RS1001M THRU RS1007M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes FEATURES Low leakage Low forward voltage Mounting position : Any Surge overload rating: 200 Amperes peak Ideal for printed circuit boards MSL: Level 2 .057 (1.45) .041 (1.05) .083 (2.1) .069 (1.7) .122 (3 .1 ) .114 (2.9) .074 (1.9) .059 (1.5) .043 (1.1) .035 (0.9) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS f.134 ( 3.4 ) .157 ( 4 ) * UL listed the recognized component directory, file #E94233 * Epoxy: Device has UL flammability classification 94V-O .189 (4.8) .173 (4.4) .150 (3.8) .134 (3.4) .366 (9 .3 ) MECHANICAL DATA .602 (15.3 ) .578 (14.7) .995 (25.3) .983 (24.7) .382 (9 .7 ) RS-10M .098 (2.5) .146 ( 3.7 ) .130 ( 3.3 ) .708 ( 18.0 ) .669 ( 17.0 ) * * * * * * .031 (0.8) .023 (0.6) Ratings at 25 OC ambient temperature unless otherwise specified. resistive or inductive load. .303 (7.7) .287 (7.3) .303 (7.7) .287 (7.3) .303 (7.7) .287 (7.3) Dimensions in inches and (millimeters) MAXIMUM CHARACTERISTICS ( @ TA = 25oC unless otherwise noted ) CHARACTERISTICS SYMBOL RS1001M RS1002M RS1003M RS1004M RS1005M RS1006M RS1007M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Bridge Input Voltage VRMS 35 70 140 280 420 560 700 Volts Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Volts Maximum Average Forward Rectified Output Current at Tc=100 degree with heatsink IO 10 Amps Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load IFSM 200 Amps Typical Current Square Time I 2T 165.9 A 2S Typical Thermal Resistance from junction to ambient RJA 22 RJC 1.0 TJ,TSTG -55 to + 150 Typical Thermal Resistance from junction to case Operating and Storage Temperature Range C/W O C O o ELECTRICAL CHARACTERISTICS ( @ TA = 25 C unless otherwise noted ) CHARACTERISTICS SYMBOL Maximum Forward Voltage Drop per element at 5.0A DC Maximum Reverse Current at Rated DC Blocking Voltage per element TA=25 OC TC=100 OC Note: 1."Fully ROHS compliant", "100% Sn plating (Pb-free)". 2. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. VF IR RS1001M RS1002M RS1003M RS1004M RS1005M RS1006M RS1007M UNITS 1.1 Volts 5.0 Amps 0.2 mAmps 2010-11 REV: A 30 20 60 10 50 POWER DISSIPATIONFP(W) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RS1001M THRU RS1007M ) 5 TC = 150 C o 2 (TYP) T C = 25 C (TYP) o 1 0.5 0.2 0.1 0.2 pulse test per one diode 0.4 0.6 0.8 1 1.2 1.4 sine wave o Tj=150 C 40 30 20 10 0 1.6 0 FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS sine wave 0 8.3ms 8.3ms 1 cycle non-repetitive o Tj=25 C 200 100 0 1 2 5 10 20 50 3 P.C.B soldering land 5mmf sine wave R-load free in air 2 1 0 100 0 40 THERMAL RESISTANCE (oC/W) AVERAGE FORWARD CURRENT, (A) 6 sine wave R-load on heatsink 4 2 120 130 80 120 160 FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE 1.6 Tc 8 110 24 AMBIENT TEMPERATURE( C) heatsink Tc 100 20 O 10 90 16 on glass-epoxi substrate FIG.3 SURGE FORWARD CURRENT CAPABILITY 80 12 4 NUMBER OF CYCLE 0 8 FIG.2 POWER DISSPATION AVERAGE FORWARD CURRENT, (A) 300 4 AVERAGE RECTIFIED FORWARD CURRENT, Io (A) IFSM PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS FORWARD VOLTAGE, (V) 140 150 CASE TEMPERATURE C o FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 160 with thermal compound 1.5 1.4 1.3 1.2 1.1 1 2 3 4 5 6 7 8 MOUNTING RORQUE (Kg.cm) FIG.6 CONTACT THERMAL RESISTANCE Marking Description Rectron Logo RS100XM Plant - code UL Logo Year - code (Y: Last digit of year & A:2010, B:2011.....) Part No. Voltage-code V Y WW Week - code (WW: 01~52) 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE PACKING CODE RS-4M/-10M -B 600 236*236*40 497*251*100 2,400 11.09 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON WEIGHT(Kg) RS-4M/-10M -C 900 540*118*118 560*259*144 1,800 12.82 (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE TUBE PACK (mm) (mm) DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.