
256-Mbit 262 s
512-Mbit 524 s
1-Gbit 1048 s
2-Gbit 2097 s
23h 46h 0001h Maximum time-out for byte/word program = 2n times
typical time-out 1024 µs
24h 48h 0002h Maximum time-out for buffer program = 2n times
typical time-out 4096 µs
25h 4Ah 0002h Maximum time-out per individual block erase = 2n
times typical time-out 4s
26h 4Ch 0002h Maximum time-out for Chip Erase = 2n times typical
time-out
256-Mbit 1048 s
512-Mbit 2096 s
1-Gbit 4194 s
2-Gbit 8388 s
1. The values given in the above table are valid for both packages.
Common Flash Interface (CFI) Numonyx™ Axcell™ M2 9EW
114 208045-11
Table 37. Device geometry definition
Address Data Description Value
x16 x8
27h 4Eh 0019h / 001Ah / 001Bh/001 Ch Device size = 2n in number of bytes
32 Mbytes
64 Mbytes
128 Mbytes
256 Mbytes
28h
29h 50h
52h 0002h
0000h Flash device interface code description x8, x16
Async.
2Ah
2Bh 54h
56h 000Ah
0000h Maximum number of b ytes in multiple-byte
program or page= 2n1024(1)
2Ch 58h 0001h Number of Erase block regions. It specifies the
number of regions containing contiguous Erase
blocks of the same size. 1
2Dh
2Eh 5Ah
5Ch 00FFh / 00FFh / 00FFh / 00FFh
0000h / 0001h / 0003h / 0007h
Erase block region 1 information
Number of Erase blocks of identical size =
00FFh + 1 / 01FFh +1 / 03FFh + 1
256
512
1024
2048
2Fh
30h 5Eh
60h 0000h
0002h Erase block region 1 information
Block size in region 1 = 020 0h * 256 byte 128 Kbytes
31h
32h
33h
34h
62h
64h
66h
68h
0000h
0000h
0000h
0000h
Erase block region 2 information 0
35h
36h
37h
38h
6Ah
6Ch
6Eh
70h
0000h
0000h
0000h
0000h
Erase block region 3 information 0
39h
3Ah
3Bh
3Ch
72h
74h
76h
78h
0000h
0000h
0000h
0000h
Erase block region 4 information 0
1. For X16/X8 mode, the maximum buffer size is 1024 bytes/256 bytes respectively.
Numonyx™ Axcell™ M29EW Common Flash Interface (CFI)
208045-11 115
Table 38. Primary algorithm-specific extended query table (1)
Address Data Description Value
x16 x8
40h 80h 0050h
Primary algor ithm extended query table unique ASCII string “PRI”
‘P’
41h 82h 0052h ‘R’
42h 84h 0049h ‘I’
43h 86h 0031h Major version number, ASCII ‘1’
44h 88h 0033h Minor version number, ASCII ‘3’
45h 8Ah 0018h Address sensitive unlock (bits 1 to 0)
00 = required, 01= not required
Silicon revision number (bits 7 to 2) Required
46h 8Ch 0002h Erase Suspend
00 = not supported, 01 = Read only, 02 = read and write 2
47h 8Eh 0001h Block protection
00 = not supported, x = number of blocks per group 1
48h 90h 0000h Temporary block unprotect
00 = not supported, 01 = supported Not
supported
49h 92h 0008h Block protect / unprotect
08 = M29EWH/M29EWL 8
4Ah 94h 0000h Simultaneous operations: not supported NA
4Bh 96h 0000h Burst mode, 00 = not supported, 01 = supported Not
supported
4Ch 98h 0003h Page mode, 00 = not supported, 01 = 8-word page
02 = 8-word page, 03 = 16-word page 16-word
page
4Dh 9Ah 00B5h VPPH supply minimum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV 11.5 V
4Eh 9Ch 00C5h VPPH supply maximum Program/Erase v oltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV 12.5 V
4Fh 9Eh 00xxh Top/botto m boot block flag
xx = 04h: Uniform device, HW protection for lowest block
xx = 05h: Uniform device, HW protection for highest bloc k
Uniform +
VPP/WP#
protecting
highest or
lowest
block
50h A0h 0001h Program suspend, 00 = not support ed, 01 = supported Supported
1. The values given in the above table are valid for both packages.
Extended Memory Block Numonyx™ Axcell™ M29EW
116 208045-11
Appendix C Extended Memory Block
The M29EW has an e xtr a b lo c k, the Extende d Memory Block, that can be accessed u sing a
dedicated command. This Extended Memory Block is 128words in x16 mode and 256bytes
in x8 mode. It is used as a secur ity block (to provide a perm a ne n t secu rity identification
number) or to store additional information.
The de vice can be shipped either with the Extended Memory Block pre-loc k ed by Numon yx,
or unlocked.
If the Extended Memory Block is not pre-locked by Numonyx, it can be customer-lockable.
Its status is indicated by bit DQ7 of Extended Memory Block Verify Indicator. This bit is
permanently set to either ‘1’ or ‘0’ at the Numon yx f actory and cannot be chang ed. When set
to ‘1’, it indicates that the de vice is pre-lock ed b y Numonyx and the Extended Memory Block
is protected. When set to ‘0’, it indicates that the device is customer-lockable. Bit DQ7 being
permanently locked to either ‘1’ or ‘0’ is another security feature which ensures that a
customer-lockable device cannot be used instead of a Numonyx pre-locked on e.
Bit DQ7 is the most significant bit in the Extended Memory Block Verify Indicator. It can be
read in Auto Select mode using eith er the Programme r (see Table 7 and Table 8) or the In-
system method (see Table 9 and Table 10).
The Extended Memory Block can onl y be accessed when the de vice is in Extended Memory
Block mode. For details of how the Extended Memory Block mode is ent ered and exited,
refer to the Section 6.3.1: Enter Extended Memory Block command and Section 6.3.2: Exit
Extended Memory Block command, and to Table 13 and Table 9.
C.1 Numonyx pre-locked Extended Memory Block
If devices of which the Extended Memory Block is pre-locked upon customer request, the
128bits security identification number is written to the Extended Memory Block address
space (see Table 39: Extended Memory Bloc k address and data) in Numonyx factory. The
contents in the Exte nd e d Me m ory Block cannot be changed any more.
Numonyx™ Axcell™ M29EW Extended Memory Block
208045-11 117
C.2 Customer-lockable Extended Memory Block
A de vice where the Extended Memory Block is customer-loc kab le is deliv ered with the DQ7
bit set to ‘0’ and the Extended Memory Block unprotected. It is up to the customer to
program and protect the Extended Memory Block but care must be taken because the
protection of th e Exte nde d M em o ry Block is not reversible.
If the device has not been shipped with the Extended Memory Block pre-protected, the block
can be protected by setting the Extended Memory Block Protection bit, DQ0, to ‘0’.
How ever, this bit can only be programmed once; and once it is protected the Extended
Memory Block cannot be unprotected.
Once the Extended Memory Block is programmed, the Exit Extended Memory Block
command must be issue d to e xit the Extended Memory Block mode and return the de vice to
Read mode.
Table 39. Extended Memory Block address and data
Address(1) Data
x8 x16 Numonyx pre-locked Customer-lockable
000000h-00000Fh 000000h-000007h Secure identification
number Determined b y
customers
(default)
Secure identification
number
000010h-0000FFh 000008h-00007Fh Protected and
unavailable Determined by
customers
1.
Revision Hi story Numonyx™ Axce ll™ M29EW
118 208045-11
Appendix D Revision History
Table 40. Document revision history
Date Version Changes
May 2008 01 Initial release
Oct 2008 02 Update tAVAV values in Table 24 and Table 25
Move buffer program flow chart to Chapter 6.2.1, as Figure 8
Minor wording changes
Dec 2008 03
Apply AxcellTM as M29EW’s branding name
Change the names of timing parameters in Table 20, Table 26 and Table 27
Modify many waveforms to align the signal names
Some wording changes
Spec change of tEHEL2 from 20ns to 30ns, in Table 27
Remove “Numonyx Conf id e nt i al
Remove conventions section and set Revision History as Appendix D
Update physical dimension information in Table 29
Add Document Number
Add 1-Gbit and 512-Mbit information into the data sheet
Correct some typo error
Mar 2009 04
Correct the buffer write cycle numbers and wording correction in Table 11
and Table 12
Fix a text corr uption in Figure 8
Remove invalid ship op tions in Chapter 5.1
Add Figure 7 to explain the buffer pro gramming
Add buffer write misalignment description to better explain buffer
programming usage in Chapter 6.2.1
Move the disclaimer to the end of the data sheet
Add 10K ohm pull-up resistor description for RY/BY# pin
Update Fortified BGA physical dimension of ball size Table 30
Apr 2009 05
Remove notes about Enhanced Buffer Programming in Chapter 6.2.2
Change VPPH spec in Table 18 and Table 19
Change the address for VPB read in Table 13 and Table 14
Correct the DQ2 toggling states in Table 17
Jun 2009 06
Add technology information in cover page and Chapter 1
Add RoHS and Halogen Free information in cover page
Add block address information in Chapter Appendix A
Move programming and erase performance as separate chapter in
Chapter 10
Add leaded, RoHS, halogen free information in Chapter 12
Oct 2009 07 Add 2-Gbit (1-Gbit/1-Gbit) stack device related information
Numonyx™ Axcell™ M29EW Revision History
208045-11 119
Feb 2010 08
Revised part numbers in the Table 32.: Valid Combin ations of M29EW Part
Numbers
Update programming performance specifications and suspend latency
specifications in Table 28: Programming and Erase Performance
Update CFI information of program max timeout in Table 36: CFI query
system interface information
Add Erase to Suspend specification in Table 28: Programming and Erase
Performance
Add note for tDVWH in Table 24: Write AC characteristics , Write Enable
Controlled
Add note for tDVEH in Table 25: Write AC characteristics, Chip Enable
Controlled
Apr 2010 09
Update JEDEC compliance in cover page
Correct the buffer programming boundary limitation in Section 6.2.1: Write
to Buffer Program command
Update the specification of tPLRH(tREADY) in Table 26: Reset AC
characteristics
Update the description of VPP/WP# pin in Chapter 2.8: VPP/Write Protect
(VPP/WP#)
Add BYTE# transition waveform as Figure 19: BYTE# Transition AC
Waveform
May 2010 10 Update the Random Read AC waveforms about BYTE# pin in Section 9:
DC and AC Parameters
Put a link for product part numbers in Section 12: Ordering Information
Apr 2011 11
Add a bloc k diagr am Figure 2: 2-Gbit (1 -G bit/ 1-Gb it st ack) configu r at ion s to
emphasize 2G part is 1G/1 G sta ck, not discrete one
Remov e the in v alid automatic standby mode from front page and Section 3:
Bus Operations on page 17
Add tWHWH1 specification at Table 24: Write AC characteristics, Write
Enable Controlled and Table 25: Write AC characteristics, Chip Enable
Controlled
At CFI table offset 2Ah/2Bh (X16), add a note fo r X8 mode to emphasize its
maximum buffer size is 256 bytes
For read ID and read prote c tion status, align with device about higher
address pins input status at Table 5, Table 6, Table 7 and Table 8
Add JEDEC standard lead width for TSOP56 package at Table 29: TSOP56
– 56 lead thin small-outline package, 14 x 20 mm, package mechanical
data on page 78
Correct the glitch filter from 5ns to 3ns
Remov e the in valid statement about applying VID to A9 to enter Auto Select
mode at Section 7.1.3: Extended Memor y Block Protection bit (DQ0)
Add Blank Check related information
Align with device about DQ2 toggle status when Erase/Blank Check Error
happens at Table 17: Status Register bits
Date Version Changes
Numonyx™ Axcell™ M29EW
120
Please Read Carefully:
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX® PRODUCTS. NO LICENSE, EXPRESS OR
IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT
AS PROVIDED IN NUMONYX'S TER M S AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY
WHATSOEVER, AND NUMONYX DIS CLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF
NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR I NFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility
applications.
Numonyx may make changes to specificati ons and product descri ptions at any time, without notice.
Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the
presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied,
by estoppel or otherwise, to any s uch patents, trademarks, copyrights, or other intellectual property righ ts.
Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves
these for future definition and shall have no resp onsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product orde r.
Copies of doc uments which have an orde r number and are referenced in this document, or other Numonyx literat ure may be obtained by
visiting Numonyx's website at http://www.numonyx.com.
Numonyx™ Axcell is a trademark or regis tered trademark of Numo nyx or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2009, Numonyx, B.V., All Rights Reserved.
Home Products DRAM Modules RDIMM 1.35V RDIMM Part Catalog RC28F256M29EWHB
256Mb Parallel NOR Flash: RC28F256M29EWHB
Order Tech Notes Documentation
Certifications
No Certificates
© 2012 Micron Technology, Inc. All Rights Reserved
For more than 30 years, Micron’s teams of dreamers, visionaries, and scientists have redefined innovation—designing and building some of the world’s most advanced memory and
semiconductor technologies. We develop the technologies that transform what's possible. In fact, you likely use our memory every day—in products from computing, networking, and server
applications, to mobile, embedded, consumer, automotive, and industrial designs. As one of the most prolific patent holders in the world we continually rethink, recast, and advance new ideas to
bring innovation to broader markets and find ways our technology can inspire new applications or make fundamental improvements to existing designs. Our roots are in memory, the core
strength of our business. As we look toward the future, we’ll continue to build on our past achievements by leveraging the synergies between our core memory business and diversified products
and technologies that help drive innovation and growth in new markets.
Site Map Contact Us Crucial.com Lexar.com RSS Feeds Privacy Policy Terms of Use CA SB 657
Specifications
Technology: Parallel NOR Flash
Module Density:
Part Status Code: Production
RoHS: No
Number of Components:
Depth:
Bus Width: x8/x16
Pin Count: 64-ball
Operating Temp: -40C to +85C
MT/s:
Industry Speed:
CAS Latency:
Voltage: 2.7V-3.6V
Component Config:
ECC:
Module Rank:
Register:
Data Sheets
256Mb, 512Mb, 1Gb, 2Gb,
3V Parallel NOR Flash:
M29EW
Rev. Date: 04/2011, File Size:
1.98 MB
256Mb Parallel NOR Flash:
M29EW Errata
Rev. Date: 02/2011, File Size:
140.45 KB
RC28F256M29EWHB Production Contact Rep
Orderable Part Part Status Buy Online
Please Note: Distributor inventory is an estimate and may not reflect actual
available memory. Some links on this page will take you from the Micron web site.
Micron does not control the content on these web sites.
简体中文 日本語 Investors Press Relations Jobs
Login Sign up for Access View Cart
Page 1 of 1RC28F256M29EWHB - Micron Technology, Inc.
19-Jan-2012htt
p
://www.micron.com/
p
arts/no
r
-flash/
p
arallel-no
r
-flash/rc28f256m29ewhb?
p
c=%7BF...