HTF3000LF - Temperature and Relative Humidity Module * Small size product * Compliant with RoHS recommendations and most of Lead Free Soldering Process * Humidity calibrated within +/-3% @55%RH at 5Vdc * Stable, proportional frequency output from 0 to 100% RH * High quality thermistor DESCRIPTION Based on the rugged HS1101LF humidity sensor, HTF3000LF is a dedicated humidity and temperature transducer designed for OEM applications where a reliable and accurate measurement is needed. It features a very small size for easy, cost-effective mechanical mounting. Direct interface with a micro-controller is made possible with the module's linear frequency output. FEATURES * One of the smallest humidity/temperature modules on the market Humidity Sensor Specific Features * High reliability and long term stability * Not affected by water immersion * * * * Stable characteristics with temperature Temperature Sensor Specific Features * Part could be washed with distilled water * * * * Instantaneous de-saturation after long periods in saturation phase Fast response time High resistance to chemicals Patented solid polymer structure 10k +/-1% NTC temperature sensor Stable High sensitivity APPLICATIONS * Printers * HVAC controller ... HTF3000LF HPC077 Rev J www.meas-spec.com 1/7 October 2012 HTF3000LF - Temperature and Relative Humidity Module PERFORMANCE SPECS MAXIMUM RATINGS Ratings Storage Temperature Storage Humidity Supply Voltage (Peak) Humidity Operating Range Temperature Operating Range Symbol Tstg RHstg Vs RH Ta Value -40 to 105 0 to 100 16 0 to 100 -40 to 85 Unit C % RH Vdc % RH C Peak conditions: less than 10% of the operating time. Operating Range Temperature in C ELECTRICAL CHARACTERISTICS (Ta=23C, Vs=5Vdc +/-5%, RL>1M unless otherwise stated) Humidity Characteristics Humidity Measuring Range Relative Humidity Accuracy (0 to 100% RH) Supply Voltage Nominal Output @55%RH (at 5Vdc) Current consumption (Max at 16Vdc) Supply Voltage Influence (3 to 7Vdc) Average Sensitivity from 10% to 95%RH Humidity Hysteresis Long Term Stability Time Constant (at 63% of signal, static) 40% to 95%RH, 2m/s Symbol RH RH Vs Fout Ic RH Fout/RH T Min Typ Max 0 100 Refer to Chart 2 on page 3 3 5 8 6560 6600 6640 0.18 1 +/-1 -10 -12 -14 +/-1 +/-0.5 10 Unit %RH %RH Vdc Hz mA % RH Hz/%RH %RH %RH/yr s (Ta=25C) Temperature Characteristics Nominal Resistance @25C Beta value: B25/100 Temperature Measuring Range Nominal Resistance Tolerance @25C Beta Value Tolerance Response Time HTF3000LF HPC077 Rev J Symbol R Ta RN www.meas-spec.com 2/7 Min 3346 -40 Typ 10 3380 1 1 10 Max 3413 85 Unit k C % % s October 2012 HTF3000LF - Temperature and Relative Humidity Module TYPICAL PERFORMANCE CURVES HUMIDITY SENSOR * Relative Humidity Accuracy of HTF3000LF @23C * Modeled Signal Output Equations Fout = 7314 - 16.79*RH + 0.0886*RH - 0.000358*RH Fout in Hz and RH in % * 3 Modeled Reversed Output Equations -10 3 -5 RH = 89.8*10 *Fout - 15.7486*10 *Fout + 0.80945*Fout - 1009 Fout in Hz and RH in % * Typical response look-up table RH (%) 1 5 10 15 20 25 30 35 40 45 50 Fout (Hz) 7295 7230 7155 7080 7010 6945 6880 6820 6760 6705 6650 RH (%) 55 60 65 70 75 80 85 90 95 99 Fout (Hz) 6600 6550 6500 6450 6400 6355 6305 6260 6210 6170 Output Voltage wave form HTF3000LF HPC077 Rev J www.meas-spec.com 3/7 October 2012 HTF3000LF - Temperature and Relative Humidity Module * Temperature influence on HTF3000LF humidity measurement Calibration data are traceable to NIST standards through CETIAT laboratory. For demanding application, temperature coefficient could be compensated over operating temperature range using following formula: RHcorr = RH + 0.08 * ( T - 25 ) Fout Corr = Fout - 0.88 * ( T - 25 ) T in C, RH in %, Fout in Hz TEMPERATURE SENSOR * Typical temperature output Depending on the needed temperature measurement range and associated accuracy, we suggest two methods to access to the NTC resistance values. RT = RN e RT RN T, TN e 1 1 ) T TN ( - NTC resistance in at temperature T in K NTC resistance in at rated temperature T in K Temperature in K Beta value, material specific constant of NTC Base of natural logarithm (e=2.71828) The exponential relation only roughly describes the actual characteristic of an NTC thermistor can, however, as the material parameter in reality also depend on temperature. So this approach is suitable for describing a restricted range around the rated temperature or resistance with sufficient accuracy. For practical applications, a more precise description of the real R/T curve may be required. Either more complicated approaches (e.g. the Steinhart-Hart equation) are used or the resistance/temperature relation as given in tabulation form. The below table has been experimentally determined with utmost accuracy for temperature increments of 1 degree. Actual values may also be influenced by inherent self-heating properties of NTCs. Please refer to MEAS-France Application Note HPC106-0 "Low power NTC measurement". HTF3000LF HPC077 Rev J www.meas-spec.com 4/7 October 2012 HTF3000LF - Temperature and Relative Humidity Module * Temperature Look-up Table Temp Rout Max Dev Temp Rout Max Dev Temp Rout Max Dev (C) () () (C) () () (C) () () -40 -39 -38 -37 -36 -35 -34 -33 -32 -31 -30 -29 -28 -27 -26 -25 -24 -23 -22 -21 -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 195652 184917 174845 165391 156513 148171 140330 132958 126022 119494 113347 107565 102116 96978 92132 87559 83242 79166 75316 71677 68237 64991 61919 59011 56258 53650 51178 48835 46613 44506 42506 40600 38791 37073 35442 33892 32420 31020 29689 28423 27219 26076 7921 7378 6874 6407 5974 5571 5197 4849 4527 4226 3947 3687 3446 3221 3011 2815 2633 2463 2305 2157 2019 1890 1770 1658 1553 1454 1363 1277 1197 1121 1051 985 923 865 810 759 712 667 625 586 549 514 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 24988 23951 22963 22021 21123 20267 19450 18670 17926 17214 16534 15886 15266 14674 14108 13566 13049 12554 12081 11628 11195 10780 10382 10000 9634 9284 8947 8624 8315 8018 7734 7461 7199 6948 6707 6475 6253 6039 5834 5636 5445 5262 482 452 423 396 371 348 326 305 285 267 250 233 218 204 190 178 166 154 144 134 125 116 108 100 100 100 100 99 99 98 98 97 96 95 94 93 92 91 90 89 88 87 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 5086 4917 4754 4597 4446 4301 4161 4026 3896 3771 3651 3535 3423 3315 3211 3111 3014 2922 2834 2748 2666 2586 2509 2435 2364 2294 2228 2163 2100 2040 1981 1925 1870 1817 1766 1716 1669 1622 1578 1535 1493 1452 86 85 83 82 81 80 79 77 76 75 74 73 72 70 69 68 67 66 65 64 63 62 60 59 58 57 56 55 54 53 52 52 51 50 49 48 47 46 46 45 44 43 HTF3000LF HPC077 Rev J www.meas-spec.com 5/7 October 2012 HTF3000LF - Temperature and Relative Humidity Module QUALIFICATION PROCESS RESISTANCE TO PHYSICAL AND CHEMICAL STRESSES * * * HTF3000LF has passed through qualification processes of MEAS-France including vibration, shock, storage, high temperature and humidity. Additional tests under harsh chemical conditions demonstrate good operation in presence of salt atmosphere, SO2 (0.5%), H2S (0.5%), 03, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3, HCI), HMDS, Insecticide, Cigarette smoke, this is not an exhaustive list. ESD: HTF3000LF is able to sustain a minimum of +/-8kV (contact discharge). PACKAGE OUTLINE HTF3000LF PVH Dim A B C D E F K Min 17.9 12.0 10.7 14.25 4.80 1.76 0.54 Max 18.9 13.0 11.7 14.95 5.40 3.76 0.74 Dimensions in millimeters RECOMMENDED THROUGH HOLE FOOTPRINT HTF3000LF HPC077 Rev J www.meas-spec.com 6/7 October 2012 HTF3000LF - Temperature and Relative Humidity Module SOLDERING INFORMATION HTF3000LF PVH: Hand soldering or wave soldering ORDERING INFORMATION HPP808H031 FOR HTF3000LF PVH STORAGE: TUBE M.Q.P OF 48 PARTS; BOX M.Q.P OF 1008 PARTS (21 TUBES) Sample kit of HTF3000LF is available through MEASUREMENT SPECIALTIES web site: http://www.meas-spec.com/humidity-sensors.aspx Customer Service contact details Measurement Specialties, Inc - MEAS France Impasse Jeanne Benozzi CS 83 163 31027 Toulouse Cedex 3 FRANCE Tel: +33 (0)5 820 822 02 Fax: +33(0)5 820 821 51 Sales: humidity.sales@meas-spec.com Revision F G H I J Comments HTF3000LF RL reference added, product storage quantities added Mechanical dimension tolerance updated Soldering information paragraph updated, chart2 improved (poor image), HTF3000LF SMD and HTF3000LF RL references removed Standardized datasheet format New MEAS template, MEAS-France contact details updated Who Date D. LE GALL November 07 D. BEZ December 07 D. LE GALL January 08 D. LE GALL April 08 D. LE GALL-ZIRILLI October 12 The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer's technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. HTF3000LF HPC077 Rev J www.meas-spec.com 7/7 October 2012 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: HTF3000LF HTF3000LFPVH HPP808H031