2 Way 0º Power Divider
5-1000MHz
Rev. V3
MAPDCT0029
1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
1
Features
Surface Mount
2 Way 0 degree
260°C Reflow Compatible
RoHS* Compliant
Available on Tape and Reel.
Description
M/A-COM’s MAPDCT0029 is 2 way 0 degree RF
power divider in a low cost, surface mount package.
A 160 Ohm resistor included on the component.
Ideally suited for high volume CATV/Broadband
applications.
Pin Configuration
Ordering Information
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
Functional Block Diagram
Reference Application Note M513 for reel size information.
Pin No. Function
1 Ground
2 Not connected (ground)
3 Output 2
4 Output 1
5 Not connected (ground)
6 Input
Part Number Package
MAPDCT0029TR 900 piece reel
Parameter Absolute Maximum
Max Input Power 1W
DC current 240mA
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +100°C
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
Absolute Maximum Ratings 1,2
2 Way 0º Power Divider
5-1000MHz
Rev. V3
MAPDCT0029
2
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
2
Parameter
Test
Conditions
Frequency Units Min Typ Max
Insertion Loss - 5 - 500 MHz dB - 0.5 0.7
Insertion Loss - 500 - 1000 MHz dB - 0.7 1.4
Amplitude Unbalance
(Nominal 0dB)
- 5 - 1000 MHz dB - ± 0.28 ± 0.55
Phase Unbalance (Nominal 0º) - 5 - 1000 MHz º - ± 1.0 ± 3.0
Return Loss: Input - 5 - 50 MHz dB 24 35 -
Return Loss: Input - 50 - 870 MHz dB 14 26 -
Return Loss: Input - 870 - 1000 MHz dB 11 16 -
Return Loss: Output - 5 - 1000 MHz dB 15 22.5 -
Isolation (between outputs) - 5 - 50 MHz dB 20 26 -
Isolation (between outputs) - 50 - 870 MHz dB 14 22 -
Isolation (between outputs) - 870 - 1000 MHz dB 12 15 -
Case Style: SM-55
Electrical Specifications: TA = 25°C, Z0 = 75 1
2 Way 0º Power Divider
5-1000MHz
Rev. V3
MAPDCT0029
3
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
3
Isolation
Amplitude Unbalance Phase Unbalance
Typical Performance Curves: TA = 25°C, Z0 = 75 1
Return Loss: Input Return Loss: Output
Insertion Loss
- 40
- 35
- 30
- 25
- 20
- 15
- 10
-5
0
5204 403 602 801 1000
F re que nc y ( M H z)
dB
- 40
- 35
- 30
- 25
- 20
- 15
- 10
-5
0
5204 403 602 801 1000
F re quency (M H z)
dB
- 1.0
- 0.9
- 0.8
- 0.7
- 0.6
- 0.5
- 0.4
- 0.3
- 0.2
- 0.1
0.0
5204 403 602 801 1000
F re que nc y ( M H z)
-1.0
-0.8
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
5204 403 602 801 100 0
Frequency (M Hz)
dB
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
5204 403 602 801 100 0
Frequency (M Hz)
degree
- 40
- 35
- 30
- 25
- 20
- 15
- 10
-5
0
5204 403 602 801 1000
F re quency (M H z)
dB
2 Way 0º Power Divider
5-1000MHz
Rev. V3
MAPDCT0029
4
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
4
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.