https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Electronic device circuit breaker, number of positions:1, connection method:Screw connection, width:12.5 mm, fuse type:electronic, fuse type:Automatic device, mounting type:on base element, Color:black Your advantages Can be plugged onto TMCP SOCKET M base Design width of just 12.5 mm The operating or error state is indicated by a multi-color LED as well as an integrated status output (12) Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356103992 Weight per Piece (excluding packing) 41.500 g Custom tariff number 85362010 Country of origin Germany Technical data General Installation instructions When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor). Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC). Parallel connection of multiple circuit breakers is not permitted. Mounting type on base element Color black 01/17/2021Page1/6 https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Technical data General Number of positions 1 Overvoltage category II Insulating material PA66/6 Flammability rating according to UL 94 V0 Electrical data Fuse electronic Fuse type Automatic device Rated surge voltage 0.5 kV Operating voltage 24 VDC 24 VDC (at 50 C (UL 2367, UL 508, ANSI/ISA 12.12.01)) 18 VDC ... 32 VDC Nominal current IN 2A Required backup fuse not required, integrated failsafe element Dielectric strength max. 32 VDC (Load circuit) Degree of pollution 2 Overvoltage category II Insulating material group I Switching capacity ICN Active current limitation Closed-circuit current range I0 typ. 25 mA 5mA (When switched on) Dimensions Height 60 mm Width 12.5 mm Depth 70 mm Height NS 35/7,5 144 mm Height NS 35/15 151.5 mm Complete module height 115 mm Complete module width 38 mm Complete module depth 112.5 mm Ambient conditions Degree of protection IP30 (Actuation area) Ambient temperature (operation) 0 C ... 50 C (non-condensing) Connection data Connection method Screw connection Standards and Regulations Standards/specifications UL 2367 01/17/2021Page2/6 https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Technical data Standards and Regulations UL 508 CSA22.2 No. 14 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram Diagram Stop point typ. 1,1 x l N On/Off 14 12 2 Switching time [s] GND (-) Reset Reset Control Unit 1 11 13 LINE (+) Status 10 10 1,8 x l N 4 3 10 2 10 5 1 LOAD (L+) 0,1 0,01 0 1 2 IK 3 Multiples of IN Classifications eCl@ss eCl@ss 10.0.1 27140401 eCl@ss 11.0 27140401 eCl@ss 4.0 27141100 eCl@ss 4.1 27141100 eCl@ss 5.0 27141100 eCl@ss 5.1 27141100 eCl@ss 6.0 27141100 eCl@ss 7.0 27141116 eCl@ss 8.0 27141116 eCl@ss 9.0 27141116 ETIM ETIM 2.0 EC000899 01/17/2021Page3/6 https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Classifications ETIM ETIM 3.0 EC000899 ETIM 4.0 EC000899 ETIM 5.0 EC000899 ETIM 6.0 EC000899 ETIM 7.0 EC000899 UNSPSC UNSPSC 6.01 30211812 UNSPSC 7.0901 39121411 UNSPSC 11 39121411 UNSPSC 12.01 39121411 UNSPSC 13.2 39121410 UNSPSC 18.0 39121410 UNSPSC 19.0 39121410 UNSPSC 20.0 39121410 UNSPSC 21.0 39121410 Approvals Approvals Approvals UL Recognized Ex Approvals UL Recognized / CSA Approval details UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 317172 Accessories Accessories Marker pen 01/17/2021Page4/6 https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Accessories Marker pen-X-PEN 0,35-0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Terminal marking Zack marker strip-ZB 6:UNBEDRUCKT-1051003 Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block width: 6.2 mm, lettering field size: 6.15 x 10.5 mm, Number of individual labels: 10 Zack marker strip-ZB 6/WH-100:UNBEDRUCKT-5060935 Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block width: 6.2 mm, lettering field size: 6.15 x 10.5 mm, Number of individual labels: 10 Additional products Box mounting base-TMCP SOCKET M-0916589 Modular socket element, 2-position, for holding two circuit breakers, each with a single position End cover-TMCP CONNECT LR-0916592 End cover, width:6 mm, Color:black 01/17/2021Page5/6 https://www.phoenixcontact.com/us/products/0900210 Electronic device circuit breaker-ECP-E 2A-0900210 Accessories Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/17/2021Page6/6