Rev. 06.18.10_139
NFS110-M Series
3 of 5
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Convection cooled, 80 W maximum.
2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
5 Totalregulationisdenedatthestaticoutputregulationat25°C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings. Also for NFS110-7902PJ, for 24 V output stated
regulation IA / IB ² 5. This output will maintain ±5.0% regulation if
IA ² 5 A, where IA = +5.1 V output current and IB = +24 V output current.
6 Singleoutputmodelshaveoatingoutputswhichmaybereferencedaseither
positive or negative. Higher voltage supplies, may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
7 Power fail detect not available on single output models.
8 Deratingcurveisapplicationspecicforambienttemperatures>50°C,
for optimum reliability no part of the heatsink should exceed 90 °C and no
semiconductor case temperature should exceed 100 °C.
9 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
10 The user should read the PSU installation instructions in conjunction with the
relevant national safety regulations in order to ensure compliance.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 The‘J’sufxindicatesthatthesepartsarePb-free(RoHS6/6)compliant.TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
14 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
searchtoolathttp://www.Emerson.com/EmbeddedPowertondasuitable
alternative.
Ordering Information
Output
Voltage
Output Currents
Ripple (4) Total
Regulation (5) Model Numbers (13, 14, F)
Max (1) Peak (2) Fan (3)
+5.1 V 8 A 20 A 10 A 50 mV ± 2.0% NFS110-7901PJ
+12 V 4.5 A 9 A 5 A 120 mV ± 3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0%
–5 V 0.5 A 1.5 A 1 A 50 mV ± 3.0%
+5.1 V (IA)8 A 20 A 10 A 50 mV ± 2.0% NFS110-7902PJ
+24 V (IB) (6) 3.5 A 4.5 A 4.5 A 240 mV +10/–5.0%
+12 V 4.5 A 9 A 5 A 120 mV ± 3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0%
12 V 7 A 9 A 9 A 120 mV ± 2.0% NFS110-7912J (7,8)
15 V 5 A 7.3 A 7.3 A 150 mV ± 2.0% NFS110-7915J (7,8)
24 V 3.5 A 4.5 A 4.5 A 240 mV ± 2.0% NFS110-7924J (7,8)
Transient Response
NFS110-7901PJ +5.1 V (7.5-10 A) 150 mV peak,
1 ms recovery
+12 V (2.5-5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
-5 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
NFS110-7902PJ +5.1 V (7.5-10 A) 150 mV peak,
1 ms recovery
+12 V (2.5-5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
24 V (1.5-3 A) 300 mV peak,1
ms recovery
NFS110-7905J +5.1 V (10-20 A) 250 mV peak,
1 ms recovery
NFS110-7912J +12 V (4.5-9 A) 360 mV peak,
1 ms recovery
NFS110-7915J +15 V (3.65-7.3 A) 450 mV peak,
1 ms recovery
NFS110-7924J +24 V (2.25-4.5 A 720 mV peak,
1 ms recovery