Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
1
Features
Integrated Directional Coupler
Low Insertion Loss: 0.5 dB @ 20 GHz
Min. detectable power: -15 dBm @ 20 GHz
Dynamic range: 45 dB @ 20 GHz
Built-In Temperature Compensation
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
The MACP-010563 belongs to a series of small,
easy-to-use, broadband, directional detectors. With
integrated low loss directional couplers and built-in
temperature compensation circuits, these detectors
provide an easy way to monitor the power of a signal
travelling in a specific direction along a transmission
line. Detectors are housed in a miniature, surface
mount, lead less plastic package. They require a
small amount of bias for proper performance. The
total bias current is less than 0.5 mA.
Typical applications include power monitoring and
leveling in Point-to-Point radios, IMS, Radar, VSAT,
EW, and Aerospace & Defense systems.
The surface mount package is small yet can be
handled and placed with standard pick and place
assembly equipment. Detectors are fabricated on a
well established GaAs process featuring full
passivation for performance and reliability.
Ordering Information 1,2
Part Number Package
MACP-010563-TR1000 1000 piece reel
MACP-010563-001SMB Sample Board
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
Functional Schematic
Pin Configuration 3
Pin No. Pin Name Description
1 RFIN RF Input
2 N/C No Connection
3 V bias Bias Voltage
4 V det Output Voltage
5 N/C No Connection
6 RFOUT RF Output
7 GND Ground
3. Pins 2 and 5 are not connected internally and should not be
used for grounding. Package has exposed bottom metal
paddle (Pin 7) which should be connected to the circuit
ground. The parasitic inductance introduced by this connec-
tion should be as small as possible.
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
2
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
2
Electrical Specifications:
Freq. = 20 GHz, TA = +25°C, VB = 3.2 V, Z0 = 50 Ω (unless otherwise specified)
Parameter Units Min. Typ. Max. Test Conditions
Insertion Loss dB
0.16
0.48
0.97
10 GHz
20 GHz
30 GHz
Detect Voltage mV
221
470
806
10 dBm applied to Input
10 GHz
20 GHz
30 GHz
Directivity dB
19.5
16.0
10.8
Into 50 Ω load
10 GHz
20 GHz
30 GHz
Sensitivity dBm
-11
-17
-22
Minimum recommended power level
10 GHz
20 GHz
30 GHz
Maximum Power dBm 30
Maximum recommended power level
10 - 30 GHz
Input Return Loss dB 16 10 - 30 GHz
Output Return Loss dB 17.5 10 - 30 GHz
DC Offset mV 50 100 150 Detect voltage with no RF input power
Bias Current mA 0.3 0.35 V Bias = 3.2 V
Absolute Maximum Ratings 4,5
Parameter Absolute Maximum
Input Power +40 dBm
Operating Voltage 8 V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
4. Exceeding any one or combination of these limits may cause
permanent damage to this device.
5. M/A-COM Technology Solutions does not recommend
sustained operation near these survivability limits.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
3
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
3
Recommended PCB Configuration Application Information
The MACP-010563 is designed to deliver high
performance and to be easy to use.
No external components are needed. The RF
connections required by the MACP-010563 are
shown in a schematic below.
Pin 1 should be connected to the RF line bringing
the input signal. Pin 6 is the RF output. The third
required connection is that to the RF ground. The
exposed metal paddle on the back of the package
must be connected to the RF ground of the board
housing the detector. This can be accomplished by
using conductive via holes. It is important to ensure
that the parasitic inductance associated with the
connection between the detector and the RF ground
is as small as possible. The RF ground also provides
the return path for the DC bias current.
DC Bias
The MACP-010563 operates with a positive 3.2 V
bias applied to Pin 3. The output voltage is available
on Pin 4.
Evaluation Board
MA-COM Technology Solutions’ will supply an
evaluation board and loose samples upon qualified
request. The kit consists of a PCB and SMA
connectors. MA-COM Technology Solutions
suggests a Rogers 4350 dielectric of .008” (0.20
mm) with ½ ounce copper. Proper grounding is
always important, we suggest 8 mil (0.20 mm) vias
placed generously underneath the part.
RF Input
(Pin 1)
RF Output
(Pin 6)
RF Ground
MACP-010563
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
4
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
4
Typical Performance Curves:
Directivity
Detect Voltage Output vs. Input Power
Input Return Loss Output Return Loss
Insertion Loss
-1.0
-0.8
-0.6
-0.4
-0.2
0.0
0 5 10 15 20 25 30
+25°C
-40°C
+85°C
Frequency (GHz)
-60
-50
-40
-30
-20
-10
0
0 5 10 15 20 25 30
+25°C
-40°C
+85°C
Frequency (GHz)
0
5
10
15
20
25
10 15 20 25 30
+25°C
-40°C
+85°C
Frequency (GHz)
-60
-50
-40
-30
-20
-10
0
0 5 10 15 20 25 30
+25°C
-40°C
+85°C
Frequency (GHz)
0
2
4
6
8
-10 0 10 20 30
10 GHz
15 GHz
30 GHz
Input Power (dBm)
-0.1
0.0
0.1
0.2
0.3
-10 0 10 20 30
10 GHz
15 GHz
30 GHz
Input Power (dBm)
Temperature Compensation Error vs. Input Power
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
5
5
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
5
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is 100% matte tin over copper.
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN
All dimensions are in inches/mm.
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V2
MACP-010563
6
6
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
6
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.